CoChat

Radiographic Evaluation of Bone Remodeling after Additively Manufactured Subperiosteal Jaw Implantation (AMSJI) in the Maxilla: A One-Year Follow-Up Study

Open access
Van den Borre, Casper, Rinaldi, Marco, De Neef, Björn, Loomans, Natalie A. J., Nout, Erik, Van Doorne, Luc, Naert, Ignace, Politis, Constantinus, Schouten, Hylke, Klomp, Geert, Beckers, Ludovic, Freilich, Marshall M., Mommaerts, Maurice Y. · 2021 · Journal of Clinical Medicine
Cited by 36

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Additively manufactured subperiosteal jaw implants (AMSJI) are patient-specific, 3D-printed, titanium implants that provide an alternative solution for patients with severe maxillary bone atrophy. The aim of this study was to evaluate the bony remodeling of the maxillary crest and supporting bone using AMSJI. Fifteen patients with a Cawood–Howell Class V or greater degree of maxillary atrophy were evaluated using (cone beam) computed tomography scans at set intervals: one month (T1) and twelve months (T2) after definitive masticatory loading of bilateral AMSJI implants in the maxilla. The postoperative images were segmented and superimposed on the preoperative images. Fixed evaluation points were determined in advance, and surface comparison was carried out to calculate and visualize the effects of AMSJITM on the surrounding bone. A total mean negative bone remodeling of 0.26 mm (SD 0.65 mm) was seen over six reference points on the crest. Minor bone loss (mean 0.088 mm resorption, SD 0.29 mm) was seen at the supporting bone at the wings and basal frame. We conclude that reconstruction of the severely atrophic maxilla with the AMSJI results in minimal effect on supporting bone. Reduced stress shielding with a biomechanically tuned subperiosteal implant does not induce radiographically significant crestal bone atrophy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/jcm10163542

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 36

Metadata

Authors
Van den Borre, C., Rinaldi, M., De Neef, B., Loomans, N. A. J., Nout, E., Van Doorne, L., Naert, I., Politis, C., Schouten, H., Klomp, G., Beckers, L., Freilich, M. M., & Mommaerts, M. Y.
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2021-08-12
Volume
10
Issue
16
Pages
3542
ISSN
2077-0383 (ISSN-L)
OpenAlex
W3192850238
Cited by
36
References
4
FWCI
4.63
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiographic Evaluation of Bone Remodeling after Additively Manufactured Subperiosteal Jaw Implantation (AMSJI) in the Maxilla: A One-Year Follow-Up Study. https://app.cochat.ai/papers/10.3390/jcm10163542
The paper
Van den Borre, C., Rinaldi, M., De Neef, B., Loomans, N. A. J., Nout, E., Van Doorne, L., Naert, I., Politis, C., Schouten, H., Klomp, G., Beckers, L., Freilich, M. M., & Mommaerts, M. Y. (2021). Radiographic Evaluation of Bone Remodeling after Additively Manufactured Subperiosteal Jaw Implantation (AMSJI) in the Maxilla: A One-Year Follow-Up Study. Journal of Clinical Medicine. https://doi.org/10.3390/jcm10163542

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.