Structural Health Monitoring for Advanced Composite Structures: A Review
Open accessAbstract
Condition-based maintenance refers to the installation of permanent sensors on a structure/system. By means of early fault detection, severe damage can be avoided, allowing efficient timing of maintenance works and avoiding unnecessary inspections at the same time. These are the goals for structural health monitoring (SHM). The changes caused by incipient damage on raw data collected by sensors are quite small, and are usually contaminated by noise and varying environmental factors, so the algorithms used to extract information from sensor data need to focus on sensitive damage features. The developments of SHM techniques over the last 20 years have been more related to algorithm improvements than to sensor progress, which essentially have been maintained without major conceptual changes (with regards to accelerometers, piezoelectric wafers, and fiber optic sensors). The main different SHM systems (vibration methods, strain-based fiber optics methods, guided waves, acoustic emission, and nanoparticle-doped resins) are reviewed, and the main issues to be solved are identified. Reliability is the key question, and can only be demonstrated through a probability of detection (POD) analysis. Attention has only been paid to this issue over the last ten years, but now it is a growing trend. Simulation of the SHM system is needed in order to reduce the number of experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vibration-based Damage Identification Methods: A Review and Comparative Study
Fan, W., & Qiao, P. (2011) · Structural Health Monitoring · doi:10.1177/1475921710365419 · Cited by 2,045
(2012) · Cited by 1,059
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Structural Health Monitoring: A Machine Learning Perspective
Farrar, C. R., & Worden, K. (2012) · Wiley eBooks · doi:10.1002/9781118443118 · Cited by 1,014
A carbon nanotube strain sensor for structural health monitoring
Kang, I., Schulz, M. J., Kim, J. H., Shanov, V., & Shi, D. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/3/009 · Cited by 1,004
Review of Guided-wave Structural Health Monitoring
Raghavan, A., & Cesnik, C. E. S. (2007) · The Shock and Vibration Digest · doi:10.1177/0583102406075428 · Cited by 989
Fibre Bragg gratings in structural health monitoring—Present status and applications
Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., & Bhattacharya, D. K. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.04.008 · Cited by 973
Vibration–based structural damage identification
Farrar, C. R., Doebling, S. W., & Nix, D. A. (2001) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2000.0717 · Cited by 865
Structural health monitoring for a wind turbine system: a review of damage detection methods
Ciang, C. C., Lee, J.-R., & Bang, H.-J. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/12/122001 · Cited by 802
Encyclopedia of Structural Health Monitoring
(2009) · Wiley eBooks · doi:10.1002/9780470061626 · Cited by 778
Di Sante, R. (2015) · Sensors · doi:10.3390/s150818666 · Cited by 684
Pitch-catch Active Sensing Methods in Structural Health Monitoring for Aircraft Structures
Ihn, J.-B., & Chang, F.-K. (2008) · Structural Health Monitoring · doi:10.1177/1475921707081979 · Cited by 596
A synthetic time-reversal imaging method for structural health monitoring
Wang, C. H., Rose, J. T., & Chang, F.-K. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/2/020 · Cited by 545
Structural damage diagnosis under varying environmental conditions—Part I: A linear analysis
Yan, A.-M., Kerschen, G., De Boe, P., & Golinval, J.-C. (2005) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2004.12.002 · Cited by 536
Kinet, D., Mégret, P., Goossen, K., Qiu, L., Heider, D., & Caucheteur, C. (2014) · Sensors · doi:10.3390/s140407394 · Cited by 523
Goyal, D., & Pabla, B. S. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-015-9145-0 · Cited by 508
Montalvao, D. (2006) · The Shock and Vibration Digest · doi:10.1177/0583102406065898 · Cited by 500
The State of the Art of Data Science and Engineering in Structural Health Monitoring
Bao, Y., Chen, Z., Wei, S., Xu, Y., Tang, Z., & Li, H. (2019) · Engineering · doi:10.1016/j.eng.2018.11.027 · Cited by 483
Carbon nanotubes: Sensor properties. A review
Zaporotskova, I. V., Boroznina, N. P., Parkhomenko, Y. N., & Kozhitov, L. V. (2016) · Modern Electronic Materials · doi:10.1016/j.moem.2017.02.002 · Cited by 464
Structural health monitoring: Closing the gap between research and industrial deployment
Cawley, P. (2018) · Structural Health Monitoring · doi:10.1177/1475921717750047 · Cited by 423
DAMAGE DETECTION USING THE FREQUENCY-RESPONSE-FUNCTION CURVATURE METHOD
SAMPAIO, R. P. C., MAIA, N. M. M., & SILVA, J. M. M. (1999) · Journal of Sound and Vibration · doi:10.1006/jsvi.1999.2340 · Cited by 402
Health monitoring of aerospace composite structures – Active and passive approach
Staszewski, W. J., Mahzan, S., & Traynor, R. (2009) · Composites Science and Technology · doi:10.1016/j.compscitech.2008.09.034 · Cited by 399
Strategies for guided-wave structural health monitoring
Croxford, A. J., Wilcox, P. D., Drinkwater, B. W., & Konstantinidis, G. (2007) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2007.0048 · Cited by 369
Martinez-Luengo, M., Kolios, A., & Wang, L. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.05.085 · Cited by 310
Fiber Optic Sensors for Structural Health Monitoring of Air Platforms
Guo, H., Xiao, G., Mrad, N., & Yao, J. (2011) · Sensors · doi:10.3390/s110403687 · Cited by 307
Natural computing for mechanical systems research: A tutorial overview
Worden, K., Staszewski, W. J., & Hensman, J. J. (2011) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2010.07.013 · Cited by 288
Luyckx, G., Voet, E., Lammens, N., & Degrieck, J. (2010) · Sensors · doi:10.3390/s110100384 · Cited by 249
Carbon Nanotube Sensing Skins for Spatial Strain and Impact Damage Identification
Loh, K. J., Hou, T.-C., Lynch, J. P., & Kotov, N. A. (2009) · Journal of Nondestructive Evaluation · doi:10.1007/s10921-009-0043-y · Cited by 242
Giurgiutiu, V., & Bao, J. (2004) · Structural Health Monitoring · doi:10.1177/1475921704042697 · Cited by 231
Ciampa, F., & Meo, M. (2010) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2010.08.013 · Cited by 216
Zhang, H., Bilotti, E., & Peijs, T. (2015) · Nanocomposites · doi:10.1080/20550324.2015.1113639 · Cited by 176
Structural Health Monitoring in Composite Structures by Fiber-Optic Sensors
Güemes, A., Fernández-López, A., Díaz-Maroto, P., Lozano, A., & Sierra-Pérez, J. (2018) · Sensors · doi:10.3390/s18041094 · Cited by 169
Self-citationPiezoelectric Wafer Active Sensors – PWAS Transducers
Giurgiutiu, V. (2014) · Structural Health Monitoring with Piezoelectric Wafer Active Sensors · doi:10.1016/b978-0-12-418691-0.00007-1 · Cited by 160
Victor Giurgiutiu, B., & Rogers, C. A. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.316923 · Cited by 158
Janapati, V., Kopsaftopoulos, F. P., Li, F., Lee, S. J., & Chang, F. (2016) · Structural Health Monitoring · doi:10.1177/1475921715627490 · Cited by 139
Gomes, G. F., Méndez, Y. A. D., Alexandrino, P. D. S. L., da Cunha, S. S., & Ancelotti, A. C. (2018) · Composite Structures · doi:10.1016/j.compstruct.2018.05.002 · Cited by 135
New Trends in Structural Health Monitoring
(2013) · CISM International Centre for Mechanical Sciences · doi:10.1007/978-3-7091-1390-5 · Cited by 130
Review on Structural Health Evaluation with Acoustic Emission
Ono, K. (2018) · Applied Sciences · doi:10.3390/app8060958 · Cited by 126
Real time crack detection using mountable comparative vacuum monitoring sensors
Roach, D. P. (2009) · Smart Structures and Systems · doi:10.12989/sss.2009.5.4.317 · Cited by 122
Guided wave propagation and scattering for structural health monitoring of stiffened composites
Memmolo, V., Monaco, E., Boffa, N. D., Maio, L., & Ricci, F. (2017) · Composite Structures · doi:10.1016/j.compstruct.2017.09.067 · Cited by 122
Enhanced Composites Integrity Through Structural Health Monitoring
Victor Giurgiutiu, B., & Soutis, C. (2012) · Applied Composite Materials · doi:10.1007/s10443-011-9247-2 · Cited by 109
Bhalla, S., Gupta, A. K., Bansal, S., & Garg, T. (2009) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x08100384 · Cited by 102
Spatial Sensing Using Electrical Impedance Tomography
Loyola, B. R., Saponara, V. L., Loh, K. J., Briggs, T., O'Bryan, G., & Skinner, J. L. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2253456 · Cited by 102
Structural Health Monitoring of Composite Structures with Piezoelectric-Wafer Active Sensors
Victor Giurgiutiu, B., & Santoni, G. (2011) · AIAA Journal · doi:10.2514/1.j050641 · Cited by 96
Guided wave temperature correction methods in structural health monitoring
Salmanpour, M. S., Khodaei, Z. S., & Aliabadi, M. H. (2016) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x16651155 · Cited by 86
Structural Health Monitoring for Advanced Composite Structures
Aliabadi, M. H., & Khodaei, Z. S. (2017) · Computational and experimental methods in structures · doi:10.1142/q0114 · Cited by 84
A Review of Structural Health Monitoring Techniques as Applied to Composite Structures
David-West, O. S., Amafabia, D.-A. M., Haritos, G. K., & Montalvão, D. (2017) · Bournemouth University Research Online (Bournemouth University) · doi:10.3970/sdhm.2017.011.091 · Cited by 84
Miniaci, M., Mazzotti, M., Radzieński, M., et al. (2019) · Frontiers in Materials · doi:10.3389/fmats.2019.00030 · Cited by 28
A Review of Structural Health Monitoring Techniques as Applied to Composite Structures.
Amafabia, D.-A. M., Montalvão, D., David-West, O., & Haritos, G. K. (2018) · Bournemouth University Research Online (Bournemouth University) · Cited by 27
Aldrin, J. C., Annis, C., Sabbagh, H. A., & Lindgren, E. A. (2016) · AIP conference proceedings · doi:10.1063/1.4940646 · Cited by 25
Takeda, N., Enomoto, K., & YOSHIDA, M. (2013) · Structural Health Monitoring · Cited by 2
Cited by
Structural Health Monitoring in Composite Structures: A Comprehensive Review
Hassani, S., Mousavi, M., & Gandomi, A. H. (2021) · Sensors · doi:10.3390/s22010153 · Cited by 258
Capineri, L., & Bulletti, A. (2021) · doi:10.20944/preprints202103.0347.v2 · Cited by 131
Structural Health Monitoring Damage Detection Systems for Aerospace
(2021) · Springer Aerospace Technology · doi:10.1007/978-3-030-72192-3 · Cited by 92
Hassani, S., Mousavi, M., & Gandomi, A. H. (2022) · Composite Structures · doi:10.1016/j.compstruct.2022.115243 · Cited by 31
Carani, L. B., Martin, T. D., Eze, V. O., & Okoli, O. I. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113843 · Cited by 18
Metadata
- Authors
- Güemes, A., Fernandez-Lopez, A., Pozo, A. R., & Sierra-Pérez, J.
- Venue
- Journal of Composites Science
- Publisher
- MDPI AG
- Published
- 2020-01-27
- Volume
- 4
- Issue
- 1
- Pages
- 13
- ISSN
- 2504-477X (ISSN-L)
- OpenAlex
- W3001075887
- Cited by
- 298
- References
- 51
- FWCI
- 18.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.