Single-Cell Electroporation with Real-Time Impedance Assessment Using a Constriction Microchannel
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The electroporation system can serve as a tool for the intracellular delivery of foreign cargos. However, this technique is presently limited by the inaccurate electric field applied to the single cells and lack of a real-time electroporation metrics subsystem. Here, we reported a microfluidic system for precise and rapid single-cell electroporation and simultaneous impedance monitoring in a constriction microchannel. When single cells (A549) were continuously passing through the constriction microchannel, a localized high electric field was applied on the cell membrane, which resulted in highly efficient (up to 96.6%) electroporation. During a single cell entering the constriction channel, an abrupt impedance drop was noticed and demonstrated to be correlated with the occurrence of electroporation. Besides, while the cell was moving in the constriction channel, the stabilized impedance showed the capability to quantify the electroporation extent. The correspondence of the impedance variation and electroporation was validated by the intracellular delivery of the fluorescence indicator (propidium iodide). Based on the obtained results, this system is capable of precise control of electroporation and real-time, label-free impedance assessment, providing a potential tool for intracellular delivery and other biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most studies focus on high-throughput strategies, processing several mL/min, though some are designed for individual processing or evaluations involving a small number of cells [34].”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [34]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vitro and ex vivo strategies for intracellular delivery
Stewart, M. P., Sharei, A., Ding, X., Sahay, G., Langer, R., & Jensen, K. F. (2016) · Nature · doi:10.1038/nature19764 · Cited by 885 · cited 1×
“Intracellular delivery of foreign cargos is becoming a critical step in biomedical applications, ranging from gene editing to cell-based therapies [1].”
BackgroundMembrane Electroporation and Electropermeabilization: Mechanisms and Models
Kotnik, T., Rems, L., Tarek, M., & Miklavčič, D. (2019) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-052118-115451 · Cited by 813 · cited 4×
“Exposure of a cell to a sufficient electric field can induce cell transmembrane voltage (TMV) far exceeding its resting range and lead to electroporation of the membrane for intracellular delivery [13,42].”
BackgroundInfluentialMammalian cell transfection: the present and the future
Kim, T. K., & Eberwine, J. H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3821-6 · Cited by 678
Research works printed but not linked: 44
- Escoffre, 2010, Gene transfer: How can the biological barriers be overcome?, J. Membr. Biol., 236, 61, 10.1007/s00232-010-9275-0 · DOI
- Nayak, 2010, Progress and prospects: Immune responses to viral vectors, Gene. Ther., 17, 295, 10.1038/gt.2009.148 · DOI · Paper page
- Wegrzyn, 2018, Genome Editing: Insights from Chemical Biology to Support Safe and Transformative Therapeutic Applications, ACS Chem. Biol., 13, 333, 10.1021/acschembio.7b00689 · DOI
- Yarmush, 2014, Electroporation-based technologies for medicine: Principles, applications, and challenges, Annu. Rev. Biomed. Eng., 16, 295, 10.1146/annurev-bioeng-071813-104622 · DOI · Paper page
- Weaver, 1996, Theory of electroporation: A review, Bioelectrochem. Bioenerg., 41, 135, 10.1016/S0302-4598(96)05062-3 · DOI · Paper page
- Sharei, 2013, A vector-free microfluidic platform for intracellular delivery, Proc. Natl. Acad. Sci. USA, 110, 2082, 10.1073/pnas.1218705110 · DOI · Paper page
- Sharei, A., Trifonova, R., Jhunjhunwala, S., Hartoularos, G.C., Eyerman, A.T., Lytton-Jean, A., Angin, M., Sharma, S., Poceviciute, R., and Mao, S. (2015). Ex Vivo cytosolic delivery of functional macromolecules to immune cells. PLoS ONE, 10. · DOI
- Szeto, 2015, Microfluidic squeezing for intracellular antigen loading in polyclonal B-cells as cellular vaccines, Sci. Rep., 5, 10276, 10.1038/srep10276 · DOI
- Ding, X., Stewart, M., Sharei, A., Weaver, J.C., Langer, R.S., and Jensen, K.F. (2017). High-throughput Nuclear Delivery and Rapid Expression of DNA via Mechanical and Electrical Cell-Membrane Disruption. Nat. Biomed. Eng., 1. · DOI · Paper page
- Stewart, 2018, Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts, Chem. Rev., 118, 7409, 10.1021/acs.chemrev.7b00678 · DOI · Paper page
- Kotnik, 2012, Cell membrane electroporation—Part 1: The phenomenon, IEEE Electr. Insul. Mag., 28, 14, 10.1109/MEI.2012.6268438 · DOI · Paper page
- Yang, 2015, Micro-/nano-electroporation for active gene delivery, Curr. Pharm. Des., 21, 6081, 10.2174/1381612821666151027152121 · DOI
- Fox, 2006, Electroporation of cells in microfluidic devices: A review, Anal. Bioanal. Chem., 385, 474, 10.1007/s00216-006-0327-3 · DOI · Paper page
- Wang, 2013, Micro-/nanofluidics based cell electroporation, Biomicrofluidics, 7, 11301, 10.1063/1.4774071 · DOI
- Santra, 2013, Recent Trends on Micro/Nanofluidic Single Cell Electroporation, Micromachines, 4, 333, 10.3390/mi4030333 · doi:10.3390/mi4030333
- Liu, 2019, Self-Powered Intracellular Drug Delivery by a Biomechanical Energy-Driven Triboelectric Nanogenerator, Adv. Mater., 31, e1807795, 10.1002/adma.201807795 · DOI · Paper page
- Zhao, 2016, A Flow-Through Cell Electroporation Device for Rapidly and Efficiently Transfecting Massive Amounts of Cells in vitro and ex vivo, Sci. Rep., 6, 18469, 10.1038/srep18469 · DOI
- Mukherjee, 2018, Combined Numerical and Experimental Investigation of Localized Electroporation-Based Cell Transfection and Sampling, ACS Nano, 12, 12118, 10.1021/acsnano.8b05473 · DOI
- Zheng, 2013, Recent advances in microfluidic techniques for single-cell biophysical characterization, Lab Chip, 13, 2464, 10.1039/c3lc50355k · DOI · Paper page
- 2012, Single cell electroporation using microfluidic devices, Methods. Mol. Biol., 853, 65, 10.1007/978-1-61779-567-1_7 · doi:10.1007/978-1-61779-567-1_7
- Blatz, 2008, Electrophoresis-assisted single-cell electroporation for efficient intracellular delivery, Biomed. Microdevices, 10, 113, 10.1007/s10544-007-9115-x · DOI
- Bellard, 2011, Direct visualization at the single-cell level of siRNA electrotransfer into cancer cells, Proc. Natl. Acad. Sci. USA, 108, 10443, 10.1073/pnas.1103519108 · DOI
- Khine, 2005, A single cell electroporation chip, Lab Chip, 5, 38, 10.1039/b408352k · doi:10.1039/b408352k
- Boukany, 2011, Nanochannel electroporation delivers precise amounts of biomolecules into living cells, Nat. Nanotechnol., 6, 747, 10.1038/nnano.2011.164 · DOI · Paper page
- Gao, 2014, Design of a microchannel-nanochannel-microchannel array based nanoelectroporation system for precise gene transfection, Small, 10, 1015, 10.1002/smll.201300116 · DOI
- Yun, 2019, Nanoinjection system for precise direct delivery of biomolecules into single cells, Lab Chip, 19, 580, 10.1039/C8LC00709H · DOI
- Guo, 2016, Controllable in-situ cell electroporation with cell positioning and impedance monitoring using micro electrode array, Sci. Rep., 6, 31392, 10.1038/srep31392 · doi:10.1038/srep31392
- Huang, 2003, Flow-through micro-electroporation chip for high efficiency single-cell genetic manipulation, Sens. Actuators A Phys., 104, 205, 10.1016/S0924-4247(03)00050-5 · doi:10.1016/s0924-4247(03)00050-5
- Pethig, R. (2010). Review article-dielectrophoresis: Status of the theory, technology, and applications. Biomicrofluidics, 4. · DOI · Paper page
- Wimberger, 2019, Controllable cell manipulation in a microfluidic pipette-tip design using capacitive coupling of electric fields, Lab Chip, 19, 3997, 10.1039/C9LC00927B · DOI
- Kotnik, 2010, Induced transmembrane voltage and its correlation with electroporation-mediated molecular transport, J. Membr. Biol., 236, 3, 10.1007/s00232-010-9279-9 · DOI · Paper page
- Rems, 2016, Tutorial: Electroporation of cells in complex materials and tissue, J. Appl. Phys., 119, 201101, 10.1063/1.4949264 · DOI · Paper page
- Khine, 2007, Single-cell electroporation arrays with real-time monitoring and feedback control, Lab Chip, 7, 457, 10.1039/b614356c · DOI
- Davalos, 2004, Electrical impedance tomography for imaging tissue electroporation, IEEE. Trans. Biomed. Eng., 51, 761, 10.1109/TBME.2004.824148 · DOI
- Ivorra, 2007, In Vivo electrical impedance measurements during and after electroporation of rat liver, Bioelectrochemistry, 70, 287, 10.1016/j.bioelechem.2006.10.005 · doi:10.1016/j.bioelechem.2006.10.005
- Granot, 2009, In Vivo imaging of irreversible electroporation by means of electrical impedance tomography, Phys. Med. Biol., 54, 4927, 10.1088/0031-9155/54/16/006 · DOI
- Azan, 2015, Interpulse multifrequency electrical impedance measurements during electroporation of adherent differentiated myotubes, Bioelectrochemistry, 105, 123, 10.1016/j.bioelechem.2015.05.018 · DOI
- Escobedo, 2015, On-chip electroporation and impedance spectroscopy of single-cells, Sens. Actuators B Chem., 210, 82, 10.1016/j.snb.2014.12.016 · DOI
- Teissie, J. (2017). Critical Electric Field and Transmembrane Voltage for Lipid Pore Formation in Experiments, Springer. Available online: https://link.springer.com/referenceworkentry/10.1007%2F978-3-319-32886-7_77. · doi:10.1007/978-3-319-32886-7_77
- Zhao, 2014, Tumor cell characterization and classification based on cellular specific membrane capacitance and cytoplasm conductivity, Biosens. Bioelectron., 57, 245, 10.1016/j.bios.2014.02.026 · doi:10.1016/j.bios.2014.02.026
- Zhao, 2018, Development of microfluidic impedance cytometry enabling the quantification of specific membrane capacitance and cytoplasm conductivity from 100,000 single cells, Biosens. Bioelectron., 111, 138, 10.1016/j.bios.2018.04.015 · DOI
- Geng, 2010, Flow-through electroporation based on constant voltage for large-volume transfection of cells, J. Control. Release, 144, 91, 10.1016/j.jconrel.2010.01.030 · DOI · Paper page
- Saung, 2016, A Size-Selective Intracellular Delivery Platform, Small, 12, 5873, 10.1002/smll.201601155 · DOI
- Bragos, 2018, In Vitro analysis of various cell lines responses to electroporative electric pulses by means of electrical impedance spectroscopy, Biosens. Bioelectron., 117, 207, 10.1016/j.bios.2018.06.016 · doi:10.1016/j.bios.2018.06.016
Cited by
Ishii-Teshima, M., Maeda, K., Hanauchi, K., Asechi, E., Setyawan, D., Niki, T., Nakashima, K., Kurita, H., Numano, R., & Shibata, T. (2025) · PLOS One · doi:10.1371/journal.pone.0333491 · Cited by 4
Metadata
- Authors
- Ye, Y., Luan, X., Zhang, L., Zhao, W., Cheng, J., Li, M., Zhao, Y., & Huang, C.
- Affiliations
- R&D Center of Healthcare Electronics, Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029, China
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2020-09-16
- Volume
- 11
- Issue
- 9
- Pages
- 856
- ISSN
- 2072-666X
- Cited by
- 32
- References
- 3
- Language
- en
- Funders
- National Natural Science Foundation of China (61774167, 61801477)
- Beijing Municipal Natural Science Foundation (4192062)
- National Key Research and Development Program of China (2018YFC2001100)
- Instrument Development Program of the Chinese Academy of Sciences (YJKYYQ20170045)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.