Cited by 28Neuroscience and Neural EngineeringConducting polymers and applicationsSynthesis and properties of polymers

Towards long-term stable polyimide-based flexible electrical insulation for chronically implanted neural electrodes

Open access
Schander, Andreas, Gancz, Julia, Tintelott, Marcel, Lang, Walter·2021·Micromachines

Abstract

For chronic applications of flexible neural implants, e.g., intracortical probes, the flexible substrate material has to encapsulate the electrical conductors with a long-term stability against the saline environment of the neural tissue. The biocompatible polymer polyimide is often used for this purpose. Due to its chemical inertness, the adhesion between two polyimide layers is, however, a challenge, which can lead to delamination and, finally, to short circuits. The state-of-the-art method to improve the adhesion strength is activating the polyimide surface using oxygen reactive ion etching (O2 RIE). However, the influence of the process variations (etching time, bias power) on the long-term stability is still unclear. Therefore, we establish a test method, where the aging of a gold interdigital structure embedded in two polyimide layers and immersed in saline solution is accelerated using an elevated temperature, mechanical stress and an electrical field. A continuous measurement of a leakage current is used to define the failure state. The results show that the variation of the O2 RIE plasma process has a significant effect on the long-term stability of the test samples. Comparing the two different plasma treatments 0.5 min at 25 W and 1 min at 50 W, the long-term stability could be increased from 20.9 ± 19.1 days to 44.9 ± 18.9 days. This corresponds to more than a doubled lifetime. An ideal solution for the delamination problem is still not available; however, the study shows that the fine-tuning of the fabrication processes can improve the long-term stability of chronically implanted neural electrodes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi12111279

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Leaked substances can disrupt the ionic balance of sodium, potassium, and calcium, leading to excitotoxicity.

    “These leaked substances can also disrupt the ionic balance of essential elements like sodium, potassium, and calcium, leading to excitotoxicity—a pathological process causing neuron damage due to excessive neurotransmitter stimulation.”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Schander et al., 2021

    The Introduction (page unavailable) says that leachables from inadequately processed SU-8 can cause cytotoxicity. It does not say that leaked substances disrupt sodium, potassium, or calcium balance, or that they cause excitotoxicity; the Methods’ discussion of electrolyte concerns an insulation test, not that mechanism. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • Neural tissue might undergo fibrosis in response to chemical exposure.

    “Lastly, in response to chemical exposure, neural tissue might undergo fibrosis, a defensive yet functionally compromising mechanism (Grisold and Carozzi, 2021; Schander et al., 2021; Yin et al., 2021; World Health Organization: WHO, 2023).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Schander et al., 2021

    The Introduction discusses foreign-body responses to neural implants and possible toxic reactions from leachable materials, but it does not say that chemical exposure causes fibrosis in neural tissue. A search of our full copy for fibrosis and chemical exposure found no passage addressing that specific response. (LLM, conf=0.74)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Schander, A., Gancz, J., Tintelott, M., & Lang, W.
Affiliations
University of Bremen (DE)
Corresponding author
Schander, Andreas
Venue
Micromachines
Publisher
MDPI AG
Published
2021-10-20
Volume
12
Issue
11
Pages
1279
ISSN
2072-666X (ISSN-L)
OpenAlex
W3210164395
Cited by
28
References
19
Citations by year
2026: 8 · 2025: 2 · 2024: 8 · 2023: 3 · 2022: 7
FWCI
2.07
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • RWTH Publications (RWTH Aachen) (submittedVersion, other-oa)
Funders
Deutsche Forschungsgemeinschaft (LA 1471/11-2)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Materials Science › Polymers and Plastics › Synthesis and properties of polymers
Keywords
polyimide, electrical insulation, delamination, interlayer bonding, oxygen reactive ion etching, plasma surface treatment, leakage current, accelerated aging test, implant survival

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review