CoChat

Application of Polymethylpentene, an Oxygen Permeable Thermoplastic, for Long-Term on-a-Chip Cell Culture and Organ-on-a-Chip Devices

Open access
Sønstevold, Linda, Czerkies, Maciej, Escobedo-Cousin, Enrique, Blonski, Slawomir, Vereshchagina, Elizaveta · 2023 · Micromachines

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

The applicability of a gas-permeable, thermoplastic material polymethylpentene (PMP) was investigated, experimentally and analytically, for organ-on-a-chip (OoC) and long-term on-a-chip cell cultivation applications. Using a sealed culture chamber device fitted with oxygen sensors, we tested and compared PMP to commonly used glass and polydimethylsiloxane (PDMS). We show that PMP and PDMS have comparable performance for oxygen supply during 4 days culture of epithelial (A549) cells with oxygen concentration stabilizing at 16%, compared with glass control where it decreases to 3%. For the first time, transmission light images of cells growing on PMP were obtained, demonstrating that the optical properties of PMP are suitable for non-fluorescent, live cell imaging. Following the combined transmission light imaging and calcein-AM staining, cell adherence, proliferation, morphology, and viability of A549 cells were shown to be similar on PMP and glass coated with poly-L-lysine. In contrast to PDMS, we demonstrate that a film of PMP as thin as 0.125 mm is compatible with high-resolution confocal microscopy due to its excellent optical properties and mechanical stiffness. PMP was also found to be fully compatible with device sterilization, cell fixation, cell permeabilization and fluorescent staining. We envision this material to extend the range of possible microfluidic applications beyond the current state-of-the-art, due to its beneficial physical properties and suitability for prototyping by different methods. The integrated device and measurement methodology demonstrated in this work are transferrable to other cell-based studies and life-sciences applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi14030532

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The developed culture chamber device. Culture chamber device designed to allow assessment of the PMP material. (a) An exploded-view drawing of the individual parts of the culture chamber device: the lid milled in polycarbonate with O2 sensitive spots attached, the baseplate milled in polycarbonate where the dimensions of the culture chambers are defined (green), a pressure sensitive adhesive (PSA) layer and the gas permeable PMP film. (b) The assembled culture chamber device with the optical fiber inserted into the customized cavity. For better visualization, the polycarbonate parts are made transparent in the right half of the device while they are filled with solid colors in the left half where a cross-sectional view exposes the culture chamber. O2-sensitive spots (blue) and PMP film (pink) are illustrated. (c) An enlarged schematic of the section marked yellow in (b). The cross-sectional view of the device exposing the culture chamber and its components. The 3D device images were created with Inventor 2022, illustrations of microscope objective and adherent cells were created with BioRender.com (accessed on 21 November 2022).
Figure 1 The developed culture chamber device. Culture chamber device designed to allow assessment of the PMP material. (a) An exploded-view drawing of the individual parts of the culture chamber device: the lid milled in polycarbonate with O2 sensitive spots attached, the baseplate milled in polycarbonate where the dimensions of the culture chambers are defined (green), a pressure sensitive adhesive (PSA) layer and the gas permeable PMP film. (b) The assembled culture chamber device with the optical fiber inserted into the customized cavity. For better visualization, the polycarbonate parts are made transparent in the right half of the device while they are filled with solid colors in the left half where a cross-sectional view exposes the culture chamber. O2-sensitive spots (blue) and PMP film (pink) are illustrated. (c) An enlarged schematic of the section marked yellow in (b). The cross-sectional view of the device exposing the culture chamber and its components. The 3D device images were created with Inventor 2022, illustrations of microscope objective and adherent cells were created with BioRender.com (accessed on 21 November 2022).CC BY · PubMed Central
Figure 2 Culture chamber devices with integrated oxygen sensors. Three different designs of the culture chamber device. The main device is the sensor/PMP device, and the two remaining devices were necessary to obtain adequate controls for the experiments with PMP. Each device has in total four (a,b) or five (c) layers. From the top, the device layers are (1) the lid milled in PC (a–c); (2) the baseplate milled in PC (a–c); (3) PSA (a–c); (4) PMP film (a), glass coverslip (b) or PDMS film (c); and (5) the clamping plate (c). See Section 2.2.1 for details. These devices were utilized for oxygen measurements (Section 2.3) and Hif1IF-1α staining (Section 2.4).
Figure 2 Culture chamber devices with integrated oxygen sensors. Three different designs of the culture chamber device. The main device is the sensor/PMP device, and the two remaining devices were necessary to obtain adequate controls for the experiments with PMP. Each device has in total four (a,b) or five (c) layers. From the top, the device layers are (1) the lid milled in PC (a–c); (2) the baseplate milled in PC (a–c); (3) PSA (a–c); (4) PMP film (a), glass coverslip (b) or PDMS film (c); and (5) the clamping plate (c). See Section 2.2.1 for details. These devices were utilized for oxygen measurements (Section 2.3) and Hif1IF-1α staining (Section 2.4).CC BY · PubMed Central
Figure 3 Culture chamber devices without oxygen sensors. Two devices used for the comparison of cell adherence, proliferation and viability (Section 2.5). The only difference from the devices in Figure 2 is in the design of the lids, which are here only support covers to ensure sterility (referred to as “non-sensor lids”). These were designed with either a PMP film (a) or a glass coverslip (b) for the bottom part of the culture chamber.
Figure 3 Culture chamber devices without oxygen sensors. Two devices used for the comparison of cell adherence, proliferation and viability (Section 2.5). The only difference from the devices in Figure 2 is in the design of the lids, which are here only support covers to ensure sterility (referred to as “non-sensor lids”). These were designed with either a PMP film (a) or a glass coverslip (b) for the bottom part of the culture chamber.CC BY · PubMed Central
Figure 4 Oxygen measurements and confocal microscopy. (a) Demonstration of a cell culture device placed on the hot plate set to 37 °C while measuring the oxygen concentration by insertion of the optical fibre into the top cavity for readout of the signal from the fluorescent oxygen-sensitive spots integrated into the lid. (b) Demonstration of the cell culture device standing on the Leica SP5 confocal microscope equipped with environmental chamber set to 37 °C and 5% CO2.
Figure 4 Oxygen measurements and confocal microscopy. (a) Demonstration of a cell culture device placed on the hot plate set to 37 °C while measuring the oxygen concentration by insertion of the optical fibre into the top cavity for readout of the signal from the fluorescent oxygen-sensitive spots integrated into the lid. (b) Demonstration of the cell culture device standing on the Leica SP5 confocal microscope equipped with environmental chamber set to 37 °C and 5% CO2.CC BY · PubMed Central
Figure 5 Cell adherence, proliferation and viability Growth and viability of A549 cells cultured inside the non-sensor/glass (“glass”) or non-sensor/PMP (“PMP”) devices (see Figure 3 and Section 2.2.2 for details on device designs). Both materials were coated with poly-L-lysine prior to seeding the same number of cells on both glass and PMP. Succeeding images show initially adhering cells (at 2 h), assuming of typical elongated morphology (6 h) and successful proliferation on both materials (up to 48 h) during culture at 37 °C and 5% CO2. The last images show the same cells stained with calcein-AM to verify their viability (green fluorescence indicates living cells). Scale bar: 100 µm.
Figure 5 Cell adherence, proliferation and viability Growth and viability of A549 cells cultured inside the non-sensor/glass (“glass”) or non-sensor/PMP (“PMP”) devices (see Figure 3 and Section 2.2.2 for details on device designs). Both materials were coated with poly-L-lysine prior to seeding the same number of cells on both glass and PMP. Succeeding images show initially adhering cells (at 2 h), assuming of typical elongated morphology (6 h) and successful proliferation on both materials (up to 48 h) during culture at 37 °C and 5% CO2. The last images show the same cells stained with calcein-AM to verify their viability (green fluorescence indicates living cells). Scale bar: 100 µm.CC BY · PubMed Central
Figure 6 HIF-1α activation. Activation of the HIF-1α transcription factor in A549 cells cultured in sensor/glass and sensor/PMP devices (see Figure 2 and Section 2.2.1 for details on device designs) after the last measurement of oxygen concentration at 75 h after sealing of devices (see Figure 7). Cells were fixed with formaldehyde before fluorescent staining. The second column shows the presence of activated HIF-1α (green) in numerous cells cultured in the sensor/glass device, while almost none was observed in the sensor/PMP device. Transmitted light images and an overlay with DAPI nuclei staining (blue) show the morphology of a highly confluent cell monolayer. Scale bar: 100 µm.
Figure 6 HIF-1α activation. Activation of the HIF-1α transcription factor in A549 cells cultured in sensor/glass and sensor/PMP devices (see Figure 2 and Section 2.2.1 for details on device designs) after the last measurement of oxygen concentration at 75 h after sealing of devices (see Figure 7). Cells were fixed with formaldehyde before fluorescent staining. The second column shows the presence of activated HIF-1α (green) in numerous cells cultured in the sensor/glass device, while almost none was observed in the sensor/PMP device. Transmitted light images and an overlay with DAPI nuclei staining (blue) show the morphology of a highly confluent cell monolayer. Scale bar: 100 µm.CC BY · PubMed Central
Figure 7 Monitoring of oxygen concentration. Results from monitoring the oxygen concentration during four days of culture of A549 cells in the three different device versions of the culture chamber module, sensor/glass, sensor/PMP and sensor/PDMS (see Figure 2 and Section 2.2.1 for details on device designs). Data are presented as average ± SD, n = 3–5.
Figure 7 Monitoring of oxygen concentration. Results from monitoring the oxygen concentration during four days of culture of A549 cells in the three different device versions of the culture chamber module, sensor/glass, sensor/PMP and sensor/PDMS (see Figure 2 and Section 2.2.1 for details on device designs). Data are presented as average ± SD, n = 3–5.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 25

Metadata

Authors
Sønstevold, L., Czerkies, M., Escobedo-Cousin, E., Blonski, S., & Vereshchagina, E.
Affiliations
  • SINTEF Digital (NO)
  • Institute of Fundamental Technological Research (PL)
  • SINTEF Digital, Department of Smart Sensors and Microsystems, Gaustadalléen 23C, 0373 Oslo, Norway
  • Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego St. 5B, 02-106 Warsaw, Poland
Corresponding author
  • Sønstevold, Linda
  • Czerkies, Maciej
Venue
Micromachines
Publisher
MDPI AG
Published
2023-02-24
Volume
14
Issue
3
Pages
532
ISSN
2072-666X (ISSN-L)
OpenAlex
W4322501630
Cited by
25
References
34
Citations by year
2026: 9 · 2025: 5 · 2024: 9 · 2023: 2
FWCI
1.97
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
Funders
Norwegian Financial Mechanism 2014–2021 (2019/34/H/NZ6/00699)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
polymethylpentene, oxygen permeability, organ-on-a-chip, polydimethylsiloxane, A549 cells, epithelial cells, oxygen supply, live-cell imaging, optical properties, microfluidics, cell viability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.