Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.

Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review

Open access
Cortese, Manuela, Gigliobianco, Maria Rosa, Magnoni, Federico, Censi, Roberta, Di Martino, Piera·2020·Molecules

Abstract

In recent decades, mass spectrometry techniques, particularly when combined with separation methods such as high-performance liquid chromatography, have become increasingly important in pharmaceutical, bio-analytical, environmental, and food science applications because they afford high selectivity and sensitivity. However, mass spectrometry has limitations due to the matrix effects (ME), which can be particularly marked in complex mixes, when the analyte co-elutes together with other molecules, altering analysis results quantitatively. This may be detrimental during method validation, negatively affecting reproducibility, linearity, selectivity, accuracy, and sensitivity. Starting from literature and own experience, this review intends to provide a simple guideline for selecting the best operative conditions to overcome matrix effects in LC-MS techniques, to obtain the best result in the shortest time. The proposed methodology can be of benefit in different sectors, such as pharmaceutical, bio-analytical, environmental, and food sciences. Depending on the required sensitivity, analysts may minimize or compensate for ME. When sensitivity is crucial, analysis must try to minimize ME by adjusting MS parameters, chromatographic conditions, or optimizing clean-up. On the contrary, to compensate for ME analysts should have recourse to calibration approaches depending on the availability of blank matrix. When blank matrices are available, calibration can occur through isotope labeled internal standards and matrix matched calibration standards; conversely, when blank matrices are not available, calibration can be performed through isotope labeled internal standards, background subtraction, or surrogate matrices. In any case, an adjusting of MS parameters, chromatographic conditions, or a clean-up are necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/molecules25133047

Cites

115 of 115 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 115 references

Cited by

See all 280

Metadata

Authors
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P.
Venue
Molecules
Publisher
MDPI AG
Published
2020-07-03
Volume
25
Issue
13
Pages
3047
ISSN
1420-3049 (ISSN-L)
OpenAlex
W3039439932
Cited by
280
References
115
FWCI
7.78
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review. https://app.cochat.ai/papers/10.3390/molecules25133047
The paper
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020). Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review. Molecules. https://doi.org/10.3390/molecules25133047

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.