The DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.
Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review
Open accessAbstract
In recent decades, mass spectrometry techniques, particularly when combined with separation methods such as high-performance liquid chromatography, have become increasingly important in pharmaceutical, bio-analytical, environmental, and food science applications because they afford high selectivity and sensitivity. However, mass spectrometry has limitations due to the matrix effects (ME), which can be particularly marked in complex mixes, when the analyte co-elutes together with other molecules, altering analysis results quantitatively. This may be detrimental during method validation, negatively affecting reproducibility, linearity, selectivity, accuracy, and sensitivity. Starting from literature and own experience, this review intends to provide a simple guideline for selecting the best operative conditions to overcome matrix effects in LC-MS techniques, to obtain the best result in the shortest time. The proposed methodology can be of benefit in different sectors, such as pharmaceutical, bio-analytical, environmental, and food sciences. Depending on the required sensitivity, analysts may minimize or compensate for ME. When sensitivity is crucial, analysis must try to minimize ME by adjusting MS parameters, chromatographic conditions, or optimizing clean-up. On the contrary, to compensate for ME analysts should have recourse to calibration approaches depending on the availability of blank matrix. When blank matrices are available, calibration can occur through isotope labeled internal standards and matrix matched calibration standards; conversely, when blank matrices are not available, calibration can be performed through isotope labeled internal standards, background subtraction, or surrogate matrices. In any case, an adjusting of MS parameters, chromatographic conditions, or a clean-up are necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Chen, L., Xu, S., & Li, J. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00084a · Cited by 1,753
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
The IUPAC Compendium of Chemical Terminology: The Gold Book
(2025) · International Union of Pure and Applied Chemistry (IUPAC) eBooks · doi:10.1351/goldbook · Cited by 1,382
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Electrospray mass spectrometry of phospholipids
Pulfer, M., & Murphy, R. C. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10061 · Cited by 906
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
Chambers, E., Wagrowski-Diehl, D. M., Lu, Z., & Mazzeo, J. R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.030 · Cited by 776
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Owen, D. H., & Katz, D. F. (1999) · Contraception · doi:10.1016/s0010-7824(99)00010-4 · Cited by 718
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00574-9 · Cited by 600
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530
Ferrer, C., Lozano, A., Agüera, A., Girón, A. J., & Fernández-Alba, A. R. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.033 · Cited by 485
Vanderford, B. J., Pearson, R. A., Rexing, D. J., & Snyder, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034210g · Cited by 461
Malachová, A., Sulyok, M., Beltrán, E., Berthiller, F., & Krska, R. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.037 · Cited by 444
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Niessen, W. M. A., Manini, P., & Andreoli, R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20097 · Cited by 435
Antignac, J., Wasch, K. D., Monteau, F., Brabander, H. D., Andre, F., & Bizec, B. L. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.055 · Cited by 420
Sulyok, M., Krska, R., & Schuhmacher, R. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1542-2 · Cited by 409
Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00072-4 · Cited by 364
Mei, H., Hsieh, Y., Nardo, C., Xu, X., Wang, S., Ng, K., & Korfmacher, W. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.876 · Cited by 350
Relating Electrospray Ionization Response to Nonpolar Character of Small Peptides
Cech, N. B., & Enke, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac9914869 · Cited by 342
Yang, Y., Lu, L., Zhang, J., Yang, Y., Wu, Y., & Shao, B. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.074 · Cited by 342
Stahnke, H., Kittlaus, S., Kempe, G., & Alder, L. (2012) · Analytical Chemistry · doi:10.1021/ac202661j · Cited by 341
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry
Kruve, A., Künnapas, A., Herodes, K., & Leito, I. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.01.077 · Cited by 322
Analysis of Nonvolatile Lipids by Mass Spectrometry
Murphy, R. C., Fiedler, J., & Hevko, J. (2001) · Chemical Reviews · doi:10.1021/cr9900883 · Cited by 304
Nguyen, H. P., & Schug, K. A. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700630 · Cited by 275
LITTLE, J., WEMPE, M., & BUCHANAN, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.02.011 · Cited by 256
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Liang, H. R., Foltz, R. L., Meng, M., & Bennett, P. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1268 · Cited by 247
Quantitative analysis of endogenous compounds
Thakare, R., Chhonker, Y. S., Gautam, N., Alamoudi, J. A., & Alnouti, Y. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.06.017 · Cited by 231
Xia, Y., & Jemal, M. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4121 · Cited by 219
Benijts, T., Dams, R., Lambert, W., & De Leenheer, A. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2003.12.022 · Cited by 216
Recent developments and applications of microextraction techniques in drug analysis
Kataoka, H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3076-2 · Cited by 208
Huang, L. C., Zheng, N., Zheng, B. Q., Wen, F., Cheng, J. B., Han, R. W., Xu, X. M., Li, S. L., & Wang, J. Q. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2013.09.047 · Cited by 202
Kloepfer, A., Quintana, J. B., & Reemtsma, T. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.11.101 · Cited by 198
Han, J., Liu, Y., Wang, R., Yang, J., Ling, V., & Borchers, C. H. (2015) · Analytical Chemistry · doi:10.1021/ac503816u · Cited by 188
Hewavitharana, A. K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.11.047 · Cited by 179
Baduel, C., Mueller, J. F., Tsai, H., & Gomez Ramos, M. J. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.040 · Cited by 176
Ismaiel, O. A., Zhang, T., Jenkins, R. G., & Karnes, H. T. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.10.012 · Cited by 173
Bioanalytical method development and validation: Critical concepts and strategies
Moein, M. M., El Beqqali, A., & Abdel-Rehim, M. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2016.09.028 · Cited by 173
Romero-González, R., Garrido Frenich, A., Martínez Vidal, J. L., Prestes, O. D., & Grio, S. L. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.01.034 · Cited by 165
Le, A., Ng, A., Kwan, T., Cusmano-Ozog, K., & Cowan, T. M. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.11.017 · Cited by 159
Berg, T., & Strand, D. H. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.081 · Cited by 158
Pucci, V., Palma, S. D., Alfieri, A., Bonelli, F., & Monteagudo, E. S. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2009.05.037 · Cited by 149
Recent developments in sample-pretreatment techniques for mass spectrometry-based metabolomics
Raterink, R.-J., Lindenburg, P. W., Vreeken, R. J., Ramautar, R., & Hankemeier, T. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.06.003 · Cited by 144
Nováková, L. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.087 · Cited by 136
Characterization and classification of matrix effects in biological samples analyses
Marchi, I., Viette, V., Badoud, F., Fathi, M., Saugy, M., Rudaz, S. L., & Veuthey, J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.061 · Cited by 135
Wang, Y., Ye, D., Zhu, B., Wu, G., & Duan, C. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2014.04.064 · Cited by 129
Rejczak, T. P., & Tuzimski, T. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.08.095 · Cited by 123
Tomasini, D., Sampaio, M. R. F., Caldas, S. S., Garda‐Buffon, J., Duarte, F. A., & Prímel, E. G. (2012) · Talanta · doi:10.1016/j.talanta.2012.05.068 · Cited by 121
Keski‐Rahkonen, P., Desai, R., Jimenez, M., Harwood, D. T., & Handelsman, D. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01042 · Cited by 115
Gachet, M. S., Rhyn, P., Bosch, O. G., Quednow, B. B., & Gertsch, J. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.11.001 · Cited by 114
Kittlaus, S., Schimanke, J., Kempe, G., & Speer, K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.09.054 · Cited by 112
Xiang, X., Han, Y., Neuvonen, M., Laitila, J., Neuvonen, P. J., & Niemi, M. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.11.019 · Cited by 112
Bobeldijk, I., Hekman, M., der Weij, J. D. V.-V., Coulier, L., Ramaker, R., Kleemann, R., Kooistra, T., Rubingh, C. M., Freidig, A. P., & Verheij, E. R. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.05.008 · Cited by 112
Wu, J., Qian, X., Yang, Z., & Zhang, L. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.12.074 · Cited by 111
Bakhtiar, R., & Majumdar, T. K. (2006) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2006.10.002 · Cited by 106
Advances in sample preparation and analytical techniques for lipidomics study of clinical samples
Teo, C. C., Chong, W. P. K., Tan, E., Basri, N. B., Low, Z. J., & Ho, Y. S. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.10.010 · Cited by 97
Jin, Y., Zhang, J., Zhao, W., Zhang, W., Wang, L., Zhou, J., & Li, Y. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.11.026 · Cited by 93
Redruello, B., Ladero, V., del Río, B., Fernández, M., Martín, M. C., & Álvarez, M. A. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.08.040 · Cited by 87
Quantification of Urinary Albumin by Using Protein Cleavage and LC-MS/MS
Seegmiller, J. C., Barnidge, D. R., Burns, B. E., Larson, T. S., Lieske, J. C., & Kumar, R. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.115543 · Cited by 85
Steiner, C., von Eckardstein, A., & Rentsch, K. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.08.045 · Cited by 85
Recent applications of liquid chromatography–mass spectrometry in natural products bioanalysis
Xing, J., Xie, C., & Lou, H. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.01.010 · Cited by 85
Salatti-Dorado, J. Á., Caballero-Casero, N., Sicilia, M. D., Lunar, M. L., & Rubio, S. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.026 · Cited by 82
Evans, C., Bogan, K. L., Song, P., Burant, C. F., Kennedy, R. T., & Brenner, C. (2010) · BMC Chemical Biology · doi:10.1186/1472-6769-10-2 · Cited by 81
Mirejovsky, D., Patel, A. S., Rodriguez, D. D., & Hunt, T. (1991) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1991.tb02837.x · Cited by 76
Rezk, M. R., Bendas, E. R., Basalious, E. B., & Karim, I. A. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.05.016 · Cited by 76
The influence of electrospray ion source design on matrix effects
Stahnke, H., Kittlaus, S., Kempe, G., Hemmerling, C., & Alder, L. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3047 · Cited by 74
Yarita, T., Aoyagi, Y., & Otake, T. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.03.075 · Cited by 72
HybridSPE: A novel technique to reduce phospholipid-based matrix effect in LC-ESI-MS Bioanalysis
Rahman, M., Ahmad, S., Kalra, H., Gupta, A., Raut, B. B., & Hussain, A. (2012) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.103234 · Cited by 72
Montuschi, P., Martello, S., Felli, M., Mondino, C., & Chiarotti, M. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1682 · Cited by 68
Advanced Liquid Chromatography−Mass Spectrometry Interface Based on Electron Ionization
Cappiello, A., Famiglini, G., Pierini, E., Palma, P., & Trufelli, H. (2007) · Analytical Chemistry · doi:10.1021/ac070468l · Cited by 67
Rodríguez-Gómez, R., Jiménez-Díaz, I., Zafra‐Gómez, A., Ballesteros, O., & Navalón, A. (2014) · Talanta · doi:10.1016/j.talanta.2014.07.047 · Cited by 66
Simultaneous determination of metformin and vildagliptin in human plasma by a HILIC–MS/MS method
Pontarolo, R., Gimenez, A. C., de Francisco, T. M. G., Ribeiro, R. P., Pontes, F. L. D., & Gasparetto, J. C. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.06.023 · Cited by 60
Kang, J., Hick, L. A., & Price, W. E. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3311 · Cited by 59
Ahn, S., Lee, S., Lee, J., & Kim, B. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.05.114 · Cited by 57
LC/ESI-tandem mass spectrometric determination of bile acid 3-sulfates in human urine
Goto, T., Myint, K. T., Sato, K., Wada, O., Kakiyama, G., Iida, T., Hishinuma, T., Mano, N., & Goto, J. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.08.013 · Cited by 57
The impact of phospholipids and phospholipid removal on bioanalytical method performance
Carmical, J., & Brown, S. (2016) · Biomedical Chromatography · doi:10.1002/bmc.3686 · Cited by 56
Hényková, E., Vranová, H. P., Amakorová, P., Pospíšil, T., Žukauskaitė, A., Vlčková, M., Urbánek, L., Novák, O., Mareš, J., Kaňovský, P., et al. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.02.009 · Cited by 54
Beltrán, E., Ibáñez, M., Sancho, J. V., & Hernández, F. J. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.07.069 · Cited by 52
Ding, J., Jin, G., Jin, G., Shen, A., Guo, Z., Yu, B., Jiao, Y., Yan, J., & Liang, X. (2016) · Food Analytical Methods · doi:10.1007/s12161-016-0468-8 · Cited by 50
Yoon, S. H., Kim, M., Kim, S. H., Park, H. M., Pyo, H., Lee, Y., Lee, K., & Hong, J. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.04.007 · Cited by 48
Endogenous ethanolamide analysis in human plasma using HPLC tandem MS with electrospray ionization
Palandra, J., Prusakiewicz, J. J., Ozer, J. S., Zhang, Y., & Heath, T. G. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.05.043 · Cited by 45
Franco, P., Porru, E., Fiori, J., Gioiello, A., Cerra, B., Roda, G., Caliceti, C., Simoni, P., & Roda, A. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.11.038 · Cited by 44
Ongay, S., Hendriks, G., Hermans, J. H., van den Berge, M., ten Hacken, N. H. T., van de Merbel, N. C., & Bischoff, R. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.035 · Cited by 43
Tulipani, S., Cubillos, L. X. M., Jáuregui, O., Llorach, R., García‐Fuentes, E., Tinahones, F. J., & Andrés‐Lacueva, C. (2015) · Analytical Chemistry · doi:10.1021/ac503031d · Cited by 43
Drug confirmation by mass spectrometry: Identification criteria and complicating factors
Yuan, C., Chen, D., & Wang, S. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.08.021 · Cited by 42
Rodríguez-Gómez, R., Dorival–García, N., Zafra‐Gómez, A., Camino-Sánchez, F. J., Ballesteros, O., & Navalón, A. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.04.022 · Cited by 41
Isokawa, M., Kanamori, T., Funatsu, T., & Tsunoda, M. (2014) · Bioanalysis · doi:10.4155/bio.14.173 · Cited by 39
Shama, N., Bai, S. W., Chung, B. C., & Jung, B. H. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.01.027 · Cited by 39
Moreno‐González, D., Rodríguez-Ramírez, R., del Olmo‐Iruela, M., & García-Campaña, A. M. (2017) · Talanta · doi:10.1016/j.talanta.2017.02.045 · Cited by 39
Vilhena, R. D. O., Pontes, F. L. D., Marson, B. M., et al. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.06.030 · Cited by 38
Mizuno, K., & Kataoka, H. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.04.020 · Cited by 37
Bathena, S. P., Huang, J., Nunn, M. E., Miyamoto, T., Parrish, L. C., Lang, M., McVaney, T. P., Toews, M. L., CERUTIS, D. R., & Alnouti, Y. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.05.041 · Cited by 35
Nurit, E., Lyan, B., Piquet, A., Branlard, G., & Pujos‐Guillot, E. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8553-1 · Cited by 33
Genangeli, M., Caprioli, G., Cortese, M., Laus, F., Matteucci, M., Petrelli, R., Ricciutelli, M., Sagratini, G., Sartori, S., & Vittori, S. (2016) · Journal of Mass Spectrometry · doi:10.1002/jms.3896 · Cited by 33
Self-citationKhamis, M. M., Adamko, D. J., & El‐Aneed, A. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.08.007 · Cited by 32
González, O., Vliet, M. V., Damen, C. W. N., van der Kloet, F. M., Vreeken, R. J., & Hankemeier, T. (2015) · Analytical Chemistry · doi:10.1021/ac504268y · Cited by 29
An UPLC–MS/MS method for quantitative profiling of bile acids in sea lamprey plasma and tissues
Wang, H., Yeh, C., Li, K., Chung‐Davidson, Y., & Li, W. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.12.018 · Cited by 29
Yang, Z., Cai, Q., Chen, N., Zhou, X., & Hong, J. (2016) · RSC Advances · doi:10.1039/c5ra26695e · Cited by 22
Meulder, M. D., Waldron, M. P., Li, L., Peay, M., Tingler, M. J., Hidy, B. J., Verhaeghe, T., & Jenkins, R. G. (2016) · Bioanalysis · doi:10.4155/bio.16.27 · Cited by 22
Bylda, C., Thiele, R., Kobold, U., & Volmer, D. A. (2015) · Drug Testing and Analysis · doi:10.1002/dta.1781 · Cited by 21
Minato, K., Suzuki, M., Nagao, H., Suzuki, R., & Ochiai, H. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.08.047 · Cited by 21
Zhu, B., Liu, F., Xi-tuo, L., Wang, Y., Gu, X., Dai, J., Wang, G., Cheng, Y., & Yan, C. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400899 · Cited by 21
Leonhardt, J., Teutenberg, T., Buschmann, G., Gassner, O. G., & Schmidt, T. C. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9911-3 · Cited by 16
A liquid chromatography-mass spectrometry assay for quantification of Exendin[9-39] in human plasma
Lasaosa, M., Patel, P., Givler, S., et al. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.12.010 · Cited by 13
Giri, P., Patel, N., Patel, B. G., Patel, H., Bahekar, R. H., Srinivas, N. R., Patel, P., & Desai, R. C. (2017) · Biomedical Chromatography · doi:10.1002/bmc.3984 · Cited by 2
Cited by
Kourtchev, I., Hellebust, S., Heffernan, E., Wenger, J., Towers, S., Diapouli, E., & Eleftheriadis, K. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.155496 · Cited by 68
Santana-Mayor, Á., Herrera-Herrera, A. V., Rodríguez-Ramos, R., Socas-Rodríguez, B., & Rodríguez-Delgado, M. Á. (2021) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c07686 · Cited by 59
Dal Bosco, C., Mariani, F., & Gentili, A. (2022) · Molecules · doi:10.3390/molecules27030908 · Cited by 28
Folorunsho, O., Bogush, A., & Kourtchev, I. (2023) · Analytical Methods · doi:10.1039/d2ay01574a · Cited by 21
Metadata
- Authors
- Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P.
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2020-07-03
- Volume
- 25
- Issue
- 13
- Pages
- 3047
- ISSN
- 1420-3049 (ISSN-L)
- OpenAlex
- W3039439932
- Cited by
- 280
- References
- 115
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.