Guide to Semi-Quantitative Non-Targeted Screening Using LC/ESI/HRMS
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Non-targeted screening (NTS) with reversed phase liquid chromatography electrospray ionization high resolution mass spectrometry (LC/ESI/HRMS) is increasingly employed as an alternative to targeted analysis; however, it is not possible to quantify all compounds found in a sample with analytical standards. As an alternative, semi-quantification strategies are, or at least should be, used to estimate the concentrations of the unknown compounds before final decision making. All steps in the analytical chain, from sample preparation to ionization conditions and data processing can influence the signals obtained, and thus the estimated concentrations. Therefore, each step needs to be considered carefully. Generally, less is more when it comes to choosing sample preparation as well as chromatographic and ionization conditions in NTS. By combining the positive and negative ionization mode, the performance of NTS can be improved, since different compounds ionize better in one or the other mode. Furthermore, NTS gives opportunities for retrospective analysis. In this tutorial, strategies for semi-quantification are described, sources potentially decreasing the signals are identified and possibilities to improve NTS are discussed. Additionally, examples of retrospective analysis are presented. Finally, we present a checklist for carrying out semi-quantitative NTS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, M., Carver, J. J., Phelan, V. V., Sanchez, L. M., Garg, N., Peng, Y., Nguyen, D. D., Watrous, J., Kapono, C. A., Luzzatto-Knaan, T., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3597 · Cited by 4,629
Identifying Small Molecules via High Resolution Mass Spectrometry: Communicating Confidence
Schymanski, E. L., Jeon, J., Gulde, R., Fenner, K., Ruff, M., Singer, H. P., & Hollender, J. (2014) · Environmental Science & Technology · doi:10.1021/es5002105 · Cited by 4,519 · cited 1×
“Still, even after this data pre-processing step, there are usually too many peaks left for all to be confidently (to level 1 and 2 according to the Schymanski scale) identified, [7] thus the peaks are prioritized before the ones with highest priority are fully identified with analytical standards [1,3].”
BackgroundWater Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
Systematic classification of unknown metabolites using high-resolution fragmentation mass spectra
Dührkop, K., Nothias, L.-F., Fleischauer, M., Reher, R., Ludwig, M., Hoffmann, M. A., Petras, D., Gerwick, W. H., Rousu, J., Dorrestein, P. C., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-0740-8 · Cited by 860 · cited 1×
“However, the use of high resolving instruments has improved the mass accuracy obtained, and thereby made it easier to assign a tentative structure based on the exact mass and MS/MS fragmentation spectra [1,10,34].”
BackgroundSHOU, W., & NAIDONG, W. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.01.011 · Cited by 136
Research works printed but not linked: 60
- Hollender, 2017, Nontarget Screening with High Resolution Mass Spectrometry in the Environment: Ready to Go?, Environ. Sci. Technol., 51, 11505, 10.1021/acs.est.7b02184 · DOI · Paper page
- Kruve, 2018, Semi-quantitative Non-target Analysis of Water with Liquid Chromatography/High-resolution Mass Spectrometry: How Far Are We?, Rapid Commun. Mass Spectrom., 33, 54, 10.1002/rcm.8208 · DOI
- Bletsou, 2015, Targeted and Non-Targeted Liquid Chromatography-Mass Spectrometric Workflows for Identification of Transformation Products of Emerging Pollutants in the Aquatic Environment, TrAC Trends Anal. Chem., 66, 32, 10.1016/j.trac.2014.11.009 · DOI · Paper page
- Pluskal, T., Castillo, S., Villar-Briones, A., and Orešič, M. (2010). MZmine 2: Modular Framework for Processing, Visualizing, and Analyzing Mass Spectrometry-Based Molecular Profile Data. BMC Bioinform., 11. · DOI · Paper page
- Escher, 2011, Recent Advances in Environmental Risk Assessment of Transformation Products, Environ. Sci. Technol., 45, 3835, 10.1021/es1030799 · DOI · Paper page
- Kiefer, K., Müller, A., Singer, H., and Hollender, J. (2019). New Relevant Pesticide Transformation Products in Groundwater Detected Using Target and Suspect Screening for Agricultural and Urban Micropollutants with LC-HRMS. Water Res., 165. · DOI · Paper page
- Liigand, J., Wang, T., Kellogg, J., Smedsgaard, J., Cech, N., and Kruve, A. (2020). Quantification for Non-Targeted LC/MS Screening without Standard Substances. Sci. Rep., 10. · DOI · Paper page
- Kruve, 2020, Strategies for Drawing Quantitative Conclusions from Nontargeted Liquid Chromatography–High-Resolution Mass Spectrometry Analysis, Anal. Chem., 92, 4691, 10.1021/acs.analchem.9b03481 · DOI · Paper page
- Cech, 2001, Practical Implications of Some Recent Studies in Electrospray Ionization Fundamentals, Mass Spectrom. Rev., 20, 362, 10.1002/mas.10008 · DOI · Paper page
- Liigand, 2014, Effect of Mobile Phase on Electrospray Ionization Efficiency, J. Am. Soc. Mass Spectrom., 25, 1853, 10.1007/s13361-014-0969-x · DOI
- Kostiainen, 2009, Effect of Eluent on the Ionization Process in Liquid Chromatography–Mass Spectrometry, J. Chromatogr. A, 1216, 685, 10.1016/j.chroma.2008.08.095 · DOI · Paper page
- Kiontke, A., Oliveira-Birkmeier, A., Opitz, A., and Birkemeyer, C. (2016). Electrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent PH and Instrumental Configuration. PLoS ONE, 11. · doi:10.1371/journal.pone.0167502
- Page, 2007, Ionization and Transmission Efficiency in an Electrospray Ionization—Mass Spectrometry Interface, J. Am. Soc. Mass Spectrom., 18, 1582, 10.1016/j.jasms.2007.05.018 · DOI · Paper page
- Pieke, 2017, A Framework to Estimate Concentrations of Potentially Unknown Substances by Semi-Quantification in Liquid Chromatography Electrospray Ionization Mass Spectrometry, Anal. Chim. Acta, 975, 30, 10.1016/j.aca.2017.03.054 · DOI
- Espinosa, 2015, Exploring Analyte Response in an ESI-MS System with Different Chemometric Tools, Chemom. Intell. Lab. Syst., 146, 120, 10.1016/j.chemolab.2015.05.004 · DOI
- Aalizadeh, 2019, Development and Application of Retention Time Prediction Models in the Suspect and Non-Target Screening of Emerging Contaminants, J. Hazard. Mater., 363, 277, 10.1016/j.jhazmat.2018.09.047 · DOI · Paper page
- Kruve, 2021, Benchmarking of the Quantification Approaches for the Non-Targeted Screening of Micropollutants and Their Transformation Products in Groundwater, Anal. Bioanal. Chem., 413, 1549, 10.1007/s00216-020-03109-2 · DOI
- Chalcraft, 2009, Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical Standards, Anal. Chem., 81, 2506, 10.1021/ac802272u · DOI · Paper page
- Dahal, 2011, Small Molecule Quantification by Liquid Chromatography-Mass Spectrometry for Metabolites of Drugs and Drug Candidates, Drug Metab. Dispos., 39, 2355, 10.1124/dmd.111.040865 · doi:10.1124/dmd.111.040865
- Oss, 2010, Electrospray Ionization Efficiency Scale of Organic Compounds, Anal. Chem., 82, 2865, 10.1021/ac902856t · DOI · Paper page
- Huffman, 2012, Effect of Polar Protic and Polar Aprotic Solvents on Negative-Ion Electrospray Ionization and Chromatographic Separation of Small Acidic Molecules, Anal. Chem., 84, 9942, 10.1021/ac302397b · DOI
- Park, 2020, Applications of Machine Learning to In Silico Quantification of Chemicals without Analytical Standards, J. Chem. Inf. Modeling, 60, 2718, 10.1021/acs.jcim.9b01096 · DOI
- Mayhew, 2020, New Approach Combining Molecular Fingerprints and Machine Learning to Estimate Relative Ionization Efficiency in Electrospray Ionization, ACS Omega, 5, 9510, 10.1021/acsomega.0c00732 · DOI
- Liigand, P., Liigand, J., Kaupmees, K., and Kruve, A. (2021). 30 Years of Research on ESI/MS Response: Trends, Contradictions and Applications. Anal. Chim. Acta, 1152. · DOI
- Brunner, A.M., Bertelkamp, C., Dingemans, M.M.L., Kolkman, A., Wols, B., Harmsen, D., Siegers, W., Martijn, B.J., Oorthuizen, W.A., and ter Laak, T.L. (2020). Integration of Target Analyses, Non-Target Screening and Effect-Based Monitoring to Assess OMP Related Water Quality Changes in Drinking Water Treatment. Sci. Total Environ., 705. · DOI
- Schymanski, 2014, Strategies to Characterize Polar Organic Contamination in Wastewater: Exploring the Capability of High Resolution Mass Spectrometry, Environ. Sci. Technol., 48, 1811, 10.1021/es4044374 · DOI · Paper page
- Sørensen, L., McCormack, P., Altin, D., Robson, W.J., Booth, A.M., Faksness, L.-G., Rowland, S.J., and Størseth, T.R. (2019). Establishing a Link between Composition and Toxicity of Offshore Produced Waters Using Comprehensive Analysis Techniques—A Way Forward for Discharge Monitoring?. Sci. Total Environ., 694. · doi:10.1016/j.scitotenv.2019.133682
- Blum, 2017, Non-Target Screening and Prioritization of Potentially Persistent, Bioaccumulating and Toxic Domestic Wastewater Contaminants and Their Removal in on-Site and Large-Scale Sewage Treatment Plants, Sci. Total Environ., 575, 265, 10.1016/j.scitotenv.2016.09.135 · DOI
- Baz-Lomba, J.A., Salvatore, S., Gracia-Lor, E., Bade, R., Castiglioni, S., Castrignanò, E., Causanilles, A., Hernandez, F., Kasprzyk-Hordern, B., and Kinyua, J. (2016). Comparison of Pharmaceutical, Illicit Drug, Alcohol, Nicotine and Caffeine Levels in Wastewater with Sale, Seizure and Consumption Data for 8 European Cities. BMC Public Health, 16. · DOI · Paper page
- Rousis, 2016, Wastewater-Based Epidemiology To Monitor Synthetic Cathinones Use in Different European Countries, Environ. Sci. Technol., 50, 10089, 10.1021/acs.est.6b02644 · DOI · Paper page
- Schulze, 2017, Assessment of a Novel Device for Onsite Integrative Large-Volume Solid Phase Extraction of Water Samples to Enable a Comprehensive Chemical and Effect-Based Analysis, Sci. Total Environ., 581–582, 350, 10.1016/j.scitotenv.2016.12.140 · DOI
- Dzuman, 2015, Multi-Analyte High Performance Liquid Chromatography Coupled to High Resolution Tandem Mass Spectrometry Method for Control of Pesticide Residues, Mycotoxins, and Pyrrolizidine Alkaloids, Anal. Chim. Acta, 863, 29, 10.1016/j.aca.2015.01.021 · DOI
- Kafeenah, 2019, Effect of Mobile Phase PH on the Electrospray Ionization Efficiency and Qualitative Analysis of Pharmaceuticals in ESI + LC-MS/MS, J. Chromatogr. Sci., 57, 847, 10.1093/chromsci/bmz061 · doi:10.1093/chromsci/bmz061
- Zhou, 2000, Protonation in Electrospray Mass Spectrometry: Wrong-Way-Round or Right-Way-Round?, J. Am. Soc. Mass Spectrom., 11, 961, 10.1016/S1044-0305(00)00174-4 · DOI
- Mallet, 2004, A Study of Ion Suppression Effects in Electrospray Ionization from Mobile Phase Additives and Solid-Phase Extracts, Rapid Commun. Mass Spectrom., 18, 49, 10.1002/rcm.1276 · DOI · Paper page
- Snyder, L.R., Kirkland, J.J., and Glajch, J.L. (1997). Practical HPLC Method Development, Wiley. [2nd ed.]. · DOI · Paper page
- Ojakivi, 2018, Modifying the Acidity of Charged Droplets, ChemistrySelect, 3, 335, 10.1002/slct.201702269 · doi:10.1002/slct.201702269
- Rebane, 2019, Ionization Efficiency Ladders as Tools for Choosing Ionization Mode and Solvent in Liquid Chromatography/Mass Spectrometry, Rapid Commun. Mass Spectrom., 33, 1834, 10.1002/rcm.8545 · doi:10.1002/rcm.8545
- Colizza, 2016, Acetonitrile Ion Suppression in Atmospheric Pressure Ionization Mass Spectrometry, J. Am. Soc. Mass Spectrom., 27, 1796, 10.1007/s13361-016-1466-1 · DOI
- Buszewski, 2012, Artifacts in Liquid-Phase Separations–System, Solvent, and Impurity Peaks, Chem. Rev., 112, 2629, 10.1021/cr200182j · doi:10.1021/cr200182j
- Srbek, 2005, System Peaks and Their Positive and Negative Aspects in Chromatographic Techniques, J. Sep. Sci., 28, 1263, 10.1002/jssc.200500168 · doi:10.1002/jssc.200500168
- Oberacher, H., Sasse, M., Antignac, J.-P., Guitton, Y., Debrauwer, L., Jamin, E.L., Schulze, T., Krauss, M., Covaci, A., and Caballero-Casero, N. (2020). A European Proposal for Quality Control and Quality Assurance of Tandem Mass Spectral Libraries. Environ. Sci. Eur., 32. · DOI
- Domingo-Almenara, X., Guijas, C., Billings, E., Montenegro-Burke, J.R., Uritboonthai, W., Aisporna, A.E., Chen, E., Benton, H.P., and Siuzdak, G. (2019). The METLIN Small Molecule Dataset for Machine Learning-Based Retention Time Prediction. Nat. Commun., 10. · DOI · Paper page
- Seo, 2016, The Impact of Environment and Resonance Effects on the Site of Protonation of Aminobenzoic Acid Derivatives, Phys. Chem. Chem. Phys., 18, 25474, 10.1039/C6CP04941A · DOI
- Liigand, 2017, Think Negative: Finding the Best Electrospray Ionization/MS Mode for Your Analyte, Anal. Chem., 89, 5665, 10.1021/acs.analchem.7b00096 · DOI · Paper page
- Cole, R.B. (2011). Electrospray and MALDI Mass Spectrometry Fundamentals, Instrumentation, Practicalities, and Biological Applications, Wiley. · doi:10.1002/9780470588901
- Kruve, 2017, Predicting ESI/MS Signal Change for Anions in Different Solvents, Anal. Chem., 89, 5079, 10.1021/acs.analchem.7b00595 · doi:10.1021/acs.analchem.7b00595
- Wang, T., Liigand, J., Frandsen, H.L., Smedsgaard, J., and Kruve, A. (2020). Standard Substances Free Quantification Makes LC/ESI/MS Non-Targeted Screening of Pesticides in Cereals Comparable between Labs. Food Chem., 318. · doi:10.1016/j.foodchem.2020.126460
- Lagerwerf, 2000, Exploring the Boundaries of Bioanalytical Quantitative LC–MS–MS, TrAC Trends Anal. Chem., 19, 418, 10.1016/S0165-9936(00)00009-1 · DOI
- Kirwan, 2013, Characterising and Correcting Batch Variation in an Automated Direct Infusion Mass Spectrometry (DIMS) Metabolomics Workflow, Anal. Bioanal. Chem., 405, 5147, 10.1007/s00216-013-6856-7 · DOI · Paper page
- Brunius, C., Shi, L., and Landberg, R. (2016). Large-Scale Untargeted LC-MS Metabolomics Data Correction Using between-Batch Feature Alignment and Cluster-Based within-Batch Signal Intensity Drift Correction. Metabolomics, 12. · DOI · Paper page
- Jiang, 2020, Signal Drift in Liquid Chromatography Tandem Mass Spectrometry and Its Internal Standard Calibration Strategy for Quantitative Analysis, Anal. Chem., 92, 7690, 10.1021/acs.analchem.0c00633 · DOI
- Knolhoff, 2021, A Proposed Quality Control Standard Mixture and Its Uses for Evaluating Nontargeted and Suspect Screening LC/HR-MS Method Performance, Anal. Chem., 93, 1596, 10.1021/acs.analchem.0c04036 · DOI
- Schulze, B., Jeon, Y., Kaserzon, S., Heffernan, A.L., Dewapriya, P., O’Brien, J., Gomez Ramos, M.J., Ghorbani Gorji, S., Mueller, J.F., and Thomas, K.V. (2020). An Assessment of Quality Assurance/Quality Control Efforts in High Resolution Mass Spectrometry Non-Target Workflows for Analysis of Environmental Samples. TrAC Trends Anal. Chem., 133. · DOI
- Alygizakis, 2019, NORMAN Digital Sample Freezing Platform: A European Virtual Platform to Exchange Liquid Chromatography High Resolution-Mass Spectrometry Data and Screen Suspects in “Digitally Frozen” Environmental Samples, TrAC Trends Anal. Chem., 115, 129, 10.1016/j.trac.2019.04.008 · DOI
- Haug, K., Cochrane, K., Nainala, V.C., Williams, M., Chang, J., Jayaseelan, K.V., and O’Donovan, C. (2019). MetaboLights: A Resource Evolving in Response to the Needs of Its Scientific Community. Nucleic Acids Res. · DOI · Paper page
- Sud, 2016, Metabolomics Workbench: An International Repository for Metabolomics Data and Metadata, Metabolite Standards, Protocols, Tutorials and Training, and Analysis Tools, Nucleic Acids Res., 44, D463, 10.1093/nar/gkv1042 · DOI · Paper page
- Kellogg, 2017, Comparison of Metabolomics Approaches for Evaluating the Variability of Complex Botanical Preparations: Green Tea ( Camellia Sinensis ) as a Case Study, J. Nat. Prod., 80, 1457, 10.1021/acs.jnatprod.6b01156 · DOI
- Hernando, 2007, Fast Separation Liquid Chromatography–Tandem Mass Spectrometry for the Confirmation and Quantitative Analysis of Avermectin Residues in Food, J. Chromatogr. A, 1155, 62, 10.1016/j.chroma.2007.02.120 · doi:10.1016/j.chroma.2007.02.120
- Liigand, 2015, Transferability of the Electrospray Ionization Efficiency Scale between Different Instruments, J. Am. Soc. Mass Spectrom., 26, 1923, 10.1007/s13361-015-1219-6 · doi:10.1007/s13361-015-1219-6
Cited by
(2023) · doi:10.1021/acs.estlett.3c00108 · Cited by 67
Novel PFAS-specific monitoring approach for highly impacted surface waters
Ulrich, H., Macherius, A., Kunkel, U., Sengl, M., & Letzel, T. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2023.140893 · Cited by 18
Zhang, H., Wang, X.-Y., Zheng, Y.-H., Hu, J.-R., Li, X.-L., Yin, H.-L., Xiao, R., Zhu, X.-L., Chen, T., & Chen, H. (2025) · Science of The Total Environment · doi:10.1016/j.scitotenv.2025.179748 · Cited by 5
Antić, I., Buljovčić, M., Cochran, R. E., Živančev, J., Llorca, M., Farré, M., Rakić, D., Tautenhahn, R., & Đurišić-Mladenović, N. (2026) · Toxics · doi:10.3390/toxics14010078 · Cited by 3
“These experimentally derived RRFs were then applied to semi-quantify PFAS identified through the SSA workflow by assigning the most appropriate surrogate RRFs according to similarities in retention time and molecular structure between SSA-identified and target compounds [28,29].”
Metadata
- Authors
- Malm, L., Palm, E., Souihi, A., Plassmann, M., Liigand, J., & Kruve, A.
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2021-06-09
- Volume
- 26
- Issue
- 12
- Pages
- 3524
- ISSN
- 1420-3049 (ISSN-L)
- OpenAlex
- W3168956483
- Cited by
- 131
- References
- 5
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Svenska Forskningsrådet Formas (2020-01511)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.