Molecularly Imprinted Polymers (MIPs) in Sensors for Environmental and Biomedical Applications: A Review
Open accessThe DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Abstract
Molecular imprinted polymers are custom made materials with specific recognition sites for a target molecule. Their specificity and the variety of materials and physical shapes in which they can be fabricated make them ideal components for sensing platforms. Despite their excellent properties, MIP-based sensors have rarely left the academic laboratory environment. This work presents a comprehensive review of recent reports in the environmental and biomedical fields, with a focus on electrochemical and optical signaling mechanisms. The discussion aims to identify knowledge gaps that hinder the translation of MIP-based technology from research laboratories to commercialization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460 · cited 7×
“The non-covalent method is the most frequently used, due to ease of both preparation and template removal (by a simple wash in acidic or basic aqueous solution or with alcohol), as well as fast rebinding (with the target molecule) kinetics [61].”
BackgroundInfluentialOccurrence of Antibiotics in the Aquatic Environment
Hirsch, R., Ternes, T., Haberer, K., & Kratz, K.-L. (1999) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00337-4 · Cited by 2,140 · cited 1×
“The selectivity of the sensor was high; however, occurrence of sulfamethoxazole in aquatic ecosystems [205] and wastewaters [206,207] is at much lower concentrations than the detection limit.”
BackgroundDrug assay using antibody mimics made by molecular imprinting
Vlatakis, G., Andersson, L. I., Müller, R., & Mosbach, K. (1993) · Nature · doi:10.1038/361645a0 · Cited by 1,755 · cited 1×
“Prior to polymerization, the target analyte, or template, is combined with a functional monomer to form a precursor structure by covalent [3], semi-covalent [4], or non-covalent [5,6] bonding.”
BackgroundMolecularly Imprinted Polymers
BelBruno, J. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00171 · Cited by 1,654 · cited 6×
“MIP use for purification purposes is the most commercially available application, particularly in analytical chemistry; other uses are still in need of further development [54].”
BackgroundInfluentialGuidelines for data acquisition and data quality evaluation in environmental chemistry
MacDougall, D., Crummett, W. B., & et al. (1980) · Analytical Chemistry · doi:10.1021/ac50064a004 · Cited by 1,621
Electrochemistry of Conducting Polymers—Persistent Models and New Concepts
Heinze, J., Frontana-Uribe, B. A., & Ludwigs, S. (2010) · Chemical Reviews · doi:10.1021/cr900226k · Cited by 1,258 · cited 3×
“Polymer deposition can be achieved by nucleation, growth, and other chemical steps in solid state conditions applying potentiostatic, potentiodynamic, or galvanostatic techniques to start and control these processes [65].”
BackgroundMethodInfluentialAlexander, C., Andersson, H. S., Andersson, L. I., Ansell, R. J., Kirsch, N., Nicholls, I. A., O'Mahony, J., & Whitcombe, M. J. (2006) · Journal of Molecular Recognition · doi:10.1002/jmr.760 · Cited by 1,248 · cited 1×
“Afterwards, the template is eluted, by extraction with a proper solvent or by chemical cleavage, to create empty recognition cavities in the polymer matrix, whose morphology and functionality are complementary to those of the template molecule [7,8].”
MethodMolecularly Imprinted Polymers: Present and Future Prospective
Vasapollo, G., Sole, R. D., Mergola, L., Lazzoi, M. R., Scardino, A., Scorrano, S., & Mele, G. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12095908 · Cited by 1,128 · cited 1×
“The subsequent removal of the template originates microcavities, which are complementary to the shape, size, and spatially orientated functional groups of the template molecule [1,10].”
BackgroundTernes, T. A., Stüber, J., Herrmann, N., McDowell, D., Ried, A., Kampmann, M., & Teiser, B. (2003) · Water Research · doi:10.1016/s0043-1354(02)00570-5 · Cited by 995 · cited 1×
“The selectivity of the sensor was high; however, occurrence of sulfamethoxazole in aquatic ecosystems [205] and wastewaters [206,207] is at much lower concentrations than the detection limit.”
BackgroundEmulsion polymerization mechanisms and kinetics
Chern, C. S. (2006) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2006.02.001 · Cited by 867 · cited 1×
“The type and amount of surfactant controls the particle size, usually in the range of 10–1000 nm [126,127].”
BackgroundSynthesis of substrate‐selective polymers by host‐guest polymerization
Arshady, R., & Mosbach, K. (1981) · Die Makromolekulare Chemie · doi:10.1002/macp.1981.021820240 · Cited by 715 · cited 1×
“Prior to polymerization, the target analyte, or template, is combined with a functional monomer to form a precursor structure by covalent [3], semi-covalent [4], or non-covalent [5,6] bonding.”
BackgroundThe rational development of molecularly imprinted polymer-based sensors for protein detection
Whitcombe, M. J., Chianella, I., Larcombe, L., Piletsky, S. A., Noble, J., Porter, R., & Horgan, A. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00049c · Cited by 711 · cited 1×
“On the other hand, the response of photonic hydrogels can be affected by ionic strength or pH (buffers), possibly limiting their application to protein sensing [302].”
BackgroundWackerlig, J., & Lieberzeit, P. A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.09.094 · Cited by 485 · cited 1×
“Nano and microspheres have both surface and internal porosity, which results in desirable properties such as high surface area, low density, and a high loading capacity, and may find applications in analytical chemistry and biomedical applications: drug delivery, absorption and desorption, high speed chromatography, a…”
BackgroundRecent developments in recognition elements for chemical sensors and biosensors
Justino, C. I. L., Freitas, A. C., Pereira, R., Duarte, A. C., & Rocha‐Santos, T. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.03.006 · Cited by 406 · cited 1×
“Pyrrole [54,68,71] offers good electrical conductivity, biocompatibility, and redox activity [72].”
BackgroundPeer Reviewed: Molecularly Imprinted Polymers: The Next Generation
Haupt, K. (2003) · Analytical Chemistry · doi:10.1021/ac031385h · Cited by 383
Electrochemical sensors based on molecularly imprinted polymers
Blanco-López, M. C., Lobo-Castañón, M. J., Miranda-Ordieres, A. J., & Tuñón-Blanco, P. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00102-5 · Cited by 382
Towards molecularly imprinted polymers selective to peptides and proteins. The epitope approach
Rachkov, A., & Minoura, N. (2001) · Biochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology · doi:10.1016/s0167-4838(00)00226-0 · Cited by 374 · cited 1×
“Rachkov and Minoura [67] employed this concept to covalently bond only a peptide epitope, instead of the whole protein, to a surface, prior to polymerization.”
BackgroundCARO, E., MARCE, R., BORRULL, F., CORMACK, P., & SHERRINGTON, D. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.05.008 · Cited by 338
Li, G. L., Möhwald, H., & Shchukin, D. G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35517a · Cited by 314 · cited 1×
“The polymer grows at a larger extent and precipitates when the chain is long enough to be insoluble [113].”
BackgroundMolecularly-imprinted polymers: useful sorbents for selective extractions
Beltran, A., Borrull, F., Marcé, R. M., & Cormack, P. A. G. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.07.020 · Cited by 307 · cited 3×
“Instead, the ratio of template to functional monomer usually used is 1:1 to 1:2 for the semicovalent technique and 1:4 to 1:8 for the non-covalent, according to the affinity between them and the complexity of the template molecule [2].”
BackgroundInfluentialConducting Polymers in the Design of Biosensors and Biofuel Cells
Ramanavicius, S., & Ramanavicius, A. (2020) · Polymers · doi:10.3390/polym13010049 · Cited by 307 · cited 6×
“Oxidative-chemical polymerization has been widely used due to its simplicity [63].”
BackgroundMethodInfluentialYe, J., Chen, Y., & Liu, Z. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405525 · Cited by 297 · cited 1×
“The SERS methodology involved Ag nanoparticles labeled MIPs with boronate affinity [278].”
MethodMolecular Imprinting Techniques Used for the Preparation of Biosensors
Ertürk, G., & Mattiasson, B. (2017) · Sensors · doi:10.3390/s17020288 · Cited by 292
Jolly, P., Tamboli, V., Harniman, R. L., Estrela, P., Allender, C. J., & Bowen, J. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.043 · Cited by 286
Lowdon, J. W., Diliën, H., Singla, P., Peeters, M., Cleij, T. J., van Grinsven, B., & Eersels, K. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128973 · Cited by 274 · cited 1×
“The approach will be transformative for both medical and environmental fields; however, and in spite of the large number of patents filed worldwide on MIPs, the technology is still mostly restricted to academic laboratories [303].”
BackgroundLong-term stability and reusability of molecularly imprinted polymers
Kupai, J., Razali, M., Buyuktiryaki, S., Kecili, R., & Szekely, G. (2017) · Polymer Chemistry · doi:10.1039/c6py01853j · Cited by 250
Tan, F., Cong, L., Li, X., Zhao, Q., Zhao, H., Quan, X., & Chen, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.146 · Cited by 242
Xue, C., Han, Q., Wang, Y., Wu, J., Wen, T., Wang, R., Hong, J., Zhou, X., & Jiang, H. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.04.022 · Cited by 227
Molecularly Imprinted Polymers
Haupt, K., Linares, A. V., Bompart, M., & Bui, B. T. S. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_307 · Cited by 225 · cited 2×
“The mechanism for the specific recognition of antibodies and antigens, enzymes and substrates, hormones and receptors inspired the development of synthetic materials that mimic nature’s ability to selectively capture chemical species from complex mixtures [1].”
BackgroundMolecularly-imprinted chloramphenicol sensor with laser-induced graphene electrodes
Cardoso, A. R., Marques, A. C., Santos, L., Carvalho, A. F., Costa, F. M., Martins, R., Sales, M. G. F., & Fortunato, E. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.015 · Cited by 205 · cited 1×
“MIP Eriochrome black T (EBT) Graphene SPE C SPE Chloramphenicol Acetonitrile buffer 1 nM–10 mM [197] 0.”
BackgroundHu, Y., Feng, S., Gao, F., Li-Chan, E. C. Y., Grant, E., & Lu, X. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2014.12.051 · Cited by 196
Li, R., Liu, Y., Cheng, L., Yang, C., & Zhang, J. (2014) · Analytical Chemistry · doi:10.1021/ac502616n · Cited by 181 · cited 1×
“01 ppb Aptamer-MIP-GOC3N4 FTO Aptamer Kanamycin Na2SO4 solution 1–230 nM [296] 0.”
BackgroundCrapnell, R. D., Dempsey-Hibbert, N. C., Peeters, M., Tridente, A., & Banks, C. E. (2020) · Talanta Open · doi:10.1016/j.talo.2020.100018 · Cited by 177 · cited 1×
“Other large molecules of interest for which MIP electrochemical biosensors have been reported are the clinical biomarkers for diagnosis of cancer and other cardiovascular diseases [208].”
BackgroundPorous microsphere and its applications
Yuan, W., Cai, Y., Chen, Y., Hong, X., & Liu, Z. (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s41271 · Cited by 173
Suspension Polymerization Processes
Brooks, B. (2010) · Chemical Engineering & Technology · doi:10.1002/ceat.201000210 · Cited by 171
Qarni, H. A., Collier, P. J., O’Keeffe, J. M., & Akunna, J. C. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-6389-7 · Cited by 170 · cited 1×
“The selectivity of the sensor was high; however, occurrence of sulfamethoxazole in aquatic ecosystems [205] and wastewaters [206,207] is at much lower concentrations than the detection limit.”
BackgroundSu, X., Li, X., Li, J., Liu, M., Lei, F., Tan, X., Li, P., & Luo, W. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2014.09.024 · Cited by 169
Tan, X., Hu, Q., Wu, J., Li, X., Li, P., Yu, H., Li, X., & Lei, F. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.05.048 · Cited by 163 · cited 1×
“MIP-RGO-Au NP MAA GCE Carbofuran Vegetables 5 × 10−8–2 × 10−5 M [152] 2 × 10−8 M”
Sanagi, M. M., Salleh, S., Ibrahim, W. A. W., Naim, A. A., Hermawan, D., Miskam, M., Hussain, I., & Aboul-Enein, H. Y. (2013) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2013.09.001 · Cited by 153
Liu, G., Chen, Z., Jiang, X., Feng, D.-Q., Zhao, J., Fan, D., & Wang, W. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.010 · Cited by 152 · cited 1×
“A fluorescence MIP sensor was fabricated combining silica-coated fluorescent carbon dots via sol-gel polymerization to be used in river water samples [239].”
MethodXue, J.-Q., Li, D., Qu, L., & Long, Y. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.03.037 · Cited by 152 · cited 1×
“[279] fabricated surface-imprinted core-shell Au nanoparticles of BPA for detection by SERS in surface water and plastic bottled beverages.”
BackgroundDeng, P., Xu, Z., & Kuang, Y. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2014.02.074 · Cited by 150 · cited 1×
“[170] proposed a voltammetric sensor to detect bisphenol A, another endocrine disruptor of concern.”
BackgroundMolecular imprinted polymers as drug delivery vehicles
Zaidi, S. A. (2014) · Drug Delivery · doi:10.3109/10717544.2014.970297 · Cited by 145
Thủy, T. T. T., Li, J., Feng, H., Cai, J., Yuan, L., Wang, N., & Cai, Q. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.09.048 · Cited by 131
Fiber optic profenofos sensor based on surface plasmon resonance technique and molecular imprinting
Shrivastav, A. M., Usha, S. P., & Gupta, B. D. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.095 · Cited by 123 · cited 1×
“MIP/Ag-POF Optical fiber MAA Profenofos PBS 10−4 μg/L [264] 2.”
BackgroundGu, Y., Yan, X., Li, C., Zheng, B., Li, Y., Liu, W., Zhang, Z., & Yang, M. H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.060 · Cited by 116 · cited 1×
“[173], combining molecular imprinting with mimetic enzymes.”
Liu, Y., Liang, Y., Yang, R., Li, J., & Qu, L. (2018) · Talanta · doi:10.1016/j.talanta.2018.11.052 · Cited by 116 · cited 1×
“2 μM [192] 4 nM MIP-PolydopamineRGO o-phenylenediamine (o-PD) GCE 2,4-dichlorophenol Lake water 2–10; 10–100 nM [193] 0.”
Molecularly imprinted composite materials via iniferter-modified supports
Rückert, B., Hall, A. J., & Sellergren, B. (2002) · Journal of Materials Chemistry · doi:10.1039/b203115a · Cited by 115 · cited 1×
“It is important to limit the free-radical polymerization to the bead surface, for example, with the inclusion of an immobilized chemical compound whose functions are to initiate, transfer, and terminate the polymerization (iniferters) [122,123].”
BackgroundPardeshi, S., Dhodapkar, R., & Kumar, A. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.09.084 · Cited by 113 · cited 1×
“It is possible to control the size and shape of the particles [115] without the aid of surfactants or stabilizers, which avoids potential contamination of the MIPs.”
BackgroundBio-Mimetic Sensors Based on Molecularly Imprinted Membranes
Algieri, C., Drioli, E., Guzzo, L., & Donato, L. (2014) · Sensors · doi:10.3390/s140813863 · Cited by 113 · cited 18×
“The prepolymerization solution was a mixture of the template, MAA, EGDMA, benzoyl peroxide, and acetonitrile that was bulk polymerized.”
BackgroundInfluentialGong, J., Tian, F., Peng, D., Li, A., & Zhang, L. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.008 · Cited by 109
Zhang, W., Xiong, H., Chen, M., Zhang, X., & Wang, S. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.04.035 · Cited by 108
Electrochemical sensing of methyl parathion on magnetic molecularly imprinted polymer
Hassan, A. H. A., Moura, S. L., Ali, F., Moselhy, W. A., Sotomayor, M. D. P. T., & Pividori, M. I. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.06.052 · Cited by 105 · cited 2×
“Magnetic MIP nanoparticles, consisting of a magnetite core, were fabricated for the extraction, cleaning, and pre-concentration of the organophosphorus pesticide, methyl parathion in fish [178].”
BackgroundMethodMolecular imprinting polymers and their composites: a promising material for diverse applications
Zaidi, S. A. (2017) · Biomaterials Science · doi:10.1039/c6bm00765a · Cited by 105 · cited 1×
“These limitations can be partially overcome in the semi-covalent imprinting, in which covalent bonds are formed between the monomer and the template and non-covalent interactions arise between the MIP and the analyte [4,62].”
BackgroundMolecularly imprinted electrochemical sensor for ochratoxin A detection in food samples
Pacheco, J. G., Castro, M., Machado, S., Barroso, M. F., Nouws, H. P. A., & Delerue-Matos, C. M. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.046 · Cited by 103 · cited 1×
“MIP-MWCNT Pyrrole GCE Ochratoxin A Beer, wine 5 × 10−8–10−6 M [154] 4.”
Liu, M., Ding, X. Z., Yang, Q., Wang, Y., Zhao, G., & Yang, N. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.02.031 · Cited by 100 · cited 1×
“MIP-TiO2-MWCNT Core-shell TiO2 Microcystin-LR Tap, pond, and river water 1 pM–3 nM [293] 0.”
Basozabal, I., Guerreiro, A. R., Gómez‐Caballero, A., Goicolea, M. A., & Barrio, R. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.054 · Cited by 98
Chen, H., Zhang, Z., Cai, R., Kong, X.-Q., Chen, X., Liu, Y., & Yao, S. (2013) · The Analyst · doi:10.1039/c3an00146f · Cited by 95
Zheng, X., Lian, Q., Yang, H., & Wang, X. (2016) · Scientific Reports · doi:10.1038/srep21409 · Cited by 94 · cited 1×
“Different polymerization techniques may produce porous microspheres, such as suspension [85–88], precipitation [89–93], emulsion [94–97], grafting [98,99], and swelling [100–102], as well as a combination of two of these methods [103,104].”
BackgroundDuan, H., Li, L., Wang, X., Wang, Y., Li, J., & Luo, C. (2014) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2014.12.051 · Cited by 93
Ng, H. K. M., Leo, C. P., & Abdullah, A. Z. (2017) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2017.07.075 · Cited by 93
Liu, W., Guo, Y., Luo, J., Kou, J., Zheng, H., Li, B., & Zhang, Z. (2015) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2015.01.020 · Cited by 91
Zheng, W., Wu, H., Jiang, Y., Xu, J., Li, X., Zhang, W., & Qiu, F. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.06.004 · Cited by 91
Yang, Y., Yu, J., Yin, J., Shao, B., & Zhang, J. (2014) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf5037933 · Cited by 90
Pan, J., Li, L., Hang, H., Wu, R., Dai, X., Shi, W., & Yan, Y. (2013) · Langmuir · doi:10.1021/la4015288 · Cited by 88
Advances in sensing and biosensing of bisphenols: A review
Dhanjai, D., Sinha, A., Wu, L., Lu, X., Chen, J., & Jain, R. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.09.048 · Cited by 87 · cited 1×
“Pyrrole [54,68,71] offers good electrical conductivity, biocompatibility, and redox activity [72].”
BackgroundLi, Z., Zheng, Y., Liu, Y., Long, S., Du, L., Liang, J., Huang, C. Z., Swihart, M. T., & Tan, K. (2018) · Talanta · doi:10.1016/j.talanta.2018.09.106 · Cited by 84
Xu, L., Fang, G., Pan, M., Wang, X., & Wang, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.072 · Cited by 84
Lu, X., Yang, Y., Zeng, Y., Li, L., & Wu, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.041 · Cited by 80 · cited 1×
“MIP-IL Microspheres 3-(anthracen-9-ylmethyl)-1vinyl-1H-imidazol-3-ium chloride (Fluorescent IL monomer) p-nitroaniline River, lake, and tap water 10 nM–10 M [228] 9 nM”
BackgroundBing-jie, L., Liu, M., Shi, H., Huang, X., & Zhao, G. (2013) · Electroanalysis · doi:10.1002/elan.201200585 · Cited by 76
Jiang, S., Peng, Y., Ning, B., Bai, J., Liu, Y., Zhang, N., & Gao, Z. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.058 · Cited by 75 · cited 1×
“MIP Film MAA Histamine Fish 25–1000 μg/L [266] 25 μg/L”
Anirudhan, T. S., Athira, V. S., & Sekhar, V. C. (2018) · Polymer · doi:10.1016/j.polymer.2018.05.052 · Cited by 75
Ultratrace Detection of Histamine Using a Molecularly-Imprinted Polymer-Based Voltammetric Sensor
Akhoundian, M., Rüter, A., & Shinde, S. (2017) · Sensors · doi:10.3390/s17030645 · Cited by 74 · cited 1×
“MIP MAA CPE Histamine Human serum 10−10–7 × 10−9; 7 × 10−9–4 × 10−7 M [167] 7.”
Dadkhah, S., Ziaei, E., Mehdinia, A., Kayyal, T. B., & Jabbari, A. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1824-5 · Cited by 73
Chang, L., Ding, Y., & Li, X. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.002 · Cited by 68 · cited 1×
“Ag-MIP Core-shell MAA 4-mercaptobenzoic acid Water NI [277] 10−15 M Boronate affinity MIP-Boronate affinity SERS Sandwich assay APTES α-fetoprotein Human serum 0.”
Molecularly imprinted polymer as drug delivery carrier in alginate dressing
Kurczewska, J., Cegłowski, M., Pecyna, P., Ratajczak, M., Gajęcka, M., & Schroeder, G. (2017) · Materials Letters · doi:10.1016/j.matlet.2017.05.008 · Cited by 67
Zhao, Y., Yuan, F., Quan, X., Yu, H., Chen, S., Zhao, H., Liu, Z., & Hilal, N. (2015) · Analytical Methods · doi:10.1039/c4ay03055a · Cited by 66 · cited 1×
“[162] developed a MIP modified boron-doped diamond (BDD) electrode to quantitatively determine the presence of the antibiotic sulfamethoxazole in surface waters.”
BackgroundRecent developments in sensing devices based on polymeric systems
Sanjuán, A. M., Ruiz, J. A. R., García, F. C., & García, J. M. (2018) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2018.10.007 · Cited by 63 · cited 3×
“LOD Photoelectrochemical MIP ITO Pyrrole Bisphenol A River and tap water 2–500 nM [41]1.2 nM MIP-Au NP-ZnO NP Paper Pyrrole Pentacholorophenol Drinking and river water 0.01–100 ng/mL [286]4 pg/mL F graphitic C3N4-MIP FTO 4-vinylpyridine (4-VP) Cr(VI) Tap and river water 0.01–100 ppb [287]0.006 ppb MIP/TiO2 NT Thin fil…”
BackgroundInfluentialYan, K., Yang, Y., & Zhang, J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.12.075 · Cited by 63 · cited 1×
“05 μg/L MIP-Graphitic C3N4 FTO 4-vinylpyridine (4-VP) Bisphenol A Bottled water 5–200 μM [219] 1.”
Yao, T., Gu, X., Li, T., Li, J., Li, J., Zhao, Z. Z., Wang, J., Qin, Y., & She, Y. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.027 · Cited by 61 · cited 1×
“This technique was first developed by Mosbach and collaborators [116] for the synthesis of MIP microspheres [117], nanospheres [118], core-shell particles [119], thin films [120], and nanocomposites [121].”
MethodGuo, Y. J., Kang, L., Chen, S., & Li, X. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp00206k · Cited by 59
Tan, L., Chen, K., Huang, C. X., Peng, R., Luo, X., Yang, R., Cheng, Y., & Tang, Y. (2015) · Microchimica Acta · doi:10.1007/s00604-015-1642-1 · Cited by 57 · cited 1×
“[223] based on fluorescence and Ye et al.”
MethodFoguel, M. V., Ton, X., Zanoni, M. V. B., Sotomayor, M. D. P. T., Haupt, K., & Bui, B. T. S. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.05.007 · Cited by 56 · cited 2×
“MIP Particles 2-acrylamido-2-methyl-1propanesulfonic acid (AMPSA) Basic red 9 Ultrapure water NI [217] NI”
BackgroundPreparation of a magnetic molecularly imprinted polymer for selective recognition of rhodamine B
Liu, X., Yu, D., Yu, Y., & Ji, S. (2014) · Applied Surface Science · doi:10.1016/j.apsusc.2014.08.122 · Cited by 56
Yang, Y., Fang, G., Wang, X., Zhang, F., Liu, J., Zheng, W., & Wang, S. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.01.043 · Cited by 56 · cited 1×
“Electrochemiluminescent graphene quantum dots were proposed for the detection of the herbicide 2-methyl-4-chlorophenoxyacetic acid [254].”
BackgroundBiomimetic Nanoparticles Based Surface Plasmon Resonance Biosensors for Histamine Detection in Foods
Rahtuvanoğlu, A., Akgönüllü, S., Karacan, S., & Denizli, A. (2020) · ChemistrySelect · doi:10.1002/slct.202000440 · Cited by 56
Asman, S. B., Mohamad, S., & Sarih, N. M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023656 · Cited by 53
Nezhadali, A., & Mojarrab, M. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.03.010 · Cited by 51
Li, X., Wang, X., Tian, F., Zhang, L., & Gong, J. (2018) · Talanta · doi:10.1016/j.talanta.2018.01.005 · Cited by 49
Liu, B., Xiao, B., Cui, L., & Wang, M. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.05.080 · Cited by 49
Kuwata, T., Uchida, A., Takano, E., Kitayama, Y., & Takeuchi, T. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03134 · Cited by 44
Jiang, Q., Zhang, D., Cao, Y., & Gan, N. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.02.020 · Cited by 44
Zhang, B., Lü, L., Huang, F., & Lin, Z. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.051 · Cited by 43
Guo, Z., Chen, L., Lv, H., Yu, Z., & Zhao, B. (2013) · Analytical Methods · doi:10.1039/c3ay40866c · Cited by 43 · cited 1×
“MIP-Magnetic NP Core-shell MAA Ciprofloxacin Fetal bovine serum 10−7–10−4 M [280] 10−7 M”
Rosy, R., Chasta, H., & Goyal, R. N. (2014) · Talanta · doi:10.1016/j.talanta.2014.02.038 · Cited by 42 · cited 2×
“MIP o-aminophenol GCE Norepinephrine Human plasma and urine, pharmaceuticals 5 × 10−8–10−5 M [139] 4.”
BackgroundDeng, P., Xu, Z., Li, J., & Kuang, Y. (2013) · Microchimica Acta · doi:10.1007/s00604-013-1001-z · Cited by 42 · cited 1×
“MIP-Chitosan Chitosan ABPE Bisphenol A Polycarbonate baby feeding and water bottle, PVC bottle, PVC food package in water solution 80 nM–10 μM [185] 60 nM”
MethodTan, F., Zhao, Q., Teng, F., Sun, D., Gao, J., Quan, X., & Chen, J. (2014) · Materials Letters · doi:10.1016/j.matlet.2014.05.039 · Cited by 41 · cited 1×
“This technique was first developed by Mosbach and collaborators [116] for the synthesis of MIP microspheres [117], nanospheres [118], core-shell particles [119], thin films [120], and nanocomposites [121].”
MethodCapacitive sensing of N-formylamphetamine based on immobilized molecular imprinted polymers
Graniczkowska, K. B., Pütz, M., Hauser, F. M., Saeger, S. D., & Beloglazova, N. V. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.083 · Cited by 40 · cited 3×
“LOD Capacitance Aptamer-MIP Dopamine Au Prostate specific antigen TBST buffer 0.1–100 ng/mL [133]1 pg/mL Sol-gel-MIP N,N-methylene bisacrylamide (MBAA) C Methidathion Wastewater 40–200 µg/L [134]5.14 µg/L Silica NP-Au NP-MIP-Chitosan MAA GCE Fumosin B1 Maize, milk 0.001–100 ng/mL [135]0.35 pg/mL MIP MAA Au Nformylamph…”
BackgroundMethodInfluentialNabavi, S. A., Vladisavljević, G. T., Eguagie, E. M., Li, B., Georgiadou, S., & Manovic, V. M. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.07.054 · Cited by 37 · cited 1×
“Common stabilizers include surfactants [107] and ionic liquids [108].”
BackgroundChen, Z., Tang, C., Zeng, Y., Liu, H., Yin, Z., & Li, L. (2014) · Analytical Letters · doi:10.1080/00032719.2013.862624 · Cited by 37
Enantioselective analysis of D- and l- Serine on a layer-by-layer imprinted electrochemical sensor
Jaiswal, S., Singh, R., Singh, K., Fatma, S., & Prasad, B. B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.090 · Cited by 36 · cited 1×
“MIP-RGO Acrylamide PGE D-, L-serine Blood serum, cerebrospinal fluid, water, pharmaceutics Depending on the sample [188] 0.”
BackgroundRen, X., & Li, X. (2020) · Analytical Methods · doi:10.1039/d0ay00575d · Cited by 33 · cited 1×
“MIP-Ag Core-shell Acrylamide Glibenclamide Water 1 ng/mL–100 μg/mL [282] 1 ng/mL”
Thermal preparation of lysozyme-imprinted microspheres by using ionic liquid as a stabilizer
Qian, L., Hu, X.-L., Guan, P., Gao, B., Wang, D., Wang, C., Li, J., Du, C., & Song, W. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8133-9 · Cited by 32 · cited 1×
“Common stabilizers include surfactants [107] and ionic liquids [108].”
BackgroundQiu, H., Fan, L., Li, X., Li, L., Sun, M. H., & Luo, C. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.11.010 · Cited by 31
Imprinted microspheres doped with carbon nanotubes as novel electroresponsive drug‐delivery systems
Puoci, F., Hampel, S., Parisi, O. I., Hassan, A., Cirillo, G., & Picci, N. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39212 · Cited by 30
Xiong, Y., Ye, Z., Xu, J. M., Liu, Y., & Zhang, H. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7664-4 · Cited by 28 · cited 1×
“MIP/POF Capillary tube MAA Bisphenol A Mineral water bottle in ethanol and water solutions 3 × 10−9–5 × 10−6 g/mL [226] 1.”
Chen, S., Li, X., Han, S., Liu, J., & Zhao, Y. (2015) · RSC Advances · doi:10.1039/c5ra19528d · Cited by 26 · cited 1×
“Ag-MIP Core-shell nanoplates Methacrylamide Rhodamine B Ultrapure water NI [275] 10−12 M”
BackgroundSaksena, K., Shrivastava, A., & Kant, R. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.04.043 · Cited by 25 · cited 1×
“MIP Aniline PGE L-ascorbic acid Bovine serum, water 1–100 μM [184] 1 μM”
Feyzioğlu-Demir, E., Özçalışkan, E., Karakaş, H., Uygun, M., Uygun, D. A., Akgöl, S., & Deni̇zli̇, A. (2018) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2018.1534423 · Cited by 24
de León-Martínez, L. D., Rodríguez‐Aguilar, M., Ocampo‐Pérez, R., Gutiérrez-Hernández, J. M., Díaz-Barriga, F., Batres-Esquivel, L. E., & Flores‐Ramírez, R. (2018) · Bulletin of Environmental Contamination and Toxicology · doi:10.1007/s00128-017-2249-5 · Cited by 24
Liu, M., Li, Y., Han, J., & Dong, X. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400034 · Cited by 19 · cited 1×
“This technique was first developed by Mosbach and collaborators [116] for the synthesis of MIP microspheres [117], nanospheres [118], core-shell particles [119], thin films [120], and nanocomposites [121].”
MethodRizk, M. S., Toubar, S. S., Sayour, H. E. M., Mohamed, D., & Tony, R. M. (2014) · European Journal of Chemistry · doi:10.5155/eurjchem.5.1.18-23.876 · Cited by 16 · cited 2×
“MIP MAA PVC Imidocarb dipropionate Bovine liver and kidney 10−5–10−2 M [146] 2 × 10−6 M”
MethodLi, H., Wang, Y., Li, Y., Qiao, Y., Liu, L., Wang, Q.-W., & Che, G. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117784 · Cited by 13 · cited 1×
“SiO2/rGO/Au-MIP NP Methacrylic acid, acrylamide 2,6-dichlorophenol Water 1–100 nM [283] 0.”
BackgroundYılmaz, F. (2013) · InTech eBooks · doi:10.5772/2749 · Cited by 12
Electrochemical methods for biomedical investigations
Shumyantseva, V. V., Bulko, T. V., Suprun, E. V., Kuzikov, A. V., Agafonova, L. E., & Archakov, A. I. (2015) · Biomeditsinskaya Khimiya · doi:10.18097/pbmc20156102188 · Cited by 10
Water treatment by molecularly imprinted polymer nanoparticles
Schreiber, T., Weber, A., Niedergall, K., Riegler, J., Bryniok, D., Hirth, T., & Tovar, G. E. M. (2009) · MRS Proceedings · doi:10.1557/proc-1169-q04-07 · Cited by 8
Electrochemical methods in biomedical studies
Shumyantseva, V. V., Bulko, T. V., Suprun, E. V., Kuzikov, A. V., Agafonova, L. E., & Archakov, A. I. (2015) · Biochemistry (Moscow) Supplement Series B Biomedical Chemistry · doi:10.1134/s1990750815030087 · Cited by 5 · cited 1×
“Otherwise, N-isopropylacrylamide (NIPAAm) [58,60,74], and o-phenylenediamine (o-PD) [75,76] may also be cited for the non-covalent approach.”
Background
Cited by
Natural and Synthetic Polymers for Biomedical and Environmental Applications
Satchanska, G., Davidova, S., & Petrov, P. D. (2024) · Polymers · doi:10.3390/polym16081159 · Cited by 585
“In addition to water and wastewater treatment, MIPs have also been fabricated for solid-phase extraction, chromatographic separation, catalysis, drug delivery, the study of the structure and function of proteins, environmental and biomedical sensing, and membrane-based separations [42].”
Background
Metadata
- Authors
- Kadhem, A. J., Gentile, G. J., & Fidalgo de Cortalezzi, M. M.
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2021-10-15
- Volume
- 26
- Issue
- 20
- Pages
- 6233
- ISSN
- 1420-3049 (ISSN-L)
- OpenAlex
- W3205581746
- Cited by
- 178
- References
- 117
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.