Development of a Biodegradable Subcutaneous Implant for Prolonged Drug Delivery Using 3D Printing
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Implantable drug delivery devices offer many advantages over other routes of drug delivery. Most significantly, the delivery of lower doses of drug, thus, potentially reducing side-effects and improving patient compliance. Three dimensional (3D) printing is a flexible technique, which has been subject to increasing interest in the past few years, especially in the area of medical devices. The present work focussed on the use of 3D printing as a tool to manufacture implantable drug delivery devices to deliver a range of model compounds (methylene blue, ibuprofen sodium and ibuprofen acid) in two in vitro models. Five implant designs were produced, and the release rate varied, depending on the implant design and the drug properties. Additionally, a rate controlling membrane was produced, which further prolonged the release from the produced implants, signalling the potential use of these devices for chronic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and comparison of dissolution profiles
Costa, P., & Sousa Lobo, J. M. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00095-1 · Cited by 5,509 · cited 2×
“In order for two dissolution profiles to be considered similar, the F1 value should be lower than 15 × (0–15) and F2 value should be more than 50 × (50–100) [30,31].”
BackgroundBiomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206 · cited 1×
“They are designed to degrade naturally to products that can be excreted easily by the body [17].”
BackgroundLanger, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Inherited susceptibility to uterine leiomyomas and renal cell cancer
Launonen, V., Vierimaa, O., Kiuru, M., Isola, J., Roth, S., Pukkala, E., Sistonen, P., Herva, R., & Aaltonen, L. A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051633798 · Cited by 669 · cited 1×
“A good alternative to obtain implants with prolonged drug release profiles is to coat them with a membrane capable of sustaining drug release [55].”
BackgroundTherapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358
In vitro and in vivo demonstration of risperidone implants in mice
Rabin, C., Liang, Y., Ehrlichman, R. S., Budhian, A., Metzger, K. L., Majewski-Tiedeken, C., Winey, K. I., & Siegel, S. J. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2007.08.003 · Cited by 64 · cited 1×
“In addition, these devices allow personalised medicine, increased patient compliance [6] and prolonged delivery of treatment over weeks, months or years [7] in a device which may be removed if adverse effects require early termination of treatment [8,9].”
Background
Cited by
Arif, Z. U., Khalid, M. Y., Noroozi, R., Sadeghianmaryan, A., Jalalvand, M., & Hossain, M. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.07.140 · Cited by 395
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
Self-citationHernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Emerging 3D printing technologies for drug delivery devices: Current status and future perspective
Wang, J., Zhang, Y., Aghda, N. H., Pillai, A. R., Thakkar, R., Nokhodchi, A., & Maniruzzaman, M. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.04.019 · Cited by 247
Harnessing artificial intelligence for the next generation of 3D printed medicines
Elbadawi, M., McCoubrey, L. E., Gavins, F. K. H., Ong, J. J., Goyanes, A., Gaisford, S., & Basit, A. W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.015 · Cited by 172
Metadata
- Authors
- Stewart, S., Domínguez-Robles, J., McIlorum, V., Mancuso, E., Lamprou, D., Donnelly, R., & Larrañeta, E.
- Venue
- Pharmaceutics
- Publisher
- MDPI AG
- Published
- 2020-01-28
- Volume
- 12
- Issue
- 2
- Pages
- 105
- ISSN
- 1999-4923 (ISSN-L)
- OpenAlex
- W3003372248
- Cited by
- 176
- References
- 6
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.