CoChat

Peripheral Wavefront Sensor with Fixation Target Made by Optical Simulation for Measuring Human Eye Regardless of Spectacle

Open access
Oh, Su-Keun, Kim, Jung-Min, Yoon, Geun-Young, Yoo, Young-Sik, Kim, Dae Yu · 2024 · Photonics

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Abstract

This study proposes a custom-built aberrometer that measures peripheral defocus to evaluate myopia progression in the human eye. This advanced device can measure visual fields in both horizontal (up to 40°) and vertical (up to 30°) orientations. It incorporates a novel fixation target that is meticulously designed using an optical simulation software. Notably, each angular point of this novel fixation target differs considerably from the conventional fixation target. To mitigate the effects of the optical variations introduced by spectacles and the subject’s vision, we incorporated a position-variable lens positioned in front of the eye. This lens compensates for these variations, enhancing the precision of the measurements. To evaluate the performance of the proposed aberrometer, we conducted experiments under three distinct conditions: first, with the naked eye; second, while wearing spectacles; and third, while wearing a multifocal lens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/photonics11040332

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Cont.
Figure 1 Cont.CC-BY · From the PDF
Figure 1 ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam spliĴer; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ). Figure 1. ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam splitter; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ). Figure 1. ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam spliĴer; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ).
Figure 1 ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam spliĴer; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ). Figure 1. ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam splitter; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ). Figure 1. ( a ) Schematic of the new aberrometer; L1, L2, and L3: achromatic doublet lens; M1, M2: Mirror, DM: Dichroic mirror; BS: Beam spliĴer; PH: Pinhole, FT: Fixation target. ( b ) Photograph of the new aberrometer. ( c ) Compensating process that moves the position-variable lens (L2) forward and backward to compensate for unwanted alterations generated by the spectacle and subjects. ( d ) An enlarged picture of the process in ( c ).CC-BY · From the PDF
Figure 2 ( a ) A schematic of the whole new aberrometer. ( b ) Optimal state of L2. ( c ) Personalizing process of L2. Figure 2. ( a ) A schematic of the whole new aberrometer. ( b ) Optimal state of L2. ( c ) Personalizing process of L2.
Figure 2 ( a ) A schematic of the whole new aberrometer. ( b ) Optimal state of L2. ( c ) Personalizing process of L2. Figure 2. ( a ) A schematic of the whole new aberrometer. ( b ) Optimal state of L2. ( c ) Personalizing process of L2.CC-BY · From the PDF
Figure 3 Cont.
Figure 3 Cont.CC-BY · From the PDF
Figure 3 ( a ) Peripheral vision layout considering optical properties of the human eye. ( b ) To visualize the differences, all points of the two fixation targets displayed in ( c , d ) are displayed in a 2D chart. The blue and red spots represent the results of ( c , d ), respectively. The interval between the red and blue 20° points is 43.1 mm when the fixation target is 200 mm from the cornea of the model eye. ( c ) OpticStudio ® 3D layout was used to create a new fixation target using an eye model. ( d ) The OpticStudio ® 3D layout of the conventional fixation target. ( e ) Enlarged picture of light entering the eye. ( f ) Enlarged picture of the light path when the optical properties of the eye are not considered. 2.4. Data Acquisition Figure 3. ( a ) Peripheral vision layout considering optical properties of the human eye. ( b ) To visualize the differences, all points of the two fixation targets displayed in ( c , d ) are displayed in a 2D chart. The blue and red spots represent the results of ( c , d ), respectively. The interval between the red and blue 20 ◦ points is 43.1 mm when the fixation target is 200 mm from the cornea of the model eye. ( c ) OpticStudio ® 3D layout was used to create a new fixation target using an eye model. ( d ) The OpticStudio ® 3D layout of the conventional fixation target. ( e ) Enlarged picture of light entering the eye. ( f ) Enlarged picture of the light path when the optical properties of the eye are not considered.
Figure 3 ( a ) Peripheral vision layout considering optical properties of the human eye. ( b ) To visualize the differences, all points of the two fixation targets displayed in ( c , d ) are displayed in a 2D chart. The blue and red spots represent the results of ( c , d ), respectively. The interval between the red and blue 20° points is 43.1 mm when the fixation target is 200 mm from the cornea of the model eye. ( c ) OpticStudio ® 3D layout was used to create a new fixation target using an eye model. ( d ) The OpticStudio ® 3D layout of the conventional fixation target. ( e ) Enlarged picture of light entering the eye. ( f ) Enlarged picture of the light path when the optical properties of the eye are not considered. 2.4. Data Acquisition Figure 3. ( a ) Peripheral vision layout considering optical properties of the human eye. ( b ) To visualize the differences, all points of the two fixation targets displayed in ( c , d ) are displayed in a 2D chart. The blue and red spots represent the results of ( c , d ), respectively. The interval between the red and blue 20 ◦ points is 43.1 mm when the fixation target is 200 mm from the cornea of the model eye. ( c ) OpticStudio ® 3D layout was used to create a new fixation target using an eye model. ( d ) The OpticStudio ® 3D layout of the conventional fixation target. ( e ) Enlarged picture of light entering the eye. ( f ) Enlarged picture of the light path when the optical properties of the eye are not considered.CC-BY · From the PDF
Figure 4 Subjects #1, #2, and #3 (S1, S2, and S3) are represented by the red-doĴed, blue-dashed, and solid-green lines, respectively. ( a ) Nasal to temporal relative spherical error graphs and ( b ) up to down relative spherical error graphs for no glasses (naked eye: C1). ( c ) Nasal to temporal relative spherical error graphs and ( d ) up to down relative spherical error graphs for glasses (wearing glasses: C2). ( e ) Nasal to temporal relative spherical error graphs and ( f ) up to down relative spherical error graphs for MFSCL (wearing MFSCL: C3). Figure 4. Subjects #1, #2, and #3 (S1, S2, and S3) are represented by the red-dotted, blue-dashed, and solid-green lines, respectively. ( a ) Nasal to temporal relative spherical error graphs and ( b ) up to down relative spherical error graphs for no glasses (naked eye: C1). ( c ) Nasal to temporal relative spherical error graphs and ( d ) up to down relative spherical error graphs for glasses (wearing glasses: C2). ( e ) Nasal to temporal relative spherical error graphs and ( f ) up to down relative spherical error graphs for MFSCL (wearing MFSCL: C3).
Figure 4 Subjects #1, #2, and #3 (S1, S2, and S3) are represented by the red-doĴed, blue-dashed, and solid-green lines, respectively. ( a ) Nasal to temporal relative spherical error graphs and ( b ) up to down relative spherical error graphs for no glasses (naked eye: C1). ( c ) Nasal to temporal relative spherical error graphs and ( d ) up to down relative spherical error graphs for glasses (wearing glasses: C2). ( e ) Nasal to temporal relative spherical error graphs and ( f ) up to down relative spherical error graphs for MFSCL (wearing MFSCL: C3). Figure 4. Subjects #1, #2, and #3 (S1, S2, and S3) are represented by the red-dotted, blue-dashed, and solid-green lines, respectively. ( a ) Nasal to temporal relative spherical error graphs and ( b ) up to down relative spherical error graphs for no glasses (naked eye: C1). ( c ) Nasal to temporal relative spherical error graphs and ( d ) up to down relative spherical error graphs for glasses (wearing glasses: C2). ( e ) Nasal to temporal relative spherical error graphs and ( f ) up to down relative spherical error graphs for MFSCL (wearing MFSCL: C3).CC-BY · From the PDF
Figure 5 The red line in the middle of the graph represents the average of the differences between the naked eye and wearing spectacle results acquired from S1, S2, and S3. The upper red-doĴed line represents the upper 95% confidential interval, while the lower red-doĴed line represents the lower 95% confidential interval. The R-value of 0.219 means that no significant differences exist between the two experiments. Figure 5. The red line in the middle of the graph represents the average of the differences between the naked eye and wearing spectacle results acquired from S1, S2, and S3. The upper red-dotted line represents the upper 95% confidential interval, while the lower red-dotted line represents the lower 95% confidential interval. The R-value of 0.219 means that no significant differences exist between the two experiments.
Figure 5 The red line in the middle of the graph represents the average of the differences between the naked eye and wearing spectacle results acquired from S1, S2, and S3. The upper red-doĴed line represents the upper 95% confidential interval, while the lower red-doĴed line represents the lower 95% confidential interval. The R-value of 0.219 means that no significant differences exist between the two experiments. Figure 5. The red line in the middle of the graph represents the average of the differences between the naked eye and wearing spectacle results acquired from S1, S2, and S3. The upper red-dotted line represents the upper 95% confidential interval, while the lower red-dotted line represents the lower 95% confidential interval. The R-value of 0.219 means that no significant differences exist between the two experiments.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1

Metadata

Authors
Oh, S.-K., Kim, J.-M., Yoon, G.-Y., Yoo, Y.-S., & Kim, D. Y.
Affiliations
  • Inha University (KR)
  • Department of Electrical and Computer Engineering, Inha University, Incheon 22212, Republic of Korea
  • College of Optometry, University of Houston, Houston, TX 77004, USA
  • The Catholic University of Korea Uijeongbu St. Mary's Hospital (KR)
Corresponding author
  • Yoo, Young-Sik
  • Kim, Dae Yu
Venue
Photonics
Publisher
MDPI AG
Published
2024-04-02
Volume
11
Issue
4
Pages
332
ISSN
2304-6732 (ISSN-L)
OpenAlex
W4393558562
Cited by
1
References
51
Citations by year
2026: 1
FWCI
0.31
Type
journal article
Language
en
Open access
Locations
  • Photonics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Research Foundation of Korea (2021R1I1A1A01056094, 2018R1A6A1A03025523, 2023R1A2C1004330, KMDF_PR_ 20200901_0026)
  • Korean government (2021R1I1A1A01056094, 2018R1A6A1A03025523, 2023R1A2C1004330, KMDF_PR_ 20200901_0026)
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Adaptive optics and wavefront sensing
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Optical measurement and interference techniques
Keywords
wavefront sensor, fixation target, peripheral defocus, myopia progression, optical simulation, multifocal lens, visual field testing, aberrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.