The DOI matches its Crossref record; 71 of the 72 references it cites were found in a registry or an index.
High-Throughput Raman Spectroscopy Combined with Innovate Data Analysis Workflow to Enhance Biopharmaceutical Process Development
Open accessAbstract
Raman spectroscopy has the potential to revolutionise many aspects of biopharmaceutical process development. The widespread adoption of this promising technology has been hindered by the high cost associated with individual probes and the challenge of measuring low sample volumes. To address these issues, this paper investigates the potential of an emerging new high-throughput (HT) Raman spectroscopy microscope combined with a novel data analysis workflow to replace off-line analytics for upstream and downstream operations. On the upstream front, the case study involved the at-line monitoring of an HT micro-bioreactor system cultivating two mammalian cell cultures expressing two different therapeutic proteins. The spectra generated were analysed using a partial least squares (PLS) model. This enabled the successful prediction of the glucose, lactate, antibody, and viable cell density concentrations directly from the Raman spectra without reliance on multiple off-line analytical devices and using only a single low-volume sample (50–300 μL). However, upon the subsequent investigation of these models, only the glucose and lactate models appeared to be robust based upon their model coefficients containing the expected Raman vibrational signatures. On the downstream front, the HT Raman device was incorporated into the development of a cation exchange chromatography step for an Fc-fusion protein to compare different elution conditions. PLS models were derived from the spectra and were found to predict accurately monomer purity and concentration. The low molecular weight (LMW) and high molecular weight (HMW) species concentrations were found to be too low to be predicted accurately by the Raman device. However, the method enabled the classification of samples based on protein concentration and monomer purity, allowing a prioritisation and reduction in samples analysed using A280 UV absorbance and high-performance liquid chromatography (HPLC). The flexibility and highly configurable nature of this HT Raman spectroscopy microscope makes it an ideal tool for bioprocess research and development, and is a cost-effective solution based on its ability to support a large range of unit operations in both upstream and downstream process operations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These include a Raman microscope coupled to an automated plate reader to support early-stage scale-down conditions [70], an academic study that used in-line viscosity and off-line Raman measurements as input into a Monad model of CHO cell metabolism, [71] and an off-line time-gated Raman/SERS microscopy approach coupled to a custom microwell plate for E. coli fermentations [20].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [70]
In the citing paper
“The study did establish the feasibility of integrating Raman microscopy with standard scale-down bioreactors and autosamplers for at-line measurements of small volumes using standard polypropylene and custom stainless steel 96 well plates.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [70]
In the citing paper
“In an attempt to reduce operating costs, Goldrick et al. explored the potential of a high‐throughput Raman spectroscopy microscope in monitoring different elution conditions and monomer purity in a cation exchange chromatography (CEX) step of a Fc‐fusion protein in downstream processing.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
In the citing paper
“Combined with chemometric modelling, this method was able to classify samples based on protein concentration and monomer purity.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
In the citing paper
“However, this method was not able to accurately detect low and high molecular weight species.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Reference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 2×
“895 δ (C-H), δ (C-OH) [66] 898 [62] 910 δ (C-H) [63] 913 [62] 914 [67] 990 [65]”
Multi‐way principal components‐and PLS‐analysis
Wold, S., Geladi, P., Esbensen, K., & Öhman, J. (1987) · Journal of Chemometrics · doi:10.1002/cem.1180010107 · Cited by 748
UPLC™: An Introduction and Review
Swartz, M. E. (2005) · Journal of Liquid Chromatography & Related Technologies · doi:10.1081/jlc-200053046 · Cited by 571
Hong, P., Koza, S., & Bouvier, E. S. P. (2012) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2012.743724 · Cited by 557
FTIR and laser-Raman spectra of oligosaccharides in water: characterization of the glycosidic bond
Kačuráková, M., & Mathlouthi, M. (1996) · Carbohydrate Research · doi:10.1016/0008-6215(95)00412-2 · Cited by 455 · cited 4×
“1372 glucose (w (CH2)) [68] 1373 [62] 1374 [65]”
InfluentialTheory and practice of size exclusion chromatography for the analysis of protein aggregates
Fekete, S., Beck, A., Veuthey, J.-L., & Guillarme, D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.011 · Cited by 324 · cited 1×
“As standard SE-HPLC has long run times (commonly 20 min per sample), efforts have been made to increase the speed of analysis and implement SE-HPLC-based methods on-line [23].”
MethodAbu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322 · cited 1×
“However, the majority of Raman spectroscopy monitoring operations focus on Chinese hamster ovary (CHO) mammalian cell lines, and have demonstrated the ability of this technology to predict the previously prioritised CPPs of glucose, lactate, VCD, and product concentration [15,17,18].”
BackgroundInfrared and raman spectroscopy of carbohydrates
Vasko, P. D., Blackwell, J., & Koenig, J. L. (1971) · Carbohydrate Research · doi:10.1016/s0008-6215(00)86160-1 · Cited by 178 · cited 6×
“1128 1120 δ (COH) [63] 1121 [65] 1122 [67] 1124 ν (CO) [68] 1125 ν (C-C) [66] 1130 [62]”
InfluentialCraven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171 · cited 1×
“, who applied a nonlinear model predictive controller to maintain the glucose concentration of a mammalian cell culture at a fixed set-point [19].”
BackgroundVibrational spectra of lactic acid and lactates
Cassanas, G., Morssli, M., Fabrégue, E., & Bardet, L. (1991) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250220709 · Cited by 167 · cited 6×
“Antibody **** 538 540 lactate (w (CO2-)) [70,71]”
Influential
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“Off-line data or Raman data were used to calculate VCD and viable cell diameter.”
BackgroundMethodInfluentialHow machine learning can accelerate electrocatalysis discovery and optimization
Steinmann, S. N., Wang, Q., & Seh, Z. W. (2022) · Materials Horizons · doi:10.1039/d2mh01279k · Cited by 141
Khuat, T. T., Bassett, R., Otte, E. A., Grevis-James, A., & Gabryś, B. (2024) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2024.108585 · Cited by 108
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
“However, the classification of samples based on concentration and purity allowed the prioritization and reduction in samples analysed by the regular HPLC and UV setup [76].”
Continuous integrated manufacturing for biopharmaceuticals: A new paradigm or an empty promise?
Rathore, A. S., Thakur, G., & Kateja, N. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28235 · Cited by 41
“…monitoring in bioreactor B. N. Berry et al. (2016); Matthews et al. (2016, 2018); Rafferty et al. (2020) Chromatography pooling (protein variants) Goldrick et al. (2020); Yilmaz et al. (2020) Chromatography loading (Protein A capture) Feidl et al. (2019); Walch et al. (2019) Fluorescence…”
Armstrong, A., Horry, K., Cui, T., Hulley, M. E., Turner, R. C., Farid, S. S., Goldrick, S., & Bracewell, D. G. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461914 · Cited by 40
Self-citationA decade in review: use of data analytics within the biopharmaceutical sector
Banner, M., Alosert, H., Spencer, C., Cheeks, M., Farid, S. S., Thomas, M. R., & Goldrick, S. (2021) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2021.100758 · Cited by 48
Self-citationWang, J., Chen, J., Studts, J., & Wang, G. (2023) · mAbs · doi:10.1080/19420862.2023.2220149 · Cited by 37
Rolinger, L., Rüdt, M., & Hubbuch, J. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27894 · Cited by 33
“This background effect is sometimes attributed to the fluorescence of cell culture components (Goldrick et al., 2020; Whelan et al., 2012).”
BackgroundRathore, A. S., Nikita, S., & Jesubalan, N. G. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100263 · Cited by 51
Autonomous high-throughput computations in catalysis
Steinmann, S. N., Hermawan, A., Jassar, M. B., & Seh, Z. W. (2022) · Chem Catalysis · doi:10.1016/j.checat.2022.02.009 · Cited by 51
Nitika, N., Keerthiveena, B., Thakur, G., & Rathore, A. S. (2024) · Pharmaceutical Research · doi:10.1007/s11095-024-03663-9 · Cited by 26
“Applications in the downstream process, however, have been limited for detection of breakthrough in Protein A chromatography [40, 41] and determination of concentration and purity of monomer with respect to aggregate of an Fc fusion protein [42].”
Schiemer, R., Rüdt, M., & Hubbuch, J. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1228846 · Cited by 23
Harnessing Raman spectroscopy for cell therapy bioprocessing
Costa, M. H., Carrondo, I., Isidro, I. A., & Serra, M. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108472 · Cited by 21
Dietrich, A., Schiemer, R., Kurmann, J., Zhang, S., & Hubbuch, J. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1399938 · Cited by 21
Advances and opportunities in process analytical technologies for viral vector manufacturing
Sripada, S. A., Hosseini, M., Ramesh, S., Wang, J., Ritola, K., Menegatti, S., & Daniele, M. A.-A. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108391 · Cited by 19
Artificial intelligence guided Raman spectroscopy in biomedicine: Applications and prospects
Liu, Y., Chen, S., Xiong, X., Wen, Z., Zhao, L., Xu, B., Guo, Q., Xia, J., & Pei, J. (2025) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2025.101271 · Cited by 28
Living Sample Viability Measurement Methods from Traditional Assays to Nanomotion
Al-madani, H., Du, H., Yao, J., Peng, H., Yao, C., Jiang, B., Wu, A., & Yang, F. (2022) · Biosensors · doi:10.3390/bios12070453 · Cited by 19
“RS’s challenges include the weak Raman signal [71] and light scattering [72], which reduce the method’s sensitivity.”
BackgroundWallocha, T., & Popp, O. (2021) · Processes · doi:10.3390/pr9112073 · Cited by 18
Guardalini, L. G. O., Cavalcante, P. E. D. S., Leme, J., de Mello, R. G., Bernardino, T. C., Jared, S. G. S., Antoniazzi, M. M., Astray, R. M., Tonso, A., Núñez, E. G. F., et al. (2022) · Vaccines · doi:10.3390/vaccines11010039 · Cited by 12
“The used desirability function method can solve the simultaneous optimization of several response variables using univariate techniques [19,20].”
MethodDambruin, N. A., Pronk, J. T., & Klijn, M. E. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-05949-2 · Cited by 16
“Moreover, available analytical models for biomass determination in monocultures often do not address the origin of observed peaks (e.g., [79, 80]), and it is therefore unclear if spectral peaks correspond with intracellular compounds.”
Berg, C., Ihling, N., Finger, M., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2022) · Bioengineering · doi:10.3390/bioengineering9090438 · Cited by 10
“Amongst others, spectroscopic measurement methods based on Raman [19,20], impedance [21–23] or single-wavelength fluorescence [24,25] have successfully been transferred from lab-scale reactors to microscale cultivation systems.”
MethodComparing machine learning methods on Raman spectra from eight different spectrometers
Lange, C., Borisyak, M., Kögler, M., Born, S., Ziehe, A., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125861 · Cited by 11
Wang, J., Chen, J., Studts, J., & Wang, G. (2024) · Biotechnology and Bioengineering · doi:10.1002/bit.28679 · Cited by 7
Wang, J., Chen, J., Juergen, H., Studts, J., & Wang, G. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28514 · Cited by 8
“Currently, Raman spectrometry can feasibly measure therapeutic protein concentration (Goldrick et al., 2020), product aggregation (Zhou et al., 2015), fragmentation, charge variants, and oxidation (Wei et al., 2021).”
A Setup for Automatic Raman Measurements in High‐Throughput Experimentation
Lange, C., Seidel, S., Altmann, M., Stors, D., Kemmer, A., Cai, L., Born, S., Neubauer, P. B., & Bournazou, M. N. C. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70006 · Cited by 11
“Additionally, measuring Raman spectra in high optical density bacterial fer-mentations requires flexible modifications for sample preparation to enhance signal intensity (Rodriguez et al. 2023; Goldrick et al. 2020).”
Deep learning for Raman spectroscopy: Benchmarking models for upstream bioprocess monitoring
Lange, C., Altmann, M., Stors, D., Seidel, S., Moynahan, K., Cai, L., Born, S., Neubauer, P., & Bournazou, M. N. C. (2025) · Measurement · doi:10.1016/j.measurement.2025.118884 · Cited by 10
Carvalho, M. F., da Cruz, A. L. B., Haringa, C., Ottens, M., & Klijn, M. E. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70139 · Cited by 6
“The use of high‐throughput (HT) Raman spectroscopy was analyzed by Goldrick et al. (2020) as an option to circumvent the high cost associated with individual probes and the difficulty of measuring low sample volumes.”
Halfway to Automated Feeding of Chinese Hamster Ovary Cells
Tomažič, S., & Škrjanc, I. (2023) · Sensors · doi:10.3390/s23146618 · Cited by 4
“These methods must be able to manage large multidimensional data sets while exploring the totality of spectral information [12].”
BackgroundMeasurement Technologies for Upstream and Downstream Bioprocessing
Mandenius, C. (2021) · Processes · doi:10.3390/pr9010143 · Cited by 5
“An example of this is high-throughput Raman spectroscopy microscopy using a spectral data analysis workflow to replace off-line analytics [11].”
MethodYeoh, J. X., Choong, Y. S., & Lim, T. S. (2025) · Protein Expression and Purification · doi:10.1016/j.pep.2025.106857 · Cited by 3
Martinez, E. W., Tfayli, A. M., Chaminade, P., & Tfaili, S. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.127836 · Cited by 5
Application of Raman Spectroscopy to Dynamic Binding Capacity Analysis
Beattie, J. W., Rowland‐Jones, R. C., Farys, M., Bettany, H., Hilton, D., Kazarian, S. G., & Byrne, B. (2023) · Applied Spectroscopy · doi:10.1177/00037028231210293 · Cited by 2
Sebastian, M., Goldrick, S., Cheeks, M., Turner, R. C., & Farid, S. S. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28571 · Cited by 2
Self-citationAthalye, S. M., Maruthamuthu, M. K., Esmaili, E., Boodaghidizaji, M., Sarathy, N., Mayorga, C., Raffaele, J., Selvamani, V., Smith, J. P., Matos, T., et al. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126761 · Cited by 3
Development of a Raman Model for Continuous Monitoring of Detergent Viral Inactivation
Denny, K., Znidarsic, M., Hamedi, H., Stanley, B., & Khattak, S. F. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70087 · Cited by 2
“In downstream processing (DSP), Raman has been used to measure protein concentration and PQ attributes in multiple unit operations (Feidl et al. 2019; Goldrick et al. 2020; McAvan et al. 2020; McAvan et al. 2020).”
Umprecht, A., Uth, N., Kim, H., Oliver Spadiut, A., & Yang, Y. (2026) · Biotechnology Progress · doi:10.1002/btpr.88506 · Cited by 2
“16,26,27 28 – 30 In this set-up, samples are delivered from each vessel to an integrated flow cell via the built-in liquid handler.”
Self-citationGuo, J., Xi, L., & Gao, H. (2026) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2026.04.014 · Cited by 1
Rüdt, M., Bussien, A., Cortada‐Garcia, J., Morschett, H., Holm, H., Mazzucchelli, C., & Flicker, K. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.70033 · Cited by 2
“This pattern has been discussed in more detail elsewhere (Goldrick et al. 2020; Whelan et al. 2012).”
2027 A local buckling models for box columns with constant strain triangular elements
桑原, 進., & 澤井, 祥. (1994) · 日本建築学会近畿支部研究報告集. 構造系
Deep Learning for Raman Spectroscopy: Benchmarking Models for Upstream Bioprocess MonitoringPreprint
Lange, C., Altmann, M., Stors, D., Seidel, S., Moynahan, K., Cai, L., Born, S., Neubauer, P. B., & Bournazou, M. N. C. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5239248
Ghanes, S., Degeiter, M., Epifano, E., Vaubois, T., Fossard, F., Mérot, J., Horezan, N., Perrut, M., & Monceau, D. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5823336
Simultaneous Denoising and Baseline Correction of Microplate Raman Spectra Using a Dual-Branch U-NetPreprint
Atia, K., Hunter, R., & Anis, H. (2026) · bioRxiv · doi:10.64898/2026.04.07.716998
Chen, J., Wang, J., Schuck, E., Wang, G., Studts, J., & Franzreb, M. (2026) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-026-06612-0
“These bottlenecks can be overcome by developing an automated high-throughput setup [1] for Raman data acquisition.”
Banner, M., Ray, D., Ahanger, I., Zurlo, F., Hitchcock, N., Rajesh, M., Kozakowska-McDonnell, K., Cheeks, M., Turner, R., Welsh, J. P., et al. (2026) · Biotechnology Progress · doi:10.1002/btpr.88531 · Cited by 1
Self-citationMachine Learning‐Enhanced Generic Raman Model for Commercial‐Scale Cell Culture Process Monitoring
Shen, Y., Wan, Y., Wu, S., Yan, X., Chen, H., Chen, Z., Wang, H., & Qu, H. (2026) · Biotechnology Journal · doi:10.1002/biot.70309
“Their locations are therefore consistent with glucose-related spectral variation [52–54].”
Luo, Y., Pareek, S., Zhang, C., Sarnese, K., Ritz, D. B., & Talwar, S. (2026) · Biotechnology and Bioengineering · doi:10.1002/bit.70400
Simultaneous Denoising and Baseline Correction of Microplate Raman Spectra Using a Dual-Branch U-Net
Atia, K. S. R., Hunter, R., & Anis, H. (2026) · ACS Omega · doi:10.1021/acsomega.6c04490 · Cited by 1
Metadata
- Authors
- Goldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., & Farid, S. S.
- Affiliations
- AstraZeneca (United Kingdom) (GB)
- University College London (GB)
- Corresponding author
- Goldrick, Stephen
- Umprecht, Alexandra
- ORCID
- Venue
- Processes
- Publisher
- MDPI AG
- Published
- 2020-09-17
- Volume
- 8
- Issue
- 9
- Pages
- 1179
- ISSN
- 2227-9717 (ISSN-L)
- OpenAlex
- W3086663814
- Cited by
- 48
- References
- 72
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 7 · 2023: 5 · 2022: 7 · 2021: 6
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Processes (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/I033270/1)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Viral Infectious Diseases and Gene Expression in Insects
- Keywords
- biopharmaceutical process development, partial least squares model, mammalian cell culture, antibody production, cation exchange chromatography, Fc fusion protein, monomer purity, low-volume sample analysis, microbioreactors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.