High-Throughput Raman Spectroscopy Combined with Innovate Data Analysis Workflow to Enhance Biopharmaceutical Process Development
Open accessAbstract
Raman spectroscopy has the potential to revolutionise many aspects of biopharmaceutical process development. The widespread adoption of this promising technology has been hindered by the high cost associated with individual probes and the challenge of measuring low sample volumes. To address these issues, this paper investigates the potential of an emerging new high-throughput (HT) Raman spectroscopy microscope combined with a novel data analysis workflow to replace off-line analytics for upstream and downstream operations. On the upstream front, the case study involved the at-line monitoring of an HT micro-bioreactor system cultivating two mammalian cell cultures expressing two different therapeutic proteins. The spectra generated were analysed using a partial least squares (PLS) model. This enabled the successful prediction of the glucose, lactate, antibody, and viable cell density concentrations directly from the Raman spectra without reliance on multiple off-line analytical devices and using only a single low-volume sample (50–300 μL). However, upon the subsequent investigation of these models, only the glucose and lactate models appeared to be robust based upon their model coefficients containing the expected Raman vibrational signatures. On the downstream front, the HT Raman device was incorporated into the development of a cation exchange chromatography step for an Fc-fusion protein to compare different elution conditions. PLS models were derived from the spectra and were found to predict accurately monomer purity and concentration. The low molecular weight (LMW) and high molecular weight (HMW) species concentrations were found to be too low to be predicted accurately by the Raman device. However, the method enabled the classification of samples based on protein concentration and monomer purity, allowing a prioritisation and reduction in samples analysed using A280 UV absorbance and high-performance liquid chromatography (HPLC). The flexibility and highly configurable nature of this HT Raman spectroscopy microscope makes it an ideal tool for bioprocess research and development, and is a cost-effective solution based on its ability to support a large range of unit operations in both upstream and downstream process operations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These include a Raman microscope coupled to an automated plate reader to support early-stage scale-down conditions [70], an academic study that used in-line viscosity and off-line Raman measurements as input into a Monad model of CHO cell metabolism, [71] and an off-line time-gated Raman/SERS microscopy approach coupled to a custom microwell plate for E. coli fermentations [20].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [70]
In the citing paper
“The study did establish the feasibility of integrating Raman microscopy with standard scale-down bioreactors and autosamplers for at-line measurements of small volumes using standard polypropylene and custom stainless steel 96 well plates.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [70]
In the citing paper
“In an attempt to reduce operating costs, Goldrick et al. explored the potential of a high‐throughput Raman spectroscopy microscope in monitoring different elution conditions and monomer purity in a cation exchange chromatography (CEX) step of a Fc‐fusion protein in downstream processing.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
In the citing paper
“Combined with chemometric modelling, this method was able to classify samples based on protein concentration and monomer purity.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
In the citing paper
“However, this method was not able to accurately detect low and high molecular weight species.”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [76]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Reference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 2×
“895 δ (C-H), δ (C-OH) [66] 898 [62] 910 δ (C-H) [63] 913 [62] 914 [67] 990 [65]”
Multi‐way principal components‐and PLS‐analysis
Wold, S., Geladi, P., Esbensen, K., & Öhman, J. (1987) · Journal of Chemometrics · doi:10.1002/cem.1180010107 · Cited by 748
UPLC™: An Introduction and Review
Swartz, M. E. (2005) · Journal of Liquid Chromatography & Related Technologies · doi:10.1081/jlc-200053046 · Cited by 571
Hong, P., Koza, S., & Bouvier, E. S. P. (2012) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2012.743724 · Cited by 557
FTIR and laser-Raman spectra of oligosaccharides in water: characterization of the glycosidic bond
Kačuráková, M., & Mathlouthi, M. (1996) · Carbohydrate Research · doi:10.1016/0008-6215(95)00412-2 · Cited by 455 · cited 4×
“1372 glucose (w (CH2)) [68] 1373 [62] 1374 [65]”
InfluentialTheory and practice of size exclusion chromatography for the analysis of protein aggregates
Fekete, S., Beck, A., Veuthey, J.-L., & Guillarme, D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.011 · Cited by 324 · cited 1×
“As standard SE-HPLC has long run times (commonly 20 min per sample), efforts have been made to increase the speed of analysis and implement SE-HPLC-based methods on-line [23].”
MethodAbu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322 · cited 1×
“However, the majority of Raman spectroscopy monitoring operations focus on Chinese hamster ovary (CHO) mammalian cell lines, and have demonstrated the ability of this technology to predict the previously prioritised CPPs of glucose, lactate, VCD, and product concentration [15,17,18].”
BackgroundInfrared and raman spectroscopy of carbohydrates
Vasko, P. D., Blackwell, J., & Koenig, J. L. (1971) · Carbohydrate Research · doi:10.1016/s0008-6215(00)86160-1 · Cited by 178 · cited 6×
“1128 1120 δ (COH) [63] 1121 [65] 1122 [67] 1124 ν (CO) [68] 1125 ν (C-C) [66] 1130 [62]”
InfluentialCraven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171 · cited 1×
“, who applied a nonlinear model predictive controller to maintain the glucose concentration of a mammalian cell culture at a fixed set-point [19].”
BackgroundVibrational spectra of lactic acid and lactates
Cassanas, G., Morssli, M., Fabrégue, E., & Bardet, L. (1991) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250220709 · Cited by 167 · cited 6×
“Antibody **** 538 540 lactate (w (CO2-)) [70,71]”
InfluentialLaser-raman spectra of d-glucose and sucrose in aqueous solution
Mathlouthi, M., & Luu, D. V. (1980) · Carbohydrate Research · doi:10.1016/s0008-6215(00)85652-9 · Cited by 165 · cited 7×
“1128 1120 δ (COH) [63] 1121 [65] 1122 [67] 1124 ν (CO) [68] 1125 ν (C-C) [66] 1130 [62]”
InfluentialApplications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160 · cited 1×
“Different types of Raman Spectroscopy, including Resonance Raman Spectroscopy, Raman Optical Activity, and surface-enhanced Raman spectroscopy (SERS), as well as their applications, are extensively described in a review by Buckley and Ryder [13].”
Haberger, M., Leiß, M., Heidenreich, A.-K., Pester, O., Hafenmair, G., Hook, M., Bonnington, L. S., Wegele, H., Haindl, M., Reusch, D., et al. (2015) · mAbs · doi:10.1080/19420862.2015.1122150 · Cited by 148 · cited 1×
“Decreasing the time needed for sample analysis to less than 5 min was made possible by utilising ultra-high-performance liquid chromatography (UHPLC) with sub-2μm particles [24,25], and these approaches were further developed by coupling to mass spectroscopy [26].”
MethodBerry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142 · cited 1×
“These VCD predictions are also comparable to on-line Raman spectroscopy systems monitoring mammalian cell culture systems reporting predictions in the range of 1–5 × 106 cells per mL−1 [18,61].”
ResultAdvances in size-exclusion separations of proteins and polymers by UHPLC
Bouvier, E. S. P., & Koza, S. M. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.08.002 · Cited by 132 · cited 1×
“Decreasing the time needed for sample analysis to less than 5 min was made possible by utilising ultra-high-performance liquid chromatography (UHPLC) with sub-2μm particles [24,25], and these approaches were further developed by coupling to mass spectroscopy [26].”
MethodRaman spectra of fructose and glucose in the amorphous and crystalline states
Söderholm, S., Roos, Y. H., Meinander, N., & Hotokka, M. (1999) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199911)30:11<1009::aid-jrs436>3.0.co;2-# · Cited by 131 · cited 2×
“Glucose * 442 446 450 443 [62] 450 δ (C-C-O) [63] 451 [64]”
BackgroundRolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126 · cited 1×
“[33], each of these spectroscopic techniques has its own set of advantages and applications.”
BackgroundMatthews, T. E., Berry, B. N., Smelko, J. P., Moretto, J., Moore, B., & Wiltberger, K. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.26018 · Cited by 122 · cited 3×
“Within USP, the biopharmaceutical industry has focused on Raman spectroscopy as one of the leading PAT technologies to monitor fermentation systems cultivating different expression systems, such as bacterial [14], fungal [12], and mammalian cell culture systems, including NS0 and HEK293 cell lines [15,16].”
BackgroundZhou, C., Qi, W., Lewis, E. N., & Carpenter, J. F. (2014) · Analytical Biochemistry · doi:10.1016/j.ab.2014.11.016 · Cited by 112 · cited 7×
“Zhou et al. monitored the thermally induced aggregation of intravenous IgG (IVIG) at high concentrations (51 mg/mL), describing the various spectral features present upon aggregation, in particular shift in the tyrosine peak at 830 and 850 cm−1 and the tryptophan peak at 1550 cm−1 for the IVIG, using Raman spectroscop…”
BackgroundMethodInfluentialHigh-throughput cocrystal slurry screening by use of in situ Raman microscopy and multi-well plate
Kojima, T., Tsutsumi, S., Yamamoto, K., Ikeda, Y., & Moriwaki, T. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.07.055 · Cited by 107 · cited 2×
“The HT Raman devices described in the literature include commercial devices such as the RamanRxn1TM High Throughput Screener (HTS) (Kaiser Optical Systems, Ann Arbor, MI, USA) [54], the InVia confocal microscope (Renishaw, Wotton-under-Edge, UK) presented in this work, the Lab Ram HR Evolution confocal microscope (Hor…”
MethodPecul, M., Rizzo, A., & Leszczyński, J. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp021030m · Cited by 105 · cited 6×
“Antibody **** 538 540 lactate (w (CO2-)) [70,71]”
InfluentialHigh-Throughput Screening Raman Spectroscopy Platform for Label-Free Cellomics
Schie, I. W., Rüger, J., Mondol, A. S., Ramoji, A., Neugebauer, U., Krafft, C., & Popp, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04127 · Cited by 101 · cited 1×
“The HT Raman devices described in the literature include commercial devices such as the RamanRxn1TM High Throughput Screener (HTS) (Kaiser Optical Systems, Ann Arbor, MI, USA) [54], the InVia confocal microscope (Renishaw, Wotton-under-Edge, UK) presented in this work, the Lab Ram HR Evolution confocal microscope (Hor…”
MethodProtein Interactions Investigated by the Raman Spectroscopy for Biosensor Applications
Kengne-Momo, R. P., Daniel, P., Lagarde, F., Jeyachandran, Y. L., PILARD, J. ‐., Durand, M.-J., & Thouand, G. (2012) · International Journal of Spectroscopy · doi:10.1155/2012/462901 · Cited by 99
Rüdt, M., Briskot, T., & Hubbuch, J. J. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.11.010 · Cited by 85 · cited 1×
“[32], and more recently in Rolinger et al.”
BackgroundIn-line and real-time prediction of recombinant antibody titer by in situ Raman spectroscopy
André, S., Cristau, L. S., Gaillard, S., Devos, O., Calvosa, É., & Duponchel, L. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.08.050 · Cited by 82 · cited 1×
“using an immersion probe [40], and further expanded by Feidl et al.”
MethodBrunner, M., Fricke, J., Kroll, P., & Herwig, C. (2017) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1693-7 · Cited by 79 · cited 1×
“Therapeutic proteins are highly complex and fragile molecules, and any upstream process deviations can lead to changes in the physiochemical, biological, and immunogenic properties of the molecule [2].”
BackgroundUV Raman Spectral Intensities of E. Coli and Other Bacteria Excited at 228.9, 244.0, and 248.2 nm
Wu, Q., Hamilton, T., Nelson, W. H., Elliott, S., Sperry, J. F., & Wu, M. T. (2001) · Analytical Chemistry · doi:10.1021/ac001268b · Cited by 78 · cited 1×
“Within USP, the biopharmaceutical industry has focused on Raman spectroscopy as one of the leading PAT technologies to monitor fermentation systems cultivating different expression systems, such as bacterial [14], fungal [12], and mammalian cell culture systems, including NS0 and HEK293 cell lines [15,16].”
BackgroundDevelopment of generic raman models for a GS‐KO TM CHO platform process
Webster, T. A., Hadley, B. C., Hilliard, W., Jaques, C., & Mason, C. (2018) · Biotechnology Progress · doi:10.1002/btpr.2633 · Cited by 77 · cited 2×
“These VCD predictions are also comparable to on-line Raman spectroscopy systems monitoring mammalian cell culture systems reporting predictions in the range of 1–5 × 106 cells per mL−1 [18,61].”
BackgroundResultPerformance of line-scan Raman microscopy for high-throughput chemical imaging of cell population
Qi, J., & Shih, W. (2014) · Applied Optics · doi:10.1364/ao.53.002881 · Cited by 76 · cited 1×
“The HT Raman devices described in the literature include commercial devices such as the RamanRxn1TM High Throughput Screener (HTS) (Kaiser Optical Systems, Ann Arbor, MI, USA) [54], the InVia confocal microscope (Renishaw, Wotton-under-Edge, UK) presented in this work, the Lab Ram HR Evolution confocal microscope (Hor…”
MethodMedipally, D., Maguire, A., Bryant, J., Armstrong, J., Dunne, M., Finn, M. A., Lyng, F. M., & Meade, A. D. (2016) · The Analyst · doi:10.1039/c6an02100j · Cited by 69 · cited 2×
“The HT Raman devices described in the literature include commercial devices such as the RamanRxn1TM High Throughput Screener (HTS) (Kaiser Optical Systems, Ann Arbor, MI, USA) [54], the InVia confocal microscope (Renishaw, Wotton-under-Edge, UK) presented in this work, the Lab Ram HR Evolution confocal microscope (Hor…”
MethodSandor, M., Rüdinger, F., Bienert, R., Grimm, C., Solle, D., & Scheper, T. H. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.08.002 · Cited by 68 · cited 1×
“compared the ability of NIR and MIR for mammalian cell monitoring and concluded that MIR has a higher accuracy for individual analyte concentrations, such as glucose and lactate, but recommended NIR as a better tool for the on-line monitoring of mammalian cell systems based on its ability to measure cell densities thr…”
BackgroundPatel, B. A., Pinto, N. D. S., Gospodarek, A. M., Kilgore, B. R., Goswami, K., Napoli, W. N., Desai, J., Heo, J. H., Panzera, D., Pollard, D. J., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02228 · Cited by 68 · cited 1×
“describes the use of on-line UHPLC for the detection of charge variants in continuous processes, which can be adapted for aggregate analysis [29].”
BackgroundBrestrich, N., Rüdt, M., Büchler, D., & Hubbuch, J. J. (2017) · Chemical Engineering Science · doi:10.1016/j.ces.2017.10.030 · Cited by 68 · cited 1×
“UV spectroscopy has been also shown to monitor mAb aggregate and monomer concentrations [35], although during the investigated runs the monomer and aggregate peaks showed a good separation, which might not always be the case and could decrease the otherwise high sensitivity of predictions.”
BackgroundChalla, S., & Potumarthi, R. (2012) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-012-9950-y · Cited by 66 · cited 1×
“PAT ultimately aims to integrate aspects of chemical, physical, microbiological, mathematical, and risk analyses to ensure robust biopharmaceutical operation [5].”
BackgroundHakemeyer, C., Strauss, U. T., Werz, S., José, G. E., Folque, F., & de Menezes, J. C. (2011) · Talanta · doi:10.1016/j.talanta.2011.12.042 · Cited by 65
Thakur, G., Hebbi, V., & Rathore, A. S. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27236 · Cited by 64
Monitoring the Glycosylation Status of Proteins Using Raman Spectroscopy
Brewster, V. L., Ashton, L., & Goodacre, R. (2011) · Analytical Chemistry · doi:10.1021/ac2012009 · Cited by 61
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59 · cited 1×
“through the development of a Raman flow cell [41,42].”
BackgroundReal‐time monitoring and control of the load phase of a protein A capture step
Rüdt, M., Brestrich, N., Rolinger, L., & Hubbuch, J. J. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.26078 · Cited by 58
Real-time fouling monitoring with Raman spectroscopy
Virtanen, T., Рейникайнен, С.-П., Kögler, M., Mänttäri, M., Viitala, T., & Kallioinen, M. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2016.12.005 · Cited by 58 · cited 2×
“Virtanen et al. describes using Raman spectroscopy in membrane fouling monitoring, where an immersion probe was placed into a cross-flow filtration unit, and fouling over time by vanillin, a model organic foulant, was monitored using PCA [53].”
MethodRaman spectroscopic study of the structure of antibodies
Painter, P. C., & Koenig, J. L. (1975) · Biopolymers · doi:10.1002/bip.1975.360140303 · Cited by 55 · cited 1×
“Protein aggregate 831 863 901 830; 850 Tyr [45] 878 Tyr [73]”
Ude, C., Schmidt‐Hager, J., Findeis, M., John, G. T., Scheper, T. H., & Beutel, S. (2014) · Sensors · doi:10.3390/s140917390 · Cited by 53
Yilmaz, D., Mehdizadeh, H., Navarro, D., Shehzad, A., O'Connor, M., & McCormick, P. (2020) · Biotechnology Progress · doi:10.1002/btpr.2947 · Cited by 51 · cited 1×
“Determining the titre is especially relevant for continuous perfusion processes, as it allows the dynamic loading of subsequent capture steps, as demonstrated in [43].”
BackgroundUse of HPLC as an Enabler of Process Analytical Technology in Process Chromatography
Tiwari, A., Kateja, N., Chanana, S., & Rathore, A. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00897 · Cited by 49
Chmielowski, R., Mathiasson, L., Blom, H., Go, D., Ehring, H., Khan, H., Li, H., Cutler, C., Lacki, K. M., Tugçu, N., et al. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.10.030 · Cited by 47 · cited 1×
“However, the titre determination from harvest can arguably be achieved by the use of delta UV spectroscopy comparing the A280 absorbance of the feed and eluate [44], which might be easier to implement as it does not require MVDA modelling.”
MethodLaser Raman spectra of mono-, oligo- and polysaccharides in solution
Barrett, T. W. (1981) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/0584-8539(81)80168-7 · Cited by 46 · cited 4×
“895 δ (C-H), δ (C-OH) [66] 898 [62] 910 δ (C-H) [63] 913 [62] 914 [67] 990 [65]”
InfluentialFeidl, F., Garbellini, S., Luna, M. F., Vogg, S., Souquet, J., Broly, H., Morbidelli, M., & Butté, A. (2019) · Processes · doi:10.3390/pr7100683 · Cited by 46 · cited 1×
“through the development of a Raman flow cell [41,42].”
BackgroundRolinger, L., Rüdt, M., Diehm, J., Chow-Hubbertz, J., Heitmann, M., Schleper, S., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02318-8 · Cited by 46 · cited 1×
“The same device was recently applied to the on-line monitoring of ultrafiltration/diafiltration (UF/DF) as part of a multi-sensor PAT capable of monitoring concentration in addition to the apparent molecular weight using dynamic light scattering (DLS) to monitor changes in aggregation during the process [36].”
MethodDetection of Protein Glycosylation Using Tip-Enhanced Raman Scattering
Cowcher, D. P., Deckert‐Gaudig, T., Brewster, V. L., Ashton, L., Deckert, V., & Goodacre, R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03535 · Cited by 43
Universal capacitance model for real-time biomass in cell culture
Konakovsky, V., Yagtu, A., Clemens, C., Müller, M., Berger, M., Schlatter, S., & Herwig, C. (2015) · Sensors · doi:10.3390/s150922128 · Cited by 41 · cited 1×
“demonstrated the ability of capacitance probes to accurately predict VCD for mammalian cell cultures using a robust partial least squares (PLS) model that could be transferred between clones and across scales [6].”
At-line mid infrared spectroscopy for monitoring downstream processing unit operations
Capito, F., Skudas, R., Kolmar, H., & Hunzinger, C. (2015) · Process Biochemistry · doi:10.1016/j.procbio.2015.03.005 · Cited by 41 · cited 1×
“used MIR to monitor product concentration, aggregate, and HCP content, although this was developed as an at-line method, as the samples were processed (dried) prior to measurements [38], limiting the use of the tool for on-line monitoring.”
MethodHost cell protein quantification by fourier transform mid infrared spectroscopy (FT‐MIR)
Capito, F., Skudas, R., Kolmar, H., & Stanislawski, B. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24611 · Cited by 40 · cited 1×
“with limited sensitivity [52], which does not allow for widespread use.”
BackgroundRapid Identification of Biotherapeutics with Label-Free Raman Spectroscopy
Paidi, S. K., Siddhanta, S., Strouse, R., McGivney, J. B., Larkin, C. J., & Barman, I. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04794 · Cited by 40
Zhang, C., Springall, J. S., Wang, X., & Barman, I. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.07.007 · Cited by 40
Prediction of the Quantity and Purity of an Antibody Capture Process in Real Time
Walch, N., Scharl, T., Felföldi, E., Sauer, D. G., Melcher, M., Leisch, F., Dürauer, A., & Jungbauer, A. (2019) · Biotechnology Journal · doi:10.1002/biot.201800521 · Cited by 37 · cited 1×
“This has resulted in accurate predictions for titre and monomer purity, but less so for HCPs, DNA, and % aggregate, especially when the sample matrix was changed [39].”
BackgroundCalvet, A., Li, B., & Ryder, A. G. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.08.002 · Cited by 36 · cited 1×
“to identify the composition changes of tryptophan and tyrosine in a complex media applicable to industrial mammalian cell cultures [11].”
BackgroundRowland‐Jones, R. C., & Jaques, C. M. (2018) · Biotechnology Progress · doi:10.1002/btpr.2740 · Cited by 36 · cited 7×
“Alternatively, HT scale-down models such as ambrTM 15 (Sartorius Stedim, Göttingen, Germany) with at-line (Rowland-Jones and Jaques 2019) or integrated Raman measurement can be utilised for model building, although the latter has only been introduced recently.”
BackgroundMethodResultInfluentialde la Cuesta, R. G., Goodacre, R., & Ashton, L. (2014) · Analytical Chemistry · doi:10.1021/ac5038329 · Cited by 34 · cited 2×
“By studying multiple different mAbs, differences were observed in the aggregation mechanism and associated spectral features [46], which might potentially make it difficult to develop models that could be utilised across multiple antibody formats.”
BackgroundMatthews, T. E., Smelko, J. P., Berry, B., Romero‐Torres, S., Hill, D., Kshirsagar, R., & Wiltberger, K. (2018) · Biotechnology Progress · doi:10.1002/btpr.2711 · Cited by 34 · cited 1×
“Within USP, the biopharmaceutical industry has focused on Raman spectroscopy as one of the leading PAT technologies to monitor fermentation systems cultivating different expression systems, such as bacterial [14], fungal [12], and mammalian cell culture systems, including NS0 and HEK293 cell lines [15,16].”
BackgroundRhiel, M. H., Amrhein, M., Marison, I. W., & von Stockar, U. (2002) · Analytical Chemistry · doi:10.1021/ac020165l · Cited by 33 · cited 2×
“[69] during the analysis of the main metabolites of a CHO cell culture using a MIR probe.”
BackgroundDetection of glycosylation and iron-binding protein modifications using Raman spectroscopy
Ashton, L., Brewster, V. L., Correa, E. S., & Goodacre, R. (2017) · The Analyst · doi:10.1039/c6an02516a · Cited by 32
Raman spectroscopy as a method to replace off‐line pH during mammalian cell culture processes
Rafferty, C., O'Mahony, J., Burgoyne, B., Rea, R., Balss, K. M., & Latshaw, D. C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27197 · Cited by 31
Fluorescence‐based soft sensor for at situ monitoring of chinese hamster ovary cell cultures
Ohadi, K., Aghamohseni, H., Legge, R. L., & Budman, H. M. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25222 · Cited by 29 · cited 1×
“demonstrated the ability of this technique to predict numerous variables, including the product concentration and glucose, and also to distinguish between living and dead cells, therefore making it an attractive tool for the in situ monitoring of mammalian cell cultures [10].”
BackgroundProtein Conformation from Raman and Resonance Raman Spectra
CAREY, P. R. (1982) · Elsevier eBooks · doi:10.1016/b978-0-12-159650-7.50007-9 · Cited by 29
Ultrafast Separation and Analysis of Monoclonal Antibody Aggregates Using Membrane Chromatography
Madadkar, P., Umatheva, U., Hale, G., Durocher, Y., & Ghosh, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00580 · Cited by 28
Versatile automated continuous flow system (VersAFlo) for bioanalysis and bioprocess control
Kumar, M., Mazlomi, M. A., Hedström, M., & Mattìasson, B. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.049 · Cited by 24 · cited 1×
“Efforts have been made to develop immunological methods capable of on-line measurements utilising a flow cell, although the analysis time of above 30 min per sample would not suit the current downstream requirements [31].”
BackgroundRaman spectroscopy of complex defined media: biopharmaceutical applications
Singh, G., Goh, S., Canzoneri, M., & Ram, R. J. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4686 · Cited by 24 · cited 9×
“1128 1120 δ (COH) [63] 1121 [65] 1122 [67] 1124 ν (CO) [68] 1125 ν (C-C) [66] 1130 [62]”
BackgroundMethodInfluentialLi, M., Ebel, B., Blanchard, F., Paris, C., Guédon, E., & Marc, A. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26914 · Cited by 20
Goldrick, S., Lovett, D., Montague, G. A., & Lennox, B. (2018) · Bioengineering · doi:10.3390/bioengineering5040079 · Cited by 19 · cited 5×
“Corrupting fluorescence still remains a major problem for Raman spectroscopy, particularly during upstrea processing operations, where broad fluorescence background sig als have been sh wn to mask out important Rama peaks and thu preve t the extraction of us ful correlat ons [12].”
BackgroundMethodSelf-citationProcess Analytical Technology: Strategies for Biopharmaceuticals
Rathore, A. S., & Kapoor, G. (2013) · Wiley eBooks · doi:10.1002/9780470054581.eib652 · Cited by 8
Heo, J. H., Mou, X., Wang, F., Troisi, J., Sandifer, C. W., Kirby, S., Driscoll, D., Mercorelli, S., & Pollard, D. J. (2014) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.14.12 · Cited by 8 · cited 1×
“The processing time can be decreased by moving from a traditional ELISA to an automated ELISA using liquid-handling systems and automated microfluidic systems [30]; these still do not allow real-time analysis, as the time needed to run these assays is in the order of hours.”
Method
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“Off-line data or Raman data were used to calculate VCD and viable cell diameter.”
BackgroundMethodInfluentialHow machine learning can accelerate electrocatalysis discovery and optimization
Steinmann, S. N., Wang, Q., & Seh, Z. W. (2022) · Materials Horizons · doi:10.1039/d2mh01279k · Cited by 141
Khuat, T. T., Bassett, R., Otte, E. A., Grevis-James, A., & Gabryś, B. (2024) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2024.108585 · Cited by 108
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
“However, the classification of samples based on concentration and purity allowed the prioritization and reduction in samples analysed by the regular HPLC and UV setup [76].”
Continuous integrated manufacturing for biopharmaceuticals: A new paradigm or an empty promise?
Rathore, A. S., Thakur, G., & Kateja, N. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28235 · Cited by 41
“…monitoring in bioreactor B. N. Berry et al. (2016); Matthews et al. (2016, 2018); Rafferty et al. (2020) Chromatography pooling (protein variants) Goldrick et al. (2020); Yilmaz et al. (2020) Chromatography loading (Protein A capture) Feidl et al. (2019); Walch et al. (2019) Fluorescence…”
Metadata
- Authors
- Goldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., & Farid, S. S.
- Affiliations
- AstraZeneca (United Kingdom) (GB)
- University College London (GB)
- Corresponding author
- Goldrick, Stephen
- Umprecht, Alexandra
- ORCID
- Venue
- Processes
- Publisher
- MDPI AG
- Published
- 2020-09-17
- Volume
- 8
- Issue
- 9
- Pages
- 1179
- ISSN
- 2227-9717 (ISSN-L)
- OpenAlex
- W3086663814
- Cited by
- 48
- References
- 72
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 7 · 2023: 5 · 2022: 7 · 2021: 6
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Processes (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/I033270/1)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Viral Infectious Diseases and Gene Expression in Insects
- Keywords
- biopharmaceutical process development, partial least squares model, mammalian cell culture, antibody production, cation exchange chromatography, Fc fusion protein, monomer purity, low-volume sample analysis, microbioreactors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.