A Review of Active Hand Exoskeletons for Rehabilitation and Assistance
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Disabilities are a global issue due to the decrease in life quality and mobility of patients, especially people suffering from hand disabilities. This paper presents a review of active hand exoskeleton technologies, over the past decade, for rehabilitation, assistance, augmentation, and haptic devices. Hand exoskeletons are still an active research field due to challenges that engineers face and are trying to solve. Each hand exoskeleton has certain requirements to fulfil to achieve their aims. These requirements have been extracted and categorized into two sections: general and specific, to give a common platform for developing future devices. Since this is still a developing area, the requirements are also shaped according to the advances in the field. Technical challenges, such as size requirements, weight, ergonomics, rehabilitation, actuators, and sensors are all due to the complex anatomy and biomechanics of the hand. The hand is one of the most complex structures in the human body; therefore, to understand certain design approaches, the anatomy and biomechanics of the hand are addressed in this paper. The control of these devices is also an arising challenge due to the implementation of intelligent systems and new rehabilitation techniques. This includes intention detection techniques (electroencephalography (EEG), electromyography (EMG), admittance) and estimating applied assistance. Therefore, this paper summarizes the technology in a systematic approach and reviews the state of the art of active hand exoskeletons with a focus on rehabilitation and assistive devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langhorne, P., Bernhardt, J., & Kwakkel, G. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60325-5 · Cited by 2,726
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206 · cited 2×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodSoft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617 · cited 5×
“contracts when inflated and vice versa [50,54].”
BackgroundInfluentialTHE PREHENSILE MOVEMENTS OF THE HUMAN HAND
Napier, J. R. (1956) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.38b4.902 · Cited by 1,571 · cited 1×
“Therefore, the main and most used grips can be classified into three main categories namely Power, Precision, and Hook grips [28,29].”
BackgroundLum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 2×
“that highly repetitive task training can help the recovery of motor functions [10,11].”
BackgroundThe GRASP Taxonomy of Human Grasp Types
Feix, T., Romero, J., Schmiedmayer, H.-B., Dollar, A. M., & Kragic, D. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2015.2470657 · Cited by 1,024 · cited 1×
“Therefore, the main and most used grips can be classified into three main categories namely Power, Precision, and Hook grips [28,29].”
BackgroundThe Rutgers Master II-new design force-feedback glove
Bouzit, M., Burdea, G., Popescu, G., & Boian, R. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011262 · Cited by 570 · cited 2×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodCurrent hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System
In, H., Kang, B. B., Sin, M., & Cho, K.-J. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2362863 · Cited by 473 · cited 3×
“[47] 2015 Exo-Glove Assistance Tendon/cable (Underactuated) Complaint 40 N Flex/Extend 194 g hand Yes Wrist motion No”
BackgroundSoft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320 · cited 1×
“The author recommends reading [3,15–21] articles that capture other information regarding the technology surrounding hand exoskeletons especially [3,20,21]; these papers focus on soft robotic technologies including artificial muscles and tendon driven mechanisms.”
BackgroundThe anatomy and mechanics of the human hand.
TAYLOR, C. L., & SCHWARZ, R. J. (1955) · PubMed · Cited by 311
Yap, H. K., Lim, J. H., Nasrallah, F., Goh, J. C. H., & Yeow, R. C. H. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139889 · Cited by 299 · cited 5×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodInfluentialDevelopment and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
Schabowsky, C. N., Godfrey, S. B., Holley, R. J., & Lum, P. S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-36 · Cited by 280 · cited 5×
“[12] Redundant (four-bar linkage), gear train electric motors Cerebral vascular disease (Stroke)”
BackgroundInfluentialChiri, A., Vitiello, N., Giovacchini, F., Roccella, S., Vecchi, F., & Carrozza, M. C. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2144614 · Cited by 254 · cited 7×
“The trigger refers to buttons that the user must press to execute a certain task, such as closing the hand to grab an object or to open the hand for release [32].”
BackgroundMethodInfluentialFully Wearable Actuated Soft Exoskeleton for Grasping Assistance in Everyday Activities
Bützer, T., Lambercy, O., Arata, J., & Gassert, R. (2021) · Soft Robotics · doi:10.1089/soro.2019.0135 · Cited by 246 · cited 5×
“The number of electrodes used is generally less than the number of DOF of the hand; therefore, it can be challenging to get independent high DOF measurements [54,60,64,70,72].”
BackgroundMethodInfluentialKim, S., Nussbaum, M. A., Mokhlespour Esfahani, M. I., Alemi, M. M., Jia, B., & Rashedi, E. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.024 · Cited by 205
Brokaw, E. B., Black, I., Holley, R. J., & Lum, P. S. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2157705 · Cited by 197 · cited 2×
“SCRIPT and SaeboGlove are devices where individual finger movement can be accomplished, but the HandSOME device has been designed to combine the movement of the index, middle, ring, and little fingers, and the thumb is independent of the rest.”
MethodYap, H. K., Lim, J. H., Nasrallah, F., & Yeow, C.-H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00547 · Cited by 195
A Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint Axes
Cempini, M., Cortese, M., & Vitiello, N. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2315528 · Cited by 193 · cited 3×
“Devices with a matched axis mechanical structure have also been explored such as [31,32,62].”
BackgroundPortable Exoskeleton Glove With Soft Structure for Hand Assistance in Activities of Daily Living
Popov, D., Gaponov, I., & Ryu, J.-H. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2641932 · Cited by 191 · cited 3×
“present a new portable hand exoskeleton glove for the assistance of the activities of daily living [48].”
BackgroundAgarwal, P., Fox, J., Yun, Y., O’Malley, M. K., & Deshpande, A. D. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364915598388 · Cited by 189 · cited 4×
“[57,61,64,69,73] Redundant, Bowden cable transmission Cerebral vascular disease (Stroke)”
BackgroundInfluentialStaubli, P., Nef, T., Klamroth-Marganska, V., & Riener, R. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-46 · Cited by 181
Saraç, M., Solazzi, M., & Frisoli, A. (2019) · IEEE Transactions on Haptics · doi:10.1109/toh.2019.2924881 · Cited by 178
Moving toward Soft Robotics: A Decade Review of the Design of Hand Exoskeletons
Shahid, T., Gouwanda, D., Nurzaman, S. G., & Gopalai, A. A. (2018) · Biomimetics · doi:10.3390/biomimetics3030017 · Cited by 171
mano: A Wearable Hand Exoskeleton for Activities of Daily Living and Neurorehabilitation
Randazzo, L., Iturrate, I., Perdikis, S., & Millan, J. D. R. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2771329 · Cited by 167
RML Glove—An Exoskeleton Glove Mechanism With Haptics Feedback
MA, Z., & Ben-Tzvi, P. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2305842 · Cited by 163
A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping
Iqbal, J., Khan, H., Tsagarakis, N. G., & Caldwell, D. G. (2014) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2014.01.003 · Cited by 141 · cited 9×
“Encoders such as optical or magnetic (hall-effect) encoders are generally used on the electric motors themselves to track the revolutions per minute (rpm) or position of the output device [43,44,56,85].”
BackgroundInfluentialYap, H. K., Ang, B. W. K., Lim, J. H., Goh, J., & Yeow, C. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487535 · Cited by 122 · cited 2×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodDesign and Development of a Portable Exoskeleton for Hand Rehabilitation
Wang, D., Meng, Q., Meng, Q., Li, X., & Yu, H. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2878778 · Cited by 112 · cited 3×
“[35,38] Remote center of rotation (metal links with polymer splint), linear actuators Cerebral vascular disease (Stroke)”
BackgroundJointless structure and under-actuation mechanism for compact hand exoskeleton
In, H., Cho, K.-J., Kim, K., & Lee, B. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975394 · Cited by 111 · cited 3×
“This design features a soft jointless structure for assistive hand exoskeletons [76].”
BackgroundMethodAteş, S., Haarman, C. J. W., & Stienen, A. H. A. (2016) · Autonomous Robots · doi:10.1007/s10514-016-9589-6 · Cited by 110 · cited 1×
“The SCRIPT passive orthosis (SPO) [82] is an example of such a system as well as SaeboGlove [83] and HandSOME [84].”
MethodLi, M., He, B., Liang, Z., Zhao, C.-G., Chen, J., Zhuo, Y., Xu, G., Xie, J., & Althoefer, K. A. (2019) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2019.00034 · Cited by 106 · cited 5×
“[68,78] Compliant, linear actuator Cerebral vascular disease (Stroke)”
BackgroundMethodInfluentialA novel hand exoskeleton with series elastic actuation for modulated torque transfer
Marconi, D., Baldoni, A., McKinney, Z., Cempini, M., Crea, S., & Vitiello, N. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.06.001 · Cited by 98 · cited 4×
“[57,61,64,69,73] Redundant, Bowden cable transmission Cerebral vascular disease (Stroke)”
BackgroundInfluentialThe Role of Morphology of the Thumb in Anthropomorphic Grasping: A Review
Nanayakkara, V. K., Cotugno, G., Vitzilaios, N. I., Venetsanos, D. T., Nanayakkara, T., & Şahinkaya, M. N. (2017) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2017.00005 · Cited by 90
Computer games as a means of movement rehabilitation
Krichevets, A. N., Sirotkina, E. B., Yevsevicheva, I. V., & Zeldin, L. M. (1995) · Disability and Rehabilitation · doi:10.3109/09638289509166635 · Cited by 87 · cited 1×
“Studies have shown that the active involvement of the patient can strengthen and improve their motor learning as well as their cognitive–motor skills, which can lead to a more rapid recovery [9].”
BackgroundDesign and control of a wearable and force-controllable hand exoskeleton system
Jo, I., & Bae, J. (2016) · Mechatronics · doi:10.1016/j.mechatronics.2016.12.001 · Cited by 77 · cited 5×
“Very few researchers have implemented this type of actuator over the years such as [42,61,65,69].”
BackgroundInfluentialBoser, Q. A., Dawson, M. R. W., Schofield, J. S., Dziwenko, G., & Hebert, J. S. (2020) · Prosthetics and Orthotics International · doi:10.1177/0309364620963943 · Cited by 76 · cited 3×
“There was a study done in 2018 by [55] to determine the design requirements for hand assistive powered exoskeletons.”
BackgroundInfluentialFerris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-17 · Cited by 76 · cited 1×
“Although in some areas, the technology of exoskeletons is still actively being researched, it is clear that these devices will become part of our everyday accessories in the future [4].”
A portable and spring-guided hand exoskeleton for exercising flexion/extension of the fingers
Jo, I., Park, Y., Lee, J., & Bae, J. (2019) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2019.02.004 · Cited by 75 · cited 3×
“Devices using linear actuation usually have a fixed finger position at a certain point on the linear axis; therefore, the potentiometer or hall sensors are mounted on the linear axis to determine the position of the output [32,35,37,40,42,58,67,68,72].”
BackgroundTorras, A. B., Carrillo, J. A. C., Clavijo, M., & Castillo, J. J. (2016) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2016.06.022 · Cited by 71 · cited 3×
“Many systems al o include servo motors in their designs, which contain p tentiometers to detect the output angle [41,62,87].”
BackgroundA novel motion-coupling design for a jointless tendon-driven finger exoskeleton for rehabilitation
Yang, J., Xie, H., & Shi, J. (2016) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2015.12.010 · Cited by 69 · cited 2×
“[46,49,66,75] Compliant, tendon-driven/Bowden cable Cerebral vascular disease (Stroke)”
BackgroundA novel kinematic architecture for portable hand exoskeletons
Conti, R., Meli, E., & Ridolfi, A. (2016) · Mechatronics · doi:10.1016/j.mechatronics.2016.03.002 · Cited by 65 · cited 3×
“Many systems al o include servo motors in their designs, which contain p tentiometers to detect the output angle [41,62,87].”
BackgroundKinematics and design of a portable and wearable exoskeleton for hand rehabilitation
Cempini, M., Rossi, S., Lenzi, T., Cortese, M., Giovacchini, F., Vitiello, N., & Carrozza, M. C. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650414 · Cited by 64 · cited 4×
“[31,33] 2013 HX Rehabilitation Bowden cable (Underactuated) Matched axis 3 active 6 passive DIP–0.”
BackgroundMethodInfluentialDesign of a Series Elastic Transmission for hand exoskeletons
Bianchi, M., Cempini, M., Conti, R., Meli, E., Ridolfi, A., Vitiello, N., & Allotta, B. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.02.010 · Cited by 52 · cited 1×
“Very few researchers have implemented this type of actuator over the years such as [42,61,65,69].”
BackgroundTjahyono, A. P., Aw, K. C., Devaraj, H., Surendra, W. A., Haemmerle, E., & Travaš‐Sejdić, J. (2013) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439911311309951 · Cited by 50 · cited 8×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodInfluentialNovel soft bending actuator-based power augmentation hand exoskeleton controlled by human intention
Al-Fahaam, H., Davis, S., Nefti‐Meziani, S., & Theodoridis, T. (2018) · Intelligent Service Robotics · doi:10.1007/s11370-018-0250-4 · Cited by 50 · cited 5×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodInfluentialA multi-DOF robotic exoskeleton interface for hand motion assistance
Iqbal, J., Tsagarakis, N. G., & Caldwell, D. G. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090458 · Cited by 48 · cited 6×
“Base-to-distal devices that have mechanical links in series are also popular if the device needs to fit various users and maintain a simple design [56,67,85,87].”
BackgroundInfluentialDesign and Development of a Hand Exoskeleton for Rehabilitation Following Stroke
Rahman, M. A., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.279 · Cited by 45 · cited 6×
“It has been shown that the user’s interaction with the training can improve their recovery and strengthen their cognitive function [58].”
BackgroundMethodInfluentialAnalysis of Finger Muscular Forces using a Wearable Hand Exoskeleton System
Kim, S., Lee, J., & Bae, J. (2017) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(16)60434-1 · Cited by 44 · cited 2×
“A different appro ch was aken by [58,66,68,70,86]; these types made use of a hi spring metal plate that is compressed or tensioned to fl x and extend the fingers, respectively.”
MethodPower-Assistive Finger Exoskeleton With a Palmar Opening at the Fingerpad
Heo, P., & Kim, J. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2325948 · Cited by 40 · cited 8×
“Various methods have been developed to acquire the ROM of the fingers by the use of inflatable flexible materials [51,52], pneumatic cylinders [60,89], bellow-shaped systems [53], or artificial muscles [45,54,90].”
BackgroundMethodInfluentialHand Exoskeleton Systems—Overview
Ferguson, P. W., Shen, Y., & Rosén, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00008-4 · Cited by 39
Hand Exo-Muscular System for Assisting Astronauts During Extravehicular Activities
Villoslada, Á., Rivera, C., Escudero, N., Martín, F., Blanco, D., & Moreno, L. E. (2018) · Soft Robotics · doi:10.1089/soro.2018.0020 · Cited by 39 · cited 1×
“These types of exoskeletons are generally produced for military purposes, but it is also used in the space program to help astronauts flex and extend their fingers through the stiff spacesuit [80,81].”
BackgroundAn Original Classification of Rehabilitation Hand Exoskeletons
Troncossi, M. (2016) · Journal of Robotics and Mechanical Engineering Research · doi:10.24218/jrmer.2016.18 · Cited by 37
Design of a thumb exoskeleton for hand rehabilitation
Lambercy, O., Schröder, D., Zwicker, S., & Gassert, R. (2013) · International Convention on Rehabilitation Engineering & Assistive Technology · Cited by 35
Force and motion control of a tendon-driven hand exoskeleton actuated by shape memory alloys
Kazeminasab, S., Hadi, A., Alipour, K., & Elahinia, M. (2018) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-01-2018-0020 · Cited by 32 · cited 6×
“• Shape Memory Alloy (SMA): This type of actuator was explored by [39,49].”
BackgroundInfluentialExoskeleton design and adaptive compliance control for hand rehabilitation
Akgün, G., Cetin, A. E., & Kaplanoğlu, E. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331219874976 · Cited by 31 · cited 3×
“Devices using linear actuation usually have a fixed finger position at a certain point on the linear axis; therefore, the potentiometer or hall sensors are mounted on the linear axis to determine the position of the output [32,35,37,40,42,58,67,68,72].”
BackgroundTailor-Made Hand Exoskeletons at the University of Florence: From Kinematics to Mechatronic Design
Secciani, N., Bianchi, M., Ridolfi, A., Vannetti, F., Volpe, Y., Governi, L., Bianchini, M., & Allotta, B. (2019) · Machines · doi:10.3390/machines7020022 · Cited by 30
Reitan, I., Dahlin, L. B., & Rosberg, H. (2019) · Health and Quality of Life Outcomes · doi:10.1186/s12955-019-1215-9 · Cited by 29 · cited 1×
“Most upper limb disabilities are located at the hand or forearm, which usually occurs due to injuries [6].”
BackgroundA Two-Axis Goniometric Sensor for Tracking Finger Motion
Wang, L., Meydan, T., & Williams, P. (2017) · Sensors · doi:10.3390/s17040770 · Cited by 29 · cited 1×
“This diagram was taken from [27], which is an open-source article.”
BackgroundKinetostatic analysis and design optimization of an n-finger underactuated hand exoskeleton
Battezzato, A. (2015) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2014.12.007 · Cited by 18 · cited 2×
“Many exoskeletons were designed to r duce the size and add more DOF for the hand, which led to the remote ce ter of rotation design [34] (Figure 6b).”
BackgroundA REVIEW REGARDING HAND EXOSKELETON TECHNOLOGIES FOR REHABILITATION
Birouaș, F., Avram, F., Nilgesz, A., & Mihalca, V. O. (n.d.) · Recent Innovations in Mechatronics · doi:10.17667/riim.2018.1/9 · Cited by 10
Metadata
- Authors
- du Plessis, T., Djouani, K., & Oosthuizen, C.
- Venue
- Robotics
- Publisher
- MDPI AG
- Published
- 2021-03-03
- Volume
- 10
- Issue
- 1
- Pages
- 40
- ISSN
- 2218-6581 (ISSN-L)
- OpenAlex
- W3133584254
- Cited by
- 218
- References
- 61
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.