Fabrication of a Microneedle/CNT Hierarchical Micro/Nano Surface Electrochemical Sensor and Its In-Vitro Glucose Sensing Characterization
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report fabrication of a microneedle-based three-electrode integrated electrochemical sensor and in-vitro characterization of this sensor for glucose sensing applications. A piece of silicon was sequentially dry and wet etched to form a 15 × 15 array of tall (approximately 380 µm) sharp silicon microneedles. Iron catalyst was deposited through a SU-8 shadow mask to form the working electrode and counter electrode. A multi-walled carbon nanotube forest was grown directly on the silicon microneedle array and platinum nano-particles were electrodeposited. Silver was deposited on the Si microneedle array through another shadow mask and chlorinated to form a Ag/AgCl reference electrode. The 3-electrode electrochemical sensor was tested for various glucose concentrations in the range of 3~20 mM in 0.01 M phosphate buffered saline (PBS) solution. The sensor’s amperometric response to the glucose concentration is linear and its sensitivity was found to be 17.73 ± 3 μA/mM-cm2. This microneedle-based sensor has a potential to be used for painless diabetes testing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · cited 1×
“There have been numerous investigations to develop alternative methods of glucose monitoring to avoid frequent fingertip blood sampling, including sampling from alternate sites other than the fingertip [2], monitoring tear fluid instead of blood droplets [3], non-invasive optical methods [4], and continuous glucose mo…”
BackgroundTechnologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · cited 1×
“There have been numerous investigations to develop alternative methods of glucose monitoring to avoid frequent fingertip blood sampling, including sampling from alternate sites other than the fingertip [2], monitoring tear fluid instead of blood droplets [3], non-invasive optical methods [4], and continuous glucose mo…”
BackgroundA flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173
Cited by
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Zhi, D., Yang, T., O'Hagan, J., Zhang, S., & Donnelly, R. F. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.06.032 · Cited by 637
Broza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Metadata
- Authors
- Yoon, Y., Lee, G., Yoo, K., & Lee, J.-B.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-12-04
- Volume
- 13
- Issue
- 12
- Pages
- 16672-16681
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2056887835
- Cited by
- 85
- References
- 4
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.