The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Continuous Monitoring of Turning in Patients with Movement Disability
Open accessAbstract
Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson’s disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the home is feasible for people with PD and elderly people. We developed an algorithm to detect and characterize turns during gait, using wearable inertial sensors. First, we validate the turning algorithm in the laboratory against a Motion Analysis system and against a video analysis of 21 PD patients and 19 control (CT) subjects wearing an inertial sensor on the pelvis. Compared to Motion Analysis and video, the algorithm maintained a sensitivity of 0.90 and 0.76 and a specificity of 0.75 and 0.65, respectively. Second, we apply the turning algorithm to data collected in the home from 12 PD and 18 CT subjects. The algorithm successfully detects turn characteristics, and the results show that, compared to controls, PD subjects tend to take shorter turns with smaller turn angles and more steps. Furthermore, PD subjects show more variability in all turn metrics throughout the day and the week.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The present findings are also in line with other studies measuring remote physical activity in PD, which were traditionally performed over shorter timeframes (i.e., 1 day to 1 week).”
From Evaluation of smartphone‐based testing to generate exploratory outcome measures in a phase 1 Parkinson's disease clinical trial (2018) · cites this paper as [48]
In the citing paper
“These reported significantly less motor activity in PD compared to controls (e.g., fewer steps and shorter bouts of physical activity,48, 70) some of which were related to disease severity71”
From Evaluation of smartphone‐based testing to generate exploratory outcome measures in a phase 1 Parkinson's disease clinical trial (2018) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,252
Physical performance measures in the clinical setting
Studenski, S., Perera, S., Wallace, D., Chandler, J. M., Duncan, P. W., Rooney, E., Fox, M., & Guralnik, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51104.x · Cited by 1,218
Ganz, D., Bao, Y., Shekelle, P., & Rubenstein, L. (2007) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.297.1.77 · Cited by 878
Prospective assessment of falls in Parkinson's disease
Bloem, B. R., Grimbergen, Y. A. M., Cramer, M., Willemsen, M., & Zwinderman, A. H. (2001) · Journal of Neurology · doi:10.1007/s004150170047 · Cited by 869
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693
A meta‐analysis of six prospective studies of falling in Parkinson's disease
Pickering, R. M., Grimbergen, Y. A. M., Rigney, U., Ashburn, A., Mazibrada, G., Wood, B. H., Gray, P., Kerr, G., & Bloem, B. R. (2007) · Movement Disorders · doi:10.1002/mds.21598 · Cited by 587
Properties of the ‘Timed Up and Go’ Test: More than Meets the Eye
Herman, T., Giladi, N., & Hausdorff, J. M. (2010) · Gerontology · doi:10.1159/000314963 · Cited by 575
Fall Frequency and Characteristics and the Risk of Hip Fractures
Cumming, R. G., & Klineberg, R. J. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb06540.x · Cited by 418
Moe‐Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00089-8 · Cited by 406
Zampieri, C., Salarian, A., Carlson‐Kuhta, P., Aminian, K., Nutt, J. G., & Horak, F. B. (2009) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.173740 · Cited by 367
Self-citation
Cited by
Sorted by citations
Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B. P. L., & Yang, G. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443
Free‐living monitoring of Parkinson's disease: Lessons from the field
Din, S. D., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016) · Movement Disorders · doi:10.1002/mds.26718 · Cited by 377
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 331
Lipsmeier, F., Taylor, K. I., Kilchenmann, T., Wolf, D., Scotland, A., Schjodt‐Eriksen, J., Cheng, W., Fernandez‐Garcia, I., Siebourg‐Polster, J., Jin, L., et al. (2018) · Movement Disorders · doi:10.1002/mds.27376 · Cited by 266
Role of Body-Worn Movement Monitor Technology for Balance and Gait Rehabilitation
Horak, F. B., King, L. A., & Mancini, M. (2014) · Physical Therapy · doi:10.2522/ptj.20140253 · Cited by 227
Self-citationRemote Physical Activity Monitoring in Neurological Disease: A Systematic Review.
Block, V. A. J., Pitsch, E., Tahir, P., Cree, B. A. C., Allen, D. D., & Gelfand, J. M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154335 · Cited by 198
“Ford et al, 2010 [131] Mild /moderate StepWatch activity monitor (b*) Walking /gait/ LE physical activity Crosssectional > 51 12 N/A 7 days Private foundation”
BackgroundBuckley, C., Alcock, L., Ardle, R. M., Rehman, R. Z. U., Din, S. D., Mazzà, C., Yarnall, A. J., & Rochester, L. (2019) · Brain Sciences · doi:10.3390/brainsci9020034 · Cited by 204
Continuous monitoring of turning in Parkinson’s disease: Rehabilitation potential
Mancini, M., El-Gohary, M., Pearson, S., McNames, J., Schlueter, H., Nutt, J. G., King, L. A., & Horak, F. B. (2015) · NeuroRehabilitation · doi:10.3233/nre-151236 · Cited by 175
Self-citationMeasuring freezing of gait during daily-life: an open-source, wearable sensors approach
Mancini, M., Shah, V. V., Stuart, S., Curtze, C., Horak, F. B., Safarpour, D., & Nutt, J. G. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00774-3 · Cited by 180
Self-citationClinical and methodological challenges for assessing freezing of gait: Future perspectives
Mancini, M., Bloem, B. R., Horak, F. B., Lewis, S. J. G., Nieuwboer, A., & Nonnekes, J. H. (2019) · Movement Disorders · doi:10.1002/mds.27709 · Cited by 169
Self-citationCiuti, G., Ricotti, L., Menciassi, A., & Dario, P. (2015) · Sensors · doi:10.3390/s150306441 · Cited by 172
Mancini, M., Schlueter, H., El‐Gohary, M., Mattek, N., Duncan, C., Kaye, J. A., & Horak, F. B. (2016) · The Journals of Gerontology Series A · doi:10.1093/gerona/glw019 · Cited by 172
Self-citationRochester, L., Mazzà, C., Mueller, A., Caulfield, B., Carthy, M. M., Becker, C., Miller, R. R., Piraino, P., Viceconti, M., Dartee, W., et al. (2020) · Digital Biomarkers · doi:10.1159/000512513 · Cited by 145
Potential of APDM mobility lab for the monitoring of the progression of Parkinson’s disease
Mancini, M., & Horak, F. B. (2016) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1153421 · Cited by 140
Self-citationThe Role of Wearable Devices in Chronic Disease Monitoring and Patient Care: A Comprehensive Review
Jafleh, E. A., Alnaqbi, F. A., Almaeeni, H. A., Faqeeh, S., Alzaabi, M. A., & Al Zaman, K. (2024) · Cureus · doi:10.7759/cureus.68921 · Cited by 125
Delbroek, T., Vermeylen, W., & Spildooren, J. (2017) · Journal of Physical Therapy Science · doi:10.1589/jpts.29.1137 · Cited by 127
Palmerini, L., Rocchi, L., Mazilu, S., Gazit, E., Hausdorff, J. M., & Chiari, L. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00394 · Cited by 117
Self-citationPham, M. H., Elshehabi, M., Haertner, L., Din, S. D., Srulijes, K., Heger, T., Synofzik, M., Hobert, M. A., Faber, G. S., Hansen, C., et al. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00457 · Cited by 112
Continuous home monitoring of Parkinson’s disease using inertial sensors: A systematic review
Sica, M., Tedesco, S. A., Crowe, C., Kenny, L., Moore, K., Timmons, S., Barton, J. J., O’Flynn, B., & Komaris, D.-S. (2021) · PLoS ONE · doi:10.1371/journal.pone.0246528 · Cited by 124
Manor, B. D., Yu, W., Zhu, H., Harrison, R., Lo, O., Lipsitz, L. A., Travison, T. G., Pascual‐Leone, Á., & Zhou, J. (2018) · JMIR mhealth and uhealth · doi:10.2196/mhealth.8815 · Cited by 107
Din, S. D., Kirk, C., Yarnall, A. J., Rochester, L., & Hausdorff, J. M. (2021) · Journal of Parkinson s Disease · doi:10.3233/jpd-202471 · Cited by 108
Tamburini, P., Storm, F. A., Buckley, C., Bisi, M. C., Stagni, R., & Mazzà, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.024 · Cited by 105
Shah, V. V., McNames, J., Mancini, M., Carlson‐Kuhta, P., Spain, R., Nutt, J. G., El‐Gohary, M., Curtze, C., & Horak, F. B. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00781-4 · Cited by 96
Self-citationUsing a smartwatch and smartphone to assess early Parkinson’s disease in the WATCH-PD study
Adams, J. L., Kangarloo, T., Tracey, B., O’Donnell, P., Volfson, D., Latzman, R. D., Zach, N., Alexander, R., Bergethon, P., Cosman, J., et al. (2023) · npj Parkinson's Disease · doi:10.1038/s41531-023-00497-x · Cited by 98
Turn Around Freezing: Community-Living Turning Behavior in People with Parkinson’s Disease
Mancini, M., Weiss, A., Herman, T., & Hausdorff, J. M. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00018 · Cited by 96
Self-citationGalperin, I., Hillel, I., Din, S. D., Bekkers, E. M. J., Nieuwboer, A., Abbruzzese, G., Avanzino, L., Nieuwhof, F., Bloem, B. R., Rochester, L., et al. (2019) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2019.01.022 · Cited by 96
Rast, F. M., & Labruyère, R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00779-y · Cited by 95
Morgan, C., Rolinski, M., McNaney, R., Jones, B., Rochester, L., Maetzler, W., Craddock, I. J., & Whone, A. L. (2020) · Journal of Parkinson s Disease · doi:10.3233/jpd-191781 · Cited by 93
Atrsaei, A., Corrà, M. F., Dadashi, F., Vila‐Chã, N., Maia, L. F., Mariani, B., Maetzler, W., & Aminian, K. (2021) · npj Parkinson s Disease · doi:10.1038/s41531-021-00171-0 · Cited by 90
Real-life gait assessment in degenerative cerebellar ataxia
Ilg, W., Seemann, J., Giese, M. A., Traschütz, A., Schöls, L. J., Timmann, D., & Synofzik, M. (2020) · Neurology · doi:10.1212/wnl.0000000000010176 · Cited by 95
Shah, V. V., McNames, J., Mancini, M., Carlson‐Kuhta, P., Spain, R., Nutt, J. G., El‐Gohary, M., Curtze, C., & Horak, F. B. (2020) · Journal of Neurology · doi:10.1007/s00415-020-09696-5 · Cited by 87
Self-citationDigital Biomarkers of Mobility in Parkinson’s Disease During Daily Living
Shah, V. V., McNames, J., Mancini, M., Carlson‐Kuhta, P., Nutt, J. G., El‐Gohary, M., Lapidus, J., Horak, F. B., & Curtze, C. (2020) · Journal of Parkinson s Disease · doi:10.3233/jpd-201914 · Cited by 88
Self-citationSharp, M. K., Carare, R. O., & Martin, B. A. (2019) · Fluids and Barriers of the CNS · doi:10.1186/s12987-019-0132-y · Cited by 87
Kirk, C., Küderle, A., Micó-Amigo, M. E., Bonci, T., Paraschiv-Ionescu, A., Ullrich, M., Soltani, A., Gazit, E., Salis, F., Alcock, L., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-51766-5 · Cited by 86
Self-citationLeach, J. M., Mellone, S., Palumbo, P., Bandinelli, S., & Chiari, L. (2018) · Scientific Reports · doi:10.1038/s41598-018-22492-6 · Cited by 81
Self-citationWearable Inertial Sensors to Assess Gait during the 6-Minute Walk Test: A Systematic Review
Storm, F. A., Cesareo, A., Reni, G., & Biffi, E. (2020) · Sensors · doi:10.3390/s20092660 · Cited by 88
Human Identification From Freestyle Walks Using Posture-Based Gait Feature
Khamsemanan, N., Nattee, C., & Jianwattanapaisarn, N. (2017) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2017.2738611 · Cited by 80
Ghassemi, N. H., Hannink, J., Martindale, C. F., Gaßner, H., Müller, M., Klucken, J., & Eskofier, B. M. (2018) · Sensors · doi:10.3390/s18010145 · Cited by 86
Nguyen, H., Lebel, K., Bogard, S., Goubault, É., Boissy, P., & Duval, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2745418 · Cited by 75
Kroneberg, D., Elshehabi, M., Meyer, A.-C., Otte, K., Doss, S., Paul, F., Nussbaum, S., Berg, D., Kühn, A. A., Maetzler, W., et al. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00435 · Cited by 76
Naghavi, N., & Wade, E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2910165 · Cited by 73
Cognitive associations with comprehensive gait and static balance measures in Parkinson's disease
Morris, R., Martini, D. N., Smulders, K., Kelly, V. E., Zabetian, C. P., Poston, K. L., Hiller, A., Chung, K. A., Yang, L., Hu, S., et al. (2019) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2019.06.014 · Cited by 72
Self-citationNguyen, H., Lebel, K., Boissy, P., Bogard, S., Goubault, É., & Duval, C. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0241-2 · Cited by 71
Lu, R., Xu, Y., Li, X., Fan, Y., Zeng, W., Tan, Y., Ren, K., Chen, W., & Cao, X. (2020) · Parkinson s Disease · doi:10.1155/2020/4693019 · Cited by 69
Consensus based framework for digital mobility monitoring
Kluge, F., Din, S. D., Cereatti, A., Gaßner, H., Hansen, C., Helbostad, J. L., Klucken, J., Küderle, A., Müller, A., Rochester, L., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0256541 · Cited by 73
Toward Real-Time Automated Detection of Turns during Gait Using Wearable Inertial Measurement Units
Novak, D., Goršič, M., Podobnik, J., & Munih, M. (2014) · Sensors · doi:10.3390/s141018800 · Cited by 64
Inertial Motion Capture-Based Wearable Systems for Estimation of Joint Kinetics: A Systematic Review
Lee, C. J., & Lee, J. K. (2022) · Sensors · doi:10.3390/s22072507 · Cited by 72
A narrative review of turning deficits in people with Parkinson’s disease
Hulbert, S., Ashburn, A., Robert, L., & Verheyden, G. (2014) · Disability and Rehabilitation · doi:10.3109/09638288.2014.961661 · Cited by 63
Belluscio, V., Stuart, S., Bergamini, E., Vannozzi, G., & Mancini, M. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2019.07.024 · Cited by 63
Self-citationStuart, S., & Mancini, M. (2019) · Neurology Report · doi:10.1097/npt.0000000000000286 · Cited by 60
Self-citationZhang, W., Ling, Y., Chen, Z., Ren, K., Chen, S., Huang, P., & Tan, Y. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01163-z · Cited by 59
The use of wearable/portable digital sensors in Huntington's disease: A systematic review
Tortelli, R., Rodrigues, F. B., & Wild, E. J. (2021) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2021.01.006 · Cited by 55
Buckley, C., Galna, B., Rochester, L., & Mazzà, C. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.06.166 · Cited by 57
Clemens, S. M., GAILEY, R. S., Bennett, C., Pasquina, P. F., Kirk-Sanchez, N. J., & GAUNAURD, I. A. (2017) · Clinical Rehabilitation · doi:10.1177/0269215517728324 · Cited by 56
Dance for Parkinson’s—The effects on whole body co-ordination during turning around
Hulbert, S., Ashburn, A., Roberts, L. C., & Verheyden, G. (2017) · Complementary Therapies in Medicine · doi:10.1016/j.ctim.2017.03.012 · Cited by 55
Effect of Fear of Falling on Turning Performance in Parkinson’s Disease in the Lab and at Home
Haertner, L., Elshehabi, M., Zaunbrecher, L., Pham, M. H., Maetzler, C., van Uem, J. M. T., Hobert, M. A., Hucker, S., Nussbaum, S., Berg, D., et al. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00078 · Cited by 55
Cortical correlates in upright dynamic and static balance in the elderly
Rubega, M., Formaggio, E., Marco, R. D., Bertuccelli, M., Tortora, S., Menegatti, E., Cattelan, M., Bonato, P., Masiero, S., & Felice, A. D. (2021) · Scientific Reports · doi:10.1038/s41598-021-93556-3 · Cited by 54
Moing, A. G. L., Seferian, A., Moraux, A., Annoussamy, M., Dorveaux, É., Gasnier, E., Hogrel, J., Voït, T., Vissière, D., & Servais, L. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156696 · Cited by 52
Rovini, E., Maremmani, C., & Cavallo, F. (2018) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2018.0035 · Cited by 50
Rehman, R. Z. U., Klocke, P., Hryniv, S., Galna, B., Rochester, L., Din, S. D., & Alcock, L. (2020) · Sensors · doi:10.3390/s20185377 · Cited by 51
Rovini, E., Maremmani, C., & Cavallo, F. (2020) · Sensors · doi:10.3390/s20092630 · Cited by 51
Bernad‐Elazari, H., Herman, T., Mirelman, A., Gazit, E., Giladi, N., & Hausdorff, J. M. (2016) · Journal of Neurology · doi:10.1007/s00415-016-8164-6 · Cited by 49
Soltani, A., Aminian, K., Mazzà, C., Cereatti, A., Palmerini, L., Bonci, T., & Paraschiv-Ionescu, A. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3111681 · Cited by 48
Bertoli, M., Croce, U. D., Cereatti, A., & Mancini, M. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.09.001 · Cited by 46
Self-citationShah, V. V., McNames, J., Harker, G. R., Mancini, M., Carlson‐Kuhta, P., Nutt, J. G., El‐Gohary, M., Curtze, C., & Horak, F. B. (2020) · Sensors · doi:10.3390/s20205769 · Cited by 46
Self-citationBoekesteijn, R. J., Smolders, J. M. H., Busch, V., Geurts, A. C. H., & Smulders, K. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04074-2 · Cited by 44
Pham, M. H., Warmerdam, E., Elshehabi, M., Schlenstedt, C., Bergeest, L. M., Heller, M. K., Haertner, L., Ferreira, J. J., Berg, D., Schmidt, G. U., et al. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00652 · Cited by 44
Comparison of tri-axial accelerometers step-count accuracy in slow walking conditions
Feng, Y., Wong, C. K., Janeja, V. P., Kuber, R., & Mentis, H. M. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.12.014 · Cited by 43
Clemens, S. M., Kim, K. J., GAILEY, R. S., Kirk-Sanchez, N. J., Kristal, A., & GAUNAURD, I. A. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.12.007 · Cited by 43
Micó-Amigo, M. E., Kingma, I., Heinzel, S., Rispens, S. M., Heger, T., Nussbaum, S., van Lummel, R. C., Berg, D., Maetzler, W., & van Dieën, J. H. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00059 · Cited by 42
Walking Along Curved Trajectories. Changes With Age and Parkinson's Disease. Hints to Rehabilitation
Godi, M., Giardini, M., & Schieppati, M. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00532 · Cited by 42
Detection of Gait From Continuous Inertial Sensor Data Using Harmonic Frequencies
Ullrich, M., Küderle, A., Hannink, J., Din, S. D., Gaßner, H., Marxreiter, F., Klucken, J., Eskofier, B. M., & Kluge, F. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2975361 · Cited by 39
Ayachi, F. S., Nguyen, H., Lavigne–Pelletier, C., Goubault, É., Boissy, P., & Duval, C. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/3/442 · Cited by 38
Pham, M. H., Elshehabi, M., Haertner, L., Heger, T., Hobert, M. A., Faber, G. S., Salkovic, D., Ferreira, J. J., Berg, D., Sánchez‐Ferro, Á., et al. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00135 · Cited by 38
Reference values of gait using APDM movement monitoring inertial sensor system
Fang, X., Liu, C., & Jiang, Z. (2018) · Royal Society Open Science · doi:10.1098/rsos.170818 · Cited by 38
Vitório, R. R., Hasegawa, N., Carlson‐Kuhta, P., Nutt, J. G., Horak, F. B., Mancini, M., & Shah, V. V. (2020) · Journal of Parkinson s Disease · doi:10.3233/jpd-202289 · Cited by 37
Self-citationReal‐Life Turning Movements Capture Subtle Longitudinal and Preataxic Changes in Cerebellar Ataxia
Thierfelder, A., Seemann, J., John, N., Harmuth, F., Giese, M. A., Schüle, R., Schöls, L. J., Timmann, D., Synofzik, M., & Ilg, W. (2022) · Movement Disorders · doi:10.1002/mds.28930 · Cited by 38
Salaorni, F., Bonardi, G., Schena, F. F., Tinazzi, M., & Gandolfi, M. (2023) · Expert Review of Medical Devices · doi:10.1080/17434440.2023.2298342 · Cited by 40
Barrois, R., Ricard, D., Oudre, L., Tlili, L., Provost, C., Vienne-Jumeau, A., Vidal, P., Buffat, S., & Yelnik, A. P. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00194 · Cited by 35
Comparison of calibration methods for accelerometers used in human motion analysis
Nez, A., Fradet, L., Laguillaumie, P., Monnet, T., & Lacouture, P. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.08.004 · Cited by 34
Wearable Accelerometer and sEMG-Based Upper Limb BSN for Tele-Rehabilitation
Baraka, A., Shaban, H. A., El-Nasr, M. A., & Attallah, O. (2019) · Applied Sciences · doi:10.3390/app9142795 · Cited by 34
Warmerdam, E., Romijnders, R., Welzel, J., Hansen, C., Schmidt, G. U., & Maetzler, W. (2020) · Sensors · doi:10.3390/s20205963 · Cited by 35
Cheng, W., Bourke, A. K., Lipsmeier, F., Bernasconi, C., Belachew, S. M., Gossens, C., Graves, J. S., Montalbán, X., & Lindemann, M. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.11.025 · Cited by 34
Yang, Y., Chen, L., Pang, J., Huang, X., Meng, L., & Ming, D. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3172725 · Cited by 33
Turcato, A. M., Godi, M., Giardini, M., Arcolin, I., Nardone, A., Giordano, A., & Schieppati, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197264 · Cited by 32
Gait Stability Has Phase-Dependent Dual-Task Costs in Parkinson’s Disease
Fino, P. C., Mancini, M., Curtze, C., Nutt, J. G., & Horak, F. B. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00373 · Cited by 32
Self-citationRehman, R. Z. U., Guan, Y., Shi, J. Q., Alcock, L., Yarnall, A. J., Rochester, L., & Din, S. D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.808518 · Cited by 31
Turning Analysis during Standardized Test Using On-Shoe Wearable Sensors in Parkinson’s Disease
Ghassemi, N. H., Hannink, J., Roth, N., Gaßner, H., Marxreiter, F., Klucken, J., & Eskofier, B. M. (2019) · Sensors · doi:10.3390/s19143103 · Cited by 31
Gait and trunk kinematics during prolonged turning in Parkinson's disease with freezing of gait
Mitchell, T., Conradsson, D. M., & Paquette, C. (2019) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2019.04.011 · Cited by 31
Stuart, S., Parrington, L., Martini, D. N., Kreter, N., Chesnutt, J. C., Fino, P. C., & King, L. A. (2019) · Journal of Neurotrauma · doi:10.1089/neu.2019.6450 · Cited by 30
Belluscio, V., Bergamini, E., Tramontano, M., Formisano, R., Buzzi, M. G., & Vannozzi, G. (2020) · Sensors · doi:10.3390/s20185244 · Cited by 29
Kamil, R. J., Bakar, D., Ehrenburg, M., Wei, E. X., Pletnikova, A., Xiao, G., Oh, E. S., Mancini, M., & Agrawal, Y. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.529661 · Cited by 29
Self-citationRoussos, G., Herrero, T. R., Hill, D. L., Dowling, A. V., L. T. M. Müller, M., Evers, L. J. W., Burton, J., Derungs, A., Fisher, K., Kilambi, K. P., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00643-4 · Cited by 28
Are gait variability and stability measures influenced by directional changes?
Riva, F., Grimpampi, E., Mazzà, C., & Stagni, R. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-56 · Cited by 28
Arcolin, I., Corna, S., Giardini, M., Giordano, A., Nardone, A., & Godi, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0689-3 · Cited by 28
Local dynamic stability during long-fatiguing walks in people with multiple sclerosis
Arpan, I., Fino, P. C., Fling, B. W., & Horak, F. B. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.10.032 · Cited by 27
Self-citationBoekesteijn, R. J., Smolders, J. M. H., Busch, V., Keijsers, N., Geurts, A. C. H., & Smulders, K. (2022) · PeerJ · doi:10.7717/peerj.14054 · Cited by 27
Bath, J., & Wang, D. D. (2024) · Neurotherapeutics · doi:10.1016/j.neurot.2024.e00354 · Cited by 26
Atrsaei, A., Dadashi, F., Mariani, B., Gonzenbach, R. R., & Aminian, K. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3076707 · Cited by 29
Atrsaei, A., Hansen, C., Elshehabi, M., Solbrig, S., Berg, D., Liepelt‐Scarfone, I., Maetzler, W., & Aminian, K. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.722830 · Cited by 25
Metadata
- Authors
- El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L.
- Affiliations
- APDM, Inc., Portland, OR 97201, USA
- APDM (United States) (US)
- Oregon Health & Science University (US)
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-12-27
- Volume
- 14
- Issue
- 1
- Pages
- 356-369
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC3926561
- OpenAlex
- W2067428313
- Cited by
- 258
- References
- 33
- Citations by year
- 2026: 17 · 2025: 20 · 2024: 16 · 2023: 21 · 2022: 26 · 2021: 27 · 2020: 25 · 2019: 28 · 2018: 23 · 2017: 29 · 2016: 16 · 2015: 5 · 2014: 5
- FWCI
- 22.53
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PDXScholar (Portland State University) (submittedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institute on Aging (R01AG006457)
- National Institute of Neurological Disorders and Stroke (R41NS076088)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Keywords
- turning, Parkinson's disease, mobility impairment, wearable inertial sensors, fall risk, freezing of gait, gait analysis, home monitoring, older adults, daily activities, turning angle, step count
- MeSH terms
- Aged, Algorithms, Female, Persons with Disabilities, Humans, Male, Middle Aged, Movement, Parkinson Disease, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review