The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Continuous Monitoring of Turning in Patients with Movement Disability
Open accessAbstract
Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson’s disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the home is feasible for people with PD and elderly people. We developed an algorithm to detect and characterize turns during gait, using wearable inertial sensors. First, we validate the turning algorithm in the laboratory against a Motion Analysis system and against a video analysis of 21 PD patients and 19 control (CT) subjects wearing an inertial sensor on the pelvis. Compared to Motion Analysis and video, the algorithm maintained a sensitivity of 0.90 and 0.76 and a specificity of 0.75 and 0.65, respectively. Second, we apply the turning algorithm to data collected in the home from 12 PD and 18 CT subjects. The algorithm successfully detects turn characteristics, and the results show that, compared to controls, PD subjects tend to take shorter turns with smaller turn angles and more steps. Furthermore, PD subjects show more variability in all turn metrics throughout the day and the week.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The present findings are also in line with other studies measuring remote physical activity in PD, which were traditionally performed over shorter timeframes (i.e., 1 day to 1 week).”
From Evaluation of smartphone‐based testing to generate exploratory outcome measures in a phase 1 Parkinson's disease clinical trial (2018) · cites this paper as [48]
In the citing paper
“These reported significantly less motor activity in PD compared to controls (e.g., fewer steps and shorter bouts of physical activity,48, 70) some of which were related to disease severity71”
From Evaluation of smartphone‐based testing to generate exploratory outcome measures in a phase 1 Parkinson's disease clinical trial (2018) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,252
Physical performance measures in the clinical setting
Studenski, S., Perera, S., Wallace, D., Chandler, J. M., Duncan, P. W., Rooney, E., Fox, M., & Guralnik, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51104.x · Cited by 1,218
Ganz, D., Bao, Y., Shekelle, P., & Rubenstein, L. (2007) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.297.1.77 · Cited by 878
Prospective assessment of falls in Parkinson's disease
Bloem, B. R., Grimbergen, Y. A. M., Cramer, M., Willemsen, M., & Zwinderman, A. H. (2001) · Journal of Neurology · doi:10.1007/s004150170047 · Cited by 869
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693
A meta‐analysis of six prospective studies of falling in Parkinson's disease
Pickering, R. M., Grimbergen, Y. A. M., Rigney, U., Ashburn, A., Mazibrada, G., Wood, B. H., Gray, P., Kerr, G., & Bloem, B. R. (2007) · Movement Disorders · doi:10.1002/mds.21598 · Cited by 587
Properties of the ‘Timed Up and Go’ Test: More than Meets the Eye
Herman, T., Giladi, N., & Hausdorff, J. M. (2010) · Gerontology · doi:10.1159/000314963 · Cited by 575
Fall Frequency and Characteristics and the Risk of Hip Fractures
Cumming, R. G., & Klineberg, R. J. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb06540.x · Cited by 418
Moe‐Nilssen, R. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00089-8 · Cited by 406
Zampieri, C., Salarian, A., Carlson‐Kuhta, P., Aminian, K., Nutt, J. G., & Horak, F. B. (2009) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.173740 · Cited by 367
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 258
Kuhner, A., Schubert, T., Cenciarini, M., Wiesmeier, I. K., Coenen, V. A., Burgard, W., Weiller, C., & Maurer, C. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00607 · Cited by 25
Bonci, T., Salis, F., Scott, K., Alcock, L., Becker, C., Bertuletti, S., Buckley, E. E., Caruso, M., Cereatti, A., Din, S. D., et al. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.868928 · Cited by 23
Arpan, I., Shah, V. V., McNames, J., Harker, G. R., Carlson‐Kuhta, P., Spain, R., El‐Gohary, M., Mancini, M., & Horak, F. B. (2022) · Sensors · doi:10.3390/s22165940 · Cited by 24
Self-citationFuzzy inference model evaluating turn for Parkinson’s disease patients
Ornelas-Vences, C., Fernández, L. P. S., Sánchez-Pérez, L. A., Garza-Rodríguez, A., & Villegas-Bastida, A. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.026 · Cited by 24
Ayachi, F. S., Nguyen, H., Goubault, É., Boissy, P., & Duval, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2519413 · Cited by 23
Mobility monitoring using smart technologies for Parkinson’s disease in free-living environment
Son, H., Park, W. S., & Kim, H. (2017) · Collegian Journal of the Royal College of Nursing Australia · doi:10.1016/j.colegn.2017.11.005 · Cited by 24
Shah, V. V., Jagodinsky, A. E., McNames, J., Carlson‐Kuhta, P., Nutt, J. G., El‐Gohary, M., Sowalsky, K. L., Harker, G. R., Mancini, M., & Horak, F. B. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1096401 · Cited by 23
Self-citationParrington, L., Jehu, D. A., Fino, P. C., Pearson, S., El‐Gohary, M., & King, L. A. (2018) · Sensors · doi:10.3390/s18124501 · Cited by 23
Self-citationConi, A., Ancum, J. M. V., Bergquist, R., Mikolaizak, A. S., Mellone, S., Chiari, L., Maier, A. B., & Pijnappels, M. A. G. M. (2019) · Sensors · doi:10.3390/s19030449 · Cited by 23
Self-citationSalvi, S., Garg, L., & Gurupur, V. P. (2025) · Sensors · doi:10.3390/s25175252 · Cited by 24
González-Alonso, J., Oviedo-Pastor, D., Aguado, H. J., Pernas, F. J. D., González‐Ortega, D., & Martínez‐Zarzuela, M. (2021) · Sensors · doi:10.3390/s21196642 · Cited by 22
Cockx, H. M., Nonnekes, J. H., Bloem, B. R., Wezel, R. J. A. V., Cameron, I. G. M., & Wang, Y. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01175-y · Cited by 21
Mancini, M., Curtze, C., Stuart, S., El‐Gohary, M., McNames, J., Nutt, J. G., & Horak, F. B. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512910 · Cited by 20
Self-citationFino, P. C., Weightman, M. M., Dibble, L. E., Lester, M., Hoppes, C. W., Parrington, L., Arango, J. I., Souvignier, A. R., Roberts, H. J., & King, L. A. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2020.544812 · Cited by 21
180° turn while walking: characterization and comparisons between subjects with and without stroke
Faria, C. D. C. D. M., Carvalho-Pinto, B. P. D. B., Nadeau, S. M., & Teixeira‐Salmela, L. F. (2016) · Journal of Physical Therapy Science · doi:10.1589/jpts.28.2694 · Cited by 20
Inertial Sensor Algorithms to Characterize Turning in Neurological Patients With Turn Hesitations
Shah, V. V., Curtze, C., Mancini, M., Carlson‐Kuhta, P., Nutt, J. G., Gomez, C. M., El‐Gohary, M., Horak, F. B., & McNames, J. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3037820 · Cited by 20
Self-citationShould we use both clinical and mobility measures to identify fallers in Parkinson's disease?
Vitório, R. R., Mancini, M., Carlson‐Kuhta, P., Horak, F. B., & Shah, V. V. (2022) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2022.105235 · Cited by 19
Self-citationFreezing of Gait in Parkinson’s Disease: Implications for Dual-Task Walking
Monaghan, A. S., Ragothaman, A., Harker, G. R., Carlson‐Kuhta, P., Horak, F. B., & Peterson, D. S. (2023) · Journal of Parkinson s Disease · doi:10.3233/jpd-230063 · Cited by 19
Self-citationSalkovic, D., Hobert, M. A., Bellut, C. D., Funer, F., Renno, S., Haertner, L., Hasmann, S. E., Staebler, J., Geritz, J., Suenkel, U., et al. (2017) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2017.00075 · Cited by 19
Bongartz, M., Kiss, R., Lacroix, A., Eckert, T., Ullrich, P., Jansen, C.-P., Feißt, M., Mellone, S., Chiari, L., Becker, C., et al. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab42d3 · Cited by 18
Self-citationEnsink, C. J., Smulders, K., Warnar, J., & Keijsers, N. (2023) · PeerJ · doi:10.7717/peerj.16641 · Cited by 18
Mentis, H. M., Shewbridge, R., Powell, S., Armstrong, M. J., Fishman, P., & Shulman, L. M. (2015) · Human-Computer Interaction · doi:10.1080/07370024.2015.1073592 · Cited by 19
Lebel, K., Nguyen, H., Duval, C., Plamondon, R., & Boissy, P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00051 · Cited by 18
Quantifying performance on an outdoor agility drill using foot-mounted inertial measurement units
Zaferiou, A. M., Ojeda, L., Cain, S. M., Vitali, R. V., Davidson, S. P., Stirling, L., & Perkins, N. C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188184 · Cited by 18
Kinematic but not clinical measures predict falls in Parkinson-related orthostatic hypotension
Sturchio, A., Dwivedi, A. K., Marsili, L., Hadley, A. J., Sobrero, G., Heldman, D. A., Maule, S. V., Lopiano, L., Comi, C., Versino, M., et al. (2020) · Journal of Neurology · doi:10.1007/s00415-020-10240-8 · Cited by 18
Zolfaghari, S., Suravee, S., Riboni, D., & Yordanova, K. (2023) · ACM Computing Surveys · doi:10.1145/3603495 · Cited by 19
The Instrumented Stand and Walk (ISAW) test to predict falls in older men
Horak, F. B., Laird, A. E., Carlson‐Kuhta, P., Abrahamson, M., Mancini, M., ORWOLL, E. S., Lapidus, J., & Shah, V. V. (2022) · GeroScience · doi:10.1007/s11357-022-00675-4 · Cited by 16
Self-citationMancini, M., Hasegawa, N., Peterson, D. S., Horak, F. B., & Nutt, J. G. (2023) · Journal of Neurology · doi:10.1007/s00415-023-11773-4 · Cited by 16
Self-citationKim, K., Zabihi, H., Kim, H., & Lee, U. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3131893 · Cited by 16
Turning difficulties after stroke and its relationship with trunk function
LIANG, P.-J., Chiu, V. J.-Y., Yann-Cherng, T. E. N. G., Huei-Ling, C. H. I. U., & Shu-Chun, L. E. E. (2021) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.21.06841-6 · Cited by 16
Understanding how people with Parkinson's disease turn in gait from a real-world in-home dataset
Morgan, C., Jameson, J., Craddock, I. J., Tonkin, E. L., Oikonomou, G., Isotalus, H., Heidarivincheh, F., McConville, R., Tourte, G. J. L., Kinnunen, K. M., et al. (2022) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2022.11.007 · Cited by 15
Experimental Protocol to Assess Neuromuscular Plasticity Induced by an Exoskeleton Training Session
Marco, R. D., Rubega, M., Lennon, O. C., Formaggio, E., Sutaj, N., Dazzi, G., Venturin, C., Bonini, I., Ortner, R., Bazo, H. A. C., et al. (2021) · Methods and Protocols · doi:10.3390/mps4030048 · Cited by 15
Mentis, H. M., Shewbridge, R., Powell, S., Fishman, P., & Shulman, L. M. (2015) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702342 · Cited by 15
Associations between Turning Characteristics and Corticospinal Inhibition in Young and Older Adults
Swanson, C. W., & Fling, B. W. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2019.10.051 · Cited by 14
Cheng, W.-Y., Lipsmeier, F., Scotland, A., Creagh, A., Kilchenmann, T., Jin, L., Schjodt-Eriksen, J., Wolf, D., Zhang-Schaerer, Y.-P., Garcia, I. F., et al. (2017) · 2017 IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268169 · Cited by 13
Trojaniello, D., Cereatti, A., Ravaschio, A., Bandettini, M. P., & Croce, U. D. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944132 · Cited by 13
Inertial and time-of-arrival ranging sensor fusion
Vasilyev, P., Pearson, S., El‐Gohary, M., Aboy, M., & McNames, J. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.011 · Cited by 13
Self-citationGait Parameters Estimated Using Inertial Measurement Units
Croce, U. D., Cereatti, A., & Mancini, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-30808-1_163-1 · Cited by 12
Self-citationAnticipatory detection of turning in humans for intuitive control of robotic mobility assistance
Farkhatdinov, I., Roehri, N., & Burdet, E. (2017) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aa80ad · Cited by 12
Shah, V. V., McNames, J., Carlson‐Kuhta, P., Nutt, J. G., El‐Gohary, M., Sowalsky, K. L., Mancini, M., & Horak, F. B. (2022) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.13601 · Cited by 12
Self-citationTemporal-Spatial Values During a 180° Step Turn in People with Unilateral Lower Limb Amputation
Clemens, S. M., Klute, G. K., Kirk-Sanchez, N. J., Raya, M. A., Kim, K. J., GAUNAURD, I. A., & GAILEY, R. S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.05.016 · Cited by 12
Chen, I.-H., Liang, P.-J., Chiu, V. J.-Y., & Lee, S. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.769975 · Cited by 12
Combination of Clinical and Gait Measures to Classify Fallers and Non-Fallers in Parkinson’s Disease
Araújo, H. A. G. D. O., Smaili, S. M., Morris, R., Graham, L., Das, J., McDonald, C., Walker, R. W., Stuart, S., & Vitório, R. R. (2023) · Sensors · doi:10.3390/s23104651 · Cited by 11
Rovini, E., Fiorini, L., Esposito, D., Maremmani, C., & Cavallo, F. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779543 · Cited by 11
Visual Cues for Turning in Parkinson’s Disease
Das, J., Vitório, R. R., Butterfield, A., Morris, R., Graham, L., Barry, G., McDonald, C., Walker, R. W., Mancini, M., & Stuart, S. (2022) · Sensors · doi:10.3390/s22186746 · Cited by 11
Self-citationMincolelli, G., Marchi, M., Chiari, L., Costanzo, A., Borelli, E., Mellone, S., Masotti, D., Paolini, G., & Imbesi, S. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-94622-1_31 · Cited by 11
Self-citationFang, X., & Jiang, Z. (2020) · PeerJ · doi:10.7717/peerj.9329 · Cited by 11
Automated Analysis of the Two-Minute Walk Test in Clinical Practice Using Accelerometer Data
Trentzsch, K., Melzer, B., Stölzer-Hutsch, H., Haase, R., Bartscht, P., Meyer, P. D., & Ziemssen, T. (2021) · Brain Sciences · doi:10.3390/brainsci11111507 · Cited by 11
Real-World Balance Assessment While Standing for Fall Prediction in Older Adults
Sanabria, J. L. A., Palumbo, P., Helbostad, J. L., Bandinelli, S., Mellone, S., Palmerini, L., & Chiari, L. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3326306 · Cited by 10
Self-citationGodi, M., Giardini, M., Nardone, A., Turcato, A. M., Caligari, M., Pisano, F., & Schieppati, M. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00053 · Cited by 10
Winters‐Stone, K. M., Krasnow, S. M., Horak, F. B., Mancini, M., Cameron, M. H., Dieckmann, N. F., Stoyles, S. A., & Roeland, E. J. (2023) · BMC Cancer · doi:10.1186/s12885-023-11546-2 · Cited by 9
Self-citationAlroumi, A. M., Hoppes, C. W., Whitney, S. L., Li, Z., Holt, L. S., Ramakrishnan, S., Barnicott, S. L., Logeais, M. T., Richard, H., Salter, S. R., et al. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1558795 · Cited by 14
Schuch, C. P., Balbinot, G. C., Bonilla, M. N., Machado, A. G., & de Oliveira, A. A. (2020) · Frontiers in Virtual Reality · doi:10.3389/frvir.2020.00007 · Cited by 11
Shah, V. V., McNames, J., Harker, G. R., Curtze, C., Carlson‐Kuhta, P., Spain, R., El‐Gohary, M., Mancini, M., & Horak, F. B. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.11.024 · Cited by 9
Self-citationAssociation Between Turning Mobility and Cognitive Function in Chronic Poststroke
Kuan, Y., Lin, L., Wang, C.-Y., Hu, C.-C., Liang, P.-J., & Lee, S. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.772377 · Cited by 9
Swanson, C. W., & Fling, B. W. (2023) · Sensors · doi:10.3390/s23177629 · Cited by 9
Quantifying Turning Tasks With Wearable Sensors: A Reliability Assessment
Weston, A. R., Antonellis, P., Fino, P. C., Hoppes, C. W., Lester, M., Weightman, M. M., Dibble, L. E., & King, L. A. (2023) · Physical Therapy · doi:10.1093/ptj/pzad134 · Cited by 9
Template-DTW based on inertial signals: Preliminary results for step characterization
Mantilla, J. J., Oudre, L., Barrois, R., Vienne, A., & Ricard, D. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037307 · Cited by 9
Powell, D., Nouredanesh, M., Stuart, S., & Godfrey, A. (2021) · Smart Health · doi:10.1016/j.smhl.2021.100220 · Cited by 9
Paschen, S., Hansen, C., Welzel, J., Albrecht, J., Atrsaei, A., Aminian, K., Zeuner, K. E., Romijnders, R., Warmerdam, E., Urban, P., et al. (2022) · Journal of Parkinson s Disease · doi:10.3233/jpd-223406 · Cited by 9
TAMURA, T. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_8 · Cited by 9
Sozzi, S., & Schieppati, M. (2016) · Neural Plasticity · doi:10.1155/2016/7123609 · Cited by 8
Large-Scale Continuous Mobility Monitoring of Parkinson’s Disease Patients Using Smartphones
Cheng, W., Lipsmeier, F., Creigh, A., Scotland, A., Kilchenmann, T., Jin, L., Schjodt‐Eriksen, J., Wolf, D., Zhang, Y., Garcia, I. F., et al. (2018) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-319-98551-0_2 · Cited by 8
King, L. A., Carlson‐Kuhta, P., Wilhelm, J., Lapidus, J., Dale, M., Talman, L., Barlow, N., Mancini, M., & Horák, F. (2022) · BMC Neurology · doi:10.1186/s12883-022-02934-5 · Cited by 8
Self-citationLebel, K., Duval, C., Nguyen, H., Plamondon, R., & Boissy, P. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00022 · Cited by 7
Free-living gait does not differentiate chronic mTBI patients compared to healthy controls
Powell, D., Godfrey, A., Parrington, L., Campbell, K. R., King, L. A., & Stuart, S. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01030-6 · Cited by 7
Marco, R. D., Rubega, M., Lennon, O. C., Vianello, A., Masiero, S., Formaggio, E., & Felice, A. D. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3273819 · Cited by 7
Design of a Multi-Sensors Wearable System for Continuous Home Monitoring of People With Parkinson’s
Sica, M., Varnosfaderani, O. T., Crowe, C., Kenny, L., Bocchino, A., O’Flynn, B., Mueller, D. S., Tedesco, S. A., Timmons, S., & Barton, J. J. (2024) · IEEE Access · doi:10.1109/access.2024.3375871 · Cited by 8
Real-world gait and turning in individuals scheduled for total knee arthroplasty
Boekesteijn, R. J., Keijsers, N., Defoort, K. C., Mancini, M., Bruning, F., El‐Gohary, M., Geurts, A. C. H., & Smulders, K. (2024) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2024.106332 · Cited by 7
Self-citationWearables in rugby union: A protocol for multimodal digital sports-related concussion assessment
Powell, D., Stuart, S., & Godfrey, A. (2021) · PLoS ONE · doi:10.1371/journal.pone.0261616 · Cited by 7
Gait Parameters Estimated Using Inertial Measurement Units
Croce, U. D., Cereatti, A., & Mancini, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-14418-4_163 · Cited by 7
Self-citationScattolini, M., Tigrini, A., Verdini, F., Burattini, L., Fioretti, S., & Mengarelli, A. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3567833 · Cited by 6
O'Hara, K. P., Morrison, C. P., Sellen, A. J., Bianchi‐Berthouze, N., & Craig, C. (2016) · Synthesis lectures on assistive, rehabilitative, and health-preserving technologies · doi:10.2200/s00702ed1v01y201602arh009 · Cited by 6
Lee, C. J., & Lee, J. K. (2022) · Sensors · doi:10.3390/s22062149 · Cited by 6
O'Hara, K. P., Morrison, C. P., Sellen, A. J., Bianchi‐Berthouze, N., & Craig, C. (2016) · Synthesis lectures on assistive, rehabilitative, and health-preserving technologies · doi:10.1007/978-3-031-01600-4 · Cited by 6
Slower Reorientation of Trunk for Reactive Turning while Walking in Hemiparesis Stroke Patients
Nakamura, T., Higuchi, T., Kikumoto, T., Takeda, T., Tashiro, H., & Hoshi, F. (2019) · Journal of Motor Behavior · doi:10.1080/00222895.2018.1547894 · Cited by 6
Betteridge, C., Natarajan, P., Fonseka, R. D., Ho, D., Mobbs, R. J., & Choy, W. J. (2021) · mHealth · doi:10.21037/mhealth-21-7 · Cited by 6
Between-site equivalence of turning speed assessments using inertial measurement units
Parrington, L., King, L. A., Weightman, M. M., Hoppes, C. W., Lester, M., Dibble, L. E., & Fino, P. C. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.09.164 · Cited by 6
Towards ecologically valid biomarkers: real-life gait assessment in cerebellar ataxiaPreprint
Ilg, W., Seemann, J., Giese, M. A., Traschütz, A., Schöls, L. J., Timmann, D., & Synofzik, M. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/802918 · Cited by 6
Bertoli, M., Cereatti, A., Croce, U. D., & Mancini, M. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325122 · Cited by 5
Self-citationBeyond timing and step counting in 360° turning-in-place assessment: a scoping review
Neťuková, S., Horáková, L., Szabo, Z., & Krupička, R. (2024) · BioMedical Engineering OnLine · doi:10.1186/s12938-024-01208-0 · Cited by 5
The identification of multiple U-turns in gait: comparison of four trunk IMU-based methods
Bertoli, M., Cereatti, A., Trojaniello, D., Ravaschio, A., & Croce, U. D. (2017) · International Conference on Body Area Networks · doi:10.4108/eai.15-12-2016.2267650 · Cited by 5
A Novel Martingale Based Model Using a Smartphone to Detect Gait Bout in Human Activity Recognition
Etumusei, J., Carracedo, J. M., & McClean, S. I. (2022) · Journal of Sensors · doi:10.1155/2022/4753732 · Cited by 6
Monitoring Mobility at Home: The GAIT-HUB Sensor-Based Protocol for Remote Gait Analysis
Pilloni, G., Ko, T., Kreisberg, E., Geel, J., Gutman, J. M., Sammarco, C. L., Oh, C., & Charvet, L. E. (2025) · Digital Biomarkers · doi:10.1159/000547176 · Cited by 4
Continuous Monitoring of Head Turns: Compliance, Kinematics, and Reliability of Wearable Sensing
Cho, S. Y., Dibble, L. E., & Fino, P. C. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3622072 · Cited by 4
Real-world gait study of Parkinson’s disease using wearable sensors: a systematic review
Michaud, M., de l′Escalopier, N., Voisard, C., Oudre, L., & Ricard, D. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-01957-0 · Cited by 5
Turning assessment for discrimination of frailty syndrome among community-dwelling older adults
Chiu, H., Tsai, C.-Y., Liu, Y.-L., Kang, C.-W., & Lee, S. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.04.004 · Cited by 4
Mylius, V., Maes, L., Negele, K., Schmid, C., Sylvester, R., Brook, C. S., Brugger, F., Perez‐Lloret, S., Bansi, J., Aminian, K., et al. (2022) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2021.774658 · Cited by 4
Review on Conventional Approaches to Balance Assessment
Hanim, N., Khor, Y. Y. W., Khor, K. X., Abdullah, M. N., Yeong, C. F., & Su, E. L. M. (2023) · Journal of Human Centered Technology · doi:10.11113/humentech.v2n2.56 · Cited by 4
Miller, K. T., Russell, M., Jenks, T., Surratt, K., Poretti, K., Eigenbrot, S., Akins, J. S., & Major, M. J. (2020) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000332 · Cited by 4
Abel, B., Bongartz, M., Eckert, T., Ullrich, P., Beurskens, R., Mellone, S., Bauer, J. M., Lamb, S. E., & Hauer, K. A. (2020) · Sensors · doi:10.3390/s20247208 · Cited by 4
Self-citationKinematic Relations during Double Support Phase in Parkinsonian Gait
Sitek, O., Kalichová, M., Hedbávný, P., Boušek, T., & Baláž, M. (2022) · Applied Sciences · doi:10.3390/app12030949 · Cited by 4
Suitability of a Low-Cost Wearable Sensor to Assess Turning in Healthy Adults
Mason, R., Byerley, J., Baker, A., Powell, D., Pearson, L. T., Barry, G., Godfrey, A., Mancini, M., Stuart, S., & Morris, R. (2022) · Sensors · doi:10.3390/s22239322 · Cited by 4
Self-citationBertoli, M., Cereatti, A., Croce, U. D., Pica, A., & Bini, F. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438723 · Cited by 4
Lee, C. J., & Lee, J. K. (2021) · Journal of the Korean Society for Precision Engineering · doi:10.7736/jkspe.020.108 · Cited by 4
Application of the ActiGraph GT9X IMU for the assessment of turning during walking and running
Marcotte, R. T., Bassett, D. R., Weinhandl, J. T., & Crouter, S. E. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aad0d0 · Cited by 4
Your turn: At home turning angle estimation for Parkinson’s disease severity assessment
Cheng, Q., Morgan, C., Sikdar, A., Masullo, A., Whone, A. L., & Mirmehdi, M. (2025) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2025.103194 · Cited by 4
Effect of fear of falling on turning performance among patients with chronic stroke
Chen, I.-H., Lin, L., Lin, C., Wang, C.-Y., Hu, C.-C., & Lee, S. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.06.006 · Cited by 3
A study of turn bias in people with idiopathic Parkinson’s disease
Pillai, L., Glover, A., & Virmani, T. (2022) · Experimental Brain Research · doi:10.1007/s00221-022-06378-8 · Cited by 3
The Influence of Stride Selection on Gait Parameters Collected with Inertial Sensors
Ensink, C. J., Smulders, K., Warnar, J., & Keijsers, N. (2023) · Sensors · doi:10.3390/s23042002 · Cited by 3
Metadata
- Authors
- El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L.
- Affiliations
- APDM, Inc., Portland, OR 97201, USA
- APDM (United States) (US)
- Oregon Health & Science University (US)
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-12-27
- Volume
- 14
- Issue
- 1
- Pages
- 356-369
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC3926561
- OpenAlex
- W2067428313
- Cited by
- 258
- References
- 33
- Citations by year
- 2026: 17 · 2025: 20 · 2024: 16 · 2023: 21 · 2022: 26 · 2021: 27 · 2020: 25 · 2019: 28 · 2018: 23 · 2017: 29 · 2016: 16 · 2015: 5 · 2014: 5
- FWCI
- 22.53
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PDXScholar (Portland State University) (submittedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institute on Aging (R01AG006457)
- National Institute of Neurological Disorders and Stroke (R41NS076088)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Keywords
- turning, Parkinson's disease, mobility impairment, wearable inertial sensors, fall risk, freezing of gait, gait analysis, home monitoring, older adults, daily activities, turning angle, step count
- MeSH terms
- Aged, Algorithms, Female, Persons with Disabilities, Humans, Male, Middle Aged, Movement, Parkinson Disease, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review