The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications
Open accessAbstract
This article presents a review of the methods used in recognition and analysis of the human gait from three different approaches: image processing, floor sensors and sensors placed on the body. Progress in new technologies has led the development of a series of devices and techniques which allow for objective evaluation, making measurements more efficient and effective and providing specialists with reliable information. Firstly, an introduction of the key gait parameters and semi-subjective methods is presented. Secondly, technologies and studies on the different objective methods are reviewed. Finally, based on the latest research, the characteristics of each method are discussed. 40% of the reviewed articles published in late 2012 and 2013 were related to non-wearable systems, 37.5% presented inertial sensor-based systems, and the remaining 22.5% corresponded to other wearable systems. An increasing number of research works demonstrate that various parameters such as precision, conformability, usability or transportability have indicated that the portable systems based on body sensors are promising methods for gait analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance‐Oriented Assessment of Mobility Problems in Elderly Patients
Tinetti, M. E. (1986) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1986.tb05480.x · Cited by 3,352
Individual recognition using gait energy image
Han, J., & Bhanu, B. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.38 · Cited by 1,847
Balance in elderly patients: the "get-up and go" test.
Mathias, S., Nayak, U. S., & Isaacs, B. (1986) · PubMed · Cited by 1,543
Silhouette analysis-based gait recognition for human identification
Wang, L., Tan, T., Ning, H., & Hu, W. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1251144 · Cited by 1,202
Development of a multiple sclerosis functional composite as a clinical trial outcome measure
Cutter, G. R. (1999) · Brain · doi:10.1093/brain/122.5.871 · Cited by 1,190
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Measuring the impact of MS on walking ability: The 12-Item MS Walking Scale (MSWS-12)
Hobart, J. C., Riazi, A., Lamping, D. L., Fitzpatrick, R., & Thompson, A. J. (2003) · Neurology · doi:10.1212/wnl.60.1.31 · Cited by 821
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
Handbook of pattern recognition and image processing
(1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(86)90086-1 · Cited by 763
Afilalo, J., Eisenberg, M. J., Morin, J.-F., Bergman, H., Monette, J., Noiseux, N., Perrault, L. P., Alexander, K. P., Langlois, Y., Dendukuri, N., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.039 · Cited by 746
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Kerrigan, D. C., Todd, M. K., Della Croce, U., Lipsitz, L. A., & Collins, J. J. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90013-2 · Cited by 636
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
Full body gait analysis with Kinect
Gabel, M., Gilad-Bachrach, R., Renshaw, E., & Schuster, A. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346340 · Cited by 331
Gait Pattern in the Early Recovery Period after Stroke*
KRAMERS DE QUERVAIN, I. A., SIMON, S. R., LEURGANS, S., PEASE, W. S., & McALLISTER, D. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199610000-00008 · Cited by 316
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314
The evolution of clinical gait analysis
Sutherland, D. H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00004-8 · Cited by 314
Gait Assessment in the Elderly: A Gait Abnormality Rating Scale and Its Relation to Falls
Wolfson, L., Whipple, R., Amerman, P., & Tobin, J. N. (1990) · Journal of Gerontology · doi:10.1093/geronj/45.1.m12 · Cited by 285
Concurrent neuromechanical and functional gains following upper-extremity power training post-stroke
Patten, C., Condliffe, E. G., Dairaghi, C. A., & Lum, P. S. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-1 · Cited by 259
Objective biomarkers of balance and gait for Parkinson's disease using body‐worn sensors
Horak, F. B., & Mancini, M. (2013) · Movement Disorders · doi:10.1002/mds.25684 · Cited by 255
The evolution of clinical gait analysis part l: kinesiological EMG
Sutherland, D. H. (2001) · Gait & Posture · doi:10.1016/s0966-6362(01)00100-x · Cited by 253
Di Stasi, S. L., Logerstedt, D., Gardinier, E. S., & Snyder-Mackler, L. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513482718 · Cited by 240
Lawton, G. (2006) · The New Scientist · Cited by 234
Motion Mode Recognition and Step Detection Algorithms for Mobile Phone Users
Susi, M., Renaudin, V., & Lachapelle, G. (2013) · Sensors · doi:10.3390/s130201539 · Cited by 231
A Floor Sensor System for Gait Recognition
Middleton, L., Buss, A. A., Bazin, A., & Nixon, M. S. (2006) · Fourth IEEE Workshop on Automatic Identification Advanced Technologies (AutoID'05) · doi:10.1109/autoid.2005.2 · Cited by 227
Typical features of cerebellar ataxic gait
Stolze, H. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.73.3.310 · Cited by 208
Kinetic Gait Analysis Using a Low-Cost Insole
Howell, A. M., Kobayashi, T., Hayes, H. A., Foreman, K. B., & Bamberg, S. J. M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2250972 · Cited by 207
Inertial Sensor-Based Methods in Walking Speed Estimation: A Systematic Review
Yang, S., & Li, Q. (2012) · Sensors · doi:10.3390/s120506102 · Cited by 204
Multichannel SEMG in clinical gait analysis: A review and state-of-the-art
Frigo, C., & Crenna, P. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.07.012 · Cited by 193
Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
Clark, R. A., Pua, Y.-H., Bryant, A. L., & Hunt, M. A. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.03.029 · Cited by 178
Use of pressure insoles to calculate the complete ground reaction forces
Forner Cordero, A., Koopman, H. J. F. M., & van der Helm, F. C. T. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.016 · Cited by 177
Jahn, K., Zwergal, A., & Schniepp, R. (2010) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2010.0306 · Cited by 173
Time-of-Flight Sensors in Computer Graphics
Kolb, A., Barth, E., Koch, R., & Larsen, R. (2009) · Eurographics · doi:10.2312/egst.20091064 · Cited by 164
Support vector regression for multi-view gait recognition based on local motion feature selection
Kusakunniran, W., Wu, Q., Zhang, J., & Li, H. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5540113 · Cited by 163
Infrared gait recognition based on wavelet transform and support vector machine
Xue, Z., Ming, D., Song, W. G., Wan, B., & Jin, S. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.03.011 · Cited by 160
Improved Cycle Detection for Accelerometer Based Gait Authentication
Derawi, M. O., Bours, P., & Holien, K. (2010) · 2010 Sixth International Conference on Intelligent Information Hiding and Multimedia Signal Processing · doi:10.1109/iihmsp.2010.84 · Cited by 159
The evolution of clinical gait analysis part III – kinetics and energy assessment
Sutherland, D. H. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.07.008 · Cited by 136
Osteoporosis and gait and balance disturbances in older sarcopenic obese New Zealanders
Waters, D. L., Hale, L. A., Grant, A. M., Herbison, P., & Goulding, A. (2009) · Osteoporosis International · doi:10.1007/s00198-009-0947-5 · Cited by 122
Comparative Analysis and Fusion of Spatiotemporal Information for Footstep Recognition
Vera-Rodríguez, R., Mason, J. S. D., Fiérrez, J., & Ortega-García, J. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.164 · Cited by 119
Lee, H., Sullivan, S. J., & Schneiders, A. G. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.03.013 · Cited by 116
Automated detection of gait initiation and termination using wearable sensors
Novak, D., Reberšek, P., Rossi, S., Donati, M., Podobnik, J., Beravs, T., Lenzi, T., Vitiello, N., Carrozza, M. C., & Munih, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.07.003 · Cited by 116
Savelberg, H. H. C. M., & Lange, A. L. H. D. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00036-4 · Cited by 114
A Novel Approach to Reducing Number of Sensing Units for Wearable Gait Analysis Systems
Salarian, A., Burkhard, P. R., Vingerhoets, F. J. G., Jolles, B. M., & Aminian, K. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2223465 · Cited by 100
Gehlsen, G. M., Beekman, K., Assmann, N., Winant, D. M., Seidle, M. E., & Carter, A. (1986) · PubMed · Cited by 94
Locomotion Mode Classification Using a Wearable Capacitive Sensing System
Chen, B., Zheng, E., Fan, X., Liang, T., Wang, Q., Wei, K., & Wang, L. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2262952 · Cited by 94
Detection of the onset of gait initiation using kinematic sensors and EMG in transfemoral amputees
Wentink, E. C., Schut, V. G. H., Prinsen, E. C., Rietman, J. S., & Veltink, P. H. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.08.008 · Cited by 92
Quantifying Dynamic Characteristics of Human Walking for Comprehensive Gait Cycle
Mummolo, C., Mangialardi, L., & Kim, J. H. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4024755 · Cited by 87
Inter-laboratory consistency of gait analysis measurements
Benedetti, M. G., Merlo, A., & Leardini, A. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.04.022 · Cited by 79
Emerging Trends of Body-Mounted Sensors in Sports and Human Gait Analysis
Gouwanda, D., & Senanayake, S. M. N. A. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6_178 · Cited by 76
Bae, J., & Tomizuka, M. (2013) · Mechatronics · doi:10.1016/j.mechatronics.2013.06.007 · Cited by 71
Talking the talk on walking the walk
Holland, A., O’Connor, R. J., Thompson, A. J., Playford, E. D., & Hobart, J. C. (2006) · Journal of Neurology · doi:10.1007/s00415-006-0272-2 · Cited by 63
Converging Clinical and Engineering Research on Neurorehabilitation
Pons, J. L., Torricelli, D., & Pajaro-Blázquez, M. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-34546-3 · Cited by 62
Predicting muscle forces in gait from EMG signals and musculotendon kinematics
White, S. C., & Winter, D. A. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90025-e · Cited by 58
Your Floor Knows Where You Are: Sensing and Acquisition of Movement Data
Leusmann, P., Möllering, C., Klack, L., Kasugai, K., Ziefle, M., & Rumpe⋆, B. (2011) · IEEE International Conference on Mobile Data Management (MDM) · doi:10.1109/mdm.2011.29 · Cited by 51
Imaging gait disorders in parkinsonism: a review
Maillet, A., Pollak, P., & Debû, B. (2012) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2012-302461 · Cited by 51
A Digital Goniometer based on encoders for measuring knee-joint position in an orthosis
Domínguez, G., Cardiel, E., Arias, S., & Rogeli, P. (2013) · World Congress on Nature and Biologically Inspired Computing (NaBIC) · doi:10.1109/nabic.2013.6617835 · Cited by 40
Fried, A. V., Cwikel, J., Ring, H., & Galinsky, D. (1990) · International Disability Studies · doi:10.3109/03790799009166609 · Cited by 38
Arbitrary view transformation model for gait person authentication
Muramatsu, D., Shiraishi, A., Makihara, Y., & Yagi, Y. (2012) · IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2012.6374561 · Cited by 33
Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors: In-Lab and In-Situ Evaluation
Sant’Anna, A., Wickström, N., Eklund, H., Zügner, R., & Tranberg, R. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-38256-7_16 · Cited by 27
The Use of Dynamic and Static Characteristics of Gait for Individual Identification
Pratheepan, Y., Condell, J. V., & Prasad, G. (2009) · International Machine Vision and Image Processing Conference (IMVIP) · doi:10.1109/imvip.2009.27 · Cited by 27
Gait recognition using time-of-flight sensor
Derawi, M. O., Ali, H., & Cheikh, F. A. (2011) · NORA - Norwegian Open Research Archives · Cited by 27
Real-time gait monitoring for Parkinson Disease
Tay, A. E., Yen, S., Li, J. Z., Lee, W. W., Yogaprakash, K., Chung, C. L. H., Liew, S. G., David, B., & Au, W. (2013) · International Conference on Control and Automation · doi:10.1109/icca.2013.6565196 · Cited by 15
An Overview of Gait Analysis and Step Detection in Mobile Computing Devices
McGuire, M. L. (2012) · International Conference on Intelligent Networking and Collaborative Systems (INCoS) · doi:10.1109/incos.2012.110 · Cited by 14
Ba, R. P., Piérard, S. L., Moonen, G., Droogenbroeck, M. V., & Belachew, S. M. (2012) · Multiple Sclerosis Journal · Cited by 10
An Overview of Wearable Sensing and Wearable Feedback for Gait Retraining
Shull, P. B., Jirattigalachote, W., & Zhu, X. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40852-6_44 · Cited by 10
Toward the Use of Wearable Inertial Sensors to Train Gait in Subjects with Movement Disorders
Ferrari, A., Rocchi, L., van den Noort, J. C., & Harlaar, J. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-34546-3_152 · Cited by 10
Human gait recognition based on motion analysis including ankle to foot angle measurement
Fathima, S. M. H. S. S., & Banu, R. (2012) · International Conference on Computing, Electronics and Electrical Technologies · doi:10.1109/icceet.2012.6203856 · Cited by 7
Calculation of joint reaction force and joint moments using by wearable walking analysis system
Adachi, W., TSUJIUCHI, N., KOIZUMI, T., et al. (2012) · doi:10.1109/embc.2012.6345979 · Cited by 4
Cited by
Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0084-2 · Cited by 476
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
Inertial Sensor-Based Gait Recognition: A Review
Sprager, S., & Juric, M. (2015) · Sensors · doi:10.3390/s150922089 · Cited by 347
Metadata
- Authors
- Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-02-19
- Volume
- 14
- Issue
- 2
- Pages
- 3362-3394
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1970493599
- Cited by
- 1,172
- References
- 69
- FWCI
- 29.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.