The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit
Open accessAbstract
Quantitative assessment of parkinsonian tremor based on inertial sensors can provide reliable feedback on the effect of medication. In this regard, the features of parkinsonian tremor and its unique properties such as motor fluctuations and dyskinesia are taken into account. Least-square-estimation models are used to assess the severities of rest, postural, and action tremors. In addition, a time-frequency signal analysis algorithm for tremor state detection was also included in the tremor assessment method. This inertial sensor-based method was verified through comparison with an electromagnetic motion tracking system. Seven Parkinson’s disease (PD) patients were tested using this tremor assessment system. The measured tremor amplitudes correlated well with the judgments of a neurologist (r = 0.98). The systematic analysis of sensor-based tremor quantification and the corresponding experiments could be of great help in monitoring the severity of parkinsonian tremor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“The action tremor (kinetic tremor) happens when a voluntary contraction of a muscle follows a certain action—for example, holding a cup [6].”
BackgroundMonitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“The occurrence and amplitude of parkinsonian tremor are influenced by such effects [10,11].”
BackgroundSalarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Dynamics of tremor-related oscillations in the human globus pallidus: a single case study
Hurtado, J. M., Gray, C. M., Tamas, L. B., & Sigvardt, K. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.4.1674 · Cited by 246
Pathological tremors: deterministic chaos or nonlinear stochastic oscillators?
Timmer, J., Häussler, S., Lauk, M., & Lücking, C.-H. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166494 · Cited by 130
Estimation of physiological tremor from accelerometers for real-time applications
Veluvolu, K. C., & Ang, W. T. (2011) · Sensors · doi:10.3390/s110303020 · Cited by 117 · cited 1×
“Tremor Quantification has been performed by signal processing methods such as time-domain analysis, time-frequency analysis, spectral analysis, and nonlinear analysis [31,32].”
MethodCharacteristics of hand tremor time series
Timmer, J., Gantert, C., Deuschl, G., & Honerkamp, J. (1993) · Biological Cybernetics · doi:10.1007/bf00202568 · Cited by 112
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83
Adaptive band-pass filter (ABPF) for tremor extraction from inertial sensor data
Popović, L. Z., Šekara, T. B., & Popović, M. B. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.03.018 · Cited by 29
Cited by
Steven Eyobu, O., & Han, D. S. (2018) · Sensors · doi:10.3390/s18092892 · Cited by 259
“In [24], a quantitative assessment of Parkinson’s tremor is conducted using least-square-estimation models.”
BackgroundMethodde Faria, S. M., de Morais Fabrício, D., Tumas, V., Castro, P. C., Ponti, M. A., Hallak, J. E., Zuardi, A. W., Crippa, J. A. S., & Chagas, M. H. N. (2020) · Journal of Psychopharmacology · doi:10.1177/0269881119895536 · Cited by 140
Kim, H. B., Lee, W. W., Kim, A., Lee, H. J., Park, H. Y., Jeon, H. S., Kim, S. K., Jeon, B., & Park, K. S. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.02.007 · Cited by 124
Using Portable Transducers to Measure Tremor Severity
Elble, R. J., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.320 · Cited by 95
Papadopoulos, A., Kyritsis, K., Klingelhoefer, L., Bostanjopoulou, S., Chaudhuri, K. R., & Delopoulos, A. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2961748 · Cited by 79
Metadata
- Authors
- Dai, H., Zhang, P., & Lueth, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2015-09-29
- Volume
- 15
- Issue
- 10
- Pages
- 25055-25071
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2104033295
- Cited by
- 159
- References
- 9
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit. https://app.cochat.ai/papers/10.3390/s151025055
- The paper
- Dai, H., Zhang, P., & Lueth, T. (2015). Quantitative Assessment of Parkinsonian Tremor Based on an Inertial Measurement Unit. Sensors. https://doi.org/10.3390/s151025055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.