The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Polymer Optical Fiber Sensors in Healthcare Applications: A Comprehensive Review
Open accessAbstract
Advances in medicine and improvements in life quality has led to an increase in the life expectancy of the general population. An ageing world population have placed demands on the use of assistive technology and, in particular, towards novel healthcare devices and sensors. Besides the electromagnetic field immunity, polymer optical fiber (POF) sensors have additional advantages due to their material features such as high flexibility, lower Young’s modulus (enabling high sensitivity for mechanical parameters), higher elastic limits, and impact resistance. Such advantages are well-aligned with the instrumentation requirements of many healthcare devices and in movement analysis. Aiming at these advantages, this review paper presents the state-of-the-art developments of POF sensors for healthcare applications. A plethora of healthcare applications are discussed, which include movement analysis, physiological parameters monitoring, instrumented insoles, as well as instrumentation of healthcare robotic devices such as exoskeletons, smart walkers, actuators, prostheses, and orthosis. This review paper shows the feasibility of using POF sensors in healthcare applications and, due to the aforementioned advantages, it is possible to envisage a further widespread use of such sensors in this research field in the next few years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Health monitoring in the home of the future
Korhonen, I., Parkka, J., & Van Gils, M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213628 · Cited by 486
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
Resting Heart Rate: Risk Indicator and Emerging Risk Factor in Cardiovascular Disease
Böhm, M., Reil, J.-C., Deedwania, P., Kim, J. B., & Borer, J. S. (2015) · The American Journal of Medicine · doi:10.1016/j.amjmed.2014.09.016 · Cited by 236
Highly flexible and stretchable optical strain sensing for human motion detection
Guo, J., Niu, M., & Yang, C. (2017) · Optica · doi:10.1364/optica.4.001285 · Cited by 220
eHealth integration and interoperability issues: Towards a solution through enterprise architecture
Adenuga, O. A., Kekwaletswe, R. M., & Coleman, A. (2015) · Health Information Science and Systems · doi:10.1186/s13755-015-0009-7 · Cited by 67
Cited by
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 377
Mbunge, E., Muchemwa, B., Jiyane, S., & Batani, J. (2021) · Global Health Journal · doi:10.1016/j.glohj.2021.11.008 · Cited by 348
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Metadata
- Authors
- Leal-Junior, A. G., Diaz, C. A. R., Avellar, L. M., Pontes, M. J., Marques, C., & Frizera, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-07-18
- Volume
- 19
- Issue
- 14
- Pages
- 3156
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2959799147
- Cited by
- 211
- References
- 7
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.