Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 Sample veins image from different wavelengths: (a) 850 nm [50] and (b) 696 nm [43].](https://figures.cochat.ai/paper-figures/ec160c930a31485bbb9f52bba331aa9d/vein-pattern-locating-technology-for-cannulation-a-review-of-the-low-cost-vein-figure-4.jpg)

![Figure 6 (a) Selecting a point from fused images to extract values of: (b) Depth and (c) thickness using the proposed imaging system [71].](https://figures.cochat.ai/paper-figures/38fc746242854d4f80d73ff2b8bb4574/vein-pattern-locating-technology-for-cannulation-a-review-of-the-low-cost-vein-figure-6.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“First-attempt success rates improved by 28% (RR 1.28, 95% CI 1.14–1.42, p < 0.001) [15,22,23], with a number needed to treat of 4.7.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The 42% relative improvement in first-attempt success [13,14,15] translates to substantially reduced patient discomfort, particularly important in vulnerable populations such as children and cancer patients who may require frequent blood sampling.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Fifteen studies encompassing 2468 patients [15,22,23] examined near-infrared visualization devices compared to traditional venipuncture.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Complication rates were significantly reduced (RR 0.41, 95% CI 0.33–0.52, p < 0.001) [13,15], primarily reflecting decreased hematoma formation and patient discomfort.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“First-attempt success rates showed a dramatic improvement with ultrasound guidance (RR 1.42, 95% CI 1.26–1.58, p < 0.001) [13,14,15], corresponding to a number needed to treat of 3.2 patients.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [15]
Experimental — accuracy not yet measured
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of Obesity Among Adults and Youth: United States, 2015-2016.
Hales, C. M., Carroll, M. D., Fryar, C. D., & Ogden, C. L. (2017) · PubMed · Cited by 3,884
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Hemoglobin Variants: Biochemical Properties and Clinical Correlates
Thom, C. S., Dickson, C. F., Gell, D. A., & Weiss, M. J. (2013) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a011858 · Cited by 336 · cited 1×
“As to its major function, it is able to transport oxygen (O2) rich blood (oxyhemoglobin) from the lungs to the peripheral tissues and carbon dioxide (CO2) rich blood (deoxyhemoglobin) with the opposite route [9].”
BackgroundRising Burden of Obesity in Asia
Ramachandran, A., & Snehalatha, C. (2010) · Journal of Obesity · doi:10.1155/2010/868573 · Cited by 301 · cited 4×
“More so, obesity levels have reached epidemic proportions in many Asian countries and many of them have rates which are not far from that in the USA [63] with the Centers for Disease Control and Prevention (CDC) report in 2015–2016, of the obesity prevalence in US of 39.8% in adults and 18.5% in youth [64].”
BackgroundInfluentialSebbane, M., Claret, P.-G., Lefebvre, S., Mercier, G., Rubenovitch, J., Jreige, R., Eledjam, J.-J., & de La Coussaye, J.-E. (2013) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2012.07.051 · Cited by 179 · cited 2×
“Moreover, cannulation is being used in performing technical procedures in emergency medicine [10].”
BackgroundMethodLippi, G., Banfi, G., Church, S., Cornes, M., De Carli, G., Grankvist, K., Kristensen, G. B., Ibarz, M., Panteghini, M., Plebani, M., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1051 · Cited by 151 · cited 1×
“The said processes are part of the pre-analytical phase [2].”
BackgroundA Review of Medical Errors in Laboratory Diagnostics and Where We Are Today: Table 1
Hammerling, J. A. (2012) · Laboratory Medicine · doi:10.1309/lm6er9wjr1ihqauy · Cited by 146
Blood venous sample collection: Recommendations overview and a checklist to improve quality
Giavarina, D., & Lippi, G. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.021 · Cited by 136 · cited 1×
“With these challenges, the integrity of the biological samples that should represent the biological status in vivo was affected leading to unreliable diagnostic information [3].”
BackgroundEvaluation of errors in a clinical laboratory: a one-year experience
Goswami, B., Singh, B. M., Chawla, R., & Mallika, V. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.006 · Cited by 121
Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117 · cited 2×
“Moreover, it was mentioned that the transilluminator (vein finder) can make for more accurate visualization of the vein course, unfortunately, it is not widely used mainly due to the cost of the commercially available devices [19].”
Background
Research works printed but not linked: 2
- Doshi, 2013, Non-invasive optical sensor for hemoglobin determination, Int. J. Eng. Res. Appl. (Ijera), 3, 559
- Crisan, S., Tarnovan, I., and Crisan, T. (2007, January 19–21). Vein Pattern Recognition. Image Enhancement and feature Extraction Algorithms. Proceedings of the 15th IMEKO TC4 Symposium on Novelties in Electrical Measurements and Instrumentation, Iaşi, Romania.
Cited by
He, X., Liu, Y., Ganesan, K., Ahnood, A., Beckett, P., Eftekhari, F., Smith, D., Uddin, M. H., Skafidas, E. S., Nirmalathas, A. T., et al. (2020) · APL Photonics · doi:10.1063/1.5140215 · Cited by 65
Francisco, M. D., Chen, W., Pan, C.-T., Lin, M., Wen, Z., Liao, C.-F., & Shiue, Y. (2021) · Micromachines · doi:10.3390/mi12040373 · Cited by 53
“These were the veins that were observed during the prototype testing with emphasis on the median cubital vein [9].”
MethodSelf-citationImplementation of Thermal Camera for Non-Contact Physiological Measurement: A Systematic Review
Manullang, M. C. T., Lin, Y., Lai, S.-J., & Chou, N. (2021) · Sensors · doi:10.3390/s21237777 · Cited by 67
“[24] 2019 Focused on vein finder by using near infrared (NIR)”
BackgroundHuang, W., Yoon, S., Wu, B., Lu, K., Lin, C.-M., Yang, H., & Liu, R. (2020) · Chemical Communications · doi:10.1039/d0cc03030a · Cited by 35
Bae, B., Park, M., Lee, D., Sim, I., & Lee, K. (2022) · Advanced Optical Materials · doi:10.1002/adom.202201905 · Cited by 35
Dorsal Hand Vein Image Enhancement Using Fusion of CLAHE and Fuzzy Adaptive Gamma
Yakno, M., Mohamad–Saleh, J., & Ibrahim, M. Z. (2021) · Sensors · doi:10.3390/s21196445 · Cited by 29
“Hence, the NIR concept has been adopted in research works for vein imaging [3–5].”
MethodNear Infrared Illumination Optimization for Vein Detection: Hardware and Software Approaches
Rahman, A. B. A., Juhim, F., Chee, F. P., Bade, A., & Kadir, F. B. M. (2022) · Applied Sciences · doi:10.3390/app122111173 · Cited by 33
“If there was uncertainty about whether the ROI was indeed a vein or a shadow, it was not included in the count.”
BackgroundMethodHyperspectral reconstruction from RGB images for vein visualization
Sharma, N., & Hefeeda, M. M. (2020) · ACM Multimedia Systems Conference (MMSys) · doi:10.1145/3339825.3391861 · Cited by 24
“There are methods to produce low cost infrared vein visualization [30].”
MethodAnnalyn, N. S. L., Leow, X. R. G., Ang, W. W., & Lau, Y. (2024) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2023.12.034 · Cited by 23
Low cost high intensity LED illumination device for high uniformity solar testing
D’Alessandro, C., Maio, D. D., Mundo, T., Musto, M., Giamberardino, F. D., Monti, M., Dalena, D., Palmieri, V. G., Luca, D. D., Gennaro, E. D., et al. (2021) · Solar Energy · doi:10.1016/j.solener.2021.04.017 · Cited by 17
Robotic Devices for Assisted and Autonomous Intravenous Access
Koskinopoulou, M., Cheng, Z., Acemoğlu, A., Caldwell, D. G., & Mattos, L. S. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3269844 · Cited by 16
“, using a stereo NIR camera system [10].”
MethodNear-Infrared-to-Visible Vein Imaging via Convolutional Neural Networks and Reinforcement Learning
Leli, V. M., Rubashevskii, A., Sarachakov, A., Rogov, O. Y., & Dylov, D. V. (2020) · International Conference on Control, Automation, Robotics and Vision (ICARCV) · doi:10.1109/icarcv50220.2020.9305503 · Cited by 16
“1A useful review of several brands is given in [16], [17] IR LED illuminator”
BackgroundDeep Learning-Based Vein Localization on Embedded System
Tang, C., Xia, S., Qian, M., & Wang, B. (2021) · IEEE Access · doi:10.1109/access.2021.3058014 · Cited by 11
Van, T. N. P., Tran, T. N., Inujima, H., & Shimizu, K. (2021) · Biomedical Optics Express · doi:10.1364/boe.420337 · Cited by 11
Hamza, M., Skidanov, R. V., & Podlipnov, V. V. (2023) · Sensors · doi:10.3390/s23218895 · Cited by 10
“These challenges are influenced by factors that cause difficulties during this procedure, such as vein size, depth, patient age, skin color, obesity level, and dehydrated patients [12,13].”
BackgroundHyperVein: A Hyperspectral Image Dataset for Human Vein Detection
Ndu, H., Sheikh-Akbari, A., Deng, J., & Mporas, I. (2024) · Sensors · doi:10.3390/s24041118 · Cited by 9
“Failed venipuncture attempts can lead to complications such as vein thrombosis [6], hematoma, or nerve injuries, potentially causing conditions like “causalgia” or complex regional pain syndrome (CRPS) [3,7].”
BackgroundHybrid Color Filters for Multispectral Imaging
He, X., Liu, Y., Beckett, P., Uddin, M. H., Nirmalathas, A. T., & Unnithan, R. R. (2020) · Advanced Theory and Simulations · doi:10.1002/adts.202000137 · Cited by 10
Ng, K. W., Furqan, M. S., Gao, Y., Ngiam, K. Y., & Khoo, E. T. (2023) · Electronics · doi:10.3390/electronics12020292 · Cited by 8
Vein segmentation and visualization of upper and lower extremities using convolution neural network
Laddi, A., Goyal, S., Himani, & Savlania, A. (2024) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2023-0331 · Cited by 8
Nguyen, N. A. D., Huynh, H. N., & Tran, T. N. (2023) · Applied Sciences · doi:10.3390/app131810047 · Cited by 8
A Novel and Easy Method to Locate and Remove First Approved Long-Term Implantable Glucose Sensors
Aktürk, H. K., & BRACKETT, S. J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0023 · Cited by 8
Deep Learning-Based Forearm Subcutaneous Veins Segmentation
Shah, Z., Shah, S. A. A., Shahzad, A., Fayyaz, A., Khaliq, S., Zahir, A., & Meng, G. C. (2022) · IEEE Access · doi:10.1109/access.2022.3167691 · Cited by 11
“The main reason for the failed insertion is that it is difficult to accurately locate the vein and is solely based The associate editor coordinating the review of this manuscript and approving it for publication was R. K. Tripathy . on visualizing and experience of medical practitioners [2].”
BackgroundReal Time Vein Visualization using Near-Infrared Imaging
May, H. Y., & Ernawan, F. (2020) · doi:10.1109/icci51257.2020.9247732 · Cited by 7
Casal-Guisande, C., López-Domene, E., Fernández-Antorrena, S., Fernández-García, A., Torres‐Durán, M., Casal-Guisande, M., & Fernández‐Villar, A. (2025) · Medicina · doi:10.3390/medicina61081321 · Cited by 6
“Near-infrared (NIR) imaging [46], for example, has been used to enhance the visualization of superficial veins, particularly in older children, by projecting real-time images of subcutaneous vasculature onto the skin.”
Enhancing the quantification of post-occlusive reactive hyperemia: a multimodal optical approach
Silva, H., Rezendes, C., & Pinto, P. C. (2025) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-025-03110-7 · Cited by 6
Visualizing veins from color skin images using convolutional neural networks
Tang, C., Yuan, Y., Xia, S., Ma, G., & Wang, B. (2020) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545820500200 · Cited by 6
Shimizu, K., Xian, S., & Guo, J. (2022) · Sensors · doi:10.3390/s22155747 · Cited by 6
Seeing beneath the skin with computational photography
Nowara, E. M., McDuff, D., Sabharwal, A., & Veeraraghavan, A. (2022) · Communications of the ACM · doi:10.1145/3536421 · Cited by 8
“25 These vein viewing devices have successfully reduced the number of attempts of inserting the needles and the associated complications.”
BackgroundMethodInfluentialVein visualization enhancement by dual-wavelength phase-locked denoising technology
Ruan, L., Yin, Z., Zhou, S., Zheng, W., Lu, W., Zhang, T., & Wang, S. (2023) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545823500335 · Cited by 5
Self-citationSpeckle-resolved optical coherence tomography for mesoscopic imaging within scattering media
Cua, M., Blochet, B., & Yang, C. (2022) · Biomedical Optics Express · doi:10.1364/boe.448969 · Cited by 5
“With appropriate optimizations, this project opens up potential for use in applications involving imaging targets deep within scattering media where moderate resolution on the order of hundreds of microns is satisfactory, such as imaging and locating subcutaneous veins for phlebotomy and sclerotherapy [31].”
MethodA portable multispectral vein imaging system
Özkan, H., Aydın, M., Ozcan, O. A., & Zengin, U. (2023) · Journal of Electrical Engineering · doi:10.2478/jee-2023-0008 · Cited by 4
Hassan, A. M., Mohammed, G. T., Hefnawy, G. R., & Khalil, S. S. (2023) · International Journal of Membrane Science and Technology · doi:10.15379/ijmst.v10i2.3146 · Cited by 3
Understanding the Technology-Mediated Home Phlebotomy Ecosystem in India
Gupta, M., Karnatak, N., & Jain, M. (2024) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3637421 · Cited by 3
“Prior work closely related to phlebotomy has focused on devising solutions for distracting patients while drawing blood [58], locating cannulation sites in case of obese and elderly patients [10, 47], and their experiences of taking blood after completing an educational intervention program [11].”
BackgroundTexture Analysis of Near-Infrared Vein Images During Reactive Hyperemia in Healthy Subjects
Silva, H., & Rezendes, C. (2025) · Applied Sciences · doi:10.3390/app15105702 · Cited by 3
H2OPulse: Smartphone-assisted Vein Evaluation for Early Recognition of Dehydration
Islam, T., Rigan, M. M. H., Bhuiyan, M. O. H., Hashem, T., & Rahman, M. M. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3729490 · Cited by 3
“Future work may extend to vein visualization applications, where processed vein images could be projected onto the skin to support medical professionals in procedures, as demonstrated in cases like those in [3, 39].”
Quan, P. V., Nhue, P. N., Tuan, L. D., Hai, L. H., Tu, L. A., Thuan, D. N., & Duong, T. V. (2021) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-75506-5_9 · Cited by 3
Hybrid Color Filters for Multispectral Imaging
He, X., Beckett, P., & Unnithan, R. R. (2021) · Progress in optical science and photonics · doi:10.1007/978-981-16-7515-7_6 · Cited by 3
A Case of Axillary Web Syndrome Caused by Venous Blood Sampling
Kitajima, H., Ichiseki, T., Kaneuji, A., & Kawahara, N. (2023) · Healthcare · doi:10.3390/healthcare11172390 · Cited by 3
“Complications of venous blood sampling include blood specimens, peripheral neuropathy, complex regional pain syndrome, and vagus nerve reflex [13,14].”
BackgroundLocating Hormone-Releasing Contraceptive Implants Using Near-Infrared Light
Aktürk, H. K. (2021) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000004284 · Cited by 3
Visualization of Hand Vein Using Raspberry Pi Images in Contactless Vein Detector
Ibrahim, N. B., Liang, L. K., Zheng, L. Z., Ling, L. Y., Khairulbadri, K. H., Mohamad, M., Poad, H. M., & Sari, S. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-2406-3_21 · Cited by 2
Hiware, S. D., Abuhaimed, S. K., Alshahrani, K., AlRubaish, N. A., Alsahan, A., Alameer, A., Motawei, K., Daimi, S. R. H., Aldahhan, R. A., & Al-Hariri, M. T. (2022) · Electronic Journal of General Medicine · doi:10.29333/ejgm/12737 · Cited by 2
“Medical procedures like venipuncture have a high success rate when an intravenous illuminator is used, compared to the traditional vein engorgement method using a tourniquet [12-14].”
BackgroundMethodAnazi, S. K. A., Woodman, A., Zahrani, W. A. A., Alsanad, M. A., Alzahrani, M. A., Alanazi, F. R., & Rasheed, M. A. U. (2023) · Current Medical Research and Opinion · doi:10.1080/03007995.2023.2222582 · Cited by 2
“Databases were searched using Boolean operators (AND, OR, NOT) expressed in English through a combination of words in a single search string, as shown in Table 1.”
MethodInfluentialA guide to cannulation in adults
Ford, C. (2023) · British Journal of Nursing · doi:10.12968/bjon.2023.32.19.s6 · Cited by 3
Review of the potential benefits and challenges of artificial intelligence in clinical laboratory
Tiwade, Y. R., Bankar, N. J., Mishra, V. H., & Sajjanar, A. (2024) · Journal of Cellular Biotechnology · doi:10.3233/jcb-230119 · Cited by 2
“Its goal is to aid healthcare professionals, such as physicians, nurses, or other practitioners, in finding veins for blood draws or the implantation of intravenous (IV) devices [7].”
Chandra, G., Gultom, M. A., Wahyuningtyas, R., Dwiprasetijo, Z. A., Basari, B., & Rahman, S. F. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-80355-0_5 · Cited by 2
Method of peripheral vein detection using Electrical Impedance Tomography
San-Pablo-Juarez, M.-A., & Orozco-Corona, D. M. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2008/1/012017 · Cited by 2
Feasibility of 830 nm laser imaging for vein localization in dark skin tissue-mimicking phantoms
Bachir, W., & Dargham, F. A. (2022) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-021-01096-x · Cited by 3
“Medical staff are often required to access blood vessels for various reasons, which include conducting blood collection and sampling or to introduce medicine or nutrients into the bloodstream [1].”
BackgroundTRC-Unet: Transformer Connections for Near-infrared Blurred Image Segmentation
Wang, J., Yoshie, O., & Shimizu, K. (2022) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr56361.2022.9956727 · Cited by 2
“Blood vessel segmentation is a fundamental technique in many biomedical imaging applications, such as assisting in injections, detecting cancer, detecting veins, and performing various kinds of surgery [1], [2].”
BackgroundMetasurfaces and Multispectral Imaging
He, X., Beckett, P., & Unnithan, R. R. (2021) · Progress in optical science and photonics · doi:10.1007/978-981-16-7515-7_2 · Cited by 2
Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis
Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B. (2026) · Medicina · doi:10.3390/medicina62030604 · Cited by 2
“First-attempt success rates improved by 28% (RR 1.28, 95% CI 1.14–1.42, p 0.001) [15,22,23], with a number needed to treat of 4.7.”
InfluentialRemizov, N. V., Bataeva, E. M., Stramousov, D. P., Shatskaya, A. A., & Artemyev, D. N. (2023) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe23.09.020307 · Cited by 1
“The spectrum of the LED source emission is usually located between 750 and 950 nm, at the researcher’s discretion [1].”
BackgroundInfluentialVein Detection using Infrared Technology and Machine Learning for Cannulation
Louhith, U., Vishnu, B., Surthesh, V. S., Manimegalai, C. T., & Kalimuthu, K. (2024) · International Conference on Recent Advances in Electrical, Electronics, Ubiquitous Communication, and Computational Intelligence (RAEEUCCI) · doi:10.1109/raeeucci61380.2024.10547844 · Cited by 1
Wang, J., Ieiri, Y., Yoshie, O., & Shimizu, K. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108335 · Cited by 1
Feasibility Study of Noninvasive Subcutaneous Imaging for Vein Localization
Bing, S., Huang, M.-H., Cao, H., & Chiao, J. ‐. (2026) · Electronics · doi:10.3390/electronics15102082 · Cited by 1
Ganding, J. A. (2026) · Philippine Journal of Pathology · doi:10.21141/pjp.2026.601 · Cited by 1
Near-infrared vein finder for assessment of superficial venous malformations
Gupta, S., Mehta, N. K., Bajpai, M., & Gaurav, V. (2023) · Indian Dermatology Online Journal · doi:10.4103/idoj.idoj_641_22 · Cited by 1
Park, S. B., Yeum, I., Ko, D., & Jung, B. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.9.096001 · Cited by 1
“Another promising study involved near-infrared subcutaneous vein imaging based on a projection mapping (PM) that selectively extracted the vein morphology and projected it onto the IROI to observe the vein morphology in the IROI directly.(35) This study proposes a PM system for LSCIs (PMS_LSCI) that projects LSCIs to…”
MethodEnhancing Vein Detection in Hyperspectral Images Using Correlation-PCA Fusion and Clustering
Ndu, H., Sheikh-Akbari, A., & Singh, K. K. (2024) · International Conference on Imaging, Signal Processing and Communications (ICISPC) · doi:10.1109/icispc63824.2024.00014 · Cited by 1
Quantifying superficial vein morphology with near-infrared imaging during venous congestion
Silva, H., & Rezendes, C. (2025) · Phlebology The Journal of Venous Disease · doi:10.1177/02683555251348754 · Cited by 1
“17 – 19 However, their potential has been underexplored and extends beyond this application.”
Penggunaan Vein Viewer Oleh Perawat Dalam Melakukan Tindakan Venipuncture Pada Pasien Anak
Ahzani, Y., & Rahman, L. O. A. (2020) · JKEP · doi:10.32668/jkep.v5i1.299 · Cited by 3
Virtual and Augmented Reality Technologies in Molecular and Anatomical Imaging
Mondal, S., & Achilefu, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-816386-3.00066-1 · Cited by 3
A Single Sensor Based Multispectral Imaging Camera
He, X., Beckett, P., & Unnithan, R. R. (2021) · Progress in optical science and photonics · doi:10.1007/978-981-16-7515-7_5 · Cited by 1
Sahana, D. S., Dayanand Lal, N., Vidya, J., & Bhanujyothi, H. C. (2020) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.c5616.029320 · Cited by 1
Difficult Intravenous Cannulation in Children: Role of Assisting Devices
Dhochak, N., & Lodha, R. (2023) · The Indian Journal of Pediatrics · doi:10.1007/s12098-023-04553-5 · Cited by 1
Metallic Nanohole Integrated on a Dielectric Multilayer for IR Multispectral Imaging
Liu, Y., Beckett, P., He, X., Uddin, M. H., Nirmalathas, A. T., & Unnithan, R. R. (2020) · IEEE Photonics Conference · doi:10.1109/ipc47351.2020.9252505
“Further, by using a multispectral camera operating at IR wavelengths, doctors would be able to more easily detect and locate the position of veins [2].”
BackgroundHe, X., Liu, Y., Ganesan, K., Ahnood, A., Beckett, P., Eftekhari, F., Smith, D., Uddin, M. H., Skafidas, E. S., Nirmalathas, A. T., et al. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2012.01630
Thuan (2021) · Journal of Military Science and Technology · doi:10.54939/1859-1043.j.mst.72a.2021.69-75
SEGMENTATION OF THE VEINS OF THE DORSUM OF THE HAND IN INFRARED IMAGES
Cortés-Galicia, J., Luna-Benoso, B., & Martínez-Perales, J. C. (2021) · INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH · doi:10.36106/ijsr/4634997
Hand Vein Pattern Enhancement using Advanced Fusion Decision
Zidan, M. M., Mustafa, K. A., Mohamed, W. A., & Mohra, A. S. (2022) · Advances in Science and Engineering Technology International Conferences (ASET) · doi:10.1109/aset53988.2022.9734975
“It's worth noting that the rate of absorption differs between the two forms of haemoglobin [12].”
BackgroundRyabochkina, P. A., Belyaev, A. N., Artemov, S. A., Taratynova, A. D., Lyapin, A. A., Khrushchalina, S. A., Kostin, S. V., Pyanzin, D. V., Spirin, A. V., Chaldyshkin, A. N., et al. (2022) · International Conference Laser Optics (ICLO) · doi:10.1109/iclo54117.2022.9839842
Le, D. T. (2021) · Journal of Science and Technique · doi:10.56651/lqdtu.jst.v16.n03.280
A Review on Skin Pigment and Vein Pattern Detection Techniques
Kharakwal, K., Raiwani, Y. P., & Verma, R. (2022) · Communications in computer and information science · doi:10.1007/978-3-031-24367-7_5
Current and emerging vein identification technology for phlebotomy and peripheral I.V. cannulation
Kaganovskaya, M., Capitulo, K. L., & Wuerz, L. (2023) · Nursing · doi:10.1097/01.nurse.0000905708.30992.e9 · Cited by 2
Unique Contactless Device to Detect Veins and Heart Rate
Sreeja, M., Grace, C. S., Deepika, M. G., Mulam, H., & Kuchulakanti, H. (2023) · Advances in engineering research/Advances in Engineering Research · doi:10.2991/978-94-6463-252-1_17
An Economic Approach to Precise Vein Detection and Visualization
Crisan, S., & Somesan, A. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-62502-2_33
A Low-Cost Embedded Imaging System for Low-Limb Vascular Metrics Monitoring
Liu, C. S., Gherardi, A., Li, H., Xia, J., & Xu, W. (2024) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn63547.2024.10780688
“Human veins, located 1-3 mm beneath the dermis [7], [8], are visualized effectively using NIR light, which penetrates tissue with less absorption and scattering than visible light [9].”
Owen, O., Mulkey, D. C., & Nieves, A. (2025) · AJN American Journal of Nursing · doi:10.1097/ajn.0000000000000016 · Cited by 3
Assistive Cartesian Healthcare Robot for Forearm Vein Puncturing
Perera, C., Ananda, B. G. C., Samarakoon, S. M. U. S., Herath, H. M. K. K. M. B., & Yasakethu, S. L. P. (2024) · International Conference on Advancements in Computing (ICAC) · doi:10.1109/icac64487.2024.10851158
“Due to human factor variability, [10] developed a low-cost vein finder prototype employing near-infrared light technology, although they also recommended more thorough testing before commercialization.”
Ouedraogo, R., Alves, A., Bruant, A., Sy, O., Osorio, C. T., Schortgen, F., Chenal, A., Contou, D., Krzyzaniak, L., Fartoukh, M. S., et al. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-090611
Feasibility of Near-Infrared Image Guided Vascular Identification and Access in Dogs
Bowden, S., Johnson, J. N., & Pierce, K. V. (2025) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.70043
“Thus, prompting investigation into the utility of vascular imaging aids when palpation alone is insufficient [1–3, 6, 9, 14].”
Bennakhi, H., Alajmi, M. S., Baqer, M., Qasem, N., Iqbal, Z., Abosaif, N., & Philliskirk, C. (2025) · BMJ Open Quality · doi:10.1136/bmjoq-2024-003232
Naseri, S., Neshat, H., Musavi, S., & Ghorbani, F. (2025) · Comprehensive Child and Adolescent Nursing · doi:10.1080/24694193.2025.2530477
“Although the placement of intravenous catheters is ostensibly a straightforward technique (Pan et al., 2019), It poses significant challenges in children and young people due to their unique anatomical and physiological characteristics, including age, prematurity, underlying medical conditions, and…”
A study on image processing of vein extraction images according to development of vein detector
Bang, S.-H., Kim, S.-H., & Jeong, J.-H. (2025) · Technology and Health Care · doi:10.1177/09287329251389493
Smart Vein Localization: A Hybrid Approach Using Embedded Vision and Real-Time Laser Guidance
Hauw, M. R. C., Winarta, A., Ang, E. M., Astuti, W., & Manurung, R. V. (2025) · International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET) · doi:10.1109/icramet67419.2025.11349876
“The paper highlights the potential of these devices to improve vein selection while noting the need for further clinical testing and standardization due to methodological and demographic variations across studies [2].”
Performance verification of blood vessel detection system using near-infrared light
Park, J., & Kim, J. (2026) · Technology and Health Care · doi:10.1177/09287329251414328
Near-Infrared Vein Visualization for Point-Of-Care Diagnosis of Cutaneous Venous Malformations
Gnarra, M., Siegel, D., Glick, S., & Shmuylovich, L. (2026) · Dermatologic Surgery · doi:10.1097/dss.0000000000005083
Deblurring NIR Transillumination Vein Image Using Attention Residual U-Net
Huynh, T. L., Nguyen, K. D., Huynh, H. N., Dam, P. A., Nguyen, B. T. L., & Tran, T. N. (2025) · IEEE International Biomedical Instrumentation and Technology Conference (IBITeC) · doi:10.1109/ibitec66306.2025.11473075
Wu, H., Guo, B.-C., Chang, Y., Chen, C.-Y., Jan, S., & Lee, E. (2026) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001355
Comprehensive Review of Advancements in Near-Infrared Imaging Techniques for Vein Detection
Das, S., Ghos, T. C., Khan, M. A., Chandra, P., Bino, J., Venkateswara, U., Immanuel, K., & Ahammed, M. T. (2026) · IEEE International Conference on Quantum Photonics, Artificial Intelligence & Networking (QPAIN) · doi:10.1109/qpain69676.2026.11546612
Kryukov, A. V., & Bukova, V. I. (2025) · Journal of Optical Technology · doi:10.1364/jot.92.000738
A safety-oriented multimodal decision framework for venipuncture assistance
Huang, Z., Xu, Y., Wang, Y., Peng, Y., Huang, X., Feng, S., Tang, X., Jiang, W., Zhang, Y., Lai, J., et al. (2026) · Pattern Recognition · doi:10.1016/j.patcog.2026.114982
Suleman, S. K., BakirYahya, N., Nilsson, S., & Enskär, K. (2026) · Health Science Reports · doi:10.1002/hsr2.73063
Infrared Technology for Vein Visualization: Device Development
Ivanov, N. V., Nicu, A.-I., & Roman, N. M. (2026) · Bioengineering · doi:10.3390/bioengineering13101217
“In contrast, the proposed system uses an operator-independent optical approach, leveraging the fact that deoxygenated hemoglobin absorbs NIR light significantly more than surrounding tissue to create a clear, real-time map on a screen or skin surface [3,6,7].”
Influential
Metadata
- Authors
- Pan, C.-T., Francisco, M. D., Yen, C.-K., Wang, S.-Y., & Shiue, Y.-L.
- Affiliations
- National Sun Yat-sen University (TW)
- Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-sen University (NSYSU), Kaohsiung 80424, Taiwan
- Corresponding author
- Shiue, Yow-Ling
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-08-16
- Volume
- 19
- Issue
- 16
- Pages
- 3573
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC6719195
- OpenAlex
- W2967660745
- Semantic Scholar
- e442e7a08b4592a54132c5c81ba54eaa7563059f
- Cited by
- 93
- References
- 67
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 11 · 2023: 16 · 2022: 12 · 2021: 17 · 2020: 12
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Council
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Keywords
- near-infrared imaging, cannulation, phlebotomy, low-cost prototype, vein detection, pre-analytical errors, blood sampling, human factors
- MeSH terms
- Catheterization, Cost-Benefit Analysis, Humans, Semiconductors, Veins, Phlebotomy, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.