The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Motion artifact reduction in wearable photoplethysmography based on multi-channel sensors with multiple wavelengths.
Open accessAbstract
Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“First, our approximation of wear time was based on available per-minute HR values, which have been used in previous studies22; however, wearable device data are affected by motion artifacts.64,65 Thus, our measure of wear time may be an imperfect proxy.”
From Association of Demographic and Socioeconomic Indicators With the Use of Wearable Devices Among Children (2023) · cites this paper as [65]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Photophysical processes in recent medical laser developments: A review
Boulnois, J.-L. (1986) · Lasers in Medical Science · doi:10.1007/bf02030737 · Cited by 663
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246160 · Cited by 486
RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise
Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04142-5 · Cited by 438
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
Ram, M. R., Madhav, K. V., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2175832 · Cited by 345
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189
Reddy, K. A., George, B., & Kumar, V. J. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2009136 · Cited by 165
A Real Time Analysis of PPG Signal for Measurement of SpO2 and Pulse Rate
Bagha, S., & Shaw, L. (2011) · International Journal of Computer Applications · Cited by 143
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–153 of 153
Wearable Biosensors and AI Analytics for Continuous Health Monitoring and Early Disease Detection
Mohmmed, H. A. (2024) · Academic International Journal of Engineering Science · doi:10.59675/e225 · Cited by 1
Deep learning ensemble approach to multi-wavelength photoplethysmogram for sleep stage detection
Park, Y., Cho, H., & Oh, J. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109689 · Cited by 1
Mäkinen, J.-T., Vartiainen, J., Heikkinen, O., Vornanen, A., Similä, H., D’Anna, E., Maansaari, K., & Kangas, M. (2026) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.3076768 · Cited by 1
Wang, Z., Jiang, C., An, Z., & Guo, R. (2026) · Science China Technological Sciences · doi:10.1007/s11431-025-3096-y · Cited by 1
Choi, H. (2025) · Electronics · doi:10.3390/electronics14183570 · Cited by 1
Reliability Estimation of Heart Rate Measurement Using Wrist-Worn Devices
Yoshikawa, H., Hayashi, M., Uchiyama, A., & Teruo Higashino, Y. (2021) · International Conference on Mobile Computing and Ubiquitous Network (ICMU) · doi:10.23919/icmu50196.2021.9638918 · Cited by 1
Николов, Н. А., Soloviov, O. I., & Burkovskyi, Y. (2022) · Ukrainian Journal of Occupational Health · doi:10.33573/ujoh2022.02.155 · Cited by 1
An Information-Theoretic Framework for Joint CS-ICA Recovery of Sparse BiosignalsPreprint
Alghorani, Y., & Ikki, S. (2020) · doi:10.36227/techrxiv.12923891.v2
Statistical Description of SaO2–SpO2 Relationship for Model of Oxygenation in Premature Infants
Rafl-Huttova, V., Ráfl, J., Möller, K., Bachman, T. E., Kudrna, P., & Rožánek, M. (2022) · Electronics · doi:10.3390/electronics11091314
An Information-Theoretic Framework for Joint CS-ICA Recovery of Sparse BiosignalsPreprint
Alghorani, Y., & Ikki, S. (2020) · doi:10.36227/techrxiv.12923891
Reliability Estimation and Filtering of Heart Rate Measurement Using Inertial Sensor during Exercise
Yoshikawa, H., Hayashi, M., Uchiyama, A., & Teruo Higashino, Y. (2022) · Sensors and Materials · doi:10.18494/sam3969
Hardware and Algorithmic Approaches to Combat Motion Artifacts in Photoplethysmographic Data
Han, D., Mohagheghian, F., & Chon, K. H. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00135-7
Análise da influência do tom de pele no sinal de fotopletismografia (PPG)
Rosa, A. G. R. D., Schmith, J., de Figueiredo, R. M., Prade, L. R., PINHEIRO, J. A., & Rigo, S. J. (2023) · doi:10.5753/sbcas.2023.229566
An Information-Theoretic Framework for Joint Cs-Ica Recovery of Sparse BiosignalsPreprint
Alghorani, Y., & Ikki, S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4798974
Refined matrix completion for spectrum estimation of heart rate variability
Lü, L., Zhu, T., Tan, Y., Zhou, J., Yang, J., Clifton, L., Zhang, Y., & Clifton, D. A. (2024) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2024296
Deep Neural Network to Remove Motion Artifacts from Heart Rate Sensor Embedded on Handle Cane
Villalba-Bravo, R., Ruiz-Barroso, P., Castro, F. M., Trujillo-León, A., Guil, N., & Vidal‐Verdú, F. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784567
Robust Heart Rate Detection via Multi-Site Photoplethysmography
Meier, M., & Holz, C. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782155
Optimization of PPG Signal Processing based on Hybrid Filtering Technology
Xue, R. (2025) · Applied and Computational Engineering · doi:10.54254/2755-2721/2025.22712
Qie, A., Li, X., Yang, J., & Wang, X. (2025) · International Conference on Biomedical and Intelligent Systems (IC-BIS) · doi:10.1145/3745034.3745084
A Machine Learning-Based System for Non-Invasive Multi-Vital Sign Monitoring Using PPG Signals
Amanullah, A. R., Mukhtar, H., & Cahyadi, W. A. (2025) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima66552.2025.11233329
Wang, W., Zhang, X., Du, J., & Zhao, W. (2025) · Computers & Security · doi:10.1016/j.cose.2025.104686
Hybrid CNN-BiLSTM Autoencoder for Anomaly Detection in Remote Photoplethysmography(rPPG) Signals
Mmadi, M., Kamucha, G., & Maina, C. W. (2025) · International Journal of Electrical and Electronics Research · doi:10.37391/ijeer.130410
ПЕРЕВАГИ ЗАСТОСУВАННЯ ФОТОПЛЕТИЗМОГРАФІЧНИХ ДАТЧИКІВ У ПРОЦЕСАХ ПІДГОТОВКИ КУРСАНТІВ-ПОЖЕЖНИКІВ
Оскерко, С. (2025) · ГРААЛЬ НАУКИ · doi:10.36074/grail-of-science.14.11.2025.087
Biomedical Signal Acquisition and Processing
Badnjević, A., & Spahić, L. (2026) · Series in bioengineering · doi:10.1007/978-3-032-10982-8_2
Diffusion-Based PPG-to-ECG Translation with Dynamic ROI Selection
Chu, C., & Kim, S.-B. (2025) · Journal of Korean Institute of Industrial Engineers · doi:10.7232/jkiie.2025.51.6.475
Chow, J., Ahmadi, N., Adiono, T., & Ruskanda, F. Z. (2025) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas67402.2025.11378439
Zhang, Y. (2026) · Research Square · doi:10.21203/rs.3.rs-9176759/v1
VYRE: Low-Burden and Robust Oscillometric Ring-Based System for Frequent Blood Pressure Monitoring
Radmehr, A., Seethakantha, S. K., Aziz, A., Tran, Q. T., Nair, A., Saulnier, W., Ganesan, D., & Nguyen, P. (2026) · doi:10.1145/3774906.3802789
A multitask Transformer-VAE framework for robust PPG denoising and atrial fibrillation screening
Zhang, L., & Yuan, L. (2026) · BMC Medical Imaging · doi:10.1186/s12880-026-02399-9
Prakash, R. B., Dhilipkumar, V., Raut, I., Rampelli, Y. S., Geman, O., Toderean, R., & Postolache, O. A. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-24724-7_7
Hu, C., Pham, H. M., Zhang, Y., Yan, G., Ma, X., Wu, Y., Kandappu, T., Misra, A., & Ma, D. (2026) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3810216 · Cited by 2
Cook, J. M., Chen, C., Inan, F. B., Nichols, C. J., Rahman, F. N., Nawar, A., Reichelt, L. J., Cho, M., Sangar, Y., Hester, J., et al. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3702932
AI and IoT Enabled ECG and PPG Based Early Detection of Cardiovascular Abnormalities
Hugar, V. C., H., P. S., Manjunath Swamy, K., P., A. R., Gowda, D. E., & Ganesh, Y. (2026) · doi:10.26634/jiot.4.1.11155
Tipsavak, A., Punsawad, Y., Songnuy, T., Kliangkhlao, M., Chaithong, P., Efendi, M. A., & Sahoh, B. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100695
Phan, K. D., Lưu, T. T., Le, T. T., Tran-Quang, D.-H., & Huynh, V.-T. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae91f1
Datta, T., & Frederiksen, M. R. (2026) · International Conference on Ubiquitous Robots (UR) · doi:10.1109/ur69537.2026.11626683
Multimodal Sensing via Cost–Aware Progressive Inference for Stress Detection in Wearables
Varghese, S., Jonnala, K. S., & Spiliopoulou, M. (2026) · IEEE International Conference on Mobile Data Management (MDM) · doi:10.1109/mdm71479.2026.00063
Artificial Intelligence in Exercise Programming and Coaching: Opportunities and Limitations
Reiner, S. L., Pearson, R. C., Reed, R. A., Olenick, A., & Pojednic, R. M. (2026) · Current Sports Medicine Reports · doi:10.1249/jsr.0000000000001357
Zhang, X., Xu, C., Huang, G., Wang, Z., Liang, Y., & Cao, L. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111122
Silk fibroin-based wearable bioelectronics for self-powered healthcare
Ansari, A. I., & Dekhtyar, Y. (2026) · International Journal on Interactive Design and Manufacturing (IJIDeM) · doi:10.1007/s12008-026-02669-4
NEST: A Neck-Embedded Soft optical Tracker for Long-Term Laryngeal Activity Monitoring
Yuan, G., Geng, K. (., Liu, Y., & Bai, W. (2026) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps69128.2026.11645077
Kang, B., & Bae, J. (2026) · IEEE Access · doi:10.1109/access.2026.3730182
Lee, W., 신재연, Song, M., Song, M.-K., Kim, K. M., Noh, G., & Cho, S. P. (2026) · Sensors · doi:10.3390/s26175676
Joshi, D. D., Saraboji, K., Shaik, A. T., Sakalabaktula, K. S. K., Purohit, S., Godugu, S., Nirmal, J., Kayarkar, R., Correa, B. H. M., Gangidi, N., et al. (2026) · Life · doi:10.3390/life16091530
Self-citationŢiţoc, O.-A., & Tudose, D. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.113072
Development of an efficient deep learning model for arrhythmia detection from consumer smartwatches
George, D.-C., Hulubeac, M.-A., Grămadă, Ş.-L., Balint, Z., & Diosan, L. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1882739
DailyBeat: Reliable Cardiac Sensing Under Self-Induced Dynamic Interference Using mmWave Radar
Chang, Z., Wang, P., Ma, X., Zhang, F., Zhang, D., Chen, L., Jouaber, B., & Zhang, D. (2026) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3831967 · Cited by 1
Watanabe, Y., Yamane, N., Sathyanarayana, A., Goodwin, M. S., & Mishra, V. (2026) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3831657 · Cited by 1
Analysis of Modification in Photoplethysmographic Signal Descriptors Induced by Orthostatic Maneuver
Śmigielski, B. T., Chołuj, M. N., Pałasz, M., Żyliński, M., & Cybulski, G. (2026) · Advances in intelligent systems and computing · doi:10.1007/978-3-032-33719-1_14
Ricci, M., Suárez, D., Bertomeu‐González, V., Martínez‐Rodrigo, A., Alcaraz, R., & Rieta, J. J. (2026) · Sensors · doi:10.3390/s26206636
Analysis of CNN-ANFIS Model for Cardiovascular System Vital Parameter Monitoring
Kutty, A., Chris Prema, S., & Selvaganesan, N. (2026) · IEEE International Conference on Recent Advances in Electronics, Communication, Computing, Automation and Power (RECCAP) · doi:10.1109/reccap69368.2026.11723370
Xu, X., Zheng, W., Song, Y., Sun, Z., Ye, Q., Tao, Y., Dai, C., Dong, K., & Liu, Q. (2026) · Sensor Review · doi:10.1108/sr-03-2026-0314
Metadata
- Authors
- Lee, J., Kim, M., Park, H.-K., & Kim, I. Y.
- Affiliations
- Hanyang University (KR)
- Corresponding author
- Park, Hoon-Ki
- Kim, In Young
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-03-09
- Volume
- 20
- Issue
- 5
- Pages
- 1493
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7085621
- OpenAlex
- W3009321689
- Cited by
- 153
- References
- 29
- Citations by year
- 2026: 34 · 2025: 27 · 2024: 13 · 2023: 15 · 2022: 35 · 2021: 19 · 2020: 10
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Research Foundation of Korea (2018R1A5A7025522)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- photoplethysmography, motion artifact reduction, wearable sensors, multi-channel sensor, multiple wavelengths, independent component analysis, truncated singular value decomposition, heart rate estimation, R-peak detection, electrocardiogram, walking and running
- MeSH terms
- Wearable Electronic Devices, Adult, Electrocardiography, Equipment Design, Female, Heart Rate, Humans, Male, Signal Processing, Computer-Assisted, Walking, Artifacts, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review