A Novel Singular Value Decomposition-Based Denoising Method in 4-Dimensional Computed Tomography of the Brain in Stroke Patients with Statistical Evaluation

Open access

The DOI matches its Crossref record; 29 of the 32 references it cites were found in a registry or an index; 2 of the 11 sources its claims cite were checked for support.

Abstract

Computed tomography (CT) is a widely used medical imaging modality for diagnosing various diseases. Among CT techniques, 4-dimensional CT perfusion (4D-CTP) of the brain is established in most centers for diagnosing strokes and is considered the gold standard for hyperacute stroke diagnosis. However, because the detrimental effects of high radiation doses from 4D-CTP may cause serious health risks in stroke survivors, our research team aimed to introduce a novel image-processing technique. Our singular value decomposition (SVD)-based image-processing technique can improve image quality, first, by separating several image components using SVD and, second, by reconstructing signal component images to remove noise, thereby improving image quality. For the demonstration in this study, 20 4D-CTP dynamic images of suspected acute stroke patients were collected. Both the images that were and were not processed via the proposed method were compared. Each acquired image was objectively evaluated using contrast-to-noise and signal-to-noise ratios. The scores of the parameters assessed for the qualitative evaluation of image quality improved to an excellent rating (p < 0.05). Therefore, our SVD-based image-denoising technique improved the diagnostic value of images by improving their quality. The denoising technique and statistical evaluation can be utilized in various clinical applications to provide advanced medical services.

Overview

CoChat Summary

TL;DR

This study applied a singular value decomposition (SVD)-based denoising method to 4D brain CT perfusion images from 20 suspected acute stroke patients, reconstructing images after excluding low singular-value components at thresholds of 5–40% of the second singular value. Denoising significantly improved SNR and CNR, with the 25% threshold suggested as a potential optimum for axial basal ganglia images.

Key findings

  • SVD denoising significantly increased SNR and CNR at the basal ganglia level; the largest SNR improvement was a 16% increase at the 40% threshold (t = 2.908, p < 0.005), and the largest CNR improvement was a 43% increase at the 40% threshold (t = 6.327, p < 0.001).
  • The 25% threshold had the best statistical significance by paired t-test (t = 3.764, p < 0.001), with a 14% SNR increase and a 37% CNR increase (t = 6.080, p < 0.001); the authors considered 25% potentially optimal for balancing noise reduction and diagnostic information.
  • The full-rank original image contained 27 singular value components; at the 5% threshold, the 1st–20th singular values were included and the 21st–27th were separated, while at the 40% threshold only the 1st and 2nd singular values were included after separating 25 signal components.
  • The abstract reports qualitative image-quality scores improved to an excellent rating (p < 0.05), though the Results section presents quantitative SNR/CNR analyses.

Methods

  • Retrospective, IRB-approved study of 20 suspected acute stroke patients (excluded if already diagnosed with ischemic or hemorrhagic stroke on CT) at Kosin University Medical Center, with data acquired from 1 January 2016 to 1 December 2016.
  • 4D CTP was performed on a 128-section dual-source CT scanner at 80 kVp and 200 mAs with 0.28 s rotation time, 32 × 1.2 mm collimation, 1.25 s temporal interval, 84 mm coverage, and reconstruction at 5 mm slice thickness with 3 mm interval; contrast injection used 40 cc non-ionic contrast at 6 mL/s followed by 60 cc saline.
  • SVD decomposed the reshaped 2D spatio-temporal data matrix; thresholds were set at 5–40% of the second singular value (λ2) in 5% increments, singular values above threshold were retained and those below were set to zero, and denoised datasets were reconstructed. SNR and CNR at the basal ganglia were calculated, and paired t-tests compared original versus each denoised image using SPSS 25.0.

Limitations

  • The paper states that the SVD-based technique was not applied to perfusion maps, the sample size was small, and only quantitative image quality was estimated, so diagnostic accuracy still needs assessment.
  • The paper states that the threshold value was selected on an experiential basis, with no golden rule because signal and noise boundaries remain vague, and that reducing noise is a trade-off for acquiring diagnostic information.
  • Evident from the text: the study used single-center retrospective data, and despite the abstract mentioning qualitative evaluation, the Results focus on quantitative SNR/CNR without a reported reader-performance or diagnostic-accuracy assessment.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/s20113063

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Flow chart of singular value decomposition (SVD)-based denoising technique.
Figure 1 Flow chart of singular value decomposition (SVD)-based denoising technique.CC BY · PubMed Central
Figure 2 Example of a singular value corresponding to a used dataset. The 2nd component was selected to determine the threshold of the denoised image.
Figure 2 Example of a singular value corresponding to a used dataset. The 2nd component was selected to determine the threshold of the denoised image.CC BY · PubMed Central
Figure 3 (a) Example of denoised images based on thresholding values; a1—original image, a2–a9—denoised images. (b) Example of separated noise components in accordance with thresholding; b1—no noise component was separated from the original image, b2–b9—noise components separated from the original image corresponding to Figure 3.
Figure 3 (a) Example of denoised images based on thresholding values; a1—original image, a2–a9—denoised images. (b) Example of separated noise components in accordance with thresholding; b1—no noise component was separated from the original image, b2–b9—noise components separated from the original image corresponding to Figure 3.CC BY · PubMed Central
Figure 4 (a) Comparison between the original image (80 kVp, 200 mAs, a1 the denoised image using SVD (25% threshold, a2, and the high dose image (120 kVp, 320 mAs, a3). (b) Comparison between the original image (80 kVp, 200 mAs, b1), the denoised image using SVD (25% threshold, b2), and the high dose image (120 kVp, 320 mAs, b3).
Figure 4 (a) Comparison between the original image (80 kVp, 200 mAs, a1 the denoised image using SVD (25% threshold, a2, and the high dose image (120 kVp, 320 mAs, a3). (b) Comparison between the original image (80 kVp, 200 mAs, b1), the denoised image using SVD (25% threshold, b2), and the high dose image (120 kVp, 320 mAs, b3).CC BY · PubMed Central
Figure 5 (a) Mean and standard deviation (SD) of the signal-to-noise ratio (SNR) at the basal ganglia level corresponding to the threshold values. (b) Mean and standard deviation (SD) of the contrast-to-noise ratio (CNR) at the basal ganglia level corresponding to the threshold values.
Figure 5 (a) Mean and standard deviation (SD) of the signal-to-noise ratio (SNR) at the basal ganglia level corresponding to the threshold values. (b) Mean and standard deviation (SD) of the contrast-to-noise ratio (CNR) at the basal ganglia level corresponding to the threshold values.CC BY · PubMed Central

Verification

Claims the paper makes

2 Valid · 0 Not valid · 6 Not checked · 34 Own results and interpretations

21 more claims

Create a free account to see all 42 claims and to verify the 9 references still open.

See all claims — free account
  • Probably not a substantial claim. 11
  • It may state two separate claims as one. 7

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Research works printed but not linked: 1

  1. Shlens J. A tutorial on principal component analysis derivation, discussion and singular value decomposition Mar 2003 25 1 16

Cited by

See all 17

Metadata

Authors
Yang, W., Hong, J.-Y., Kim, J.-Y., Paik, S.-H., Lee, S. H., Park, J.-S., Lee, G., Kim, B. M., & Jung, Y.-J.
Affiliations
  • Dong-A University Hospital (KR)
  • Dongseo University (KR)
  • Inje University Ilsan Paik Hospital (KR)
  • Korea University (KR)
  • Samsung Medical Center (KR)
Corresponding author
  • Kim, Beop Min
  • Jung, Young-Jin
Venue
Sensors
Publisher
MDPI AG
Published
2020-05-28
Volume
20
Issue
11
Pages
3063
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3031827868
Cited by
17
References
32
Citations by year
2025: 2 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 2
FWCI
0.87
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Research Foundation of Korea (2015M3C7A1029034)
  • Korea Health Industry Development Institute (KHIDI)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image and Signal Denoising Methods
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Enhancement Techniques
Keywords
singular value decomposition, image denoising, brain perfusion imaging, acute stroke, radiation dose reduction, image quality, signal-to-noise ratio, contrast-to-noise ratio
MeSH terms
Algorithms, Brain, Humans, Image Processing, Computer-Assisted, Tomography, X-Ray Computed, Stroke, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.