Artificial Intelligence in Decision Support Systems for Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Type 1 diabetes (T1D) is a chronic health condition resulting from pancreatic beta cell dysfunction and insulin depletion. While automated insulin delivery systems are now available, many people choose to manage insulin delivery manually through insulin pumps or through multiple daily injections. Frequent insulin titrations are needed to adequately manage glucose, however, provider adjustments are typically made every several months. Recent automated decision support systems incorporate artificial intelligence algorithms to deliver personalized recommendations regarding insulin doses and daily behaviors. This paper presents a comprehensive review of computational and artificial intelligence-based decision support systems to manage T1D. Articles were obtained from PubMed, IEEE Xplore, and ScienceDirect databases. No time period restrictions were imposed on the search. After removing off-topic articles and duplicates, 562 articles were left to review. Of those articles, we identified 61 articles for comprehensive review based on algorithm evaluation using real-world human data, in silico trials, or clinical studies. We grouped decision support systems into general categories of (1) those which recommend adjustments to insulin and (2) those which predict and help avoid hypoglycemia. We review the artificial intelligence methods used for each type of decision support system, and discuss the performance and potential applications of these systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · cited 4×
“Later in 2010, Wilinska et al. [32] outlined an additional two compartment meal model describing the absorption of carbohydrates into plasma glucose, which became a part of the Cambridge Simulator.”
BackgroundMethodInfluentialMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030 · cited 2×
“0% for the Medtronic 670 g [21] and 10% for the Tandem Control-IQ system [2], while reducing the percent time in hypoglycemia from 6.”
BackgroundExercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · cited 1×
“Existing treatment strategies have evolved over the last 100 years from one-time daily insulin injections, into multiple injections of modern long-acting and rapid-acting insulin formulations, and the automated insulin delivery (AID) systems that are commercially available today [1,2].”
BackgroundParkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 1×
“0% for the Medtronic 670 g [21] and 10% for the Tandem Control-IQ system [2], while reducing the percent time in hypoglycemia from 6.”
BackgroundKirwan, M., Vandelanotte, C., Fenning, A., & Duncan, M. J. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2588 · Cited by 343
Charpentier, G., Benhamou, P.-Y., Dardari, D., Clergeot, A., Franc, S., Schaepelynck-Belicar, P., Catargi, B., Melki, V., Chaillous, L., Farret, A., et al. (2011) · Diabetes Care · doi:10.2337/dc10-1259 · Cited by 292
Wu, Y., Yao, X., Vespasiani, G., Nicolucci, A., Dong, Y., Kwong, J., Li, L., Sun, X., Tian, H., & Li, S. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.6522 · Cited by 283 · cited 1×
“While some smart-phone-based DSSs have been evaluated in clinical studies [9,10], the outcomes have been mixed with some showing a benefit in terms of improving glycemic outcomes [11,12], while others do not [13,14].”
BackgroundClosed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes
Stewart, Z. A., Wilinska, M. E., Hartnell, S., Temple, R. C., Rayman, G., Stanley, K. P., Simmons, D., Law, G. R., Scott, E. M., Hovorka, R., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602494 · Cited by 279
Resistance Versus Aerobic Exercise
Yardley, J. E., Kenny, G. P., Perkins, B. A., Riddell, M. C., Balaa, N., Malcolm, J., Boulay, P., Khandwala, F., & Sigal, R. J. (2013) · Diabetes Care · doi:10.2337/dc12-0963 · Cited by 250 · cited 1×
“Resistance training and high intensity interval exercise are known to cause less of a drop in glucose during exercise and may even result in increases in glucose, especially when done in the morning in the fasted state, when insulin levels are the lowest [104].”
BackgroundSimulation Environment to Evaluate Closed-Loop Insulin Delivery Systems in Type 1 Diabetes
Wilinska, M. E., Chassin, L. J., Acerini, C. L., Allen, J. M., Dunger, D. B., & Hovorka, R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400117 · Cited by 244 · cited 1×
“[32] outlined an additional two compartment meal model describing the absorption of carbohydrates into plasma glucose, which became a part of the Cambridge Simulator.”
BackgroundRapid evidence review of mobile applications for self-management of diabetes
Veazie, S., Winchell, K., Gilbert, J., Paynter, R., Ivlev, I., Eden, K. B., Nussbaum, K., Weiskopf, N., Guise, J.-M., & Helfand, M. (2018) · Journal of General Internal Medicine · doi:10.1007/s11606-018-4410-1 · Cited by 170 · cited 2×
“The primary clinical objective of AI-based DSS is to improve glycemic outcomes and prevent medical complications related to diabetes such as hypoglycemia [9].”
BackgroundXie, J., & Wang, Q. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2975959 · Cited by 158 · cited 3×
“Xie and Wang [124] explored this concept by designing a non-linear ARMAX model that would recommend the optimal carbohydrate intake, insulin dosage, and target exercise heartrate required to optimize a person’s daily time in glucose target range.”
BackgroundCastle, J. R., El Youssef, J., Wilson, L. M., Reddy, R., Resalat, N., Branigan, D., Ramsey, K., Leitschuh, J., Rajhbeharrysingh, U., Senf, B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0228 · Cited by 152
Self-citationResalat, N., El Youssef, J., Tyler, N., Castle, J., & Jacobs, P. G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0217301 · Cited by 78 · cited 3×
“While these dynamic models can be used to forecast glycemic outcomes [15,26,27], many of these physical models have been developed to simulate the glucose dynamics of T1D populations [28,29] and to design and evaluate DSS algorithms [19].”
MethodSelf-citationPrediction and prevention of hypoglycaemic events in type-1 diabetic patients using machine learning
Vehí, J., Contreras, I., Oviedo, S., Biagi, L., & Bertachi, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219850682 · Cited by 76 · cited 1×
“[100] developed a bimodal hypoglycemia prediction algorithm.”
Prediction of hypoglycemia during aerobic exercise in adults with type 1 diabetes
Reddy, R., Resalat, N., Wilson, L. M., Castle, J. R., El Youssef, J., & Jacobs, P. G. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818823792 · Cited by 75
Self-citationDrion, I., Pameijer, L. R., van Dijk, P. R., Groenier, K. H., Kleefstra, N., & Bilo, H. J. G. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815585871 · Cited by 74
Reddy, M., Pesl, P., Xenou, M., Toumazou, C., Johnston, D., Georgiou, P., Herrero, P., & Oliver, N. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0413 · Cited by 70
Hernández-Ordoñez, M., & Campos-Delgado, D. U. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.028 · Cited by 43
Cited by
Jacobs, P. G., Herrero, P., Facchinetti, A., Vehi, J., Kovatchev, B., Breton, M. D., Cinar, A., Nikita, K. S., Doyle, F. J., Bondia, J., et al. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3331297 · Cited by 113
Self-citationEnhancing the Capabilities of Continuous Glucose Monitoring With a Predictive App
Herrero, P., Andorrà, M., Babion, N., Bos, H., Koehler, M., Klopfenstein, Y., Leppäaho, E., Lustenberger, P., Peak, A., Ringemann, C., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267818 · Cited by 31
Continuous glucose monitoring for children with hypoglycaemia: Evidence in 2023
Worth, C., Hoskyns, L., Salomon-Estebanez, M., Nutter, P. W., Harper, S., Derks, T. G. J., Beardsall, K., & Banerjee, I. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1116864 · Cited by 29
Syed, W., & Al-Rawi, M. B. A. (2024) · Technology and Health Care · doi:10.3233/thc-230784 · Cited by 24
Metadata
- Authors
- Tyler, N. S., & Jacobs, P. G.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-06-05
- Volume
- 20
- Issue
- 11
- Pages
- 3214
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3033283414
- Cited by
- 93
- References
- 23
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.