CoChat

Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices

Campuzano, Susana, Pedrero, María, Gamella, Maria, Serafín, Verónica, Yáñez-Sedeño, Paloma, Pingarrón, José Manuel · 2020 · Sensors
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people’s safety and health are also commented upon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20123376

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 73

  1. Zhang, 2019, Nanotechnology and nanomaterials-based no-wash electrochemical biosensors: From design to application, Nanoscale, 11, 19105, 10.1039/C9NR05696C · DOI
  2. Li, 2019, High frequency, calibration-free molecular measurements in situ in the living body, Chem. Sci., 10, 10843, 10.1039/C9SC04434E · DOI
  3. Idili, 2019, Calibration-free measurement of phenylalanine levels in the blood using an electrochemical aptamer-based sensor suitable for point-of-care applications, ACS Sens., 4, 3227, 10.1021/acssensors.9b01703 · DOI
  4. Duan, 2015, Nanozyme-strip for rapid local diagnosis of Ebola, Biosens. Bioelectron., 74, 134, 10.1016/j.bios.2015.05.025 · DOI · Paper page
  5. Qiu, 2019, Carbon nanotube-based lateral flow immunoassay for ultrasensitive detection of proteins: Application to the determination of IgG, Microchim. Acta, 186, 436, 10.1007/s00604-019-3508-4 · DOI
  6. Li, 2018, Electrochemical DNA-based sensors for molecular quality control: Continuous, real-time melamine detection in flowing whole milk, Anal. Chem., 90, 10641, 10.1021/acs.analchem.8b01993 · doi:10.1021/acs.analchem.8b01993
  7. Li, 2017, Calibration-free electrochemical biosensors supporting accurate molecular measurements directly in undiluted whole blood, J. Am. Chem. Soc., 139, 11207, 10.1021/jacs.7b05412 · DOI · Paper page
  8. Li, 2018, Design of DNA nanostructure-based interfacial probes for the electrochemical detection of nucleic acids directly in whole blood, Chem. Sci., 9, 979, 10.1039/C7SC04663D · DOI
  9. Swensen, 2009, Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor, J. Am. Chem. Soc., 131, 4262, 10.1021/ja806531z · doi:10.1021/ja806531z
  10. Somerson, 2017, Real-time measurement of small molecules directly in awake, ambulatory animals, Proc. Natl. Acad. Sci. USA, 114, 645, 10.1073/pnas.1613458114 · DOI · Paper page
  11. Ortega, 2018, High-precision control of plasma drug levels using feedback-controlled dosing, ACS Pharmacol. Transl. Sci., 1, 110, 10.1021/acsptsci.8b00033 · DOI
  12. Li, 2017, A biomimetic phosphatidylcholine-terminated monolayer greatly improves the in vivo performance of electrochemical aptamer-based sensors, Angew. Chem. Int. Ed., 56, 1
  13. Bissonnette, S., del Grosso, E., Simon, A.J., Plaxco, K.W., Ricci, F., and Vallée-Bélisle, A. (2020). Optimizing the specificity window of biomolecular receptors using structure-switching and allostery. ACS Sens., in press. · DOI
  14. Hubble, 2019, Sensing at Your Fingertips: Glove-based wearable chemical sensors, Electroanalysis, 31, 428, 10.1002/elan.201800743 · DOI
  15. Khan, S., Ali, S., and Bermak, A. (2019). Recent developments in printing flexible and wearable sensing electronics for healthcare applications. Sensors, 19. · DOI · Paper page
  16. Tu, J., Torrente-Rodríguez, R.M., Wang, M., and Gao, W. (2019). The era of digital health: A review of portable and wearable affinity biosensors. Adv. Funct. Mater., 1906713. · DOI · Paper page
  17. Sempionatto, 2020, Wearable chemical sensors: Emerging systems for on-body analytical chemistry, Anal. Chem., 92, 378, 10.1021/acs.analchem.9b04668 · DOI · Paper page
  18. Campuzano, 2011, Ternary monolayers as DNA recognition interfaces for direct and sensitive electrochemical detection in untreated clinical samples, Biosens. Bioelectron., 26, 3577, 10.1016/j.bios.2011.02.004 · DOI
  19. Kuralay, 2011, Highly sensitive disposable nucleic acid biosensors for direct bioelectronic detection in raw biological samples, Talanta, 85, 1330, 10.1016/j.talanta.2011.06.012 · doi:10.1016/j.talanta.2011.06.012
  20. Sempionatto, 2018, Delayed sensor activation based on transient coatings: Biofouling protection in complex biofluids, J. Am. Chem. Soc., 140, 14050, 10.1021/jacs.8b08894 · DOI
  21. Sempionatto, 2019, Direct electrochemical biosensing in gastrointestinal fluids, Anal. Bioanal. Chem., 411, 4597, 10.1007/s00216-018-1528-2 · DOI
  22. Song, 2020, Designed three-in-one peptides with anchoring, antifouling and recognizing capabilities for highly sensitive and low fouling electrochemical sensing in complex biological media, Anal. Chem., 92, 5795, 10.1021/acs.analchem.9b05299 · DOI
  23. Parolo, 2020, E-DNA scaffold sensors and the reagentless, single step, measurement of HIV-diagnostic antibodies in human serum, Microsyst. Nanoeng., 6, 13, 10.1038/s41378-019-0119-5 · DOI
  24. Liu, 2015, Detecting multiple cell-secreted cytokines from the same aptamer functionalized electrode, Biosens. Bioelectron., 64, 43, 10.1016/j.bios.2014.08.034 · DOI
  25. Zhad, 2018, Application of calcium-binding motif of E-cadherin for electrochemical detection of Pb(II), Anal. Chem., 90, 6519, 10.1021/acs.analchem.7b05458 · doi:10.1021/acs.analchem.7b05458
  26. Zhad, 2014, A Hg(II)-mediated ‘‘signal-on’’ electrochemical glutathione sensor, Chem. Commun., 50, 8385, 10.1039/c4cc03329a · doi:10.1039/c4cc03329a
  27. Campuzano, S., Pedrero, M., Yáñez-Sedeño, P., and Pingarrón, J.M. (2019). Antifouling (bio)materials for electrochemical (bio)sensing. Int. J. Mol. Sci., 20. · DOI · Paper page
  28. Cui, 2017, Mixed self-assembled aptamer and newly designed zwitterionic peptide as antifouling biosensing interface for electrochemical detection of alpha-fetoprotein, ACS Sens., 2, 490, 10.1021/acssensors.7b00103 · doi:10.1021/acssensors.7b00103
  29. Wang, 2017, Zwitterionic peptide anchored to conducting polymer PEDOT for the development of antifouling and ultrasensitive electrochemical DNA sensor, Biosens. Bioelectron., 92, 396, 10.1016/j.bios.2016.10.088 · doi:10.1016/j.bios.2016.10.088
  30. Wang, 2018, Antifouling and ultrasensitive biosensing interface based on self-assembled peptide and aptamer on macroporous gold for electrochemical detection of immunoglobulin E in serum, Anal. Bioanal. Chem., 410, 5871, 10.1007/s00216-018-1201-9 · doi:10.1007/s00216-018-1201-9
  31. Henry, 2010, Bipodal PEGylated alkanethiol for the enhanced electrochemical detection of genetic markers involved in breast cancer, Biosens. Bioelectron., 26, 1500, 10.1016/j.bios.2010.07.095 · DOI
  32. Dharuman, 2010, Ternary mixed monolayers for simultaneous DNA orientation control and surface passivation for label free DNA hybridization electrochemical sensing, Biosens. Bioelectron., 25, 2129, 10.1016/j.bios.2010.02.019 · doi:10.1016/j.bios.2010.02.019
  33. Dharuman, 2011, Sensitive label-free electrochemical DNA hybridization detection in the presence of 11-mercaptoundecanoic acid on the thiolated single strand DNA and mercaptohexanol binary mixed monolayer surface, Electrochim. Acta, 56, 8147, 10.1016/j.electacta.2011.05.115 · doi:10.1016/j.electacta.2011.05.115
  34. Campuzano, 2012, Ternary monolayer interfaces for ultrasensitive and direct bioelectronics detection of nucleic acids in complex matrices, Electroanalysis, 24, 483, 10.1002/elan.201100452 · doi:10.1002/elan.201100452
  35. Blaszykowski, 2012, Surface chemistry to minimize fouling from blood-based fluids, Chem. Soc. Rev., 41, 5599, 10.1039/c2cs35170f · DOI · Paper page
  36. Josephs, 2012, A Single-Molecule View of conformational switching of DNA tethered to a gold electrode, J. Am. Chem. Soc., 134, 10021, 10.1021/ja3010946 · DOI
  37. Halford, 2013, Rapid antimicrobial susceptibility testing by sensitive detection of precursor rRNA using a novel electrochemical biosensing platform, Antimicrob. Agents Chemother., 57, 936, 10.1128/AAC.00615-12 · doi:10.1128/aac.00615-12
  38. Goda, 2013, Thiolated 2-methacryloyloxyethyl phosphorylcholine for an antifouling biosensor platform, Chem. Commun., 49, 8683, 10.1039/c3cc44357d · DOI
  39. McQuistan, 2014, Use of thiolated oligonucleotides as anti-fouling diluents in electrochemical peptide-based sensors, Chem. Commun., 50, 4690, 10.1039/c4cc01290a · DOI · Paper page
  40. Jolly, 2015, Label-free impedimetric aptasensor with antifouling surface chemistry: A prostate specific antigen case study, Sens. Actuators B Chem., 209, 306, 10.1016/j.snb.2014.11.083 · doi:10.1016/j.snb.2014.11.083
  41. Avlonitis, 2016, Methylene blue not ferrocene: Optimal reporters for electrochemical detection of protease activity, Biosens. Bioelectron., 84, 82, 10.1016/j.bios.2015.11.088 · DOI
  42. Hu, 2016, Antifouling Zwitterionic Coating via Electrochemically Mediated Atom Transfer Radical Polymerization on Enzyme-Based Glucose Sensors for Long-Time Stability in 37 °C Serum, Langmuir, 32, 11763, 10.1021/acs.langmuir.6b03016 · DOI
  43. Gao, 2017, A multiplex electrochemical biosensor for bloodstream infection diagnosis, SLAS Technol., 22, 466, 10.1177/2211068216651232 · DOI
  44. Altobelli, 2017, Integrated biosensor assay for rapid uropathogen identification and phenotypic antimicrobial susceptibility testing, Eur. Urol. Focus, 3, 293, 10.1016/j.euf.2015.12.010 · DOI
  45. Ding, 2017, Rapid and label-free detection of interferon gamma via an electrochemical aptasensor comprising a ternary surface monolayer on a gold interdigitated electrode array, ACS Sens., 2, 210, 10.1021/acssensors.6b00581 · DOI
  46. 2017, Thioaromatic DNA monolayers for target-amplification-free electrochemical sensing of environmental pathogenic bacteria, Biosens. Bioelectron., 92, 162, 10.1016/j.bios.2017.02.017 · DOI
  47. 2018, Understanding the factors affecting the analytical performance of sandwich-hybridization genosensors on gold electrodes, Electroanalysis, 30, 1229, 10.1002/elan.201800049 · doi:10.1002/elan.201800049
  48. Staderini, 2018, Electrochemical sensing of human neutrophil elastase and polymorphonuclear neutrophil activity, Biosens. Bioelectron., 119, 209, 10.1016/j.bios.2018.08.013 · DOI
  49. Staderini, 2018, Effect of spacer length on the performance of peptide-based electrochemical biosensors for protease detection, Sens. Actuators B Chem., 255, 3040, 10.1016/j.snb.2017.09.128 · DOI
  50. Boozer, 2006, Controlling DNA orientation on mixed ssDNA/OEG SAMs, Langmuir, 22, 4694, 10.1021/la052908e · doi:10.1021/la052908e
  51. Dharuman, 2008, Label-free electrochemical DNA hybridization discrimination effects at the binary and ternary mixed monolayers of single stranded DNA/diluent/s in presence of cationic intercalators, Biosens. Bioelectron., 23, 1250, 10.1016/j.bios.2007.11.015 · DOI
  52. Wu, 2010, Ternary surface monolayers for ultrasensitive (zeptomole) amperometric detection of nucleic acid hybridization without signal amplification, Anal. Chem., 82, 8830, 10.1021/ac101474k · doi:10.1021/ac101474k
  53. Goodman, 2004, The single-step synthesis of a DNA tetrahedron, Chem. Commun., 12, 1372, 10.1039/b402293a · DOI · Paper page
  54. Pei, 2010, A DNA Nanostructure-based biomolecular probe carrier platform for electrochemical biosensing, Adv. Mater., 22, 4754, 10.1002/adma.201002767 · DOI · Paper page
  55. Lin, 2016, Electrochemical detection of nucleic acids, proteins, small molecules and cells using a DNA-nanostructure-based universal biosensing platform, Nat. Protoc., 11, 1244, 10.1038/nprot.2016.071 · DOI · Paper page
  56. Dong, 2015, Electrochemical DNA biosensor based on a tetrahedral nanostructure probe for the detection of Avian Influenza A (H7N9) virus, ACS Appl. Mater. Interfaces, 5, 8834, 10.1021/acsami.5b01438 · DOI · Paper page
  57. Lubin, 2010, Folding-based electrochemical biosensors: The case for responsive nucleic acid architectures, Acc. Chem. Res., 43, 496, 10.1021/ar900165x · DOI · Paper page
  58. Campuzano, 2019, Reagentless and reusable electrochemical affinity biosensors for near real-time and/or continuous operation. Advances and prospects, Curr. Opin. Electrochem., 16, 35, 10.1016/j.coelec.2019.03.006 · DOI
  59. Plaxco, 2011, Switch-based biosensors: A new approach towards real-time, in vivo molecular detection, Trends Biotechnol., 29, 1, 10.1016/j.tibtech.2010.10.005 · DOI · Paper page
  60. Scida, 2020, From the beaker to the body: Translational challenges for electrochemical, aptamer-based sensors, Anal. Methods, 12, 1288, 10.1039/D0AY00026D · DOI · Paper page
  61. Ranallo, 2015, A modular, DNA-based beacon for single-step fluorescence detection of antibodies and other proteins, Angew. Chem. Int. Ed., 54, 13214, 10.1002/anie.201505179 · DOI
  62. White, 2012, Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies, Anal. Chem., 84, 1098, 10.1021/ac202757c · DOI
  63. Ferguson, 2013, Real-time, aptamer-based tracking of circulating therapeutic agents in living animals, Sci. Transl. Med., 5, 213ra165, 10.1126/scitranslmed.3007095 · DOI · Paper page
  64. Kang, 2017, New architecture for reagentless, protein-based electrochemical biosensors, J. Am. Chem. Soc., 139, 12113, 10.1021/jacs.7b05953 · DOI
  65. Xiao, 2006, Single-step electronic detection of femtomolar DNA by target-induced strand displacement in an electrode-bound duplex, Proc. Natl. Acad. Sci. USA, 103, 16677, 10.1073/pnas.0607693103 · DOI · Paper page
  66. Wang, 2016, Facile construction of a highly sensitive DNA biosensor by in-situ assembly of electro-active tags on hairpin-structured probe fragment, Sci. Rep., 6, 22441, 10.1038/srep22441 · doi:10.1038/srep22441
  67. Zaitouna, 2014, An electrochemical peptide-based Ara h 2 antibody sensor fabricated on a nickel(II)-nitriloacetic acid self-assembled monolayer using a His-tagged peptide, Anal. Chim. Acta, 828, 85, 10.1016/j.aca.2014.04.033 · doi:10.1016/j.aca.2014.04.033
  68. Mayer, 2018, Effects of redox label location on the performance of an electrochemical aptamer-based tumor necrosis factor-alpha sensor, Talanta, 189, 585, 10.1016/j.talanta.2018.07.055 · doi:10.1016/j.talanta.2018.07.055
  69. Lai, 2016, Comparison of the signaling and stability of electrochemical DNA sensors fabricated from 6- or 11-carbon self-assembled monolayers, Langmuir, 22, 10796, 10.1021/la0611817 · doi:10.1021/la0611817
  70. Baker, 2006, An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological Fluids, J. Am. Chem. Soc., 128, 3138, 10.1021/ja056957p · doi:10.1021/ja056957p
  71. Parate, 2019, Electrochemical cotinine sensing with a molecularly imprinted polymer on a graphene-platinum nanoparticle modified carbon electrode towards cigarette smoke exposure monitoring, Sens. Actuators B Chem., 287, 165, 10.1016/j.snb.2019.02.032 · DOI
  72. Wang, 2019, Direct, selective and ultrasensitive electrochemical biosensing of methyl parathion in vegetables using Burkholderia cepacia lipase@MOF nanofibersbased biosensor, Talanta, 197, 356, 10.1016/j.talanta.2019.01.052 · doi:10.1016/j.talanta.2019.01.052
  73. Du, 2014, Reagentless, ratiometric electrochemical DNA sensors with improved robustness and reproducibility, Anal. Chem., 86, 8010, 10.1021/ac5025254 · DOI · Paper page

Metadata

Authors
Campuzano, S., Pedrero, M., Gamella, M., Serafín, V., Yáñez-Sedeño, P., & Pingarrón, J. M.
Venue
Sensors
Publisher
MDPI AG
Published
2020-06-16
Volume
20
Issue
12
Pages
3376
ISSN
1424-8220
Cited by
83
References
2
Language
en
Funders
  • Ministerio de Economía, Industria y Competitividad, Gobierno de España (CTQ2015-64402-C2-1-R)
  • Ministerio de Ciencia, Innovación y Universidades (RTI2018-096135-B-I00)
  • Comunidad de Madrid (S2018/NMT-4349)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices. https://app.cochat.ai/papers/10.3390/s20123376
The paper
Campuzano, S., Pedrero, M., Gamella, M., Serafín, V., Yáñez-Sedeño, P., & Pingarrón, J. M. (2020). Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices. Sensors. https://doi.org/10.3390/s20123376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.