Silicon Wafer-Based Platinum Microelectrode Array Biosensor for Near Real-Time Measurement of Glutamate in Vivo
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Using Micro-Electro-Mechanical-Systems (MEMS) technologies, we have developed silicon wafer-based platinum microelectrode arrays (MEAs) modified with glutamate oxidase (GluOx) for electroenzymatic detection of glutamate in vivo. These MEAs were designed to have optimal spatial resolution for in vivo recordings. Selective detection of glutamate in the presence of the electroactive interferents, dopamine and ascorbic acid, was attained by deposition of polypyrrole and Nafion. The sensors responded to glutamate with a limit of detection under 1μM and a sub-1-second response time in solution. In addition to extensive in vitro characterization, the utility of these MEA glutamate biosensors was also established in vivo. In the anesthetized rat, these MEA glutamate biosensors were used for detection of cortically-evoked glutamate release in the ventral striatum. The MEA biosensors also were applied to the detection of stress-induced glutamate release in the dorsal striatum of the freely-moving rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Danbolt, N. C. (2001) · Progress in Neurobiology · doi:10.1016/s0301-0082(00)00067-8 · Cited by 4,227
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113 · cited 1×
“Behavior, especially motivated behavior, can change within seconds of stimuli presentation [7], and the 5-10 m in temporal resolution of microdialysis [6] timeaverages these fast changes [7-10].”
BackgroundReal-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats
Heien, M. L. A. V., Khan, A. S., Ariansen, J. L., Cheer, J. F., Phillips, P. E. M., Wassum, K. M., & Wightman, R. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504657102 · Cited by 482 · cited 2×
“Behavior, especially motivated behavior, can change within seconds of stimuli presentation [7], and the 5-10 m in temporal resolution of microdialysis [6] timeaverages these fast changes [7-10].”
BackgroundMethodSelf-citationRobinson, D. L., Heien, M. L. A. V., & Wightman, R. M. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-23-10477.2002 · Cited by 290
Functional Specificity of Ventral Striatal Compartments in Appetitive Behaviors
KELLEY, A. E. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09262.x · Cited by 198
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Using Physical Organic Chemistry To Shape the Course of Electrochemical Reactions
Moeller, K. D. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00656 · Cited by 705
Review of recent advances in analytical techniques for the determination of neurotransmitters
Perry, M., Li, Q., & Kennedy, R. T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.038 · Cited by 367
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Chung, J. E., Joo, H. R., Fan, J. L., Liu, D. F., Barnett, A. H., Chen, S., Geaghan-Breiner, C., Karlsson, M. P., Karlsson, M., Lee, K. Y., et al. (2019) · Neuron · doi:10.1016/j.neuron.2018.11.002 · Cited by 342
Self-citationChotibut, T., Davis, R. W., Arnold, J. C., Frenchek, Z., Gurwara, S., Bondada, V., Geddes, J. W., & Salvatore, M. F. (2014) · Molecular Neurobiology · doi:10.1007/s12035-013-8598-0 · Cited by 86
“The reuptake time was chosen to be as close as technically and practically possible to the reuptake time of glutamate observed in vivo, which occurs within 10 s [59, 60].”
Chotibut, T., Meadows, S., Kasanga, E. A., McInnis, T., Cantu, M. A., Bishop, C., & Salvatore, M. F. (2017) · Movement Disorders · doi:10.1002/mds.27077 · Cited by 56
In Vivo Glutamate Sensing inside the Mouse Brain with Perovskite Nickelate–Nafion Heterostructures
Sun, Y., Nguyen, T. N. H., Anderson, A., Cheng, X., Gage, T. E., Lim, J., Zhang, Z., Zhou, H., Rodolakis, F., Zhang, Z., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c02826 · Cited by 45
Metadata
- Authors
- Wassum, K. M., Tolosa, V. M., Wang, J., Walker, E., Monbouquette, H. G., & Maidment, N. T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-08-27
- Volume
- 8
- Issue
- 8
- Pages
- 5023-5036
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2145690375
- Cited by
- 130
- References
- 5
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.