The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits
Open accessAbstract
Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS), cavity ringdown spectroscopy (CRDS), integrated cavity output spectroscopy (ICOS), cavity enhanced absorption spectroscopy (CEAS), cavity leak-out spectroscopy (CALOS), photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS). Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
O’Keefe, A., & Deacon, D. A. G. (1988) · Review of Scientific Instruments · doi:10.1063/1.1139895 · Cited by 1,597
The HITRAN molecular spectroscopic database: edition of 2000 including updates through 2001
Rothman, L. S., Barbe, A., Chris Benner, D., Brown, L. R., Camy-Peyret, C., Carleer, M. R., Chance, K., Clerbaux, C., Dana, V., Devi, V. M., et al. (2003) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(03)00146-8 · Cited by 1,174
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
CAMPYLOBACTER PYLORI DETECTED NONINVASIVELY BY THE 13C-UREA BREATH TEST
Graham, D., Evans, D., Alpert, L., Klein, P., Evans, D., Opekun, A., & Boutton, T. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92145-3 · Cited by 711
Di Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., D'Arcangelo, G., Roscioni, C., Finazzi-Agrò, A., & D'Amico, A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00086-1 · Cited by 663
Induction of heme oxygenase: a general response to oxidant stress in cultured mammalian cells.
Applegate, L. A., Lüscher, P., & Tyrrell, R. M. (1991) · PubMed · Cited by 629
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Cited by
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Recent advances in wearable sensors for animal health management
Neethirajan, S. (2017) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.11.004 · Cited by 502
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Guo, H., Herkommer, C., Billat, A., Grassani, D., Zhang, C., Pfeiffer, M. H. P., Weng, W., Brès, C.-S., & Kippenberg, T. J. (2018) · Nature Photonics · doi:10.1038/s41566-018-0144-1 · Cited by 332
Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Self-citationBreath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
On-Line Analysis of Exhaled Breath: Focus Review
Bruderer, T., Gaisl, T., Gaugg, M. T., Nowak, N., Streckenbach, B., Müller, S., Moeller, A., Kohler, M., & Zenobi, R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00005 · Cited by 278
Silicon Nanowire Sensors Enable Diagnosis of Patients via Exhaled Breath
Shehada, N., Cancilla, J. C., Torrecilla, J. S., Pariente, E. S., Brönstrup, G., Christiansen, S., Johnson, D. W., Leja, M., Davies, M. P. A., Liran, O., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b03127 · Cited by 227
Metadata
- Authors
- Wang, C., & Sahay, P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2009-10-19
- Volume
- 9
- Issue
- 10
- Pages
- 8230-8262
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2056132214
- Cited by
- 596
- References
- 86
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.