Dual-energy CT-based Assessment of the Trabecular Bone in Vertebrae

Kirschner, M., Becker, M., Erdt, M., Kafchitsas, K., Khan, M. F., Wesarg, S. · 2012 · Methods of Information in Medicine
Cited by 63

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: Background: Osteoporosis can cause severe fractures of bone structures. One important indicator for pathology is a lowered bone mineral density (BMD) – conventionally assessed by dual-energy X-ray absorptiometry (DXA). Dual-energy CT (DECT) – being an alternative that is increasingly used in the clinics – allows the computation of the spatial BMD distribution. Objectives: Using DECT, the trabecular bone of vertebrae is examined. Several analysis methods for revealing the bone density distribution as well as appropriate visualization methods for detecting regions of lowered BMD are needed for computer-assisted diagnosis (CAD) of osteoporosis. The hypothesis that DECT is better suited than DXA for the computation of local BMD is investigated. Methods: Building on a model of the interaction of X-rays with bone tissue, novel methods for assessing the spatial structure of the trabecular bone are presented. CAD of DECT image data is facilitated by segmenting the regions of interest interactively and with an Active Shape Model, respectively. The barycentric space of fractional volumes is introduced as a novel means for analyzing bone constitution. For 29 cadaver specimens, DECT as well as DXA has been examined. BMD values derived from both modalities are compared to local force measurements. In addition, clinical data from two patients who underwent DECT scanning for a different reason is analyzed retrospectively. Results: A novel automated delineation method for vertebrae has been successfully applied to DECT data sets. It is shown that localized BMD measurements based on DECT show a stronger linear correlation (R2 = 0.8242, linear regression) to local force measurements than density values derived from DXA (R2 = 0.4815). Conclusions: DECT based BMD assessment is a method to extend the usage of increasingly acquired DECT image data. The developed DECT based analysis methods in conjunction with the visualization provide more detailed information for both, the radiologist and the orthopedist, compared to standard DXA based analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3414/me11-02-0034

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Kirschner, M., Becker, M., Erdt, M., Kafchitsas, K., Khan, M. F., & Wesarg, S.
Venue
Methods of Information in Medicine
Published
2012
Volume
51
Issue
05
Pages
398-405
ISSN
  • 0026-1270 (ISSN-L)
  • 2511-705X
OpenAlex
W2053081362
Cited by
63
References
2
FWCI
1.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.