RETRACTED ARTICLE: Eye tracking: empirical foundations for a minimal reporting guideline
Open accessThe DOI matches its Crossref record; 337 of the 337 references it cites were found in a registry or an index.
Abstract
In this paper, we present a review of how the various aspects of any study using an eye tracker (such as the instrument, methodology, environment, participant, etc.) affect the quality of the recorded eye-tracking data and the obtained eye-movement and gaze measures. We take this review to represent the empirical foundation for reporting guidelines of any study involving an eye tracker. We compare this empirical foundation to five existing reporting guidelines and to a database of 207 published eye-tracking studies. We find that reporting guidelines vary substantially and do not match with actual reporting practices. We end by deriving a minimal, flexible reporting guideline based on empirical research (Section “An empirically based minimal reporting guideline”).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893 · cited 1×
“Holmqvist (2015) used a RANSAC fit (Fischler & Bolles, 1981) followed by a linear shift to calibrate the DPI.”
MethodEstimating the reproducibility of psychological science
Open Science Collaboration (2015) · Science · doi:10.1126/science.aac4716 · Cited by 8,515 · cited 1×
“A well-known study on replicability estimated that a mere one third of the findings in psychological science are replicable, qualifying this as a ‘replication crisis’ (Open Science Collaboration, 2015).”
BackgroundEye movements in reading and information processing: 20 years of research
Rayner, K. (1998) · Psychological Bulletin · doi:10.1037/0033-2909.124.3.372 · Cited by 7,979
Yarbus, A. L. (1967) · doi:10.1007/978-1-4899-5379-7 · Cited by 3,304
Eye Tracking: A comprehensive guide to methods and measures
Holmqvist, K., Nyström, M., Andersson, R., Dewhurst, R. J., Jarodzka, H. M., & van de Weijer, J. (2015) · Lund University Publications (Lund University) · Cited by 2,919
Self-citationRegularly Occurring Periods of Eye Motility, and Concomitant Phenomena, During Sleep
Aserinsky, E., & Kleitman, N. (1953) · Science · doi:10.1126/science.118.3062.273 · Cited by 2,475 · cited 1×
“One specific advantage of EOGs is that they can be used when the eyes are closed, for instance to study REM sleep (Aserinsky & Kleitman, 1953).”
BackgroundEye Tracking Methodology: Theory and Practice
Duchowski, A. T. (2003) · Springer eBooks · doi:10.1007/978-1-4471-3750-4 · Cited by 2,242 · cited 1×
“Notice that pattern matching filters, such as those described by Stampe (1993, p. 138, known as the heuristic filter in EyeLink and SMI trackers) and Duchowski (2007) amplify parts of the gaze signal with a similar appearance to the filter pattern, while attenuating other portions.”
MethodIdentifying fixations and saccades in eye-tracking protocols
Salvucci, D. D., & Goldberg, J. H. (2000) · Proceedings of the symposium on Eye tracking research & applications - ETRA '00 · doi:10.1145/355017.355028 · Cited by 2,203 · cited 2×
“In fact, several algorithm comparisons have reported large differences in fixation and saccade measures between algorithms (Andersson et al., 2017; Benjamins et al., 2018; Dalveren & Cagiltay, 2019; Komogortsev et al., 2010; Salvucci & Goldberg, 2000; Stuart et al., 2019).”
BackgroundMethodKlin, A., Jones, W., Schultz, R., Volkmar, F., & Cohen, D. (2002) · Archives of General Psychiatry · doi:10.1001/archpsyc.59.9.809 · Cited by 2,120 · cited 1×
“One often-reported finding is differences in gaze behaviour to the eyes of a face between individuals with and without an ASD diagnosis (e.g. Dalton et al., 2005; Jones et al., 2008, 2013; Klin et al., 2002; Rice et al., 2012).”
BackgroundSaccade target selection and object recognition: Evidence for a common attentional mechanism
Deubel, H., & Schneider, W. X. (1996) · Vision Research · doi:10.1016/0042-6989(95)00294-4 · Cited by 1,979 · cited 1×
“The DPI used to be the main workhorse of many psychology laboratories and features in many influential publications such as Frazier and Rayner (1982) and Deubel and Schneider (1996).”
Background
Cited by
Molenaar, I., Mooij, S. D., Azevedo, R., Bannert, M., Järvelä, S., & Gašević, D. (2023) · Computers in Human Behavior · doi:10.1016/j.chb.2022.107540 · Cited by 217
Metadata
- Authors
- Holmqvist, K., Örbom, S. L., Hooge, I. T. C., Niehorster, D. C., Alexander, R. G., Andersson, R., Benjamins, J. S., Blignaut, P., Brouwer, A.-M., Chuang, L. L., Dalrymple, K. A., Drieghe, D., Dunn, M. J., Ettinger, U., Fiedler, S., Foulsham, T., van der Geest, J. N., Hansen, D. W., Hutton, S. B., Kasneci, E., Kingstone, A., Knox, P. C., Kok, E. M., Lee, H., Lee, J. Y., Leppänen, J. M., Macknik, S., Majaranta, P., Martinez-Conde, S., Nuthmann, A., Nyström, M., Orquin, J. L., Otero-Millan, J., Park, S. Y., Popelka, S., Proudlock, F., Renkewitz, F., Roorda, A., Schulte-Mecklenbeck, M., Sharif, B., Shic, F., Shovman, M., Thomas, M. G., Venrooij, W., Zemblys, R., & Hessels, R. S.
- Venue
- Behavior Research Methods
- Published
- 2022-04-06
- Volume
- 55
- Issue
- 1
- Pages
- 364-416
- ISSN
- 1554-351X (ISSN-L)
- 1554-3528
- OpenAlex
- W4225749806
- Cited by
- 167
- References
- 337
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Status
- Retracted
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.