A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: The aim of this study was to design and evaluate in the laboratory a new intraocular lena (IOL) intended to provide superior octtlar optical quality by reducing spherical aberration. METHODS: Corneal topography measurements were performed on 71 cataract patients using an Orbscan I. The measured corneal surface shapes were used to determine the wavefront aberration of each cornea. A model cornea was then designed to reproduce the measured average spherical aberration. This model cornea was used to design IOLs having a fixed amount of negative spherical aberration that partially compensates for the average positive spherical aberration of the cornea. Theoretical and physical eye models were used to assess the expected improvement in optical quality of an eye implanted with this lens. RESULTS: Measurements of optical quality provided evidence that if this modified prolate IOL was centered within 0.4 mm and tilted less than 7 degrees, it would exceed the optical performance of a conventional spherical IOL. This improvement occurred without an apparent loss in depth of focus. CONCLUSION: A new IOL with a prolate anterior surface, designed to partially compensate for the average spherical aberration of the cornea, is intended to improve the ocular optical quality of Pseudophakie patients. [J Refract Surg 2002;18: 683-691]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Presbyopia and the optical changes in the human crystalline lens with age
Glasser, A., & Campbell, M. C. W. (1998) · Vision Research · doi:10.1016/s0042-6989(97)00102-8 · Cited by 601
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Self-citationCompensation of corneal aberrations by the internal optics in the human eye
Artal, P., Guirao, A., Berrio, E., & Williams, D. R. (2001) · Journal of Vision · doi:10.1167/1.1.1 · Cited by 434
Glasser, A., & C.W. Campbell, M. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00283-1 · Cited by 425
The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox
Dubbelman, M., & Van der Heijde, G. L. (2001) · Vision Research · doi:10.1016/s0042-6989(01)00057-8 · Cited by 354
Optical aberrations of the human cornea as a function of age
Guirao, A., Redondo, M., & Artal, P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.001697 · Cited by 303
Average optical performance of the human eye as a function of age in a normal population.
Guirao, A., González, C., Redondo, M., Geraghty, E., Norrby, S., & Artal, P. (1999) · PubMed · Cited by 274
Corneal wave aberration from videokeratography: accuracy and limitations of the procedure
Guirao, A., & Artal, P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000955 · Cited by 172
Prospective Randomized Trial of an Anterior Surface Modified Prolate Intraocular Lens
Packer, M., Fine, I. H., Hoffman, R. S., & Piers, P. A. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20021101-05 · Cited by 172
Self-citationDesign of aspheric intraocular lenses
Atchison, D. A. (1991) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1991.tb00213.x · Cited by 118
Cited by
Cataract in the Adult Eye Preferred Practice Pattern®
Olson, R. J., Braga-Mele, R., Chen, S. H., Miller, K. M., Pineda, R., Tweeten, J. P., & Musch, D. C. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.09.027 · Cited by 277
Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses
Marcos, S., Barbero, S., & Jiménez-Alfaro, I. (2005) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20050501-05 · Cited by 213
Optical performance of 3 intraocular lens designs in the presence of decentration
Altmann, G. E., Nichamin, L. D., Lane, S. S., & Pepose, J. S. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.024 · Cited by 210
Eppig, T., Scholz, K., Löffler, A., Meßner, A., & Langenbucher, A. (2009) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2009.01.034 · Cited by 185
“andHolladay et al.(6) TheMTF values of the 2 aberration-free IOLs (MC6125AS and SofPort AO) showed less decentration dependency, and the MTF of the spherical IOL was independent of decentration.”
BackgroundCataract in the Adult Eye Preferred Practice Pattern®
Miller, K. M., Oetting, T. A., Tweeten, J. P., Carter, K., Lee, B. S., Lin, S., Nanji, A. A., Shorstein, N. H., & Musch, D. C. (2022) · Ophthalmology · doi:10.1016/j.ophtha.2021.10.006 · Cited by 182
Metadata
- Authors
- Holladay, J. T., Piers, P. A., Koranyi, G., van der Mooren, M., & Norrby, N. E. S.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2002-11
- Volume
- 18
- Issue
- 6
- Pages
- 683-691
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2161036079
- Cited by
- 560
- References
- 11
- FWCI
- 13.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.