Empatica E3 - A wearable wireless multi-sensor device for real-time computerized biofeedback and data acquisition
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The Empatica E3 is a wearable wireless multi- sensor device for real-time computerized biofeedback and data acquisition. The E3 has four embedded sensors: photoplethysmo- graph (PPG), electrodermal activity (EDA), 3-axis accelerometer, and temperature. It is small, light and comfortable and it is su
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · cited 1×
“The inter-beat interval output allows the researcher to conduct heart rate variability analysis [10], which is important in estimating vagal tone and parasympathetic nervous system activity.”
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 1×
“The E3 is equipped with a PPG sensor that illuminates the skin and measures the light reflected [8].”
BackgroundPublication Recommendations for Electrodermal Measurements
Fowles, D. C., Christie, M. J., Edelberg, R., GRINGS, W. W., Lykken, D. T., & Venables, P. H. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb03024.x · Cited by 1,699
Boucsein, W. (1992) · doi:10.1007/978-1-4757-5093-5 · Cited by 818
A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038487 · Cited by 693 · cited 1×
“, fingers, palm, and wrist) [4], although in most cases the EDA measures made at the wrist are correlated with the traditional placements [5], [6].”
BackgroundSelf-citationEmotional sweating across the body: Comparing 16 different skin conductance measurement locations
van Dooren, M., de Vries, J. J. G. (.-J., & Janssen, J. H. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2012.01.020 · Cited by 411 · cited 1×
“, fingers, palm, and wrist) [4], although in most cases the EDA measures made at the wrist are correlated with the traditional placements [5], [6].”
BackgroundMultiple Arousal Theory and Daily-Life Electrodermal Activity Asymmetry
Picard, R. W., Fedor, S., & Ayzenberg, Y. (2016) · Emotion Review · doi:10.1177/1754073914565517 · Cited by 287 · cited 2×
“However, in some cases, depending on which neurological system is activated in the brain, different values of EDA might be measured from left and right wrist [7].”
BackgroundSelf-citationLee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 154 · cited 1×
“Standard techniques for artifact removal in wrist-worn PPG systems make use of accelerometers [1], [9].”
MethodA Major Effect of Recording Site on Measurement of Electrodermal Activity
Scerbo, A. S., Freedman, L. W., Raine, A., Dawson, M. E., & Venables, P. H. (1992) · Psychophysiology · doi:10.1111/j.1469-8986.1992.tb01693.x · Cited by 117 · cited 1×
“, fingers, palm, and wrist) [4], although in most cases the EDA measures made at the wrist are correlated with the traditional placements [5], [6].”
BackgroundWrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation
Renevey, P., Vetter, R., Krauss, J., Celka, P., & Depeursinge, Y. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1017437 · Cited by 63 · cited 2×
“This technique is different from the common technique that exploits a single wavelength together with accelerometer information [1].”
Method
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Monitoring stress with a wrist device using context
Gjoreski, M., Luštrek, M., Gams, M., & Gjoreski, H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.08.006 · Cited by 352
Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272
Schuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., Popma, A., & Otten, R. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01648-w · Cited by 210
Real-Time Measurement of Tourists’ Objective and Subjective Emotions in Time and Space
Shoval, N., Schvimer, Y., & Tamir, M. (2018) · Journal of Travel Research · doi:10.1177/0047287517691155 · Cited by 189
“The device has been clinically tested and shown high validity and accuracy (Garbarino et al. 2014; Empatica 2014).”
Method
Metadata
- Authors
- Garbarino, M., Lai, M., Tognetti, S., Picard, R., & Bender, D.
- Venue
- Proceedings of the 4th International Conference on Wireless Mobile Communication and Healthcare - "Transforming healthcare through innovations in mobile and wireless technologies"
- Publisher
- ICST
- Published
- 2014
- OpenAlex
- W4250910818
- Cited by
- 215
- References
- 10
- FWCI
- 26.35
- Type
- conference paper
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.