The DOI matches its Crossref record; 66 of the 68 references it cites were found in a registry or an index.
Continuous Glucose Monitoring: A Consensus Conference of the American Association of Clinical Endocrinologists and American College of Endocrinology
Open accessAbstract
Objective/methods Barriers to continuous glucose monitoring (CGM) use continue to hamper adoption of this valuable technology for the management of diabetes. The American Association of Clinical Endocrinologists and the American College of Endocrinology convened a public consensus conference February 20, 2016, to review available CGM data and propose strategies for expanding CGM access.Results Conference participants agreed that evidence supports the benefits of CGM in type 1 diabetes and that these benefits are likely to apply whenever intensive insulin therapy is used, regardless of diabetes type. CGM is likely to reduce healthcare resource utilization for acute and chronic complications, although real-world analyses are needed to confirm potential cost savings and quality of life improvements. Ongoing technological advances have improved CGM accuracy and usability, but more innovations in human factors, data delivery, reporting, and interpretation are needed to foster expanded use. The development of a standardized data report using similar metrics across all devices would facilitate clinician and patient understanding and utilization of CGM. Expanded CGM coverage by government and private payers is an urgent need.Conclusion CGM improves glycemic control, reduces hypoglycemia, and may reduce overall costs of diabetes management. Expanding CGM coverage and utilization is likely to improve the health outcomes of people with diabetes.Abbreviations A1C = glycated hemoglobin AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology ASPIRE = Automation to Simulate Pancreatic Insulin Response CGM = continuous glucose monitoring HRQOL = health-related quality of life ICER = incremental cost-effectiveness ratio JDRF = Juvenile Diabetes Research Foundation MARD = mean absolute relative difference MDI = multiple daily injections QALY = quality-adjusted life years RCT = randomized, controlled trial SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR = Sensor-Augmented Pump Therapy for A1C Reduction T1D = type 1 diabetes T2D = type 2 diabetes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In many countries, the benefits and utility of CGM are now recognized by national and international medical organizations for individuals with insulin-requiring diabetes and/or those at risk for hypoglycemia (16-21).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [17]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Hyperglycemic crises in adult patients with diabetes
Kitabchi, A. E., Umpierrez, G. E., Miles, J. M., & Fisher, J. N. (2009) · Diabetes Care · doi:10.2337/dc09-9032 · Cited by 2,062
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · cited 1×
“The number of users in the T1D Exchange clinic registry has more than doubled to 15% in 2016 (1,25,26), and observational data collected in 2014-2015 from the T1D Exchange clinic registry support the benefits of newer devices.”
BackgroundEffectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Self-citationBraithwaite, R. S., Meltzer, D. O., King, J. T., Leslie, D., & Roberts, M. S. (2008) · Medical Care · doi:10.1097/mlr.0b013e31815c31a7 · Cited by 579
Diabetic emergencies - ketoacidosis, hyperglycaemic hyperosmolar state and hypoglycaemia
Umpierrez, G., & Korytkowski, M. (2016) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2016.15 · Cited by 563 · cited 1×
“is $218 billion per year (43); hospitalizations for hypoglycemic and hyperglycemic crises may account for up to $5 billion, based on an estimated cost of approximately $17,500 per hospitalization (44-47).”
BackgroundYeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Flagged first, then by citations
2 of the 68 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Miller, 2016, Continuous glucose monitoring in T1D patients using injections of insulin: a report from the T1D Exchange clinic registry, Diabetes Technol Ther, 18, A
Cited by
Sorted by citations
Items 101–195 of 195
Advances in glucose monitoring: Improving diabetes management through evidence-based medicine
Mazze, R. S. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.03.001 · Cited by 12
May, S. G., Huber, C., Roach, M., Shafrin, J. T., Aubry, W. M., Lakdawalla, D. N., Kane, J. M., & Forma, F. M. (2021) · Journal of Medical Internet Research · doi:10.2196/18119 · Cited by 12
Fonseca, V. A., & Grunberger, G. (2017) · Endocrine Practice · doi:10.4158/1934-2403-23.5.629 · Cited by 12
Virtual visits and the use of continuous glucose monitoring for diabetes care in the era of COVID-19
UNDERWOOD, P. C., Hibben, J., Gibson, J. M., & DiNardo, M. M. (2021) · Journal of the American Association of Nurse Practitioners · doi:10.1097/jxx.0000000000000659 · Cited by 13
Nemlekar, P. M., Hannah, K. L., & Norman, G. J. (2023) · Clinical Diabetes · doi:10.2337/cd22-0080 · Cited by 10
The role of technology in the care of diabetes mellitus in pregnancy: an expert review
Thayer, S. M., Williams, K. J., & Lawlor, M. L. (2023) · AJOG Global Reports · doi:10.1016/j.xagr.2023.100245 · Cited by 12
Understanding Reflection Needs for Personal Health Data in Diabetes
Prioleau, T., Sabharwal, A., & Vasudevan, M. M. (2020) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3421937.3421972 · Cited by 10
Svensson, C. H., Henriksen, M. M., Thorsteinsson, B., & Pedersen‐Bjergaard, U. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0216 · Cited by 10
Assessing Glycemic Control Using CGM for Women with Diabetes in Pregnancy
O’Malley, G., Wang, A., OGYAADU, S. J., & Levy, C. J. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01415-2 · Cited by 10
Olsen, M. T., Pedersen‐Bjergaard, U., Hjejle, S., Rasmussen, L. M., Klarskov, C. K., Lindegaard, B., Andersen, J. A., Gottlieb, H., Lunding, S., Hansen, K. B., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251331628 · Cited by 9
Continuous Glucose Monitoring for Prediabetes: Roles, Evidence, and Gaps
Zahalka, S. J., Aktürk, H. K., Galindo, R. J., Shah, V. N., & Wang, C. C. L. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.05.742 · Cited by 17
Olsen, M. T., Hjejle, S., Rasmussen, L. M., Klarskov, C. K., Lindegaard, B., Andersen, J. A., Gottlieb, H., Lunding, S., Hansen, K. B., Pedersen‐Bjergaard, U., et al. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16297 · Cited by 8
Lipska, K. J., Oladele, C., Zawack, K., Gulanski, B., Mutalik, P., Reaven, P. D., Lynch, J. A., Lee, K. M., Shih, M., Lee, J. S., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0152 · Cited by 8
Continuous glucose monitoring in pregnant women with type 1 diabetes
Garg, S. K., & Polsky, S. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32449-2 · Cited by 8
Dağdelen, S., Deyneli, O., Dınççağ, N., ILKOVA, H. M., SİVA, Z. O., Yetkin, İ., & Yilmaz, T. M. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.663222 · Cited by 8
New Medications for the Treatment of Diabetes
Garg, S. K., Rewers, A. H., & Aktürk, H. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.2512 · Cited by 8
Stability, Accuracy, and Risk Assessment of a Novel Subcutaneous Glucose Sensor
Hughes, J., Welsh, J. B., Bhavaraju, N. C., Vanslyke, S., & Balo, A. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0072 · Cited by 8
Toyoshima, M. T. K., Cukier, P., de Souza, A. B. C., Pereira, J. C., Hoff, A. O., & Nery, M. (2022) · Einstein (São Paulo) · doi:10.31744/einstein_journal/2022ao8031 · Cited by 9
Deeb, A., Muammar, T., Alsaffar, H., Sedaghat, S., Hassani, N. A., Odeh, R., Alkhayyat, H., Sinani, A. A., Attia, N. A., Adhami, S., et al. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108671 · Cited by 7
Nimri, R., Murray, N., Ochs, A., Pinsker, J. E., & Dassau, E. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.2504 · Cited by 8
Triki, N., Yekutiel, N., Levi, L., & Azuri, J. (2021) · Diabetic Medicine · doi:10.1111/dme.14518 · Cited by 7
Use of continuous glucose monitoring to improve glycemic management: A clinician's guide
Schumacher, C., Isaacs, D. M., Collier, I. A., & Klinkebiel, D. (2020) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1295 · Cited by 7
O’Malley, G., Arumugam, D., OGYAADU, S. J., Levister, C. M., Nosova, E. V., Vieira, L., & Levy, C. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221134544 · Cited by 6
Diabetes technology: A primer highlighting the role of the pharmacist
Hess, R., Schumacher, C., Whitley, H. P., Reece, S. W., Knezevich, E. L., Pena, L. E. D., Gross, B., Knezevich, J. T., Ginzburg, R., Albanese, N. P., et al. (2022) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1733 · Cited by 8
Wysham, C., & Kruger, D. F. (2021) · Journal of the Endocrine Society · doi:10.1210/jendso/bvab064 · Cited by 7
Time in Range: Ein neuer Parameter – komplementär zum HbA 1c
Danne, T., Kordonouri, O., Biester, T., Siegmund, T., Kröger, J., Bramlage, P., & Haak, T. (2019) · Deutsches Ärzteblatt · doi:10.3238/persdia.2019.10.25.01 · Cited by 6
A Review on Newer Interventions for the Prevention of Diabetic Foot Disease
Tekale, S., Varma, A. R., Tekale, S., & Kumbhare, U. (2022) · Cureus · doi:10.7759/cureus.30591 · Cited by 7
Technology for Augmenting Type 1 Diabetes Mellitus Management
Condren, M. E., Sabet, S., Chalmers, L. J., Saley, T. P., & Hopwood, J. (2019) · The Journal of Pediatric Pharmacology and Therapeutics · doi:10.5863/1551-6776-24.2.99 · Cited by 6
Nosova, E. V., O’Malley, G., Dassau, E., & Levy, C. J. (2020) · Journal of Diabetes · doi:10.1111/1753-0407.13030 · Cited by 6
Home insulin pump use in hospitalized children with type 1 diabetes
Owens, J., Courter, J., Schuler, C. L., Lawrence, M., Hornung, L., & Lawson, S. (2024) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.54595 · Cited by 5
The pharmacist’s role in continuous glucose monitoring
Isaacs, D. M. (2020) · Pharmacy Today · doi:10.1016/j.ptdy.2020.04.014 · Cited by 5
Hanaire, H. P., Atlan, C., Benhamou, P., Bismuth, É., Bonnemaison, É., Borot, S., Catargi, B., Charpentier, G., Farret, A., Filhol, N., et al. (2017) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(18)30030-0 · Cited by 5
Neue Therapieoptionen mit kontinuierlich gemessenen Glukosedaten – Empfehlungen für die Praxis
Seufert, J., Deiss, D., Gölz, S., Haak, T., Klausmann, G., Kroeger, J., Lobmann, R., Pfeiffer, A. F. H., Schnell, O., Seibold, A., et al. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/a-0978-4537 · Cited by 4
Shah, N. Z., Deshmukh, H., Wilmot, E. G., Patmore, J., Choudhary, P., Christian, P., Herring, R. A., Furlong, N. J., Saunders, S., Narendran, P., et al. (2021) · British Journal of Diabetes · doi:10.15277/bjd.2021.308 · Cited by 4
Marian, C. V. (2022) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb55594.2022.9991724 · Cited by 4
Unnikrishnan, A., Saboo, B., Joshi, S., Kesavadev, J., Makkar, B. M., Agarwal, S., Aravind, S. R., Seshadri, K., Chawla, M. S., Deshpande, N., et al. (2019) · PubMed · Cited by 4
Eleftheriadou, I., Didangelos, T., Pappas, A. C., Anastasiou, E., Vasilopoulos, C., Zoupas, C., Manes, C., Tsatsoulis, A. A., Benroubi, M., Pangalos, E., et al. (2019) · HORMONES · doi:10.1007/s42000-019-00153-1 · Cited by 5
Guideline Development for Medical Device Technology: Issues for Consideration
Battelino, T., Brosius, F. C., Ceriello, A., Cosentino, F., Green, J., Kellerer, M., Koob, S., Kosiborod, M., Lalic, N. M., Marx, N., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221093355 · Cited by 4
Raju, S. M., Goucher, A., Capelson, R., & Kothari, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819867683 · Cited by 3
Ojha, M. D., Yadav, A., & P., H. (2022) · Journal of Biomolecular Structure and Dynamics · doi:10.1080/07391102.2022.2142847 · Cited by 7
Marian, C. V. (2022) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb55594.2022.9991633 · Cited by 3
Inpatient Use of Automated Insulin Delivery Systems
Chadalawada, L., Parab, R., Feeley, J. M., Hughes, M. S., Pasquel, F. J., & Davis, G. M. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251412442 · Cited by 3
Olsen, M. T., Hjejle, S., Rasmussen, L. M., Klarskov, C. K., Lindegaard, B., Andersen, J. A., Gottlieb, H., Lunding, S., Nørgaard, K., Pedersen‐Bjergaard, U., et al. (2025) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaf137 · Cited by 2
Burgos, C., Cortés, J. ‐., Hidalgo, J. I., & Villanueva, R. J. (2022) · International Journal of Computer Mathematics · doi:10.1080/00207160.2022.2142041 · Cited by 2
Clinical Practice Update: Inpatient Insulin Pump and Integrated Insulin Delivery Systems
Nguyen, S., Davis, G. M., & Vasudevan, M. M. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_7 · Cited by 2
Alazmi, A. A., Brema, I. A., ALZAHRANI, S. H., & Almehthel, M. S. (2024) · Cureus · doi:10.7759/cureus.63947 · Cited by 2
Qi, Y., ZHENG, X., Li-Na, B. I., Hu, S., Li, C., Zhang, Y., Wen-Li, S. H. I., Yue, Y.-J., & Li, Q. (2024) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.24.16076-8 · Cited by 2
AGP Reports for Glucose and Insulin Devices Qualitative Study: What Patients and Clinicians Want
Mullen, D. M., Bergenstal, R. M., Johnson, M. L., Cengiz, E., Criego, A. B., Deeb, L. C., Goland, R., Rudolph, J., Arnold, K. C., Kruger, D. F., et al. (2025) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106251337486 · Cited by 2
Continuous glucose monitoring for the prevention of morbidity and mortality in preterm infants
Galderisi, A., Bruschettini, M., Russo, C., Hall, R., & Trevisanuto, D. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013309 · Cited by 5
Managing Diabetes in the Digital Age
Dugan, J. A., Ahmed, S., Vincent, M., Perry, R., & Young, C. F. (2020) · Physician Assistant Clinics · doi:10.1016/j.cpha.2019.12.003 · Cited by 2
New Medications for the Treatment of Diabetes
Garg, S. K., GIORDANO, D. A., Gallo, T., & Shah, V. N. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.2512 · Cited by 2
Pathophysiology and Management of Type 1 Diabetes
Georga, E. I., Fotiadis, D. I., & Tigas, S. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804831-3.00002-9 · Cited by 2
Pappada, S. M., Woodling, K., Owais, M. H., Zink, E. M., Dahbour, L., Tripathi, R. S., Khuder, S., & Papadimos, T. J. (2018) · BMC Research Notes · doi:10.1186/s13104-018-3656-3 · Cited by 1
McFadden, N. T., Wilkerson, A. H., Chaney, B. H., Carmack, H. J., Jaiswal, J., Stellefson, M., & Lovett, K. (2024) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106241268412 · Cited by 3
Interpretation of the Chinese Clinical Guideline for Continuous Glucose Monitoring
Jia, W. (2018) · Springer eBooks · doi:10.1007/978-981-10-7074-7_10 · Cited by 1
Clinical Indications for Continuous Glucose Monitoring
Jia, W. (2018) · Springer eBooks · doi:10.1007/978-981-10-7074-7_9 · Cited by 1
Sforza, V., & Cimini, R. (2020) · International Journal of Business and Social Science · doi:10.30845/ijbss.v11n3a5 · Cited by 1
Assessing the Knowledge and Awareness of Self-Management among Diabetic Patients in Saudi Arabia
Bakhuraysah, M. M., Alsalmi, S. A., Alfadli, S. N., Alotaibi, S. A., Althomali, D. S., Gharib, A. F., Alrehaili, A. A., & Alhuthali, H. M. (2022) · Research Review · doi:10.52845/jmrhs/2022-5-7-5 · Cited by 2
Status of Continuous Glucose Monitoring Technology in Clinical Practice
O’Connor, C., & Aleppo, G. (2019) · doi:10.2337/9781580406932.part1_ch04 · Cited by 1
Paglialunga, S., Morimoto, B. H., de la Peña, A., & Fortier, C. (2018) · Clinical Pharmacology in Drug Development · doi:10.1002/cpdd.437 · Cited by 2
Burgos, C., Cervigón, C., Hidalgo, J. I., & Villanueva, R. J. (2019) · Computational and Mathematical Methods · doi:10.1002/cmm4.1064 · Cited by 1
Williams, M. E. (2019) · Kidney International · doi:10.1016/j.kint.2019.05.003 · Cited by 1
Seven facts you need to know about continuous glucose monitors
Solano, L. (2022) · JAAPA · doi:10.1097/01.jaa.0000854536.09072.5e · Cited by 1
Garg, S. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.2499 · Cited by 1
Advances on Uncertainty Quantification Techniques for Dynamical Systems: Theory and Modelling
Burgos, C. (2021) · doi:10.4995/thesis/10251/166442 · Cited by 1
Portable Electrochemical Sensing Systems
An, Z., Wu, Y., Zhao, Y., Lu, Y., & Liu, Q. (2024) · doi:10.1002/9783527841080.ch2 · Cited by 1
Sensor mightier than pump—the jury is still out
Hovorka, R. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30235-8
The Advancing Technologic Role in the Treatment of Diabetes
Roberts, V. L., & List, K. (2017) · Journal of Diabetes Research and Therapy · doi:10.16966/2380-5544.130
Technology Advancement: Hybrid Closed-Loop Insulin Pump
Lausch, M. J. (2018) · AADE in Practice · doi:10.1177/2325160318789152
Part I: Continuous glucose monitoring systems
Moorman, J. M. (2020) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1260
Study On Effect Of Exercise On Fasting Blood Glucose Levels
Rekha, G. S. (2020) · International Journal of Anatomy & Applied Physiology · doi:10.19070/2572-7451-2000024
Reducing the rates of diabetes across the United States
Coleman, M. D., & Davies, A. (2020) · Journal of the American Pharmacists Association · doi:10.1016/j.japh.2020.09.018
Oliveira, L. S. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.17.2019.tde-30062021-155342
Continuous glucose monitoring for the prevention of morbidity and mortality in preterm infants
Galderisi, A., Bruschettini, M., Russo, C., Hall, R., & Trevisanuto, D. (2021) · Yearbook of pediatric endocrinology · doi:10.1530/ey.18.2.1
Type 1 diabetes: technology and transplants
FRCP, D. L. M. (2017) · Wiley eBooks · doi:10.1002/9781119052210.ch8
Manov, A., House, J., Antonio, S., Banal, M., & Nazha, J. (2023) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2023.17.3.0414
What Do You Need to Know About Continuous Glucose Monitoring?
Cedeno, A., & Carmichael, K. A. (2021) · Consultant · doi:10.25270/con.2021.01.00006
Perfilando la tecnología en diabetes
Gómez, N. B., Jiménez-Salazar, S., Delgado, M. R., Botero, J. F., & Rincón, A. R. (2024) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.11.1.852
Ватутин, Н. Т., Sklyannaya, E. V., & Грибов, В. В. (2024) · Oncohematology · doi:10.17650/1818-8346-2024-19-2-118-131
Pumps and Continuous Glucose Monitoring in Children with Diabetes
Wong, J. C., Capodanno, G., & Adi, S. (2019) · doi:10.2337/9781580406932.part1_ch09
Infrastructure of Diabetes Clinics and Centers to Support Diabetes Technology
Draznin, B., & McDermott, M. (2019) · Diabetes Technology · doi:10.2337/9781580406932.part1_ch02
Seley, J. J., & Gregory, N. S. (2019) · doi:10.2337/9781580406932.part2_ch03
Sobczak, C., Oser, S. M., Warman, M., Daffron, A., Buss, D., Wettergreen, S. A., Oser, T. K., Parascando, J. A., & Jortberg, B. T. (2025) · ADCES in Practice · doi:10.1177/2633559x251328956
Chaudhary, R., Dwivedi, S., & Jha, S. (2025) · International Conference on Inventive Systems and Control (ICISC) · doi:10.1109/icisc65841.2025.11188212
Who is using continuous glucose monitoring for type 2 diabetes management? A scoping review protocol
Kragen, B., Resnik, J., Vimalananda, V. G., Sitter, K. E., Leibowitz, A. J., UNDERWOOD, P. C., & Kim, B. H. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-106809
Avari, P., Robinson, C., Leelarathna, L., & Thabit, H. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251381282
Olsen, M. T., Klarskov, C. K., Pedersen-Bjergaard, U., Hansen, K. B., & Kristensen, P. L. (2024) · Figshare · doi:10.6084/m9.figshare.26716423
Olsen, M. T., Klarskov, C. K., Pedersen-Bjergaard, U., Hansen, K. B., & Kristensen, P. L. (2024) · Figshare · doi:10.6084/m9.figshare.26716426
Bello, M. A. Y., Pesantez, M. J., Saalinger, M. N., Sanz, A. M., Shikh, S., Mesa, B., Chirinos, A. A., Macias, A. J., Nisenboym, T., Bernal‐Mizrachi, E., et al. (2026) · Diabetes Obesity and Cardiometabolic CARE · doi:10.2337/doc25-0072
Park-Chong, H., Benrimon, M., & Smaldone, A. M. (2026) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106261451194
Si, Q., Mao, Y., Lan, J., Lu, W., Zheng, C., Zhu, Q., & Zhang, X. L. (2026) · Journal of International Medical Research · doi:10.1177/03000605261477581
Olsen, M. T., Spanakis, E. K., Thabit, H., Dhatariya, K., Mustafa, O. G., Avari, P., Lumb, A. N., Dungan, K. M., Philis‐Tsimikas, A., Kulasa, K. M., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06838-8
Asghar, S., Shaikh, K., Nisar, A., Aftab, S., Qadeer, R., & Wahab, A. (2026) · Cureus · doi:10.7759/cureus.117117
Metadata
- Authors
- Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., & Tamborlane, W.
- Affiliations
- Tulane University (US)
- Oakland University (US)
- T1D Exchange (US)
- University of California San Diego (US)
- Texas Diabetes & Endocrinology (US)
- University of Colorado Anschutz (US)
- University of Washington (US)
- University of Central Florida (US)
- Yale University (US)
- ORCID
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 22
- Issue
- 8
- Pages
- 1008-1021
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W2406099149
- Cited by
- 195
- References
- 68
- Citations by year
- 2026: 6 · 2025: 12 · 2024: 12 · 2023: 9 · 2022: 14 · 2021: 19 · 2020: 23 · 2019: 33 · 2018: 27 · 2017: 38 · 2016: 2
- FWCI
- 33.47
- Type
- journal article
- Language
- en
- Open access
- Locations
- Endocrine Practice (publishedVersion)
- PubMed (publishedVersion)
- Journal of International Crisis and Risk Communication Research (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, diabetes management, type 1 diabetes, type 2 diabetes, intensive insulin therapy, glycemic control, hypoglycemia, healthcare resource utilization, cost-effectiveness, insurance coverage, sensor-augmented pump therapy, self-monitoring of blood glucose, health-related quality of life
- MeSH terms
- Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Endocrinology, Humans, Quality of Life, Blood Glucose Self-Monitoring, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review