Continuous Glucose Monitoring: A Consensus Conference of the American Association of Clinical Endocrinologists and American College of Endocrinology
Open accessAbstract
Objective/methods Barriers to continuous glucose monitoring (CGM) use continue to hamper adoption of this valuable technology for the management of diabetes. The American Association of Clinical Endocrinologists and the American College of Endocrinology convened a public consensus conference February 20, 2016, to review available CGM data and propose strategies for expanding CGM access.Results Conference participants agreed that evidence supports the benefits of CGM in type 1 diabetes and that these benefits are likely to apply whenever intensive insulin therapy is used, regardless of diabetes type. CGM is likely to reduce healthcare resource utilization for acute and chronic complications, although real-world analyses are needed to confirm potential cost savings and quality of life improvements. Ongoing technological advances have improved CGM accuracy and usability, but more innovations in human factors, data delivery, reporting, and interpretation are needed to foster expanded use. The development of a standardized data report using similar metrics across all devices would facilitate clinician and patient understanding and utilization of CGM. Expanded CGM coverage by government and private payers is an urgent need.Conclusion CGM improves glycemic control, reduces hypoglycemia, and may reduce overall costs of diabetes management. Expanding CGM coverage and utilization is likely to improve the health outcomes of people with diabetes.Abbreviations A1C = glycated hemoglobin AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology ASPIRE = Automation to Simulate Pancreatic Insulin Response CGM = continuous glucose monitoring HRQOL = health-related quality of life ICER = incremental cost-effectiveness ratio JDRF = Juvenile Diabetes Research Foundation MARD = mean absolute relative difference MDI = multiple daily injections QALY = quality-adjusted life years RCT = randomized, controlled trial SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR = Sensor-Augmented Pump Therapy for A1C Reduction T1D = type 1 diabetes T2D = type 2 diabetes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In many countries, the benefits and utility of CGM are now recognized by national and international medical organizations for individuals with insulin-requiring diabetes and/or those at risk for hypoglycemia (16-21).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [17]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Hyperglycemic crises in adult patients with diabetes
Kitabchi, A. E., Umpierrez, G. E., Miles, J. M., & Fisher, J. N. (2009) · Diabetes Care · doi:10.2337/dc09-9032 · Cited by 2,062
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · cited 1×
“The number of users in the T1D Exchange clinic registry has more than doubled to 15% in 2016 (1,25,26), and observational data collected in 2014-2015 from the T1D Exchange clinic registry support the benefits of newer devices.”
BackgroundEffectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Self-citationBraithwaite, R. S., Meltzer, D. O., King, J. T., Leslie, D., & Roberts, M. S. (2008) · Medical Care · doi:10.1097/mlr.0b013e31815c31a7 · Cited by 579
Diabetic emergencies - ketoacidosis, hyperglycaemic hyperosmolar state and hypoglycaemia
Umpierrez, G., & Korytkowski, M. (2016) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2016.15 · Cited by 563 · cited 1×
“is $218 billion per year (43); hospitalizations for hypoglycemic and hyperglycemic crises may account for up to $5 billion, based on an estimated cost of approximately $17,500 per hospitalization (44-47).”
BackgroundYeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Research works printed but not linked: 1
- Miller, 2016, Continuous glucose monitoring in T1D patients using injections of insulin: a report from the T1D Exchange clinic registry, Diabetes Technol Ther, 18, A
Cited by
Sorted by citations
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Self-citationAleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Šoupal, J., Petruželková, L., Grunberger, G., Hásková, A., Flekač, M., Matoulek, M., Mikeš, O., Pelcl, T., Škrha, J., Horová, E., et al. (2020) · Diabetes Care · doi:10.2337/dc19-0888 · Cited by 242
Self-citationClinical Implications of Real-time and Intermittently Scanned Continuous Glucose Monitoring
Edelman, S. V., Argento, N. B., Pettus, J., & Hirsch, I. B. (2018) · Diabetes Care · doi:10.2337/dc18-1150 · Cited by 209
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
Carlson, A. L., Mullen, D. M., & Bergenstal, R. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0024 · Cited by 181
Technology in the management of type 1 diabetes mellitus — current status and future prospects
Tauschmann, M., & Hovorka, R. (2018) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0044-y · Cited by 165
Glucose Variability: A Review of Clinical Applications and Research Developments
Rodbard, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0092 · Cited by 154
Glycemic variability: how to measure and its clinical implication for type 2 diabetes
Umpierrez, G. E., & P. Kovatchev, B. (2018) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2018.09.010 · Cited by 148
Aleppo, G., Laffel, L. M., Ahmann, A., Hirsch, I. B., Kruger, D. F., Peters, A. L., Weinstock, R. S., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00388 · Cited by 129
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124
Role of continuous glucose monitoring for type 2 in diabetes management and research
Vigersky, R. A., & Shrivastav, M. (2016) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2016.10.007 · Cited by 117
Zou, Y., Chu, Z., Guo, J., Liu, S., Ma, X., & Guo, J. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115103 · Cited by 120
Johnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 106
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
Mechanick, J. I., Garber, A. J., Grunberger, G., Handelsman, Y., & Garvey, W. T. (2018) · Endocrine Practice · doi:10.4158/ps-2018-0139 · Cited by 109
How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?
Ajjan, R. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0021 · Cited by 104
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Kudva, Y. C., Ahmann, A., Bergenstal, R. M., Gavin, J. R., Kruger, D. F., Midyett, L. K., Miller, E. M., & Harris, D. R. (2018) · Journal of the Endocrine Society · doi:10.1210/js.2018-00294 · Cited by 99
Continuous glucose monitoring in neonates: a review
McKinlay, C. J. D., Chase, J. G., Dickson, J. L., Harris, D. L., Alsweiler, J. M., & Harding, J. E. (2017) · Maternal Health Neonatology and Perinatology · doi:10.1186/s40748-017-0055-z · Cited by 87
Ajjan, R. A., Jackson, N., & Thomson, S. A. (2019) · Diabetes and Vascular Disease Research · doi:10.1177/1479164119827456 · Cited by 79
Lin, Y. K., Fisher, S. J., & Pop‐Busui, R. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13290 · Cited by 82
Shrivastav, M., Gibson, W., Shrivastav, R., Elzea, K., Khambatta, C., Sonawane, R., Sierra, J. A., & Vigersky, R. A. (2018) · Diabetes Spectrum · doi:10.2337/ds17-0024 · Cited by 87
The impact of electronic health record–integrated patient-generated health data on clinician burnout
Ye, J. (2021) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocab017 · Cited by 80
Wood, A. J., O'Neal, D. N., Furler, J., & Ekinci, E. I. (2018) · Internal Medicine Journal · doi:10.1111/imj.13770 · Cited by 66
Aleppo, G., & Webb, K. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818813581 · Cited by 67
Selecting the Appropriate Continuous Glucose Monitoring System – a Practical Approach
Adolfsson, P., Parkin, C. G., Thomas, A., & Krinelke, L. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.1.24 · Cited by 65
Associations between HbA1c and continuous glucose monitoring‐derived glycaemic variables
Hirsch, I. B., Welsh, J. B., Calhoun, P. M., Puhr, S., Walker, T. C., & Price, D. A. (2019) · Diabetic Medicine · doi:10.1111/dme.14065 · Cited by 63
Diabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Continuous Glucose Monitoring and Global Reimbursement: An Update
Graham, C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0096 · Cited by 64
Golledge, J., Fernando, M. E., Lazzarini, P. A., Najafi, B., & Armstrong, D. G. (2020) · Sensors · doi:10.3390/s20164527 · Cited by 65
Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting
Schnell, O., Barnard, K. D., Bergenstal, R. M., Bosi, E., Garg, S. K., Guerci, B., Haak, T., Hirsch, I. B., Ji, L., Joshi, S., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0054 · Cited by 60
Reference Guide for Integrating Continuous Glucose Monitoring Into Clinical Practice
Kruger, D. F., Edelman, S. V., Hinnen, D. A., & Parkin, C. G. (2019) · The Diabetes Educator · doi:10.1177/0145721718818066 · Cited by 55
Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital
Bellido, V., Freckman, G., Pérez, A., & Galindo, R. J. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.06.007 · Cited by 52
Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies
McGill, J. B., & Ahmann, A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0090 · Cited by 49
Grunberger, G., Handelsman, Y., Bloomgarden, Z. T., Fonseca, V. A., Garber, A. J., Haas, R. A., Roberts, V. L., & Umpierrez, G. E. (2018) · Endocrine Practice · doi:10.4158/ps-2017-0155 · Cited by 49
Zheng, X. S., Qi, Y., Bi, L., Shi, W., Zhang, Y., Zhao, D., Hu, S., Li, M., & Li, Q. (2020) · BioMed Research International · doi:10.1155/2020/6408724 · Cited by 47
Diabetes Technology Use in Adults with Type 1 and Type 2 Diabetes
Kravarusic, J., & Aleppo, G. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.006 · Cited by 46
Valente, T., & Arbex, A. K. (2020) · Current Diabetes Reviews · doi:10.2174/1573399816666200716201550 · Cited by 44
Olsen, M. T., Klarskov, C. K., Jensen, S. H., Rasmussen, L. M., Lindegaard, B., Andersen, J. A., Gottlieb, H., Lunding, S., Pedersen‐Bjergaard, U., Hansen, K. B., et al. (2025) · Diabetes Care · doi:10.2337/dc24-2222 · Cited by 44
Kesavadev, J., Vigersky, R. A., Shin, J., Pillai, P. B. S., Shankar, A., Sanal, G., Krishnan, G., & Jothydev, S. (2017) · Advances in Therapy · doi:10.1007/s12325-017-0576-x · Cited by 42
Targeting glucose control in preterm infants: pilot studies of continuous glucose monitoring
Thomson, L. M., Elleri, D., Bond, S. J., Howlett, J., Dunger, D. B., & Beardsall, K. (2018) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2018-314814 · Cited by 42
Chesser, H., Srinivasan, S., Puckett, C., Gitelman, S. E., & Wong, J. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221139873 · Cited by 40
Bergenstal, R. M., HACHMANN-NIELSEN, E., Kvist, K., Peters, A. L., Tarp, J. M., & Buse, J. B. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0447 · Cited by 40
Glucose measurement in body fluids: A ready reckoner for clinicians
Kubihal, S., Goyal, A., Gupta, Y., & Khadgawat, R. (2020) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2020.11.021 · Cited by 40
Sierra, J. A., Shah, M., Gill, M. S., Flores, Z., Chawla, H., Kaufman, F. R., & Vigersky, R. (2018) · Journal of Medical Economics · doi:10.1080/13696998.2017.1390474 · Cited by 38
Garg, S. K., & Aktürk, H. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0142 · Cited by 37
Pilot Study of a Novel Application for Data Visualization in Type 1 Diabetes
Wong, J. C., Neinstein, A. B., Look, H., Arbiter, B., Chokr, N., Ross, C., & Adi, S. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817691305 · Cited by 32
The Future of Continuous Glucose Monitoring
Garg, S. K., & Aktürk, H. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0097 · Cited by 34
Mariani, H., Layden, B. T., & Aleppo, G. (2017) · Clinical Diabetes · doi:10.2337/cd16-0008 · Cited by 33
Volčanšek, Š., Lunder, M., & Janež, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0131 · Cited by 32
The assessment and management of quality of life of older adults with diabetes mellitus
Kassem, L. S., & Aron, D. C. (2020) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2020.1737520 · Cited by 35
Flash Glucose Monitoring: The Future Is Here
Garg, S. K., & Aktürk, H. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0098 · Cited by 32
Bloomgarden, Z. T. (2017) · Journal of Diabetes · doi:10.1111/1753-0407.12590 · Cited by 31
Personal Versus Professional Continuous Glucose Monitoring: When to Use Which on Whom
Longo, R. R., & Sperling, S. B. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0093 · Cited by 30
Krzymień, J., & Ładyżyński, P. (2019) · Nutrients · doi:10.3390/nu11030607 · Cited by 31
Clinical Approach to Flash Glucose Monitoring: An Expert Recommendation
Chico, A., Aguilera, E., Ampudia-Blasco, F., Bellido, V., Cardona-Hernández, R., Escalada, F. J., Fernández, D., Gómez-Peralta, F., de Villar, N. G. P., Gorgojo, J., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819841911 · Cited by 27
Factors influencing the download of mobile health apps: Content review-led regression analysis
Krishnan, G., & Selvam, G. (2019) · Health Policy and Technology · doi:10.1016/j.hlpt.2019.09.001 · Cited by 30
Ulrich, H., & Bowen, M. M. (2021) · Journal of the American Pharmacists Association · doi:10.1016/j.japh.2021.05.013 · Cited by 28
Klueh, U., Czajkowski, C., Ludzinska, I., Qiao, Y., Frailey, J. T., & Kreutzer, D. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.026 · Cited by 27
Conway, B. N., Snell‐Bergeon, J. K., Honda-Kohmo, K., Peddi, A. K., Isa, S. B., Sulong, S., Sibomana, L., Gonzalez, A. G., Song, J., Lomax, K., et al. (2024) · Journal of the Endocrine Society · doi:10.1210/jendso/bvae210 · Cited by 29
Asymptomatic hypoglycaemia in Type 1 diabetes: incidence and risk factors
Henriksen, M. M., Andersen, H. U., Thorsteinsson, B., & Pedersen‐Bjergaard, U. (2018) · Diabetic Medicine · doi:10.1111/dme.13848 · Cited by 26
Conway, R. B. N., Gonzalez, A. G., Shah, V. N., Rasmussen, C. G., Aktürk, H. K., Pyle, L. L., Forlenza, G. P., Alonso, G. T., & Snell‐Bergeon, J. K. (2023) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s416192 · Cited by 26
Dril, E. V., & Schumacher, C. (2019) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1088 · Cited by 25
Gill, M., Zhu, C., Shah, M., & Chhabra, H. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818777265 · Cited by 23
Chinese clinical guidelines for continuous glucose monitoring (2018 edition)
Bao, Y., Chen, L., Chen, L., Dou, J., Gao, Z., Gao, L., Guo, L., Guo, X., Ji, L., Ji, Q., et al. (2019) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3152 · Cited by 23
Kamusheva, M., Tachkov, K., Dimitrova, M. J., Mitkova, Z. E., García-Sáez, G., Hernando, M. E., Goettsch, W., & Petrova, G. I. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.636959 · Cited by 23
Hirsch, I. B., & Verderese, C. A. (2017) · Endocrine Practice · doi:10.4158/ep171962.ra · Cited by 22
Use of Continuous Glucose Monitoring in Youth-Onset Type 2 Diabetes
Chan, C. L. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0905-0 · Cited by 22
Moser, O., Pandis, M., Aberer, F., Kojzar, H., Hochfellner, D. A., Elsayed, H., Motschnig, M., Augustin, T., Kreuzer, P., Pieber, T. R., et al. (2018) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13598 · Cited by 22
Professional flash continuous glucose monitoring as a supplement to A1C in primary care
Hirsch, I. B. (2017) · Postgraduate Medicine · doi:10.1080/00325481.2017.1383137 · Cited by 24
JENDLE, J. H., Smith‐Palmer, J., Delbaere, A., de Portu, S., Papo, N. L., Valentine, W. J., & Roze, S. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0294-z · Cited by 21
The Ambulatory Glucose Profile: Opportunities for Enhancement
Rodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0524 · Cited by 20
Integrating Continuous Glucose Monitoring Into Clinical Practices and Patients' Lives
Hirsch, I. B., & Miller, E. M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0233 · Cited by 20
Interpretation of hemoglobin A1C in primary care setting
Fayyaz, B., Rehman, H. J., & Minn, H. (2019) · Journal of Community Hospital Internal Medicine Perspectives · doi:10.1080/20009666.2018.1559432 · Cited by 24
Olsen, M. T., Klarskov, C. K., Pedersen‐Bjergaard, U., Hansen, K. B., & Kristensen, P. L. (2024) · BMC Endocrine Disorders · doi:10.1186/s12902-024-01595-4 · Cited by 19
Evolving Use of Continuous Glucose Monitoring Beyond Intensive Insulin Treatment
Wright, E. E., & Subramanian, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0191 · Cited by 19
Olsen, M. T., Liarakos, A. L., Wilmot, E. G., Dhatariya, K., Thabit, H., Sánchez-García, D., Nørgaard, K., Pedersen‐Bjergaard, U., Hansen, K. B., Vangoitsenhoven, R., et al. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf074 · Cited by 17
Defining relevant hypoglycemia measures in children and adolescents with type 1 diabetes
Jones, T. W., & On behalf of the ISPAD Hypoglycemia Guidelines Writing Group (2017) · Pediatric Diabetes · doi:10.1111/pedi.12600 · Cited by 18
Ekhlaspour, L., Tabatabai, I., & Buckingham, B. A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819851790 · Cited by 16
Henriksen, M. M., Andersen, H. U., Thorsteinsson, B., & Pedersen‐Bjergaard, U. (2021) · Diabetologia · doi:10.1007/s00125-020-05360-9 · Cited by 17
Vimalananda, V. G., Kragen, B., Leibowitz, A. J., Qian, S. X., Wormwood, J. B., Linsky, A. M., UNDERWOOD, P. C., Conlin, P. R., & Kim, B. H. (2025) · BMC Family Practice · doi:10.1186/s12875-025-02764-7 · Cited by 18
Why Download Data: The Benefits and Challenges of More Diabetes Data
Arbiter, B., Look, H., McComb, L., & Snider, C. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0099 · Cited by 16
Mangrola, D., Cox, C., Furman, A. S., Krishnan, S., & Karakas, S. E. (2017) · Endocrine Practice · doi:10.4158/ep-2017-0032 · Cited by 17
Using Flash Continuous Glucose Monitoring in Primary Practice
Hirsch, I. B., & Wright, E. E. (2018) · Clinical Diabetes · doi:10.2337/cd18-0054 · Cited by 15
Madrid, L., Sitoe, A., Varo, R., Nhampossa, T., Lanaspa, M., Nhama, A., Acácio, S., Galán, I. R., Casellas, A., & Bassat, Q. (2017) · Malaria Journal · doi:10.1186/s12936-017-1840-x · Cited by 15
Cuesta–Frau, D., Novák, D., Burda, V., Molina, Á., Vargas, B., Mráz, M., Kaválková, P., Beneš, M., & Haluzı́k, M. (2018) · Entropy · doi:10.3390/e20110871 · Cited by 14
Battelino, T., Edelman, S. V., Nishimura, R., & Bergenstal, R. M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0180 · Cited by 13
Making sense of glucose sensors in end-stage kidney disease: A review
Williams, M. E., Steenkamp, D., & Wolpert, H. A. (2022) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2022.1025328 · Cited by 13
Camerlingo, N., Vettoretti, M., Facchinetti, A., Sparacino, G., Mader, J. K., Choudhary, P., & Favero, S. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-75079-5 · Cited by 13
Standardized Hybrid Closed-Loop System Reporting
Shah, V. N., & Garg, S. K. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0622 · Cited by 14
Continuous glucose monitoring for the prevention of morbidity and mortality in preterm infants
Galderisi, A., Bruschettini, M., Russo, C., Hall, R., & Trevisanuto, D. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013309.pub2 · Cited by 12
Hirsch, I. B., Nardacci, E., & Verderese, C. A. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0059 · Cited by 12
Barnard-Kelly, K. D. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0015 · Cited by 11
Metadata
- Authors
- Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., & Tamborlane, W.
- Affiliations
- Tulane University (US)
- Oakland University (US)
- T1D Exchange (US)
- University of California San Diego (US)
- Texas Diabetes & Endocrinology (US)
- University of Colorado Anschutz (US)
- University of Washington (US)
- University of Central Florida (US)
- Yale University (US)
- ORCID
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 22
- Issue
- 8
- Pages
- 1008-1021
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W2406099149
- Cited by
- 195
- References
- 68
- Citations by year
- 2026: 6 · 2025: 12 · 2024: 12 · 2023: 9 · 2022: 14 · 2021: 19 · 2020: 23 · 2019: 33 · 2018: 27 · 2017: 38 · 2016: 2
- FWCI
- 33.47
- Type
- journal article
- Language
- en
- Open access
- Locations
- Endocrine Practice (publishedVersion)
- PubMed (publishedVersion)
- Journal of International Crisis and Risk Communication Research (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, diabetes management, type 1 diabetes, type 2 diabetes, intensive insulin therapy, glycemic control, hypoglycemia, healthcare resource utilization, cost-effectiveness, insurance coverage, sensor-augmented pump therapy, self-monitoring of blood glucose, health-related quality of life
- MeSH terms
- Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Endocrinology, Humans, Quality of Life, Blood Glucose Self-Monitoring, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review