CoChat

Measuring Gait Speed in the Out-Patient Clinic: Methodology and Feasibility

Open access
Karpman, Craig, LeBrasseur, Nathan K, DePew, Zachary S, Novotny, Paul J, Benzo, Roberto P · 2014 · Respiratory Care
Cited by 101

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Gait speed is a simple physical function measure associated with key outcomes in the elderly population. Gait speed measurements may improve clinical care in patients with COPD. However, there is a knowledge gap about the reliability and variability of gait speed testing protocols in COPD. We evaluated established techniques of measuring gait speed in patients with COPD and assessed feasibility of implementing gait speed as a routine vital sign in an out-patient clinic. METHODS: The usual 4-meter gait speed (4MGS) ("walk at a comfortable/natural pace"), maximal 4MGS ("walk as fast as you can safely"), usual 10-meter gait speed (10MGS), and maximal 10MGS of subjects with stable COPD were measured. Walks were measured using a stopwatch and automated timing system. For the feasibility/implementation phase, patients from the entire spectrum of respiratory diseases completed acceptability surveys, and clinical assistants administered gait speed measurements using an automated timing system. Time to train and to administer the test and acceptability by the staff were evaluated. RESULTS: Seventy subjects enrolled; 60% were men, and the mean age ± SD was 69 ± 10 years. All methods showed excellent test-retest reliability (intraclass correlation coefficient of 0.95-0.97). The difference between the two timing systems did not exceed the suggested minimal clinically important difference of 0.1 m/s for the usual pace instructions but did exceed 0.1 m/s for maximal pace walks. The difference between 4MGS and 10MGS was 0.13 ± 0.10 m/s. FEASIBILITY: Most subjects reported that gait speed measurement prior to clinic appointment was very acceptable (66%) or acceptable (33%). Time added to clinic visit measuring 4MGS was 95 ± 20 seconds, and clinical assistants reported gait speed measurements as very acceptable (60%), acceptable (30%), and somewhat acceptable (10%). CONCLUSIONS: Gait speed is a reliable measure in COPD, regardless of instructed pace, distance, or timing mechanism; however, adhering to one protocol is suggested. 4MGS was easily implemented into clinical practice with high acceptability by patients and clinic staff.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.02688

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Karpman, C., LeBrasseur, N. K., DePew, Z. S., Novotny, P. J., & Benzo, R. P.
Venue
Respiratory Care
Published
2014-04-01
Volume
59
Issue
4
Pages
531-537
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2125596313
Cited by
101
References
8
FWCI
2.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.