The DOI matches its OpenAlex record; 26 of the 26 references it cites were found in a registry or an index.
Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Abstract
OBJECTIVE: To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS: Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tidal volume, minute volume, blood oxygen saturation, and transcutaneously measured P(CO2). We also measured user comfort and exertion, FFR moisture retention, and the carbon dioxide and oxygen concentrations in the FFR's dead space. RESULTS: There were no significant differences between FFR and control in the physiological variables, exertion scores, or comfort scores. There was no significant difference in moisture retention between FFR with and without exhalation valve. Two subjects had peak P(CO2) > or = 50 mm Hg. The FFR with exhalation valve offered no benefit in physiological burden over the FFR without valve. The FFR dead-space oxygen and carbon dioxide levels did not meet the Occupational Safety and Health Administration's ambient workplace standards. CONCLUSIONS: In healthy healthcare workers, FFR did not impose any important physiological burden during 1 hour of use, at realistic clinical work rates, but the FFR dead-space carbon dioxide and oxygen levels were significantly above and below, respectively, the ambient workplace standards, and elevated P(CO2) is a possibility. Exhalation valve did not significantly ameliorate the FFR's P(CO2) impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Borg's Perceived Exertion and Pain Scales
Borg, G. A. V. (1998) · Cited by 3,366
Li, Y., Tokura, H., Guo, Y. P., Wong, A. S. W., Wong, T., Chung, J., & Newton, E. (2005) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-004-0584-4 · Cited by 364
Anderson, C. A., Anderson, K. B., & Deuser, W. E. (1996) · Personality and Social Psychology Bulletin · doi:10.1177/0146167296224004 · Cited by 254
Respirator Tolerance in Health Care Workers
Radonovich, L. J. (2009) · JAMA · doi:10.1001/jama.2008.894 · Cited by 217
In vivo protective performance of N95 respirator and surgical facemask
Li, Y., Wong, T., Chung, J., Guo, Y. P., Hu, J. Y., Guan, Y. T., Yao, L., Song, Q. W., & Newton, E. (2006) · American Journal of Industrial Medicine · doi:10.1002/ajim.20395 · Cited by 159
Eberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 143
Monitoring of Ventilation During Exercise by a Portable Respiratory Inductive Plethysmograph
Clarenbach, C. F., Senn, O., Brack, T., Kohler, M., & Bloch, K. E. (2005) · Chest · doi:10.1378/chest.128.3.1282 · Cited by 140
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Saatci, E., Miller, D. M., Stell, I. M., et al. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00039503 · Cited by 126
Kaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 121
Cited by
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Rebmann, T., Carrico, R., & Wang, J. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2013.02.017 · Cited by 269
Commentary: Physiological and Psychological Impact of Face Mask Usage during the COVID-19 Pandemic
Scheid, J. L., Lupien, S. P., Ford, G. S., & West, S. L. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186655 · Cited by 259
Health Effects of Wildfire Smoke in Children and Public Health Tools: A Narrative Review
Holm, S. M., Miller, M. D., & Balmes, J. R. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-00267-4 · Cited by 246
Masks and Face Coverings for the Lay Public: A Narrative Update
Czypionka, T., Greenhalgh, T., Bassler, D., & Bryant, M. B. (2021) · Annals of Internal Medicine · doi:10.7326/m20-6625 · Cited by 82
Metadata
- Authors
- Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2010-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2164438961
- Cited by
- 276
- References
- 26
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers. https://app.cochat.ai/papers/10.4187/respcare.10550569
- The paper
- Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010). Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers. Respiratory Care. https://doi.org/10.4187/respcare.10550569
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.