An experimental study on passive charge balancing
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a simplified analysis of the electrode potential upon mismatched, biphasic stimulation using passive discharge techniques, e.g. by shortening of the electrodes. It turns out that especially for microelectrodes the required shorting intervals become as large as to limit a feasible stimulation interval. If no blocking capacitors can be used due to limited space and the degree of miniaturisation, the passive discharge even imposes severe risks to the surrounding tissue and the electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155
Imbalanced biphasic electrical stimulation: Muscle tissue damage
Scheiner, A., Mortimer, J. T., & Roessmann, U. (1990) · Annals of Biomedical Engineering · doi:10.1007/bf02364157 · Cited by 117
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Stanslaski, S., Herron, J., Chouinard, T., Bourget, D., Isaacson, B., Kremen, V., Opri, E., Drew, W., Brinkmann, B. H., Gunduz, A., et al. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2880148 · Cited by 191
“The impact of the recharge changes was studied in a saline tank that models the environment of the tissue-electrode interface [23].”
An active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170
Self-citationRetinal Stimulator ASIC Architecture Based on a Joint Power and Data Optical Link
Lemaire, W., Benhouria, M., Koua, K., Besrour, M., Gauthier, L.-P., Martin-Hardy, G., Rossignol, T., Roy, S., & Fontaine, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3045141 · Cited by 32
Does a coupling capacitor enhance the charge balance during neural stimulation? An empirical study
van Dongen, M. N., & Serdijn, W. A. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1312-9 · Cited by 23
“All in all, it can be concluded that in contrast to what many other studies have suggested [4, 14, 15], the introduction of Cc does not improve the charge-balancing process and it is furthermore associated with the loss of control over the pseudosteady-state value of VCdl.”
BackgroundResult
Metadata
- Authors
- Sooksood, K., Stieglitz, T., & Ortmanns, M.
- Venue
- Advances in Radio Science
- Publisher
- Copernicus GmbH
- Published
- 2009-05-19
- Volume
- 7
- Pages
- 197-200
- ISSN
- 1684-9965 (ISSN-L)
- 1684-9973
- OpenAlex
- W2123582408
- Cited by
- 27
- References
- 2
- FWCI
- 0.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.