CoChat

Validation of a Consumer Sleep Wearable Device With Actigraphy and Polysomnography in Adolescents Across Sleep Opportunity Manipulations

Open access
Lee, Xuan Kai, Chee, Nicholas I.Y.N., Ong, Ju Lynn, Teo, Teck Boon, van Rijn, Elaine, Lo, June C., Chee, Michael W.L. · 2019 · Journal of Clinical Sleep Medicine
Cited by 141

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

To compare the quality and consistency in sleep measurement of a consumer wearable device and a research-grade actigraph with polysomnography (PSG) in adolescents. Fifty-eight healthy adolescents (aged 15–19 years; 30 males) underwent overnight PSG while wearing both a Fitbit Alta HR and a Philips Respironics Actiwatch 2 (AW2) for 5 nights, with either 5 hours or 6.5 hours time in bed (TIB) and for 4 nights with 9 hours TIB. AW2 data were evaluated using two different wake and immobility thresholds. Discrepancies in estimated total sleep time (TST) and wake after sleep onset (WASO) between devices and PSG, as well as epoch-by-epoch agreements in sleep/wake classification, were assessed. Fitbit-generated sleep staging was compared to PSG. Fitbit and AW2 under default settings similarly underestimated TST and overestimated WASO (TST: medium setting (M10) ≤ 38 minutes, Fitbit ≤ 47 minutes; WASO: M10 ≤ 38 minutes; Fitbit ≤ 42 minutes). AW2 at the high motion threshold setting provided readings closest to PSG (TST: ≤ 12 minutes; WASO: ≤ 18 minutes). Sensitivity for detecting sleep was ≥ 90% for both wearable devices and further improved to 95% by using the high threshold (H5) setting for the AW2 (0.95). Wake detection specificity was highest in Fitbit (≥ 0.88), followed by the AW2 at M10 (≥ 0.80) and H5 thresholds (≤ 0.73). In addition, Fitbit inconsistently estimated stage N1 + N2 sleep depending on TIB, underestimated stage N3 sleep (21–46 min), but was comparable to PSG for rapid eye movement sleep. Fitbit sensitivity values for the detection of N1 + N2, N3 and rapid eye movement sleep were ≥ 0.68, ≥ 0.50, and ≥ 0.72, respectively. A consumer-grade wearable device can measure sleep duration as well as a research actigraph. However, sleep staging would benefit from further refinement before these methods can be reliably used for adolescents. Registry: ClinicalTrials.gov; Title: The Cognitive and Metabolic Effects of Sleep Restriction in Adolescents; Identifier: NCT03333512; URL: https://clinicaltrials.gov/ct2/show/NCT03333512 Lee XK, Chee NIYN, Ong JL, Teo TB, van Rijn E, Lo JC, Chee MWL. Validation of a consumer sleep wearable device with actigraphy and polysomnography in adolescents across sleep opportunity manipulations. J Clin Sleep Med. 2019;15(9):1337–1346.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5664/jcsm.7932

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Lee, X. K., Chee, N. I. Y. N., Ong, J. L., Teo, T. B., van Rijn, E., Lo, J. C., & Chee, M. W. L.
Venue
Journal of Clinical Sleep Medicine
Published
2019-09-15
Volume
15
Issue
9
Pages
1337-1346
ISSN
  • 1550-9389 (ISSN-L)
  • 1550-9397
OpenAlex
W2972951384
Cited by
141
References
9
FWCI
15.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.