CoChat

Longitudinal Associations between Objective Sleep and Lipids: The CARDIA Study

Open access
Petrov, Megan E. Ruiter, Kim, Yongin, Lauderdale, Diane, Lewis, Cora E., Reis, Jared P., Carnethon, Mercedes R., Knutson, Kristen, Glasser, Stephen J. · 2013 · Sleep
Cited by 76

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVE: To investigate the longitudinal relationships between actigraph-derived sleep duration, fragmentation, and lipid levels. DESIGN AND SETTING: Longitudinal data from the Coronary Artery Risk Development in Young Adults Sleep Study (2003-05), an observational cohort at the Chicago site. PARTICIPANTS: There were 503 black and white adults, ages 32-51 years, with no prior history of cardiovascular disease. INTERVENTIONS: N/A. MEASUREMENT AND RESULTS: Sleep duration and fragmentation were measured using 6 days of wrist actigraphy. Sleep quality was measured with the Pittsburgh Sleep Quality Index. The outcome variables, measured at 3 examinations over 10 years (Baseline [2000-01], 5-year [2005-06], and 10-year follow-up [2010-11]), were total cholesterol (TC), high-density lipoprotein (HDL), low-density lipoprotein (LDL), triglycerides (TG), and TC/HDL ratio. The associations between each sleep parameter and 10-year change in lipids were analyzed with generalized estimating equation models adjusting for relevant confounders. After adjustment, each hour increase in sleep duration was significantly associated with higher TC (5.2 mg/dL, 95%CI: 1.7, 8.6) and LDL (3.4 mg/dL, 95%CI: 0.2, 6.6) in the total sample, a 1.1 mg/dL increase in TG (95%CI: 1.0, 1.1) among men, and a borderline significant greater odds for a TC/HDL ratio ≥ 5 among men (OR: 1.37, 95%CI: 0.99, 1.90). Overall, sleep fragmentation and sleep quality scores were not associated with change in lipids. CONCLUSIONS: Beyond relevant covariates, over a 10-year follow-up, longer objective sleep duration was longitudinally and significantly associated with a poorer lipid profile. Greater objective sleep fragmentation and self-reported poor sleep quality were not related to a poorer lipid profile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.3104

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

Metadata

Authors
Petrov, M. E. R., Kim, Y., Lauderdale, D., Lewis, C. E., Reis, J. P., Carnethon, M. R., Knutson, K., & Glasser, S. J.
Venue
Sleep
Published
2013-11-01
Volume
36
Issue
11
Pages
1587-1595
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2050347903
Cited by
76
References
24
FWCI
9.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.