Creatinine Measurement: State of the Art in Accuracy and Interlaboratory Harmonization
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Context. —The National Kidney Disease Education Program recommends calculating glomerular filtration rate from serum creatinine concentration. Accurate creatinine measurements are necessary for this calculation. Objective. —To evaluate the state of the art in measuring serum creatinine, as well as the ability of a proficiency testing program to measure bias for individual laboratories and method peer groups. Design. —A fresh-frozen, off-the-clot pooled serum specimen plus 4 conventional specimens were sent to participants in the College of American Pathologists Chemistry Survey for assay of creatinine. Creatinine concentrations were assigned by isotope dilution mass spectrometry reference measurement procedures. Participants. —Clinical laboratories with an acceptable result for all 5 survey specimens (n = 5624). Results. —The fresh frozen serum (FFS) specimen had a creatinine concentration of 0.902 mg/dL (79.7 μmol/L). Mean bias for 50 instrument-method peer groups varied from −0.06 to 0.31 mg/dL (−5.3 to 27.4 μmol/L), with 30 (60%) of 50 peer groups having significant bias ( P < .001). The bias variability was related to instrument manufacturer ( P ≤ .001) rather than method type ( P = .02) with 24 (63%) of 38 alkaline picric acid methods and with 6 (50%) of 12 enzymatic methods having significant biases. Two conventional specimens had creatinine concentrations of 0.795 and 2.205 mg/dL (70.3 and 194.9 μmol/L) and had apparent survey biases significantly different ( P < .001) from that of the FFS specimen for 34 (68%) and 35 (70%) of 50 peer groups, respectively. Conclusions. —Thirty of 50 peer groups had significant bias for creatinine. Bias was primarily associated with instrument manufacturer, not with type of method used. Proficiency testing using a commutable specimen measured participant bias versus a reference measurement procedure and provided trueness surveillance of instrument-method peer groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coresh, J., Astor, B. C., McQuillan, G., Kusek, J., Greene, T., Van Lente, F., & Levey, A. S. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32765 · Cited by 717
Hoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Self-citationEffects of Drugs on Clinical Laboratory Tests
Young, D. S., Thomas, D. W., Friedman, R. B., & Pestaner, L. C. (1972) · Clinical Chemistry · doi:10.1093/clinchem/18.10.1041 · Cited by 646
Analytical Reviews in Clinical Biochemistry: The Estimation of Creatinine
Spencer, K. (1986) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456328602300101 · Cited by 375
Miller, W. G. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00370-4 · Cited by 104
Ross, J. W., Miller, W. G., Gl, M., & Præstgaard, J. (1998) · PubMed · Cited by 85
Stöckl, D., & Reinauer, H. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.6.993 · Cited by 83
Thienpont, L. M., Nieuwenhove, B. V., Stöckl, D., Reinauer, H., & Ap, D. L. (1996) · PubMed · Cited by 46
Self-citationCobbaert, C., Weykamp, C., Baadenhuijsen, H., Kuypers, A., Lindemans, J., & Jansen, R. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.9.1526 · Cited by 45
Cited by
Levey, A. S., Coresh, J., Greene, T., Stevens, L. A., Zhang, Y. (., Hendriksen, S., Kusek, J. W., & Van Lente, F. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-4-200608150-00004 · Cited by 5,725
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Levey, A. S., Coresh, J., Greene, T., Marsh, J., Stevens, L. A., Kusek, J. W., Van Lente, F., & for Chronic Kidney Disease Epidemiology Collaboration (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.077180 · Cited by 1,855
Myers, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.0525144 · Cited by 1,232
Self-citationCreatinine: from physiology to clinical application
Kashani, K., Rosner, M. H., & Ostermann, M. (2020) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2019.10.025 · Cited by 474
Matzke, G. R., Aronoff, G. R., Atkinson, A. J., Bennett, W. M., Decker, B. S., Eckardt, K.-U., Golper, T., Grabe, D. W., Kasiske, B., Keller, F., et al. (2011) · Kidney International · doi:10.1038/ki.2011.322 · Cited by 462
Proficiency Testing/External Quality Assessment: Current Challenges and Future Directions
Miller, W. G., Jones, G. R., Horowitz, G. L., & Weykamp, C. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.168641 · Cited by 341
Selvin, E., Manzi, J., Stevens, L. A., Van Lente, F., Lacher, D. A., Levey, A. S., & Coresh, J. (2007) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.08.020 · Cited by 307
Estimated GFR: time for a critical appraisal
Porrini, E., Ruggenenti, P., Luis-Lima, S., Carrara, F., Jiménez, A., de Vries, A. P. J., Torres, A., Gaspari, F., & Remuzzi, G. (2019) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0080-9 · Cited by 294
A comparison of three methods to estimate baseline creatinine for RIFLE classification
Zavada, J., Hoste, E., Cartin-Ceba, R., Calzavacca, P., Gajic, O., Clermont, G., Bellomo, R., Kellum, J. A., & for the AKI6 investigators (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp766 · Cited by 260
Ceriotti, F., Boyd, J. C., Klein, G., Henny, J., Queraltó, J., Kairisto, V., Panteghini, M., & the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL) (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.099648 · Cited by 252
Assessment of Glomerular Filtration Rate in Health and Disease: A State of the Art Review
Levey, A., & Inker, L. (2017) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.729 · Cited by 244
Estimating kidney function in adults using formulae
Lamb, E. J., Tomson, C. R., & Roderick, P. J. (2005) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563054889936 · Cited by 238
Stevens, L. A., Manzi, J., Levey, A. S., Chen, J., Deysher, A. E., Greene, T., Poggio, E. D., Schmid, C. H., Steffes, M. W., Zhang, Y. (., et al. (2007) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.04.004 · Cited by 216
The MELD score in patients awaiting liver transplant: Strengths and weaknesses
Bernardi, M., Gitto, S., & Biselli, M. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.11.008 · Cited by 174
Vickery, S., Stevens, P. E., Dalton, R. N., van Lente, F., & Lamb, E. J. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl249 · Cited by 173
Monitoring Renal Function and Limitations of Renal Function Tests
Prigent, A. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.09.003 · Cited by 170
Serum cystatin C as a marker of glomerular filtration rate
Madero, M., Sarnak, M. J., & Stevens, L. A. (2006) · Current Opinion in Nephrology & Hypertension · doi:10.1097/01.mnh.0000247505.71915.05 · Cited by 167
Cholongitas, E., Marelli, L., Kerry, A., Goodier, D., Nair, D., Thomas, M., Patch, D., & Burroughs, A. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2007.01666.x · Cited by 165
Different Methods of Creatinine Measurement Significantly Affect MELD Scores
Cholongitas, E., Marelli, L., Kerry, A., Senzolo, M., Goodier, D. W., Nair, D., Thomas, M., Patch, D., & Burroughs, A. K. (2007) · Liver Transplantation · doi:10.1002/lt.20994 · Cited by 162
Kidney function estimating equations: where do we stand?
Coresh, J., & Stevens, L. (2006) · Current Opinion in Nephrology and Hypertension · doi:10.1097/01.mnh.0000222695.84464.61 · Cited by 159
Toward standardization of insulin immunoassays
Miller, W. G., Thienpont, L. M., Van Uytfanghe, K., Clark, P. M., Lindstedt, P., Nilsson, G., Steffes, M. W., & for the Insulin Standardization Work Group (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.118380 · Cited by 111
Self-citationMiller, W. G., Myers, G. L., Ashwood, E. R., Killeen, A. A., Wang, E., Ehlers, G. W., Hassemer, D., Lo, S. F., Seccombe, D., Siekmann, L., et al. (2008) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2008-132-838-sotait · Cited by 87
Self-citationSteele, B. W., Wang, E., Klee, G. G., Thienpont, L. M., Soldin, S. J., Sokoll, L. J., Winter, W. E., Fuhrman, S. A., & Elin, R. J. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-310-abotft · Cited by 66
Self-citationWexler, D. J., de Boer, I. H., Ghosh, A., Younes, N., Bebu, I., Inzucchi, S. E., McGill, J. B., Mudaliar, S., Schade, D., Steffes, M. W., et al. (2023) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2023.1487 · Cited by 39
Hepato-renal toxicity of Myristica fragrans Houtt. (Myristicaceae) seed extracts in rats
Anaduaka, E. G., Okagu, I. U., Uchendu, N. O., Ezeanyika, L. U. S., & Nwanguma, B. C. (2022) · Journal of King Saud University - Science · doi:10.1016/j.jksus.2021.101694 · Cited by 12
Heat Impacts on Work, Human Performance, and Daily Life
Kjellstrom, T., Lemke, B., Matthias Otto, P., Hyatt, O. M., Briggs, D. J., & Freyberg, C. A. (2015) · Climate Change and Public Health · doi:10.1093/med/9780190202453.003.0004 · Cited by 9
Metadata
- Authors
- Greg Miller, W., Myers, G. L., Ashwood, E. R., Killeen, A. A., Wang, E., Thienpont, L. M., & Siekmann, L.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2005-03
- Volume
- 129
- Issue
- 3
- Pages
- 297-304
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W1840746889
- Cited by
- 286
- References
- 13
- FWCI
- 13.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.