Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This study assessed validity and reliability of the VO 2 Master Pro portable metabolic analyzer for assessment of oxygen consumption (VO 2 ) and minute ventilation (VE). In Protocol 1, eight male participants (height: 182.6 ± 5.8 cm, weight: 79.6 ± 8.3 kg, age: 41.0 ± 12.3 years) with previous competitive cycling experience completed an hour-long stationary cycling protocol twice, progressing from 100-300 Watts every 10 minutes while wearing the VO 2 Master and a criterion measure (Parvomedics) for five minutes each, at each stage. In Protocol 2, 16 recreationally active male participants (height: 168.2 ± 8.4 cm, weight: 76.5 ± 13.3 kg, age: 23.0 ± 9.4 years) completed three incremental, maximal stationary cycling tests wearing one of three analyzers for each test (VO 2 Master version 1.1.1, VO 2 Master version 1.2.1, Parvomedics). For Protocol 1 and convergent validity, the VO 2 Master had mean absolute differences from the Parvomedics of 2 and 2 and VE were 2 Master (MAPD: 8.9-10.9%) was somewhat poorer than the Parvomedics (MAPD: 5.3-7.6%). For Protocol 2, validity was similar for both VO 2 Master models (MAPD ~12% overall) compared to the Parvomedics for VO 2 and VE. The VO 2 Master had an acceptable validity and test-retest reliability for most intensities tested and may be an appealing option for field-based VO 2 and VE analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their results showed excellent test–retest reliability scores, with CV less than 5% as seen in our results (36).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [36]
In the citing paper
“Both of these measures have shown a wide range of reliability scores during incremental exercise tests (32–34, 36, 37).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [36]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580 · cited 1×
“, every 5 minutes), steady-state heart rate and rating of perceived exertion (Borg 6-20 scale) were recorded (3).”
BackgroundA new predictive equation for resting energy expenditure in healthy individuals
Mifflin, M., St Jeor, S., Hill, L., Scott, B., Daugherty, S., & Koh, Y. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.241 · Cited by 2,544
Physiology of Sport and Exercise
Wilmore, J. H., Costill, D. L., & Gleim, G. W. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199505000-00024 · Cited by 2,174 · cited 1×
“Full analysis of caloric expenditure and macronutrient fuel utilization requires measurement of both VO2 and carbon dioxide consumption (VCO2) for determination of respiratory exchange ratio (12).”
BackgroundA biometric study of human basal metabolism
Harris, J. A., & Benedict, F. G. (1918) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.4.12.370 · Cited by 1,980 · cited 2×
“Even without VCO2 measurement, such devices have been shown to provide more accurate measures of resting caloric expenditure than popular equations such as the Harris-Benedict (9) or Mifflin St.”
MethodGlickman, M. E., Rao, S. R., & Schultz, M. R. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.03.012 · Cited by 1,542 · cited 1×
“1) were compared using repeated-measures analysis of variance (RMANOVA) with a false discovery rate correction for multiple comparisons (7); a p value of p<0.”
MethodEthical Issues Relating to Scientific Discovery in Exercise Science
Navalta, J. W., & Stone, W. J. (2019) · International Journal of Exercise Science · doi:10.70252/eycd6235 · Cited by 679 · cited 2×
“This protocol was also approved by the college’s Institutional Review Board approved and was carried out fully in accordance to the ethical standards of the International Journal of Exercise Science (22).”
MethodValidation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374 · cited 1×
“(18) found that the COSMED K4b2 significantly overestimated absolute VO2 by ~0.”
BackgroundAccuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246 · cited 1×
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodValidity of Consumer-Based Physical Activity Monitors for Specific Activity Types
NELSON, M. B., KAMINSKY, L. A., DICKIN, D. C., & MONTOYE, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 205
Self-citationEvaluation of the Oxycon Mobile metabolic system against the Douglas bag method
Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1326-9 · Cited by 181 · cited 2×
“8%) (26) and MetaMax (coefficients of variation 5.”
Background
Cited by
van Hooren, B., Souren, T., & Bongers, B. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14490 · Cited by 112
“26 Such findings are in partial agreement with our findings as we found a consistent underestimation during the simulation experiments, with this difference becoming larger at higher simulated values.”
ResultYogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
Wiecha, S., Kasiak, P., Szwed, P., Kowalski, T., Cieśliński, I., Postula, M., & Klusiewicz, A. (2023) · bioRxiv · doi:10.1101/2023.02.03.527004 · Cited by 30
“However, with the development of technology, the accessibility of laboratory testing and mobile testing improved (Montoye et al., 2020; Pritchard et al., 2021).”
BackgroundA multidevice and multimodal dataset for human energy expenditure estimation using wearable devices
Gashi, S., Min, C., Montanari, A., Santini, S., & Kawsar, F. (2022) · Scientific Data · doi:10.1038/s41597-022-01643-5 · Cited by 29
Physiological and Mechanical Responses to a Graded Exercise Test in Traditional Rowing
Penichet-Tomás, A., Jiménez-Olmedo, J. M., Pueo, B., & Olaya-Cuartero, J. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20043664 · Cited by 21
“, Vernon, BC, Canada) was used to measure cardiorespiratory parameters [46].”
MethodDasa, M., Friborg, O., Kristoffersen, M., Pettersen, G., Sundgot-Borgen, J., & Rosenvinge, J. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19084770 · Cited by 18
“The VO2 master have previously been validated [29] resulting in a difference ranging from 0.”
BackgroundWang, Z., Zhang, Q., Lan, K., Yang, Z., Gao, X., Wu, A., Yi, X., & Zhang, Z. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.897412 · Cited by 17
“, 2018), VO2 Master (Montoye et al., 2020) and Jaeger (Díaz et al.”
BackgroundCaserman, P., Yum, S., Göbel, S., Reif, A., & Matura, S. (2024) · JMIR Biomedical Engineering · doi:10.2196/59459 · Cited by 16
“Evidence of the measurement accuracy of the hardware used can be found in references [45,46].”
Thiessen, J. S., Guluzade, N. A., Faricier, R., & Keir, D. (2025) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.70019 · Cited by 16
Evaluation of an articulated passive ankle–foot prosthesis
Lathouwers, E., Ampe, T., Díaz, M., Meeusen, R., & de Pauw, K. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-00997-6 · Cited by 9
Kimura, Y., Suzuki, Y., Kubo, H., Yoshida, K., Ota, T., Shimizu, N., & Kanai, M. (2025) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2024.1496515 · Cited by 9
Psychophysiological Data Harmonization for the Sustainability of Outdoor Activities
Papale, O., Festino, E., Condello, G., Rocco, F. D., Maio, M. D., Cortis, C., & Fusco, A. (2023) · Sustainability · doi:10.3390/su152215838 · Cited by 13
Feasibility of a Novel Augmented 6-Minute Incremental Step Test
Molinger, J., Kittipibul, V., Gray, J. M., Rao, V. N., Barth, S., Swavely, A. G., Coyne, B., Coburn, A., Bakker, J., Wischmeyer, P. E., et al. (2024) · JACC: Advances · doi:10.1016/j.jacadv.2024.101079 · Cited by 5
Comparison of the VO2 Master Pro and Cosmed K5 During Walking, Jogging, and Running
Toulouse, A., Joubert, D. P., Oden, G., & Davis, P. (2021) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-021-00146-w · Cited by 5
“Recently, the VM was compared with Parvomedics TrueOne 2400 metabolic cart during stationary indoor cycling [8].”
BackgroundResultInfluentialEnergy expenditure compared to mental focus & score in three modes of golf transport/play
Wolkodoff, N., Haase, G., & Pennymon, B. N. (2022) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2022.16.3.1403 · Cited by 4
“Beta testing with four sessions with one subject revealed that the VO2 Master had the same O2 and primary respiratory data over test holes [10], but with less encumbrance and interference with the golf swing than the OxyconMobile.”
van Hooren, B., Souren, T., Miqueu, F., & Bongers, B. (2026) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.70184 · Cited by 4
The reliability of the VO2 Master Pro metabolic analyzer and comparison with the Cosmed Quark
Davis, P. (2024) · Science & Sports · doi:10.1016/j.scispo.2024.03.002 · Cited by 4
Ciuha, U., Podgornik, S., Fisher, J. T., Marolt, B., & Mekjavić, I. B. (2024) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2024.104014 · Cited by 3
Evaluation of Air Consumption Efficiency in Structural Firefighters
Langford, E. L., Bergstrom, H. C., Lanham, S. N., Eastman, A. Q., Best, S. A., Ma, X., & Abel, M. G. (2024) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000003202 · Cited by 4
Vasquez-Bonilla, A. A., Sepulveda, R. A. Y., Monsalves‐Álvarez, M., Tuesta, M., Bastías, D. M. D., Cortés-Roco, G., Arancibia, J. E. O., Guzmán-Muñoz, E., & López‐Gil, J. F. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10020136 · Cited by 5
Theacrine as a novel ergogenic aid: impact on canoe sprint performance
Jovanov, P., Vraneš, M., Barak, O., Rapaić, M., Maravić, N., Marić, A., & Obradović, B. (2025) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2025.2590097 · Cited by 2
“All VO 2 outcomes were normalized to body mass (mL·kg −1 ·min −1 ) to allow for comparison between athletes [32].”
A Low-cost IoT Mobile System for Monitoring Vital Signs of Elderly People
Matsuo, Â. K., Guterres, B. A., Colares, N. D., Pessoa, O. N., Santos, A. E., Luiz, D., Carvalho, C. B., & Waldir, S. S. (2022) · International Workshop on Secure Internet of Things · doi:10.1109/siot56383.2022.10070332 · Cited by 2
“The BMP180 identifies the environmental temperature and atmospheric pressure and it is compared to the FanJu weather station [11].”
BackgroundThe self-selected intensity of physical activity during real-life e-bike commuting
Riiser, A., Aadland, E., & Nordengen, S. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2025.1653833 · Cited by 1
“Although our portable oxygen analyser has shown considerable day-to-day variation in VO 2 measurements (40), it exhibited no difference between indoor and outdoor measurements (41).”
Quiblier, S. P. H., García-Pérez-de-Sevilla, G., Santiago, C., Iturriaga, T., Benítez-Valero, R., Revuelta, C., Carrasco, A. F., & Domínguez-Balmaseda, D. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2026.1768915 · Cited by 1
“…real-time gas exchange (O 2 and CO 2 ) during exercise, allowing for precise determination of VO 2 max by analyzing oxygen consumption and carbon dioxide production, as highlighted by the articles that demonstrate its validity and reliability comparable to standard laboratory methods (38, 39).”
Evaluating High-Intensity Interval-Training Validity Using Critical Power in Rowing.
Dicks, N., Phuaklee, P., Ketterling, J. J., & Pettitt, R. (2025) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2025-0174 · Cited by 1
Hartman, M., Kantor, M., Thornhill, K., Reiner, S. L., Winn, B. J., Kramer, M., Pettitt, R., & Kirby, B. S. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003771 · Cited by 1
“Pulmonary O 2 uptake was measured using a portable gas analyzer ( ˙ VO 2 Master; ˙ VO 2 Master Health Sensors Inc., Vernon, BC, Canada) (56), which was calibrated before each test according to the man-ufacturer ’ s guidelines.”
Chassé, É., Théoret, D., Poirier, M. P., & Lalonde, F. (2021) · Military Medicine · doi:10.1093/milmed/usab421 · Cited by 1
Soldier load carriage: Does the type of pack matter?
Orr, R., Rousseau, J., Canetti, E., & Schram, B. (2026) · Applied Ergonomics · doi:10.1016/j.apergo.2026.104733 · Cited by 1
Sex Differences in the Metabolic Cost of a Military Load Carriage Task: A Field Based Study
Schram, B., Rosseau, J., Canetti, E., & Orr, R. (2025) · Sports · doi:10.3390/sports13120442 · Cited by 1
“VO 2 Measures: VO 2 is a measure of the ability of the body to uptake, transport, and utilise oxygen and is a useful measure of aerobic fitness [31].”
Aerobic Fitness Level Estimation Using Wearables
Smíšek, R., Němcová, A., Smital, L., Chlíbková, D., Králik, M., Kolářová, J., Myska, V., Kolařík, M., Harvanek, M., Arm, J., et al. (2022) · 2022 Computing in Cardiology (CinC) · doi:10.22489/cinc.2022.302 · Cited by 1
“With the help of this mask, it is possible to continuously measure oxygen consumption during movement and then predict the maximum oxygen consumption from these values [5].”
BackgroundKim, D.-H., Yang, G., & Park, S.-B. (2026) · PeerJ · doi:10.7717/peerj.20948
Adams, T., Cameron, H. L., Tingelstad, H. C., Belgiorgio, M., & Reilly, T. (2026) · Prehospital Emergency Care · doi:10.1080/10903127.2026.2628839
“…of 0.6% and mean absolute percent difference of 11.9%, as well as its test-retest reliability, with corresponding values of 1.2 and 10.9%, when compared to established metabolic measurement systems such as metabolic carts and the Douglas Bag method during controlled exercise protocols (36,37).”
InfluentialHarding, M. C., Case, J., Knighton, K., Babun, A. A., & Brooks, B. D. (2026) · Healthcare · doi:10.3390/healthcare14183070
“VO 2 peak was measured via indirect calorimetry using the VO 2 Master device, a validated wearable metabolic analyzer (VO 2 Master Health Sensors Inc., Vernon, BC, Canada) [9,10].”
Federico, R. J., Caba-Abreu, T. A., Pigman, J., & Rebullido, T. (2026) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk11040385
“The VO 2 Master Pro has previously shown acceptable validity and test–retest reliability for ventilatory assessment [17,18].”
Wolkodoff, N., Haase, G., & Kapteyn, R. W. (2023) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2023.18.3.1014
“The subjects were measured for metabolic response during those nine-hole rounds with a VO2 Master portable analyzer [42], (Figure 1, Figure 2).”
MethodThe validity of the VO2 master pro for assessing VO2max and running economy in trained runners
Domny, T. A., Phillips, A. D., Tibbs, K., Gilmore, B., Phillips, J. P., O'Neal, E. K., & André, T. (2026) · Scientific Journal of Sport and Performance · doi:10.55860/mzvi6493
“This aligns with previous research that reported larger discrepancies in VO 2 at higher exercise intensities (Montoye et al., 2020; Van Hooren et al., 2026).”
InfluentialGas Sensing Technologies and Algorithms for Measurement of Energy Expenditure in Humans: A Review
Shi, Y., & Guan, X. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3651626
“Evidence suggests that the VO 2 Master maintains acceptable validity and test–retest reliability at the majority of exercise intensities [43].”
Jones, M., Smith, G., Acevedo, A. M., & Melton, B. F. (2026) · Journal of Exercise and Nutrition · doi:10.53520/jen2026.103232
“…demonstrated strong agreement between the VO 2 Master and laboratory based metabolic carts, with reported correlations ranging from r = 0.93 to 0.97 relative to the ParvoMedics TrueOne 2400, absolute mean differences below 10% for VO ₂ , and coefficients of variation between 11.4% and 15.1% 46 .”
InfluentialDias, K., Readnour, E., Stone, A., Bistrain-Diaz, K., King, E., Reed, P. J., II, Fick, A., & Nadler, D. R. (2026) · Home Healthcare Now · doi:10.1097/nhh.0000000000001470
Leveque, C., Theunissen, S., Ezquer, M., Hayot, E., Lambrechts, K., & Balestra, C. (2026) · Spinal Cord · doi:10.1038/s41393-026-01239-5
“The VO ₂ Master Pro has shown high validity and reliability during fi eld-based maximal testing (validity r = 0.97; reliability r > 0.96) [19].”
InfluentialPark, S.-H., Kim, H., & Lee, M.-G. (2026) · Experimental Physiology · doi:10.1113/ep093890
Energy expenditure of golf range practice: A beta investigation
Wolkodoff, N., Moran, M. P., Pennymon, B. N., Curry, J., & Haase, G. (2024) · World Journal of Advanced Research and Reviews · doi:10.30574/wjarr.2024.24.2.3505
Metadata
- Authors
- Montoye, A. H. K., Vondrasek, J. D., & Hancock, J.
- Affiliations
- Alma College (US)
- Venue
- International Journal of Exercise Science
- Published
- 2020
- Volume
- 13
- Issue
- 4
- Pages
- 1382-1401
- ISSN
- 1939-795X (ISSN-L)
- PMC
- PMC7523887
- OpenAlex
- W3086820962
- Semantic Scholar
- 76e16551d473691040e028a9db904d1732c43eec
- Cited by
- 39
- References
- 29
- Citations by year
- 2026: 11 · 2025: 7 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 2
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nd
- Locations
- International journal of exercise science (publishedVersion, cc-by-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- TopSCHOLAR (Western Kentucky University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- oxygen consumption, minute ventilation, validity, test-retest reliability, incremental cycling test, stationary cycling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.