Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This study assessed validity and reliability of the VO 2 Master Pro portable metabolic analyzer for assessment of oxygen consumption (VO 2 ) and minute ventilation (VE). In Protocol 1, eight male participants (height: 182.6 ± 5.8 cm, weight: 79.6 ± 8.3 kg, age: 41.0 ± 12.3 years) with previous competitive cycling experience completed an hour-long stationary cycling protocol twice, progressing from 100-300 Watts every 10 minutes while wearing the VO 2 Master and a criterion measure (Parvomedics) for five minutes each, at each stage. In Protocol 2, 16 recreationally active male participants (height: 168.2 ± 8.4 cm, weight: 76.5 ± 13.3 kg, age: 23.0 ± 9.4 years) completed three incremental, maximal stationary cycling tests wearing one of three analyzers for each test (VO 2 Master version 1.1.1, VO 2 Master version 1.2.1, Parvomedics). For Protocol 1 and convergent validity, the VO 2 Master had mean absolute differences from the Parvomedics of 2 and 2 and VE were 2 Master (MAPD: 8.9-10.9%) was somewhat poorer than the Parvomedics (MAPD: 5.3-7.6%). For Protocol 2, validity was similar for both VO 2 Master models (MAPD ~12% overall) compared to the Parvomedics for VO 2 and VE. The VO 2 Master had an acceptable validity and test-retest reliability for most intensities tested and may be an appealing option for field-based VO 2 and VE analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their results showed excellent test–retest reliability scores, with CV less than 5% as seen in our results (36).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [36]
In the citing paper
“Both of these measures have shown a wide range of reliability scores during incremental exercise tests (32–34, 36, 37).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [36]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580 · cited 1×
“, every 5 minutes), steady-state heart rate and rating of perceived exertion (Borg 6-20 scale) were recorded (3).”
BackgroundA new predictive equation for resting energy expenditure in healthy individuals
Mifflin, M., St Jeor, S., Hill, L., Scott, B., Daugherty, S., & Koh, Y. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.241 · Cited by 2,544
Physiology of Sport and Exercise
Wilmore, J. H., Costill, D. L., & Gleim, G. W. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199505000-00024 · Cited by 2,174 · cited 1×
“Full analysis of caloric expenditure and macronutrient fuel utilization requires measurement of both VO2 and carbon dioxide consumption (VCO2) for determination of respiratory exchange ratio (12).”
BackgroundA biometric study of human basal metabolism
Harris, J. A., & Benedict, F. G. (1918) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.4.12.370 · Cited by 1,980 · cited 2×
“Even without VCO2 measurement, such devices have been shown to provide more accurate measures of resting caloric expenditure than popular equations such as the Harris-Benedict (9) or Mifflin St.”
MethodGlickman, M. E., Rao, S. R., & Schultz, M. R. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.03.012 · Cited by 1,542 · cited 1×
“1) were compared using repeated-measures analysis of variance (RMANOVA) with a false discovery rate correction for multiple comparisons (7); a p value of p<0.”
MethodEthical Issues Relating to Scientific Discovery in Exercise Science
Navalta, J. W., & Stone, W. J. (2019) · International Journal of Exercise Science · doi:10.70252/eycd6235 · Cited by 679 · cited 2×
“This protocol was also approved by the college’s Institutional Review Board approved and was carried out fully in accordance to the ethical standards of the International Journal of Exercise Science (22).”
MethodValidation of the COSMED K4 b2 Portable Metabolic System
McLaughlin, J. E., King, G. A., Howley, E. T., Bassett, Jr., & Ainsworth, B. E. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-13816 · Cited by 374 · cited 1×
“(18) found that the COSMED K4b2 significantly overestimated absolute VO2 by ~0.”
BackgroundAccuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246 · cited 1×
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodValidity of Consumer-Based Physical Activity Monitors for Specific Activity Types
NELSON, M. B., KAMINSKY, L. A., DICKIN, D. C., & MONTOYE, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 205
Self-citationEvaluation of the Oxycon Mobile metabolic system against the Douglas bag method
Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1326-9 · Cited by 181 · cited 2×
“8%) (26) and MetaMax (coefficients of variation 5.”
BackgroundValidity, reliability and stability of the portable Cortex Metamax 3B gas analysis system
Macfarlane, D. J., & Wong, P. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2230-7 · Cited by 167
Validity and reliability of the Cortex MetaMax3B portable metabolic system
Vogler, A. J., Rice, A. J., & Gore, C. J. (2010) · Journal of Sports Sciences · doi:10.1080/02640410903582776 · Cited by 134
Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems
Meyer, T., Georg, T., Becker, C., & Kindermann, W. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-18523 · Cited by 131 · cited 1×
“99) (2, 20, 25) are similar to that of the COSMED.”
ResultGuidetti, L., Meucci, M., Bolletta, F., Emerenziani, G., Gallotta, M., & Baldari, C. (2018) · PLoS ONE · doi:10.1371/journal.pone.0209925 · Cited by 121 · cited 1×
“(8) with the COSMED K5 found mean absolute errors of <1% and correlations of r>0.”
MethodValidity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.218 · Cited by 118 · cited 1×
“Previous research has shown the Parvomedics to accurately measure both VO2 and ventilation across a range of intensities compared to the gold-standard Douglas bag method, rendering the Parvomedics a suitable criterion measure for comparison in this study (1).”
MethodValidity and Reliability of the Cosmed K2 Instrument
Lucía, A., Fleck, S., Gotshall, R., & Kearney, J. (1993) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021196 · Cited by 95 · cited 3×
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodValidation of the portable VmaxST system for oxygen-uptake measurement.
Brehm, M., Harlaar, J., & Groepenhof, H. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00097-3 · Cited by 94 · cited 2×
“Int J Exerc Sci 13(4): 1382-1401, 2020”
BackgroundOpen-circuit respirometry: a historical review of portable gas analysis systems
Macfarlane, D. J. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3716-8 · Cited by 83 · cited 1×
“com 1383 for important metabolic and caloric expenditure analyses to be performed in field-based settings (15).”
BackgroundAmbulatory Gas Exchange Measurements - Current Status and Future Options
Meyer, T., Davison, R., & Kindermann, W. (2004) · International Journal of Sports Medicine · doi:10.1055/s-2004-830507 · Cited by 82 · cited 1×
“Brands of portable analyzers including COSMED, Oxycon, and MetaMax have received extensive validation and field use in a variety of settings, providing evidence of the importance of capturing such field-based data (19, 24).”
BackgroundDarter, B. J., Rodriguez, K. M., & Wilken, J. (2013) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2013.784720 · Cited by 69 · cited 1×
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodReliability of measurement of oxygen uptake by a portable telemetric system
Kawakami, Y., Nozaki, D., Matsuo, A., & Fukunaga, T. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00243506 · Cited by 65 · cited 1×
“(11) found that the COSMED K2 had absolute VO2 measures 0.”
BackgroundA New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure
St‐Onge, M., Rubiano, F., Jones, A., & Heymsfield, S. B. (2004) · Obesity Research · doi:10.1038/oby.2004.82 · Cited by 62
Hipskind, P., Glass, C., Charlton, D., Nowak, D., & Dasarathy, S. (2011) · Nutrition in Clinical Practice · doi:10.1177/0884533611411272 · Cited by 62 · cited 1×
“Accordingly, such devices may have utility for measuring resting caloric expenditure and metabolic rate in weight-loss or hospital settings (10).”
BackgroundPortable open-circuit spirometry systems
Overstreet, B. S., Bassett Jr., D. R., Crouter, S. E., Rider, B. C., & Parr, B. B. (2017) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.16.06049-7 · Cited by 48 · cited 1×
“Brands of portable analyzers including COSMED, Oxycon, and MetaMax have received extensive validation and field use in a variety of settings, providing evidence of the importance of capturing such field-based data (19, 24).”
BackgroundThomas, S., Buckon, C., Schwartz, M. H., Russman, B., Sussman, M. D., & Aiona, M. (2009) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2008.03214.x · Cited by 37 · cited 2×
“96 for metabolic variables assessed with various COSMED models (5, 6, 14, 29).”
MethodValidity and Reliability of the Cosmed K2 to Measure Oxygen Uptake
Lothian, F., Farrally, M. R., & Mahoney, C. (1993) · Canadian Journal of Applied Physiology · doi:10.1139/h93-016 · Cited by 36 · cited 2×
“Past work with the COSMED K2 and K4b2 found coefficients of variation of ~3-13% for VO2 and minute ventilation variables during submaximal and maximal exercise (13, 14, 29), and these are slightly better than the 11.”
MethodRubenbauer, J. R., Johannsen, D., Baier, S., Litchfield, R., & Flakoll, P. (2006) · JPEN - Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607106030003246 · Cited by 22
Reliability of the VmaxST portable metabolic measurement system
Blessinger, J., Sawyer, B. J., Davis, C., Irving, B., Weltman, A., & Gaesser, G. (2008) · International Journal of Sports Medicine · doi:10.1055/s-2008-1038744 · Cited by 18 · cited 1×
“99) (2, 20, 25) are similar to that of the COSMED.”
ResultReliability and Validity of the VmaxST Portable Metabolic Analyzer
Perkins, C. D., Pivarnik, J., & Green, M. R. (2004) · Journal of Physical Activity and Health · doi:10.1123/jpah.1.4.413 · Cited by 12 · cited 1×
“99) (2, 20, 25) are similar to that of the COSMED.”
Result
Cited by
van Hooren, B., Souren, T., & Bongers, B. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14490 · Cited by 112
“26 Such findings are in partial agreement with our findings as we found a consistent underestimation during the simulation experiments, with this difference becoming larger at higher simulated values.”
ResultYogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
Wiecha, S., Kasiak, P., Szwed, P., Kowalski, T., Cieśliński, I., Postula, M., & Klusiewicz, A. (2023) · bioRxiv · doi:10.1101/2023.02.03.527004 · Cited by 30
“However, with the development of technology, the accessibility of laboratory testing and mobile testing improved (Montoye et al., 2020; Pritchard et al., 2021).”
BackgroundA multidevice and multimodal dataset for human energy expenditure estimation using wearable devices
Gashi, S., Min, C., Montanari, A., Santini, S., & Kawsar, F. (2022) · Scientific Data · doi:10.1038/s41597-022-01643-5 · Cited by 29
Physiological and Mechanical Responses to a Graded Exercise Test in Traditional Rowing
Penichet-Tomás, A., Jiménez-Olmedo, J. M., Pueo, B., & Olaya-Cuartero, J. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20043664 · Cited by 21
“, Vernon, BC, Canada) was used to measure cardiorespiratory parameters [46].”
Method
Metadata
- Authors
- Montoye, A. H. K., Vondrasek, J. D., & Hancock, J.
- Affiliations
- Alma College (US)
- Venue
- International Journal of Exercise Science
- Published
- 2020
- Volume
- 13
- Issue
- 4
- Pages
- 1382-1401
- ISSN
- 1939-795X (ISSN-L)
- PMC
- PMC7523887
- OpenAlex
- W3086820962
- Semantic Scholar
- 76e16551d473691040e028a9db904d1732c43eec
- Cited by
- 39
- References
- 29
- Citations by year
- 2026: 11 · 2025: 7 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 2
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nd
- Locations
- International journal of exercise science (publishedVersion, cc-by-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- TopSCHOLAR (Western Kentucky University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- oxygen consumption, minute ventilation, validity, test-retest reliability, incremental cycling test, stationary cycling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.