CoChat

Image-guided surgery using near-infrared Turn-ON fluorescent nanoprobes for precise detection of tumor margins

Open access
Blau, Rachel, Epshtein, Yana, Pisarevsky, Evgeni, Tiram, Galia, Dangoor, Sahar Israeli, Yeini, Eilam, Krivitsky, Adva, Eldar-Boock, Anat, Ben-Shushan, Dikla, Gibori, Hadas, Scomparin, Anna, Green, Ori, Ben-Nun, Yael, Merquiol, Emmanuelle, Doron, Hila, Blum, Galia, Erez, Neta, Grossman, Rachel, Ram, Zvi, Shabat, Doron, Satchi-Fainaro, Ronit · 2018 · Theranostics
Cited by 71

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Complete tumor removal during surgery has a great impact on patient survival.To that end, the surgeon should detect the tumor, remove it and validate that there are no residual cancer cells left behind.Residual cells at the incision margin of the tissue removed during surgery are associated with tumor recurrence and poor prognosis for the patient.In order to remove the tumor tissue completely with minimal collateral damage to healthy tissue, there is a need for diagnostic tools that will differentiate between the tumor and its normal surroundings.Methods: We designed, synthesized and characterized three novel polymeric Turn-ON probes that will be activated at the tumor site by cysteine cathepsins that are highly expressed in multiple tumor types.Utilizing orthotopic breast cancer and melanoma models, which spontaneously metastasize to the brain, we studied the kinetics of our polymeric Turn-ON nano-probes.Results: To date, numerous low molecular weight cathepsin-sensitive substrates have been reported, however, most of them suffer from rapid clearance and reduced signal shortly after administration.Here, we show an improved tumor-to-background ratio upon activation of our Turn-ON probes by cathepsins.The signal obtained from the tumor was stable and delineated the tumor boundaries during the whole surgical procedure, enabling accurate resection.Conclusions: Our findings show that the control groups of tumor-bearing mice, which underwent either standard surgery under white light only or under the fluorescence guidance of the commercially-available imaging agents ProSense® 680 or 5-aminolevulinic acid (5-ALA), survived for less time and suffered from tumor recurrence earlier than the group that underwent image-guided surgery (IGS) using our Turn-ON probes.Our "smart" polymeric probes can potentially assist surgeons' decision in real-time during surgery regarding the tumor margins needed to be removed, leading to improved patient outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7150/thno.23853

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 71

Metadata

Authors
Blau, R., Epshtein, Y., Pisarevsky, E., Tiram, G., Dangoor, S. I., Yeini, E., Krivitsky, A., Eldar-Boock, A., Ben-Shushan, D., Gibori, H., Scomparin, A., Green, O., Ben-Nun, Y., Merquiol, E., Doron, H., Blum, G., Erez, N., Grossman, R., Ram, Z., Shabat, D., & Satchi-Fainaro, R.
Venue
Theranostics
Published
2018
Volume
8
Issue
13
Pages
3437-3460
ISSN
1838-7640 (ISSN-L)
OpenAlex
W2806423326
Cited by
71
References
3
FWCI
3.30
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Image-guided surgery using near-infrared Turn-ON fluorescent nanoprobes for precise detection of tumor margins. https://app.cochat.ai/papers/10.7150/thno.23853
The paper
Blau, R., Epshtein, Y., Pisarevsky, E., Tiram, G., Dangoor, S. I., Yeini, E., Krivitsky, A., Eldar-Boock, A., Ben-Shushan, D., Gibori, H., Scomparin, A., Green, O., Ben-Nun, Y., Merquiol, E., Doron, H., Blum, G., Erez, N., Grossman, R., Ram, Z., . . . Satchi-Fainaro, R. (2018). Image-guided surgery using near-infrared Turn-ON fluorescent nanoprobes for precise detection of tumor margins. Theranostics. https://doi.org/10.7150/thno.23853

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.