Low-intensity focused ultrasound for the treatment of brain diseases: safety and feasibility
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The use of focused ultrasound (FUS) as a tool for blood-brain barrier (BBB) permeabilization is opening new ways for the treatment of several pathologies, in particular brain tumors and neurodegenerative diseases. However, even if there are promising results in these fields, the efficacy and safety of this technique is unknown in long-term follow-up. The study of Blackmore et al. [Theranostics 2018; 8(22):6233-6247. doi:10.7150/thno.27941] evaluated the long-term effects of FUS on brain parenchyma in aged mice with Alzheimer's disease. This is the first study which applied a multimodal analysis to demonstrate the safety of FUS in aged brain in view of a potential introduction of this technique in common clinical practice in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498 · cited 1×
“The anti-amyloid effect is confirmed by other studies that showed a significant improvement of cognitive tasks in tested animals and, at the same time, a reduction in β-amyloid plaques and an improvement of neurogenesis in the sonicated brain areas [6, 7, 8, 9].”
ResultJordão, J. F., Thévenot, E., Markham-Coultes, K., Scarcelli, T., Weng, Y.-Q., Xhima, K., O'Reilly, M., Huang, Y., McLaurin, J., Hynynen, K., et al. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2013.05.008 · Cited by 326
Burgess, A., Dubey, S., Yeung, S., Hough, O., Eterman, N., Aubert, I., & Hynynen, K. (2014) · Radiology · doi:10.1148/radiol.14140245 · Cited by 286 · cited 1×
“The anti-amyloid effect is confirmed by other studies that showed a significant improvement of cognitive tasks in tested animals and, at the same time, a reduction in β-amyloid plaques and an improvement of neurogenesis in the sonicated brain areas [6, 7, 8, 9].”
Result
Cited by
Nanomaterial-based blood-brain-barrier (BBB) crossing strategies
Xie, J., Shen, Z., Anraku, Y., Kataoka, K., & Chen, X. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119491 · Cited by 604
Nanomaterial based drug delivery systems for the treatment of neurodegenerative diseases
Masoudi Asil, S., Ahlawat, J., Guillama Barroso, G., & Narayan, M. (2020) · Biomaterials Science · doi:10.1039/d0bm00809e · Cited by 181
The barrier and interface mechanisms of the brain barrier, and brain drug delivery
Zhang, S., Gan, L., Cao, F., Wang, H., Gong, P., Ma, C., Ren, L., Lin, Y., & Lin, X. (2022) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2022.09.017 · Cited by 129
Dong, M., Wen, S., & Zhou, L. (2022) · Diabetes, Metabolic Syndrome and Obesity: Targets and Therapy · doi:10.2147/dmso.s375559 · Cited by 90
Desale, S. H., Doshi, P. P., Khutale, A. A., & Suresh, S. (2026) · Ageing Research Reviews · doi:10.1016/j.arr.2026.103379
Metadata
- Authors
- Toccaceli, G., Barbagallo, G., & Peschillo, S.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2019
- Volume
- 9
- Issue
- 2
- Pages
- 537-539
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2910025229
- Cited by
- 39
- References
- 3
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-intensity focused ultrasound for the treatment of brain diseases: safety and feasibility. https://app.cochat.ai/papers/10.7150/thno.31765
- The paper
- Toccaceli, G., Barbagallo, G., & Peschillo, S. (2019). Low-intensity focused ultrasound for the treatment of brain diseases: safety and feasibility. Theranostics. https://doi.org/10.7150/thno.31765
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.