CoChat

Home Monitoring Service Improves Mean Arterial Pressure in Patients with Essential Hypertension: A Randomized, Controlled Trial

Rogers, Mary A.M., Small, David, Buchan, Debra A., Butch, Carl A., Stewart, Christine M., Krenzer, Barbara E., Husovsky, Harold L. · 2001 · Annals of Internal Medicine
Cited by 246

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Technological advances in the distribution of information have opened new avenues for patient care. Few trials, however, have used telemedicine to improve blood pressure in patients with essential hypertension. OBJECTIVE: To determine the efficacy of a telecommunication service in reducing blood pressure. DESIGN: Randomized, controlled trial. SETTING: University-affiliated primary care outpatient clinics. PATIENTS: 121 adults with essential hypertension who were under evaluation for a change in antihypertensive therapy. INTERVENTION: A home service consisting of automatic transmission of blood pressure data over telephone lines, computerized conversion of the information into report forms, and weekly electronic transmission of the report forms to physicians and patients. MEASUREMENTS: 24-hour ambulatory blood pressure monitoring at baseline and exit. The primary end point was change in mean arterial pressure from baseline to exit. RESULTS: Mean arterial pressure decreased by 2.8 mm Hg in patients receiving the home service and increased by 1.3 mm Hg in patients receiving usual care (P = 0.013 for the difference). Mean diastolic blood pressure decreased by 2.0 mm Hg for home service but increased by 2.1 mm Hg for usual care (P = 0.012 for the difference). Mean systolic blood pressure decreased by 4.9 mm Hg for home service and 0.1 mm Hg for patients receiving usual care (P = 0.047 for the difference). Among African-American patients, mean arterial pressure decreased by 9.6 mm Hg in those receiving home service and increased by 5.25 mm Hg in those receiving usual care (P = 0.047). Part of the decrease in blood pressure for home service was due to more frequent changes in the type or dose of antihypertensive medications. CONCLUSION: This telecommunication service was efficacious in reducing the mean arterial pressure of patients with established essential hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-134-11-200106050-00008

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 246

Metadata

Authors
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L.
Venue
Annals of Internal Medicine
Published
2001-06-05
Volume
134
Issue
11
Pages
1024-1032
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2030456275
Cited by
246
References
12
FWCI
11.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home Monitoring Service Improves Mean Arterial Pressure in Patients with Essential Hypertension: A Randomized, Controlled Trial. https://app.cochat.ai/papers/10.7326/0003-4819-134-11-200106050-00008
The paper
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L. (2001). Home Monitoring Service Improves Mean Arterial Pressure in Patients with Essential Hypertension: A Randomized, Controlled Trial. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-134-11-200106050-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.