QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 2,201–2,300 of 14,770
Beckers, R. C. J., Lambregts, D. M. J., Lahaye, M. J., Rao, S., Kleinen, K., Grootscholten, C., Beets, G. L., Beets‐Tan, R. G. H., & Maas, M. (2017) · HPB · doi:10.1016/j.hpb.2017.10.013 · Cited by 66
Swift, B. E., Shah, P. S., & Farine, D. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13585 · Cited by 61
Ding, X., Zhang, S., Jiang, L., Wang, L., Li, T., & Lei, P. (2021) · Translational Neurodegeneration · doi:10.1186/s40035-021-00234-5 · Cited by 69
Tayfur, A., Haque, A., Salles, J. I., Malliaras, P., Screen, H. R. C., & Morrissey, D. (2021) · Sports Medicine · doi:10.1007/s40279-021-01550-6 · Cited by 71
Robotics in neurointerventional surgery: a systematic review of the literature
Crinnion, W., Jackson, B., Sood, A., Lynch, J., Bergeles, C., Liu, H., Rhode, K., Pereira, V. M., & Booth, T. C. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2021-018096 · Cited by 61
“The articles are listed in table 2 which detail the number of patients treated, robotic system used, and the procedural stages that were manually and robotically performed.”
Wilson, S., Ctori, I., Shah, R., Suttle, C., & Conway, M. L. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13022 · Cited by 64
“38 This assessment tool has undergone evaluation to ensure validity and usefulness.”
Ahmadi, S., Sarveazad, A., Babahajian, A., Ahmadzadeh, K., & Yousefifard, M. (2022) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-022-02111-w · Cited by 61
Diffusion Imaging of Sport-related Repetitive Head Impacts—A Systematic Review
Koerte, I. K., Wiegand, T. L. T., Bonke, E. M., Kochsiek, J., & Shenton, M. E. (2022) · Neuropsychology Review · doi:10.1007/s11065-022-09566-z · Cited by 63
Charoensappakit, A., Sae‐khow, K., Rattanaliam, P., Vutthikraivit, N., Pecheenbuvan, M., Udomkarnjananun, S., & Leelahavanichkul, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-46663-2 · Cited by 68
Rondung, E., Massoudi, P., Nieminen, K., Wickberg, B., Peira, N., Silverstein, R. A., Moberg, K., Lundqvist, M., Grundberg, Å., & Hultcrantz, M. (2023) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.14734 · Cited by 70
Balasubramanian, P., Abia‐Trujillo, D., Barrios-Ruiz, A., Garza-Salas, A., Koratala, A., Chandra, N. C., Lee‐Mateus, A. Y., Gonzalo Labarca, T., & Fernández-Bussy, S. (2024) · European Respiratory Review · doi:10.1183/16000617.0046-2024 · Cited by 72
“The quality of the data of single-arm studies was assessed with the QUADAS-2 tool and the same for comparative studies was assessed with the QUADAS-C tool, modified for our study as mentioned in supplementary appendix 2 [13, 14].”
MethodPillay, K., Keddie, S., Fitchett, E. J. A., Akinde, C., Baerenbold, O., Bradley, J., Falconer, J., Keogh, R. H., Lim, Z. N., Maldonado, B. N., et al. (2025) · The Lancet Microbe · doi:10.1016/j.lanmic.2025.101088 · Cited by 68
Huang, Y., Chen, J., Yan, W., Zang, D., Qin, Q., & Deng, A. (2015) · Tumor Biology · doi:10.1007/s13277-015-3352-z · Cited by 64
“For each domain in QUADAS-2, the risk of bias was assessed based on the answers to the signaling questions provided.”
InfluentialPardo, C. C., Cruz, I., Espejo-Martínez, B., Martos-Aparicio, C., López-Alcalde, S., & Olazarán, J. (2013) · International Journal of Alzheimer s Disease · doi:10.1155/2013/285462 · Cited by 64
Chemotherapy-Induced Peripheral Neuropathy Assessment Tools: A Systematic Review
Haryani, H., Fetzer, S. J., Wu, C.-L., & Hsu, Y.-Y. A. (2017) · Oncology nursing forum · doi:10.1188/17.onf.e111-e123 · Cited by 65
Verhagen, A. P., Downie, A., Maher, C. G., & Koes, B. W. (2017) · Pain · doi:10.1097/j.pain.0000000000000998 · Cited by 69
Pauta, M., Grande, M., Rodríguez‐Revenga, L., Kolomietz, E., & BORRELL, A. (2018) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.18929 · Cited by 69
Li, Q., Hu, M., Chen, Z., Li, C., Zhang, X., Song, Y., & Xiang, F. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.01.022 · Cited by 61
“Quality Assessment All included studies were assessed for methodological quality by two authors 7 independently using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool (Whiting 2011).”
Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis
Yu, Z., Mao, T., Xu, Y., Li, T., Wang, Y., Gao, F., & Sun, W. (2018) · Skeletal Radiology · doi:10.1007/s00256-018-2948-y · Cited by 61
Meta-Analysis of Adiponectin as a Biomarker for the Detection of Metabolic Syndrome
Liu, Z., Liang, S., Que, S., Zhou, L., Zheng, S., & Mardinoğlu, A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01238 · Cited by 64
TIMP-1 is a novel serum biomarker for the diagnosis of colorectal cancer: A meta-analysis
Meng, C., Yin, X.-W., Liu, J., Tang, K., Tang, H., & Liao, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207039 · Cited by 61
Pelander, L., Häggström, J. U., Larsson, A. O., Syme, H. M., Elliott, J., Heiene, R., & Ljungvall, I. (2019) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15445 · Cited by 80
Xiao, M., Yan, B.-C., Li, Y., Lu, J., & Qiang, J. (2019) · European Radiology · doi:10.1007/s00330-019-06461-9 · Cited by 63
QUADAS-3: A Revised Tool for the Quality Assessment of Diagnostic Test Accuracy Studies
Whiting, P. F., Tomlinson, E., Rutjes, A. W. S., Davenport, C. F., Yang, B., Westwood, M. E., Takwoingi, Y., Reitsma, J. B., Hyde, C., Bossuyt, P. M. M., et al. (2026) · Annals of Internal Medicine · doi:10.7326/annals-25-02104 · Cited by 60
Self-citationRepplinger, M. D., Levy, J. F., Peethumnongsin, E., Gussick, M., Svenson, J. E., Golden, S., Ehlenbach, W. J., Westergaard, R. P., Reeder, S. B., & Vanness, D. J. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25115 · Cited by 73
Nieuwenhuis, L. L., Hermans, F. J. R., de Vaate, A. J. M. B., Leeflang, M., Brölmann, H. A. M., Hehenkamp, W. J. K., Mol, B. W., Clark, T. J., & Huirne, J. A. F. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011126.pub2 · Cited by 67
Self-citationTang, C. X., Wang, Y. N., Zhou, F., Schoepf, U. J., van Assen, M., Stroud, R. E., Li, J. H., Zhang, X. L., Lu, M. J., Zhou, C. S., et al. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.04.011 · Cited by 60
Current status and quality of radiomics studies in lymphoma: a systematic review
Wang, H., Zhou, Y., Li, L., Hou, W., Ma, X., & Tian, R. (2020) · European Radiology · doi:10.1007/s00330-020-06927-1 · Cited by 61
2020 American Heart Association and American Red Cross Focused Update for First Aid
Pellegrino, J. L., Charlton, N. P., Carlson, J. N., Flores, G. E., Goolsby, C. A., Hoover, A. V., Kule, A., Magid, D. J., Orkin, A. M., Singletary, E. M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000900 · Cited by 70
Garcia, M. T., Mota, B. S., Cardoso, N., Martimbianco, A. L. C., Ricci, M. D., Carvalho, F. M., Gonçalves, R., Soares, J. M., & Filassi, J. R. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248768 · Cited by 61
Diagnostic accuracy of virtual cognitive assessment and testing: Systematic review and meta‐analysis
Watt, J. A., Lane, N. E., Veroniki, A. A., Vyas, M. V., Williams, C., Ramkissoon, N., Thompson, Y. Y., Tricco, A. C., Straus, S. E., & Goodarzi, Z. (2021) · Journal of the American Geriatrics Society · doi:10.1111/jgs.17190 · Cited by 60
Hanson, K. E., Altayar, O., Caliendo, A. M., Arias, C. A., Englund, J. A., Hayden, M. K., Lee, M. J., Loeb, M., Patel, R., El Alayli, A., et al. (2024) · Clinical Infectious Diseases · doi:10.1093/cid/ciab557 · Cited by 55
Travaglino, A., Raffone, A., Raimondo, D., Reppuccia, S., Ruggiero, A., Arena, A., Casadio, P., Zullo, F., Insabato, L., Seracchioli, R., et al. (2022) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-021-06385-0 · Cited by 68
The Paris System for Reporting Urinary Cytology: A Meta-Analysis
Nikas, I. P., Seide, S., Proctor, T., Kleinaki, Z., Kleinaki, M., & REYNOLDS, J. P. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12020170 · Cited by 68
Catlett, B., Hajarizadeh, B., Cunningham, E. B., Wolfson‐Stofko, B., Wheeler, A., Khandaker-Hussain, B., Feld, J. J., Martró, E., Chevaliez, S., Pawlotsky, J., et al. (2022) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiac049 · Cited by 60
Sharma, H., Sharma, S., Krishnan, A., Yuan, D., Vangaveti, V. N., Malabu, U. H., & Haleagrahara, N. (2022) · PLOS ONE · doi:10.1371/journal.pone.0267412 · Cited by 53
Li, Y., Liu, Y., Liang, Y., Wei, R., Zhang, W., Wang, Y., Luo, S., Pang, X., Wang, Y., Jiang, X., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08828-x · Cited by 62
Shafian, A. K., Mohamed, S., Raduan, N. J. N., & Yee, A. H. A. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e09441 · Cited by 67
Parvan, R., Hosseinpour, M., Moradi, Y., Devaux, Y., Cataliotti, A., & da Silva, G. J. J. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2700 · Cited by 62
Bona, D., Danelli, P., Sozzi, A., Sanzi, M., Cayre, L., Lombardo, F., Bonitta, G., Cavalli, M., Campanelli, G., & Aiolfi, A. (2022) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-022-05473-z · Cited by 67
Zhao, G., Xueju, W., & Ji, B. (2022) · American Journal of Roentgenology · doi:10.2214/ajr.22.28402 · Cited by 61
MetaBayesDTA: codeless Bayesian meta-analysis of test accuracy, with or without a gold standard
Cerullo, E., Sutton, A. J., Jones, H. E., Wu, O., Quinn, T., & Cooper, N. J. (2023) · BMC Medical Research Methodology · doi:10.1186/s12874-023-01910-y · Cited by 60
Kyriazidis, I. P., Jakob, D. A., Vargas, J. A. H., Franco, O. H., Degiannis, E., Dorn, P., Pouwels, S., Patel, B. P., Johnson, I., Houdlen, C. J., et al. (2023) · World Journal of Emergency Surgery · doi:10.1186/s13017-023-00504-9 · Cited by 60
Patel, K., Asrani, S. K., Fiel, M. I., Levine, D., Leung, D. H., Duarte‐Rojo, A., Dranoff, J. A., Nayfeh, T., Hasan, B., Taddei, T. H., et al. (2024) · Hepatology · doi:10.1097/hep.0000000000000842 · Cited by 68
“[23] Grading the quality of evidence We used the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) approach to rate certainty in the estimates.”
Exploring the efficacy and potential of large language models for depression: A systematic review
Omar, M., & Levkovich, I. (2024) · Journal of Affective Disorders · doi:10.1016/j.jad.2024.11.052 · Cited by 68
Rahimi‐Movaghar, V., Yousefifard, M., Ghelichkhani, P., Baikpour, M., Tafakhori, A., Asady, H., Faridaalaee, G., Hosseini, M., & Safari, S. (2016) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v4i3.234 · Cited by 71
Liu, Y., Zhao, Y., Yu, A., Zhao, B., Gao, Y., & Niu, H. (2015) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-015-3671-8 · Cited by 66
Westwood, M. E., Raatz, H., Misso, K., Burgers, L., Redekop, K., Lhachimi, S. K., Armstrong, N., & Kleijnen, J. (2013) · Radiology · doi:10.1148/radiol.13121136 · Cited by 60
Self-citationPrevalence of Fabry Disease in Stroke Patients—A Systematic Review and Meta-analysis
Shi, Q., Chen, J., Pongmoragot, J., Lanthier, S., & Saposnik, G. (2013) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2013.08.010 · Cited by 60
Hawkins, N. M., Virani, S., Sperrin, M., Buchan, I. E., McMurray, J. J. V., & Krahn, A. D. (2015) · European Journal of Heart Failure · doi:10.1002/ejhf.458 · Cited by 65
Molecular assays for the diagnosis of sepsis in neonates
Pammi, M., Flores, A., Versalovic, J. A., & Leeflang, M. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011926.pub2 · Cited by 66
Self-citationLee, J.-H., Lee, Y. K., Oh, S. H., Ahn, J., Lee, Y. E., Pyo, J., Choi, Y. Y., Kim, D., Bae, S., Sung, Y.-K., et al. (2016) · Osteoporosis International · doi:10.1007/s00198-015-3436-z · Cited by 60
Haroon, S. M., Jordan, R. E., O’Beirne-Elliman, J., & Adab, P. (2015) · npj Primary Care Respiratory Medicine · doi:10.1038/npjpcrm.2015.56 · Cited by 54
Rivero-Santana, A., Ferreira, D., Perestelo-Pérez, L., Westman, E., Wahlund, L.-O., Sarría, A., & Serrano-Aguilar, P. (2016) · Journal of Alzheimer's Disease · doi:10.3233/jad-160366 · Cited by 56
“Methodological quality of the included studies was independently assessed by two researchers (AR, DF) with the QUADAS-2 scale [34].”
Sun, C., Han, X., Li, X., Zhang, Y., & Du, X. (2017) · Otolaryngology · doi:10.1177/0194599816685701 · Cited by 60
Taylor‐Phillips, S., Geppert, J., Stinton, C., Freeman, K., Johnson, S., Fraser, H., Sutcliffe, P., & Clarke, A. (2017) · Research Synthesis Methods · doi:10.1002/jrsm.1255 · Cited by 58
Tyraskis, A., Bakalis, S., David, A. L., Eaton, S. D., & Coppi, P. D. (2017) · Prenatal Diagnosis · doi:10.1002/pd.5143 · Cited by 60
Yu, K., Yu, C., & Fang, Y. (2017) · International Journal of Rheumatic Diseases · doi:10.1111/1756-185x.13143 · Cited by 65
Juneau, D., Golfam, M., Hazra, S., Erthal, F., Zuckier, L. S., Bernick, J., Wells, G. A., Beanlands, R. S., & Chow, B. J. W. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.10.116 · Cited by 67
Delgado, A. F., Luca, F. D., van Westen, D., & Delgado, A. F. (2018) · Neuro-Oncology · doi:10.1093/neuonc/noy095 · Cited by 60
Malavolta, E. A., Assunção, J. H., Gracitelli, M. E. C., Yen, T. K., Rodrigues, M. B., & Neto, A. A. F. (2018) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-018-3095-6 · Cited by 60
Tan, N., Bavadian, N., Calais, J., Oyoyo, U. E., Kim, J., Türkbey, B., Mena, E., & Davenport, M. S. (2019) · The Journal of Urology · doi:10.1097/ju.0000000000000198 · Cited by 60
Ebell, M. H., McKay, B., Dale, A. P., Guilbault, R., & Ermias, Y. (2019) · The Annals of Family Medicine · doi:10.1370/afm.2354 · Cited by 67
Lalande, É., Burwash-Brennan, T., Burns, K. M., Harris, T., Thomas, S. H., Woo, M. Y., & Atkinson, P. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.08.027 · Cited by 61
Exhaled volatile organic compounds in adult asthma: a systematic review
Azim, A., Barber, C., Dennison, P., Riley, J., & Howarth, P. H. (2019) · European Respiratory Journal · doi:10.1183/13993003.00056-2019 · Cited by 66
Nuclear expression of β‐catenin in endometrial hyperplasia as marker of premalignancy
Travaglino, A., Raffone, A., Saccone, G., Mascolo, M., D’Alessandro, P., Arduino, B., Mollo, A., Insabato, L., & Zullo, F. (2019) · Apmis · doi:10.1111/apm.12988 · Cited by 63
Jubber, I., Shariat, S. F., Conroy, S., Tan, W. S., Gordon, P. C., Lotan, Y., Messing, E. M., Stenzl, A., van Rhijn, B., Kelly, J. D., et al. (2019) · European Urology · doi:10.1016/j.eururo.2019.10.010 · Cited by 68
Omar, M., Brin, D., Glicksberg, B., & Klang, E. (2024) · American Journal of Infection Control · doi:10.1016/j.ajic.2024.03.016 · Cited by 59
Guo, R., Cai, L., Fan, Y., Jin, J., Zhou, L., & Zhang, K. (2015) · Prostate Cancer and Prostatic Diseases · doi:10.1038/pcan.2015.20 · Cited by 62
TCGA molecular subgroups and FIGO grade in endometrial endometrioid carcinoma
Travaglino, A., Raffone, A., Mollo, A., Borrelli, G., Alfano, P., Zannoni, G. F., Insabato, L., & Zullo, F. (2020) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-020-05531-4 · Cited by 59
ten Hove, D., Treglia, G., Slart, R. H. J. A., Damman, K., Wouthuyzen‐Bakker, M., Postma, D. F., Gheysens, O. S., Borra, R., Mecozzi, G., van Geel, P. P., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04930-8 · Cited by 62
Murray, E. L., Iuzzini-Seigel, J., Maas, E., Terband, H., & Ballard, K. J. (2020) · American Journal of Speech-Language Pathology · doi:10.1044/2020_ajslp-20-00063 · Cited by 64
Depression Screening Tools for Patients with Kidney Failure: A Systematic Review
Kondo, K. K., Antick, J. R., Ayers, C. K., Kansagara, D. L., & Chopra, P. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05540420 · Cited by 62
Judah, H., Gil, M. M., Syngelaki, A., Galeva, S., Jani, J. C., Akolekar, R., & Nicolaides, K. H. (2021) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.23648 · Cited by 63
Can gray values be converted to Hounsfield units? A systematic review
Eguren, M., Holguin, A., Diaz, K. T., Vidalón, J. A., Liñán-Durán, C., Pachêco‐Pereira, C., & Lagravère, M. O. (2021) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20210140 · Cited by 59
Gatti, M., Gallone, G., Poggi, V., Bruno, F., Serafini, A., Depaoli, A., FILIPPO, O. D., Conrotto, F., Darvizeh, F., Faletti, R., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08603-y · Cited by 65
Shaikh, K., Osio, V. A., Leeflang, M., & Shaikh, N. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009185.pub3 · Cited by 59
Self-citationMason, R. H., Minaker, S. A., Luna, G. M. L., Bapat, P., Farahvash, A., Garg, A., Bhambra, N., & Muni, R. H. (2022) · Eye · doi:10.1038/s41433-022-02127-x · Cited by 65
Lin, C., Su, I., Huang, S., Chen, P., Traynor, V., Chang, H., Liu, I.-H., Lai, Y.-S., Lee, H., Rolls, K., et al. (2023) · Ageing Research Reviews · doi:10.1016/j.arr.2023.102025 · Cited by 67
Herrera, D., Tonetti, M. S., Chapple, I., Kebschull, M., Papapanou, P. N., Sculean, A., Abusleme, L., Aimetti, M., Belibasakis, G. N., Blanco, J., et al. (2025) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.14152 · Cited by 66
“These include a checklist for reporting DAS (STARD, STAndards for Reporting Diagnostic accuracy studies) (Bossuyt et al. 2015), tools for assessing quality, including both risk of bias and concerns regarding applicability (QUADAS-2, QUAlity of Diagnostic Accuracy Studies) (Whiting et al. 2011) and its extension for co…”
InfluentialBrigo, F., Turri, G., & Tinazzi, M. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.11.004 · Cited by 64
Dysphagia Screening Measures for Use in Nursing Homes: A Systematic Review
Park, Y., Bang, H. L., Han, H., & Chang, H. (2015) · Journal of Korean Academy of Nursing · doi:10.4040/jkan.2015.45.1.1 · Cited by 68
Kim, H.-J., Lee, S. Y., Shin, Y. R., Park, C. S., & Kim, K. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149465 · Cited by 70
Performance of 18F-Fluoride PET or PET/CT for the Detection of Bone Metastases
Shen, C., Qiu, Z., Han, T., & Luo, Q. (2014) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000000592 · Cited by 59
Béchet, S., Hill, F., Gilheaney, Ó., & Walshe, M. (2016) · Dysphagia · doi:10.1007/s00455-016-9737-3 · Cited by 59
“The risk of bias was evaluated using the revised quality assessment of diagnostic accuracy studies-2 tool [19, 20].”
A tuberculosis biomarker database: the key to novel TB diagnostics
Yerlikaya, S., Broger, T., MacLean, E. L.-H., Pai, M., & Denkinger, C. M. (2017) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2017.01.025 · Cited by 59
Lok, M. J., Miyake, H., Hock, A., Daneman, A., Pierro, A., & Offringa, M. (2018) · Pediatric Surgery International · doi:10.1007/s00383-018-4259-8 · Cited by 63
Chan, J. Y. C., Kwong, J. S. W., Wong, A., Kwok, T. C. Y., & Tsoi, K. K. F. (2018) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2018.05.010 · Cited by 65
Na, M. K., Kim, W., Lim, T. H., Jang, B.-H., Cho, Y., Choi, K.-S., Shin, H., Ahn, C., Lee, J., & Kim, J. G. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2018.08.024 · Cited by 59
Battle, C. E., Hayward, S., Eggert, S., & Evans, P. A. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2017-207416 · Cited by 59
Toner, P., Boehnke, J. R., Andersen, P., & McCambridge, J. (2019) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2019.01.030 · Cited by 64
Bajraktari, G., Bytyçi, I., & Henein, M. Y. (2019) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12595 · Cited by 64
Lisotti, A., Frazzoni, L., Fuccio, L., Serrani, M., Cominardi, A., Bazzoli, F., & Fusaroli, P. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.01.034 · Cited by 61
Gerges, B., Li, W., Leonardi, M., Mol, B. W., & Condous, G. S. (2021) · Human Reproduction Open · doi:10.1093/hropen/hoab041 · Cited by 64
“Traffic-light plot summarizing the authors’ review of the QUADAS-2 risk of bias and applicability concerns.”
Wang, Q., Li, C., Zhang, J., Hu, X., Fan, Y., Ma, K., Sparrelid, E., & Brismar, T. B. (2021) · Cancers · doi:10.3390/cancers13225864 · Cited by 61
Jansen, S. M., de Bruin, D. M., Henegouwen, M. I. V. B., Strackee, S. D., Veelo, D. P., van Leeuwen, T. G. J. M., & Gisbertz, S. S. (2018) · Diseases of the Esophagus · doi:10.1093/dote/dox161 · Cited by 60
Raffone, A., Travaglino, A., Saccone, G., Campanino, M. R., Mollo, A., Placido, G. D., Insabato, L., & Zullo, F. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13513 · Cited by 72
Nielsen, T. R., & Jørgensen, K. (2020) · International Psychogeriatrics · doi:10.1017/s1041610220000344 · Cited by 63
Hemmy, L. S., Linskens, E. J., Silverman, P. C., Miller, M. A., Talley, K. M., Taylor, B. C., Ouellette, J. M., Greer, N. L., Wilt, T. J., Butler, M. E., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-3889 · Cited by 67
Mohamed, M. F. H., Al-Shokri, S. D., Yousaf, Z., Danjuma, M. I.-M., Parambil, J. V., Mohamed, S., Mubasher, M., Dauleh, M. M., Hasanain, B., AlKahlout, M. A., et al. (2020) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.20-0371 · Cited by 58
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.