QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 1,901–2,000 of 14,770
Tækker, M., Kristjánsdóttir, B., Graumann, O., Laursen, C. B., & Pietersen, P. I. (2021) · Clinical Imaging · doi:10.1016/j.clinimag.2020.12.041 · Cited by 69
Thavarajasingam, S. G., El-Khatib, M. T., Rea, M. E., Russo, S., Lemcke, J., Al‐Nusair, L., & Vajkoczy, P. (2021) · Acta Neurochirurgica · doi:10.1007/s00701-021-04922-z · Cited by 69
Liu, Y., Gao, Y., Liang, B., & Liang, Z. (2023) · The Aging Male · doi:10.1080/13685538.2023.2261540 · Cited by 75
Mazzone, E., Cannoletta, D., Quarta, L., Chen, D. C., Thomson, A., Barletta, F. M., Stabile, A., Moon, D. A., Eapen, R. S., Lawrentschuk, N., et al. (2025) · European Urology · doi:10.1016/j.eururo.2025.03.003 · Cited by 82
Ziakas, P. D., Anagnostou, T., & Mylonakis, E. E. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182a66bb8 · Cited by 79
Ladabaum, U., Ford, J. M., Martel, M., & Barkun, A. N. (2015) · Gastroenterology · doi:10.1053/j.gastro.2015.07.037 · Cited by 72
Pupaibool, J., Vasoo, S. S., Erwin, P. J., Murad, M. H., & Berbari, E. F. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.07.003 · Cited by 69
Predictors of the Home-Clinic Blood Pressure Difference: A Systematic Review and Meta-Analysis
Sheppard, J. P., Fletcher, B., Gill, P. S., Martin, U., Roberts, N. W., & McManus, R. J. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv157 · Cited by 76
Li, D., He, Y.-C., Liu, J., & Chen, S. (2016) · Scientific Reports · doi:10.1038/srep20863 · Cited by 78
Jia, H., Huang, L., Zheng, Y., & Li, W. (2017) · Critical Care · doi:10.1186/s13054-017-1660-y · Cited by 70
Levis, B., Benedetti, A., Levis, A. W., Ioannidis, J. P. A., Shrier, I., Cuijpers, P., Gilbody, S., Kloda, L. A., McMillan, D., Patten, S. B., et al. (2017) · American Journal of Epidemiology · doi:10.1093/aje/kww191 · Cited by 64
Zacho, H. D., Nielsen, J. B., Haberkorn, U., Stenholt, L., & Petersen, L. J. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12480 · Cited by 69
“A well-defined reference test is critical for diagnostic test accuracy (Whiting et al., 2011).”
Sheikhbahaei, S., Jones, K. M., Werner, R. A., Fragomeni, R. A. S., Marcus, C. V., Higuchi, T., Rowe, S. P., Sólnes, L. B., & Javadi, M. S. (2019) · Annals of Nuclear Medicine · doi:10.1007/s12149-019-01343-y · Cited by 69
Radiolabelled choline versus PSMA PET/CT in prostate cancer restaging: a meta-analysis.
Treglia, G., Mestre, R. P., Ferrari, M. C., Bosetti, D. G., Pascale, M., Oikonomou, E., Dosso, S. D., Jermini, F., Prior, J. O., Roggero, E., et al. (2019) · PubMed · Cited by 83
Does This Patient Have Hip Osteoarthritis?
Metcalfe, D., Perry, D. C., Claireaux, H. A., Simel, D. L., Zogg, C. K., & Costa, M. L. (2019) · JAMA · doi:10.1001/jama.2019.19413 · Cited by 69
Salivary biomarkers for cancer diagnosis: a meta-analysis
Rapado‐González, Ó., Reglero, C. M., Salgado‐Barreira, Á., Takkouche, B., López‐López, R., Suárez‐Cunqueiro, M. M., & Muinelo‐Romay, L. (2020) · Annals of Medicine · doi:10.1080/07853890.2020.1730431 · Cited by 73
Arbyn, M., Xu, L., Verdoodt, F., Cuzick, J., Szarewski, A., Belinson, J. L., Wentzensen, N., Gage, J. C., & Khan, M. J. (2017) · Annals of Internal Medicine · doi:10.7326/m15-2735 · Cited by 68
Lauzier, F., Turgeon, A. F., Boutin, A., Shemilt, M., Côté, I., Lachance, O., Archambault, P. M., Lamontagne, F., Moore, L., Bernard, F., et al. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000046 · Cited by 68
Lynch, B. A., Kaufman, T. K., Rajjo, T. I., Mohammed, K., Kumar, S., Murad, M. H., Gentile, N. E., Koepp, G. A., McCrady-Spitzer, S. K., & Levine, J. A. (2019) · Journal of Primary Care & Community Health · doi:10.1177/2150132719874252 · Cited by 68
The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT
Pelgrim, G. J., Dorrius, M. D., Xie, X., den Dekker, M. A. M., Schoepf, U. J., Henzler, T., Oudkerk, M., & Vliegenthart, R. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.12.032 · Cited by 68
F18-FDG-PET for recurrent differentiated thyroid cancer: a systematic meta-analysis
Haslerud, T. M., Brauckhoff, K., Reisæter, L. A. R., Lein, T. E., Heinecke, A., Varhaug, J. E., & Biermann, M. (2015) · Acta Radiologica · doi:10.1177/0284185115594645 · Cited by 73
Dalton, B., Rajakumar, I., Langevin, A., Ondro, C., Sabuda, D. M., Griener, T. P., Dersch‐Mills, D., & Rennert‐May, E. (2019) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.10.029 · Cited by 73
Martucci, F., Pascale, M., Valli, M. C., Pesce, G. A., Froesch, P., Giovanella, L., Richetti, A., & Treglia, G. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2019.00336 · Cited by 73
Wen, L., Chen, J., Xu, H., Yu, Q., & Liu, K. (2020) · Diagnostics · doi:10.3390/diagnostics10090666 · Cited by 68
Detecting Delirium: A Systematic Review of Identification Instruments for Non‐ICU Settings
Helfand, B., D’Aquila, M., Tabloski, P. A., Erickson, K., Yue, J., Fong, T. G., Hshieh, T. T., Metzger, E. D., Schmitt, E. M., Boudreaux, E. D., et al. (2020) · Journal of the American Geriatrics Society · doi:10.1111/jgs.16879 · Cited by 77
Colli, A., Nadarević, T., Miletić, D., Giljača, V., Fraquelli, M., Štimac, D., & Casazza, G. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013346.pub2 · Cited by 89
Lee, S., Shim, S. R., Jeong, S. Y., & Kim, S. (2021) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2021.0915 · Cited by 79
Syer, T., Mehta, P. J., Antonelli, M., Mallett, S., Atkinson, D., Ourselin, S., & Punwani, S. (2021) · Cancers · doi:10.3390/cancers13133318 · Cited by 75
Self-citationLee, J. H., Song, J., & Shim, S. R. (2021) · Journal of Clinical Virology · doi:10.1016/j.jcv.2021.104985 · Cited by 78
“As recommended by the Cochrane Collaboration, we used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool to assess the risk of bias in diagnostic test accuracy [11].”
Endogenous Oxytocin Levels in Autism—A Meta-Analysis
Moerkerke, M., Peeters, M., de Vries, L. M., Daniëls, N., Steyaert, J. G., Alaerts, K., & Boets, B. (2021) · Brain Sciences · doi:10.3390/brainsci11111545 · Cited by 69
Zhou, X., Liu, J., Pan, J., Xu, Z., & Xu, J. (2022) · BMC Pulmonary Medicine · doi:10.1186/s12890-022-01914-2 · Cited by 75
Peltola, M. E., Leitinger, M., Halford, J. J., Vinayan, K. P., Kobayashi, K., Pressler, R., Mîndruță, I., Mayor, L. C., Lauronen, L., & Beniczky, S. (2023) · Epilepsia · doi:10.1111/epi.17448 · Cited by 73
Prill, R., Królikowska, A., de Girolamo, L., Becker, R., & Karlsson, J. (2023) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-023-07442-8 · Cited by 75
Hassan, C., Rizkala, T., Mori, Y., Spadaccini, M., Misawa, M., Antonelli, G., Rondonotti, E., Dekker, E., Houwen, B. B. S. L., Pech, O., et al. (2024) · The Lancet. Gastroenterology & hepatology · doi:10.1016/s2468-1253(24)00222-x · Cited by 81
Schreuder, S. M., Lensing, R. J., Stoker, J., & Bipat, S. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24784 · Cited by 68
Diagnostic accuracy of EEG changes during carotid endarterectomy in predicting perioperative strokes
Thirumala, P. D., Thiagarajan, K., Gedela, S., Crammond, D. J., & Balzer, J. R. (2015) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2015.08.014 · Cited by 70
Tamburrino, D., Rivière, D., Yaghoobi, M., Davidson, B. R., & Gurusamy, K. S. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011515.pub2 · Cited by 77
Diagnostic accuracy of CBCT for tooth fractures: A meta-analysis
Long, H., Zhou, Y., Ye, N., Liao, L., Jian, F., Wang, Y., & Lai, W. (2013) · Journal of Dentistry · doi:10.1016/j.jdent.2013.11.024 · Cited by 74
Liu, D., Xie, L., Zhao, H., Liu, X., & Cao, J. (2016) · BMC Infectious Diseases · doi:10.1186/s12879-016-1566-3 · Cited by 78
Youngstrom, E. A., Genzlinger, J. E., Egerton, G. A., & Meter, A. V. (2015) · Archives of Scientific Psychology · doi:10.1037/arc0000024 · Cited by 81
Utility of MRI for cervical spine clearance after blunt traumatic injury: a meta-analysis
Malhotra, A., Wu, X., Kalra, V. B., Nardini, H. K. G., Liu, R., Abbed, K. M., & Forman, H. P. (2016) · European Radiology · doi:10.1007/s00330-016-4426-z · Cited by 68
“The quality of each included study was assessed independently by two of the authors using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 form, in terms of risk of bias and applicability concerns [11].”
Discovery of biomarkers for endometrial cancer: current status and prospects
Rižner, T. L. (2016) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2016.1258302 · Cited by 73
Saied, A. M., Redant, C., El-Batouty, M., El-Lakkany, M. R., El-Adl, W., Anthonissen, J., Verdonk, R. C., & Audenaert, E. A. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1443-2 · Cited by 68
Bai, A. D., Agarwal, A., Steinberg, M., Showler, A., Burry, L. D., TOMLINSON, G. A., Bell, C. M., & Morris, A. M. (2017) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2017.04.025 · Cited by 71
Shapiro, A. J., Josephson, M. B., Rosenfeld, M., Yılmaz, Ö., Davis, S. D., Polineni, D., Guadagno, E., Leigh, M. W., & Lavergne, V. (2017) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201701-062sr · Cited by 69
Li, K., Du, J., Huang, L.-X., Ni, L., Liu, T., & Yang, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-08133-4 · Cited by 77
The utility of 18F-FDG and 68Ga-DOTA-Peptide PET/CT in the evaluation of primary pulmonary carcinoid
Jiang, Y., Hou, G., & Cheng, W. (2019) · Medicine · doi:10.1097/md.0000000000014769 · Cited by 68
Drain, P. K., Gardiner, J. L., Hannah, H. A., Broger, T., Dheda, K. U. J., Fielding, K., Walzl, G., Kaforou, M., Kranzer, K., Joosten, S. A., et al. (2019) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiz356 · Cited by 76
Blood Tests to Diagnose Fibrosis or Cirrhosis in Patients With Chronic Hepatitis C Virus Infection
Chou, R., & Wasson, N. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-5-201309030-00021 · Cited by 75
Abrahamyan, L., Sahakyan, Y., Chung, S., Pechlivanoglou, P., Bielecki, J., Carcone, S. M., Rac, V. E., Fitzpatrick, M., & Krahn, M. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1615-1 · Cited by 67
Trujillo, E. B., Kadakia, K. C., Thomson, C., Zhang, F. F., Livinski, A., Pollard, K., Mattox, T., Tucker, A., Williams, V., Walsh, D., et al. (2024) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.2688 · Cited by 89
Psarraki, E. E., Kokka, I., Bacopoulou, F., Chrousos, G. P., Artemiadis, A., & Darviri, C. (2021) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2020.105098 · Cited by 67
Sentinel node biopsy for diagnosis of lymph node involvement in endometrial cancer
Nagar, H., Wietek, N. C., Goodall, R. J., Hughes, W., Schmidt‐Hansen, M., & Morrison, J. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013021.pub2 · Cited by 90
Crocerossa, F., Marchioni, M., Novara, G., Carbonara, U., Ferro, M., Russo, G. I., Porpiglia, F., Nicola, M. D., Damiano, R., Riccardo Autorino, B., et al. (2020) · The Journal of Urology · doi:10.1097/ju.0000000000001369 · Cited by 67
Treatments for Acute Pain: A Systematic Review
Chou, R., Wagner, J., Ahmed, A. Y., Blazina, I., Brodt, E., Buckley, D., Cheney, T. P., Choo, E. K., Dana, T., Gordon, D. A., et al. (2020) · doi:10.23970/ahrqepccer240 · Cited by 90
Shapiro, A. E., Ross, J. M., Yao, M., Schiller, I., Kohli, M., Dendukuri, N., Steingart, K. R., & Horne, D. J. D. L. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013694.pub2 · Cited by 83
Bass, E. J., Pantović, A., Connor, M. J., Loeb, S., Rastinehad, A. R., Winkler, M. H., Gabe, R., & Ahmed, H. U. (2021) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-021-00449-7 · Cited by 67
The Current State and Validity of Digital Assessment Tools for Psychiatry: Systematic Review
Martin-Key, N. A., Spadaro, B., Funnell, E. L., Barker, E., Schei, T. S., Tomasik, J., & Bahn, S. (2021) · JMIR Mental Health · doi:10.2196/32824 · Cited by 71
Artificial intelligence for radiological paediatric fracture assessment: a systematic review
Shelmerdine, S. C., White, R., Liu, H., Arthurs, O. J., & Sebire, N. J. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01234-3 · Cited by 80
Liaghat, B., Pedersen, J. R., Husted, R. S., Pedersen, L. L., Thorborg, K., & Juhl, C. B. (2022) · British Journal of Sports Medicine · doi:10.1136/bjsports-2022-105674 · Cited by 84
Rizzo, S., Cozzi, A., Dolciami, M., Grande, F. D., Scarano, A. L., Papadia, A., Gui, B., Gandolfo, N. G., Catalano, C., & Manganaro, L. (2022) · Radiology · doi:10.1148/radiol.220795 · Cited by 69
THONG, L. T., CHOU, H. S., CHEW, H. S. J., & LAU, Y. (2023) · Lung Cancer · doi:10.1016/j.lungcan.2022.12.002 · Cited by 67
Capasso, L., Pacella, D., Migliaro, F., Salomè, S., Grasso, F., Corsini, I., Luca, D. D., Davis, P. G., & Raimondi, F. (2023) · Pediatric Pulmonology · doi:10.1002/ppul.26337 · Cited by 67
Ahmed, A., Aziz, S., Abd-Alrazaq, A. A., Farooq, F., Househ, M. S., & Sheikh, J. I. (2023) · Journal of Medical Internet Research · doi:10.2196/40259 · Cited by 76
“Two reviewers independently assessed the risk of bias of the included using an adapted version of the Quality Assessment of Diagnostic Accuracy Studies—Revised (QUADAS-2) tool [17].”
Garavand, A., Behmanesh, A., Aslani, N., Sadeghsalehi, H., & Ghaderzadeh, M. (2023) · International Journal of Intelligent Systems · doi:10.1155/2023/6442756 · Cited by 71
Alcázar, J. L., Orozco, R., Corral, T. M., Juez, L., Utrilla-Layna, J., Mínguez, J. Á., & Jurado, M. (2015) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.14905 · Cited by 67
Yang, X., Zeng, Z., Hou, Y., Yuan, T., Gao, C., Jia, W., Yi, X., & Liu, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0088745 · Cited by 66
Rowland, S. P., Dharmarajah, B., Moore, H. M., Lane, T. R. A., Cousins, J., Ahmed, A., & Davies, A. H. (2014) · Annals of Surgery · doi:10.1097/sla.0000000000000621 · Cited by 77
“This represented 10% of all morbidly obese patients undergoing open RYGB.”
InfluentialValidity and reliability of measurement of capillary refill time in children: a systematic review
Fleming, S., Gill, P. J., Jones, C., Taylor, J. A., den Bruel, A. V., Heneghan, C. J., & Thompson, M. (2014) · Archives of Disease in Childhood · doi:10.1136/archdischild-2014-307079 · Cited by 75
Special tests for assessing meniscal tears within the knee: a systematic review and meta-analysis
Smith, B. E., Thacker, D., Crewesmith, A., & Hall, M. C. (2015) · BMJ Evidence-Based Medicine · doi:10.1136/ebmed-2014-110160 · Cited by 75
A meta‐analysis of reflectance confocal microscopy for the diagnosis of malignant skin tumours
Xiong, Y., Ma, S., Li, X., Zhong, X., Duan, C., & Chen, Q. (2016) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.13712 · Cited by 67
Use of point-of-care ultrasound in long bone fractures: a systematic review and meta-analysis
Chartier, L. B., Bosco, L., Lapointe‐Shaw, L., & Chenkin, J. (2016) · Canadian Journal of Emergency Medicine · doi:10.1017/cem.2016.397 · Cited by 67
Chen, H.-H., Sun, F., Yeh, T., Liu, H., Huang, H., Kuo, B. I.-T., & Huang, H.-Y. (2017) · Family Practice · doi:10.1093/fampra/cmx098 · Cited by 69
Li, H., Deng, L., Bai, H. X., Sun, J., Cao, Y., Tao, Y., States, L. J., Farwell, M. D., Zhang, P. J., Xiao, B., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5472 · Cited by 73
Trigger Tool–Based Automated Adverse Event Detection in Electronic Health Records: Systematic Review
Musy, S. N., Ausserhofer, D., Schwendimann, R., Rothen, H. U., Jeitziner, M., Rutjes, A. W., & Simon, M. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9901 · Cited by 71
Self-citationde Klerk, C. M., Vendrig, L. M., Bossuyt, P. M., & Dekker, E. (2018) · The American Journal of Gastroenterology · doi:10.1038/s41395-018-0212-7 · Cited by 69
Self-citationGottlieb, M. A., Holladay, D., & Peksa, G. D. (2019) · Academic Emergency Medicine · doi:10.1111/acem.13682 · Cited by 73
Surov, A., & Wienke, A. (2020) · Clinical Nutrition · doi:10.1016/j.clnu.2020.07.023 · Cited by 73
He, L., Ip, D., Tam, G., Lui, V. C. H., Tam, P. K. H., & Chung, B. (2021) · Scientific Reports · doi:10.1038/s41598-021-91072-y · Cited by 77
Imaging modalities to inform the detection and diagnosis of early caries
Walsh, T., Macey, R., Riley, P., Glenny, A., Schwendicke, F., Worthington, H. V., Clarkson, J., Ricketts, D., Su, T., & Sengupta, A. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014545 · Cited by 89
The MRI features of placental adhesion disorder and their diagnostic significance: systematic review
Rahaim, N. S. A., & Whitby, E. H. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.04.010 · Cited by 66
Toddler Screening for Autism Spectrum Disorder: A Meta-Analysis of Diagnostic Accuracy
Sánchez-García, A. B., Galindo-Villardón, P., Nieto-Librero, A. B., Martín-Rodero, H., & Robins, D. L. (2019) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-018-03865-2 · Cited by 66
Chemical shift imaging for evaluation of adrenal masses: a systematic review and meta-analysis
Platzek, I., Sieron, D., Plodeck, V., Borkowetz, A., Laniado, M., & Hoffmann, R.-T. (2019) · European Radiology · doi:10.1007/s00330-018-5626-5 · Cited by 66
Zhang, S., Smailagic, N., Hyde, C., Noel-Storr, A. H., Takwoingi, Y., McShane, R., & Feng, J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010386.pub2 · Cited by 66
Temperature measurements with a temporal scanner: systematic review and meta-analysis
Geijer, H., Udumyan, R., Lohse, G., & Nilsagård, Y. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009509 · Cited by 66
Biomarkers for diagnosis of childhood tuberculosis: A systematic review
Togun, T. O., MacLean, E. L.-H., Kampmann, B., & Pai, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204029 · Cited by 69
Endometrial hyperplasia and the risk of coexistent cancer: WHO versus EIN criteria
Travaglino, A., Raffone, A., Saccone, G., Mollo, A., Placido, G. D., Insabato, L., & Zullo, F. (2018) · Histopathology · doi:10.1111/his.13776 · Cited by 73
Differential Diagnosis of Apraxia of Speech in Children and Adults: A Scoping Review
Allison, K. M., Cordella, C., Iuzzini-Seigel, J., & Green, J. R. (2020) · Journal of Speech Language and Hearing Research · doi:10.1044/2020_jslhr-20-00061 · Cited by 72
Diagnosing, managing and preventing anaphylaxis: Systematic review
de Silva, D., Singh, C., Muraro, A. M., Worm, M., Alviani, C., Cardona, V., DunnGalvin, A., Garvey, L. H., Riggioni, C., Angier, E., et al. (2020) · Allergy · doi:10.1111/all.14580 · Cited by 66
Caesar, R., Colditz, P. B., Cioni, G., & Boyd, R. N. (2020) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.14730 · Cited by 71
Xiang, L., Wu, S., Hua, Q., Bao, C., & Liu, H. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.606915 · Cited by 67
Winstanley, E. L., Mahoney, J. J., Castillo, F., & Comer, S. D. (2021) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2021.108838 · Cited by 72
Braito, I., Rudd, T., Büyüktaşkın, D., Ahmed, M., Glancy, C., & Mulligan, A. (2021) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-021-02688-y · Cited by 81
Williams, N. M., Rojas, K. D., Reynolds, J. M., Kwon, D., Tien, J. S., & Jaimes, N. (2021) · JAMA Dermatology · doi:10.1001/jamadermatol.2021.2845 · Cited by 73
Falster, C., Jacobsen, N., Coman, K. E., Højlund, M., Gaist, T. A., Posth, S., Møller, J. E., Brabrand, M., & Laursen, C. B. (2021) · Thorax · doi:10.1136/thoraxjnl-2021-216838 · Cited by 66
Anderson, A. W., Marinovich, M. L., Houssami, N., Lowry, K. P., Elmore, J. G., Buist, D. S. M., Hofvind, S. S. H., & Lee, C. I. (2022) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2021.11.008 · Cited by 74
Grobbee, E. J., Wisse, P. H. A., Schreuders, E. H., Roon, A., van Dam, L., Zauber, A. G., Lansdorp‐Vogelaar, I., Bramer, W. M., Berhane, S., Deeks, J. J., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009276.pub2 · Cited by 95
Self-citationVara, J., Manzour, N., Chacón, E., López-Picazo, A., Linares, M., Pascual, M. A., Guerriero, S., & Alcázar, J. L. (2022) · Cancers · doi:10.3390/cancers14133151 · Cited by 76
Diaphragm ultrasound to predict weaning outcome: systematic review and meta-analysis
Mahmoodpoor, A., Fouladi, S., Ramouz, A., Shadvar, K., Ostadi, Z., & Soleimanpour, H. (2022) · Anaesthesiology Intensive Therapy · doi:10.5114/ait.2022.117273 · Cited by 68
Shahriari, M. H., Sabbaghi, H., Asadi, F., Hosseini, A., & Khorrami, Z. (2022) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2022.08.004 · Cited by 71
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.