QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 2,301–2,400 of 14,770
Cho, J., Kim, J., Lee, J. S., Chee, C. G., Kim, Y., & Choi, S. I. (2020) · Head & Neck · doi:10.1002/hed.26377 · Cited by 58
Biomarkers for the Early Diagnosis of Sepsis in Burns
Li, A. T., Moussa, A., Gus, E. I., Paul, E. M., Yii, E., Romero, L., Lin, Z. C., Padiglione, A. A., Lo, C. H., Cleland, H. J., et al. (2021) · Annals of Surgery · doi:10.1097/sla.0000000000005198 · Cited by 58
Andrew, A., Navien, T. N., Yeoh, T. S., Citartan, M., Mangantig, E., Sum, M. S. H., Ch’ng, E. S., & Tang, T. (2022) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0010152 · Cited by 72
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to evaluate the quality and bias of each study [14].”
Ketogenic diet in pediatric seizures: a randomized controlled trial review and meta-analysis
Pizzo, F., Collotta, A. D., Nora, A. D., Costanza, G., Ruggieri, M., & Falsaperla, R. (2022) · Expert Review of Neurotherapeutics · doi:10.1080/14737175.2022.2030220 · Cited by 58
Asgari, M., Nazari, B., Bizzini, M., & Jaitner, T. (2022) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2022.05.001 · Cited by 72
Tan, J., Liu, Y., Ehnert, S., Nussler, A. K., Yu, Y., Xu, J.-Z., & Chen, T. (2022) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2022.875822 · Cited by 65
Meta-Analysis on the Validity of the Acoustic Voice Quality Index
Batthyany, C., Latoszek, B. B. V., & Maryn, Y. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.04.022 · Cited by 72
Martinez, A. P., Teklu, S., Tahir, P., & Garcia, M. E. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.36529 · Cited by 62
Pul, U., & Schwendicke, F. (2024) · Journal of Dentistry · doi:10.1016/j.jdent.2024.105104 · Cited by 64
Calvani, M., Arasi, S., Bianchi, A., Caimmi, D. P., Cuomo, B., Dondi, A., Indirli, G. C., Grutta, S. L., Panetta, V., & Verga, M. C. (2015) · Pediatric Allergy and Immunology · doi:10.1111/pai.12432 · Cited by 58
Abrigo, J., Fountain, D. M., Provenzale, J. M., Law, E. K. C., Kwong, J. S., Hart, M. G., & Tam, W. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011551.pub2 · Cited by 71
Pay, A. S. D., Wiik, J., Backe, B., Jacobsson, B., Strandell, A., & Klovning, A. (2015) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-015-0461-z · Cited by 58
D’Antonio, F., Khalil, A. A., Pagani, G. A., Papageorghiou, A. T., Bhide, A., & Thilaganathan, B. (2014) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13335 · Cited by 65
Evaluating Cough Assessment Tools
Schmit, K. M., Coeytaux, R. R., Goode, A. P., McCrory, D. C., Yancy, W. S., Kemper, A. R., Hasselblad, V., Heidenfelder, B. L., & Sanders, G. D. (2013) · CHEST Journal · doi:10.1378/chest.13-0310 · Cited by 57
Tang, S., Zhou, F., Sun, Y., Wei, L. S., Zhu, S., Yang, R., Huang, Y., & Yang, J. (2016) · Breast Cancer · doi:10.1007/s12282-016-0680-9 · Cited by 58
Liver fibrosis staging with diffusion-weighted imaging: a systematic review and meta-analysis
Jiang, H., Chen, J., Gao, R., Huang, Z., Wu, M., & Song, B. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0913-6 · Cited by 60
Simple tests for the diagnosis of childhood obesity: a systematic review and meta‐analysis
Simmonds, M. C., Llewellyn, A., Owen, C. G., & Woolacott, N. F. (2016) · Obesity Reviews · doi:10.1111/obr.12462 · Cited by 68
Alma, L. J., Bokslag, A., Maas, A. H. E. M., Franx, A., Paulus, W. J., & de Groot, C. J. M. (2017) · ESC Heart Failure · doi:10.1002/ehf2.12129 · Cited by 58
Elli, L., Casazza, G., Locatelli, M., Branchi, F., Ferretti, F., Conte, D., & Fraquelli, M. (2017) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.04.006 · Cited by 61
The diagnostic accuracy of urinary [TIMP-2]·[IGFBP7] for acute kidney injury in adults
Liu, C., Lu, X., Mao, Z., Kang, H., Liu, H., Pan, L., Hu, J., Wang, L., & Zhou, F. (2017) · Medicine · doi:10.1097/md.0000000000007484 · Cited by 58
Indocyanine Green Videoangiography in Aneurysm Surgery: Systematic Review and Meta-Analysis
Riva, M., Amin‐Hanjani, S., Giussani, C. G., Witte, O. D., & Bruneau, M. (2017) · Neurosurgery · doi:10.1093/neuros/nyx387 · Cited by 58
Cysouw, M. C. F., Kramer, G. M., Schoonmade, L. J., Boellaard, R., de Vet, H. C. W., & Hoekstra, O. S. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3775-4 · Cited by 58
IgM ELISA for leptospirosis diagnosis: a systematic review and meta-analysis
da Rosa, M. I., dos Reis, M. F., Simon, C. S., Dondossola, E. R., Alexandre, M. C. M., Colonetti, T., & Meller, F. D. O. (2017) · Ciência & Saúde Coletiva · doi:10.1590/1413-812320172212.14112016 · Cited by 68
Ji, C., Ni, Q., & Chen, W. (2018) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2017.12.023 · Cited by 62
Early differential diagnosis methods of biliary atresia: a meta-analysis
Wang, L., Yang, Y., Chen, Y., & Zhan, J. (2018) · Pediatric Surgery International · doi:10.1007/s00383-018-4229-1 · Cited by 58
Kotchoubey, B., & Pavlov, Y. G. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00315 · Cited by 59
Eriksson, H. K., Nordström, J., Gabrysch, K., Hailer, N. P., & Lazarinis, S. (2018) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999.0000000000000244 · Cited by 58
Fuzzy gold standards: Approaches to handling an imperfect reference standard
Walsh, T. (2018) · Journal of Dentistry · doi:10.1016/j.jdent.2018.04.022 · Cited by 55
Nguyen, A. V. P., Blears, E. E., Ross, E., Lall, R. R., & Ortega-Barnett, J. R. (2018) · Neurosurgical FOCUS · doi:10.3171/2018.8.focus18325 · Cited by 59
Benedetti, A., Wu, Y., Levis, B., Wilchesky, M., Boruff, J. T., Ioannidis, J. P. A., Patten, S. B., Cuijpers, P. J., Shrier, I., Gilbody, S. M., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-026598 · Cited by 66
Heuvelings, C. C., Bélard, S., Familusi, M. A., Spijker, R., Grobusch, M. P., & Zar, H. J. (2018) · British Medical Bulletin · doi:10.1093/bmb/ldy041 · Cited by 58
Rio‐Pertuz, G. D., Gutiérrez, J. F., Triana, A. J., Molinares, J. L., Robledo-Solano, A. B., Meza, J. L., Ariza-Bolívar, O. M., Acosta-Reyes, J. L., Garavito, A., Viasus, D., et al. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-4048-6 · Cited by 58
Meyer, H., Wienke, A., & Surov, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217781 · Cited by 65
Luchini, C., Veronese, N., Nottegar, A., Cappelletti, V., Daidone, M. G., Smith, L., Parris, C. N., Brosens, L. A. A., Caruso, M. G., Cheng, L., et al. (2019) · Cancers · doi:10.3390/cancers11081152 · Cited by 67
Treglia, G., Pascale, M., Lazzeri, E., van der Bruggen, W., Bolton, R. C. D., & Glaudemans, A. W. J. M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04571-6 · Cited by 61
Xu, L., Gao, J., Wang, Q., Yin, J., Yu, P., Bai, B., Pei, R., Chen, D., Yang, G., Wang, S., et al. (2019) · European Thyroid Journal · doi:10.1159/000504390 · Cited by 58
Thiele, M. S., Hugger, M. B., Kim, Y., Rautou, P., Elkrief, L., Jansen, C., Verlinden, W., Allegretti, G., Israelsen, M. E., Ştefănescu, H., et al. (2020) · Liver International · doi:10.1111/liv.14439 · Cited by 59
Giampietro, R. R., Cabral, M. V. G., Lima, S. A. M., Weber, S. A. T., & Nogueira, V. D. S. N. (2020) · Scientific Reports · doi:10.1038/s41598-020-64802-x · Cited by 60
Gu, Q., Li, C., Lai, J., Zhang, Z., Pan, J., Zhao, F., Yu, C., Li, Y., Chen, C., Chen, W., et al. (2020) · European Journal of Clinical Investigation · doi:10.1111/eci.13446 · Cited by 64
de Leijer, J. F., Metman, M. J. H., van der Hoorn, A., Brouwers, A. H., Kruijff, S., van Hemel, B. M., Links, T. P., & Westerlaan, H. E. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.723394 · Cited by 64
Shiva Shahiri, T., Richebé, P., Richard-Lalonde, M., & Gélinas, C. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00772-3 · Cited by 58
Jayakumar, T., & Benoy, J. J. (2022) · Journal of Voice · doi:10.1016/j.jvoice.2022.03.018 · Cited by 73
Thombs, B. D., Benedetti, A., Kloda, L. A., Levis, B., Riehm, K. E., Azar, M., Cuijpers, P., Gilbody, S., Ioannidis, J. P. A., McMillan, D., et al. (2015) · BMJ Open · doi:10.1136/bmjopen-2015-009742 · Cited by 57
Fink, H. A., Linskens, E. J., Silverman, P. C., McCarten, J. R., Hemmy, L. S., Ouellette, J. M., Greer, N. L., Wilt, T. J., & Butler, M. (2020) · Annals of Internal Medicine · doi:10.7326/m19-3888 · Cited by 57
Kobayashi, K., Nakao, H., Nishiyama, T., Lin, Y., Kikuchi, S., Kobayashi, Y., Yamamoto, T., Ishii, N., Ohashi, T., Satoh, K., et al. (2014) · European Radiology · doi:10.1007/s00330-014-3364-x · Cited by 57
Endoscopic ultrasound-guided parenchymal liver biopsy: a systematic review and meta-analysis
Baran, B., Kale, S. R., Patil, P., Kannadath, B. S., Ramireddy, S., Badillo, R., DaVee, R. T., & Thosani, N. C. (2020) · Surgical Endoscopy · doi:10.1007/s00464-020-08053-x · Cited by 58
Lung ultrasound vs chest radiography in the diagnosis of children pneumonia: Systematic evidence
Yan, J., Yu, N. H., Wang, Y.-H., Gao, Y., & Pan, L. (2020) · Medicine · doi:10.1097/md.0000000000023671 · Cited by 66
Hibbert, J., Halec, G., Baaken, D., Waterboer, T., & Brenner, N. (2021) · Cancers · doi:10.3390/cancers13123010 · Cited by 60
Netterström-Wedin, F., Matthews, M., & Bleakley, C. (2021) · Sports Health A Multidisciplinary Approach · doi:10.1177/19417381211029953 · Cited by 58
Ismaiel, A., Jaaouani, A., Leucuta, D., Popa, S., & Dumitrascu, D. L. (2021) · Biomedicines · doi:10.3390/biomedicines9121890 · Cited by 59
Gill, S. K., Bunting, K. V., Sartini, C., Cardoso, V. R., Ghoreishi, N., Uh, H., Williams, J. A., Suzart‐Woischnik, K., Banerjee, A., Asselbergs, F. W., et al. (2022) · Heart · doi:10.1136/heartjnl-2021-320417 · Cited by 62
Guidance to best tools and practices for systematic reviews
Kolaski, K., Logan, L. R., & Ioannidis, J. P. A. (2023) · JBI Evidence Synthesis · doi:10.11124/jbies-23-00139 · Cited by 63
Dajti, E., Frazzoni, L., Iascone, V., Secco, M., Vestito, A., Fuccio, L., Eusebi, L. H., Fusaroli, P., Rizzello, F., Calabrese, C., et al. (2023) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.17754 · Cited by 64
Zhu, J., Wu, L., Wang, Y., Fang, M., Liu, Q., & Zhang, X. (2024) · PLoS ONE · doi:10.1371/journal.pone.0302046 · Cited by 57
Demis, A., Joham, A. E., Teede, H. J., Mousa, A., Earnest, A., Hawley, J. M., Smith, L., Azziz, R., Arlt, W., & Tay, C. T. (2024) · Human Reproduction Update · doi:10.1093/humupd/dmae028 · Cited by 65
Kopka, M., von Kalckreuth, N., & Feufel, M. A. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01566-6 · Cited by 70
Aktürk, Z., Hapfelmeier, A., Fomenko, A., Dümmler, D., Eck, S., Olm, M., Gehrmann, J., von Schrottenberg, V., Rehder, R., Dawson, S., et al. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015455 · Cited by 100
Cohen, J. F., Cohen, R., Lévy, C., Thollot, F., Benani, M., Bidet, P., & Chalumeau, M. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.140772 · Cited by 62
Hoogedoorn, L., Peppelman, M., van de Kerkhof, P. C. M., van Erp, P. E. J., & Gerritsen, M. (2014) · British Journal of Dermatology · doi:10.1111/bjd.13499 · Cited by 57
Leo, G. D., Fisci, E., Secchi, F., Alì, M., Ambrogi, F., Sconfienza, L. M., & Sardanelli, F. (2015) · European Radiology · doi:10.1007/s00330-015-4134-0 · Cited by 57
Roseman, M., Kloda, L. A., Saadat, N., Riehm, K. E., Ickowicz, A., Baltzer, F., Katz, L. Y., Patten, S. B., Rousseau, C., & Thombs, B. D. (2016) · The Canadian Journal of Psychiatry · doi:10.1177/0706743716651833 · Cited by 65
Choi, M., Lim, S., Choi, M., Shim, K., & Lee, S. H. (2016) · Gut and Liver · doi:10.5009/gnl16015 · Cited by 57
“A quality appraisal tool: Quality Assessment of Diagnostic Accuracy Studies-II Determination of study design quality was performed using the Quality Assessment of Diagnostic Accuracy Studies-II (QUADAS-II) tool.(9) QUADAS-II is a quality appraisal tool used in diagnostic studies.”
Sivakumar, H., & Peyton, P. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew170 · Cited by 65
Moretti, F., D’Antona, P., Finardi, E., Barbetta, M., Dominioni, L., Poli, A., Gini, E., Noonan, D. M., Imperatori, A. S., Rotolo, N., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.21739 · Cited by 61
The diagnostic values of UCH-L1 in traumatic brain injury: A meta-analysis
Shahjouei, S., Sadeghi-Naini, M., Yang, Z., Kobeissy, F. H., Rathore, D. S., Shokraneh, F., Blackburn, S., Manley, G. A., & Wang, K. (2017) · Brain Injury · doi:10.1080/02699052.2017.1382717 · Cited by 62
Telesonography in emergency medicine: A systematic review
Marsh-Feiley, G., Eadie, L., & Wilson, P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0194840 · Cited by 54
Mouthaan, B. E., Rados, M., Boon, P., Carrette, E., Diehl, B., Jung, J., Kimiskidis, V. Κ., Kobulashvili, T., Kuchukhidze, G., Larsson, P. G., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.12.016 · Cited by 58
Lee, Y., McKechnie, T., Doumouras, A. G., Handler, C., Eskicioglu, C., Gmora, S. B., Anvari, M., & Hong, D. (2019) · Obesity Surgery · doi:10.1007/s11695-019-03832-5 · Cited by 57
Cheung, C. C., Barnes, P. J., Bigras, G., Boerner, S. L., BUTANY, J. W., Calabrese, F., Couture, C., Deschênes, J., El-Zimaity, H. M. T., Fischer, G., et al. (2019) · Applied immunohistochemistry & molecular morphology · doi:10.1097/pai.0000000000000800 · Cited by 58
Reis, R. D. C., Almeida, K. J., Lopes, L. D. S., Mendes, C. M. D. M., & Bor‐Seng‐Shu, E. (2019) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.106635 · Cited by 62
Ebner, L., Christodoulidis, S., Stathopoulou, T., Geiser, T., Stalder, O., Limacher, A., Heverhagen, J. T., Mougiakakou, S. G., & Christe, A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0226084 · Cited by 62
McGrath, T. A., Frank, R. A., Schieda, N., Blew, B., Salameh, J., Bossuyt, P. M., & McInnes, M. D. F. (2020) · European Radiology · doi:10.1007/s00330-019-06559-0 · Cited by 67
“Concerns regarding applicability were also assessed using the QUADAS-2 tool [16].”
Self-citationLan, L., Luo, Y., Zhou, M., Huo, L., Chen, H., Zuo, Q., & Deng, W. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00044 · Cited by 57
Carotid Ultrasound to Predict Fluid Responsiveness: A Systematic Review
Beier, L., Davis, J. J., Esener, D. E., Grant, C. D., & Fields, J. M. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15301 · Cited by 61
“Quality Assessment/Risk of Bias The quality of included studies was assessed by Quality Assessment of Diagnostic Accuracy Studies version 2.(17) Beier et al—Carotid Ultrasound to Predict Fluid Responsiveness”
Accuracy of Signs and Symptoms for the Diagnosis of Community‐acquired Pneumonia: A Meta‐analysis
Ebell, M. H., Chupp, H., Cai, X., Bentivegna, M., & Kearney, M. (2020) · Academic Emergency Medicine · doi:10.1111/acem.13965 · Cited by 58
Drukker, L., Bradburn, E., Rodriguez, G., Roberts, N. W., Impey, L. W. M., & Papageorghiou, A. T. (2020) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.16468 · Cited by 58
Ultrastaging methods of sentinel lymph nodes in endometrial cancer – a systematic review
Burg, L. C., Hengeveld, E. M., Hout, J. I. ’., Bulten, J., Bult, P., & Zusterzeel, P. L. M. (2020) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2020-001964 · Cited by 62
Goncalves, L. N., van den Hoven, P., van Schaik, J., Leeuwenburgh, L. C., Hendricks, C. H. F., Verduijn, P. S., van der Bogt, K. E. A., van Rijswijk, C. S. P., Schepers, A., Vahrmeijer, A. L., et al. (2021) · Life · doi:10.3390/life11050433 · Cited by 57
Subali, A. D., Wiyono, L., Yusuf, M. F. R. H., & Zaky, M. F. A. (2021) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2021.115589 · Cited by 59
Marino, F., Failla, C., Carrozza, C., Ciminata, M., Chilà, P., Minutoli, R., Genovese, S., Puglisi, A., Arnao, A. A., Tartarisco, G., et al. (2021) · Brain Sciences · doi:10.3390/brainsci11060727 · Cited by 56
Hassan, C., Misawa, M., Rizkala, T., Mori, Y., Sultan, S., Facciorusso, A., Antonelli, G., Spadaccini, M., Houwen, B. B. S. L., Rondonotti, E., et al. (2024) · Annals of Internal Medicine · doi:10.7326/m23-2865 · Cited by 56
Hosseini, M., Ghelichkhani, P., Baikpour, M., Tafakhori, A., Asady, H., Hajighanbari, M. J., Yousefifard, M., & Safari, S. (2015) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v3i4.285 · Cited by 64
Peters, M. J. M., Bastiaenen, C. H. G., Brans, B. T., Weijers, R. E., & Willems, P. C. P. H. (2019) · Skeletal Radiology · doi:10.1007/s00256-019-03181-5 · Cited by 56
Performance of EU-TIRADS in malignancy risk stratification of thyroid nodules: a meta-analysis
Castellana, M., Grani, G., Radziņa, M., Guerra, V., Giovanella, L., Deandrea, M., Ngu, R., Durante, C., & Trimboli, P. (2020) · European Journal of Endocrinology · doi:10.1530/eje-20-0204 · Cited by 58
“Risk of bias and concerns about applicability were rated as low, high or unclear (16).”
BackgroundFellmeth, G., Harrison, S., Opondo, C., Nair, M., Kurinczuk, J. J., & Alderdice, F. (2021) · BMC Psychiatry · doi:10.1186/s12888-021-03190-6 · Cited by 51
Evangelista, L., Zucchetta, P., Moletta, L., Serafini, S., Cassarino, G., Pegoraro, N., Bergamo, F., Sperti, C., & Cecchin, D. (2021) · Annals of Nuclear Medicine · doi:10.1007/s12149-021-01629-0 · Cited by 59
Reynolds, J. C., Nicholson, T., O’Neil, B. J., Drennan, I. R., Issa, M., & Welsford, M. (2022) · Resuscitation · doi:10.1016/j.resuscitation.2022.01.006 · Cited by 60
Karimi, L., Ahari, A. M., Jahangiry, L., Sadeghi‐Bazargani, H., & Farahbakhsh, M. (2022) · BMC Psychiatry · doi:10.1186/s12888-022-03730-8 · Cited by 61
Kim, T., Woo, S., Ebrahimzadeh, S., McInnes, M. D. F., Gerst, S. R., & Do, R. K. (2022) · American Journal of Roentgenology · doi:10.2214/ajr.22.27989 · Cited by 60
Sun, R., Ge, B., Wu, S., Li, H., & Lin, L. (2023) · Asian Journal of Psychiatry · doi:10.1016/j.ajp.2023.103691 · Cited by 59
Berhanu, D., Ferreira, J. C., Pinto, L. A., de Sousa, D. A., Neto, L. L., & Ferreira, J. (2023) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2023.120853 · Cited by 59
Impact of Preprocessing Parameters in Medical Imaging-Based Radiomic Studies: A Systematic Review
Trojani, V., Bassi, M. C., Verzellesi, L., & Bertolini, M. (2024) · Cancers · doi:10.3390/cancers16152668 · Cited by 66
Pandey, R., Brennan, N. F., Trachana, K., Katsandres, S. C., Bodamer, O. A., Belmont, J. W., Veenstra, D. L., & Peng, S. (2025) · Genetics in Medicine · doi:10.1016/j.gim.2025.101398 · Cited by 64
A systematic review of the role of C4d in the diagnosis of acute antibody-mediated rejection
Sapir‐Pichhadze, R., Curran, S. P., John, R., Tricco, A. C., Uleryk, E. M., Laupacis, A., Tinckam, K. J., Sis, B., Beyene, J., Logan, A. G., et al. (2014) · Kidney International · doi:10.1038/ki.2014.166 · Cited by 56
Xiong, Y., Ma, S., Zhou, J., Zhong, X.-S., & Chen, Q. (2015) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.13267 · Cited by 56
Manchikanti, L. (2013) · Pain Physician · doi:10.36076/ppj.2013/16/se97 · Cited by 63
Yang, G., Wang, Y., & Jiang, X. (2016) · The Indian Journal of Pediatrics · doi:10.1007/s12098-016-2144-9 · Cited by 59
Tatone, E. H., Gordon, J. L., Hubbs, J., LeBlanc, S. J., DeVries, T. J., & Duffield, T. F. (2016) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2016.06.002 · Cited by 68
Best, L. M., Webb, A., Gurusamy, K. S., Cheng, S. F., & Richards, T. (2016) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2016.05.019 · Cited by 56
A meta-analysis of arterial spin labelling perfusion values for the prediction of glioma grade
Kong, L., Chen, H., Yang, Y., & Chen, L. (2016) · Clinical Radiology · doi:10.1016/j.crad.2016.10.016 · Cited by 56
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.