QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 5,301–5,400 of 14,770
Serum or plasma ferritin concentration as an index of iron deficiency and overload
Garcia‐Casal, M. N., Pasricha, S., Martinez, R. X., Lopez-Perez, L., & Peña‐Rosas, J. P. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011817 · Cited by 28
D-dimer test for excluding the diagnosis of pulmonary embolism
Crawford, F., Andras, A., Welch, K., Sheares, K. K. K., Keeling, D. M., & Chappell, F. M. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010864 · Cited by 24
Michelet, D., Julien-Marsollier, F., Vacher, T., Bellon, M., Skhiri, A., Bruneau, B., Fournier, J., Diallo, T., Luce, V., Brasher, C., et al. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2018.09.027 · Cited by 22
Chng, C. L., Zheng, K., Kwee, A. K., Lee, M. H., Ting, D. S. W., Wong, C. P., Hu, G., Ooi, B. C., & Kheok, S. W. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1300196 · Cited by 24
“The QUADAS-2 tool is the most used instrument in the quality assessment of diagnostic accuracy studies (12) and its use is recommended by current PRISMA 2020 guidance (11).”
Kravchuk, A. P., Wolff, I., Gilfrich, C. P., Wirtz, R. M., Soares, P., Braun, K.-P., Brookman-May, S. D., Kollitsch, L., Hauner, K., Burchardt, M., et al. (2024) · Cancers · doi:10.3390/cancers16040753 · Cited by 22
Särkilahti, N., Hirvonen, M., Lavapuro, J., Takatalo, J., Löyttyniemi, E., & Tenovuo, O. S. (2024) · Scientific Reports · doi:10.1038/s41598-024-63545-3 · Cited by 26
“We choose QUADAS-2 because it is recommended for systematic reviews to assess the risk of bias and applicability of diagnostic accuracy studies 17 .”
Lachowicz, J. A., Smallwood, N., Prasad, J. D., Patel, P., Voutier, C. R., Khor, Y. H., & Steinfort, D. (2024) · European Respiratory Review · doi:10.1183/16000617.0035-2024 · Cited by 25
Tu, L., Deng, Y., Chen, Y., & Luo, Y. (2024) · BMC Medical Imaging · doi:10.1186/s12880-024-01403-4 · Cited by 25
“The QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies-2) was leveraged to discern the risk of bias and applicability of the included studies [23].”
MethodDeep learning in Cobb angle automated measurement on X-rays: a systematic review and meta-analysis
Zhu, Y., Yin, X., Chen, Z., Zhang, H., Xu, K., Zhang, J., & Wu, N. (2024) · Spine Deformity · doi:10.1007/s43390-024-00954-4 · Cited by 22
“Their evaluation was based on the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [15].”
Hemodynamic Impact of the Trendelenburg Position: A Systematic Review and Meta-analysis
Likhvantsev, V. V., Landoni, G., Бондоевич, Б. Л., Polyakov, P. A., Yadgarov, M. Y., Викторович, Р. П., Плотников, Г. П., KORNELYUK, R. A., Komkova, V. V., Zaraca, L., et al. (2024) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2024.10.001 · Cited by 22
Liao, Z., Luo, D., Tang, X., Huang, F., & Zhang, X. (2025) · Frontiers in Oncology · doi:10.3389/fonc.2025.1550838 · Cited by 26
“The quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, speci fi cally including patient selection, index test, reference standard, and fl ow and timing (11).”
Xu, H., Gong, T., Song, X., Chen, Q., Bao, Q., Yao, W., Xie, M.-M., Li, C., Grzegorzek, M., Shi, Y., et al. (2025) · Journal of Medical Internet Research · doi:10.2196/53567 · Cited by 26
Characteristics of scores used for quantitative lung ultrasound in neonates: a systematic review
Sartorius, V., Brunet, S. R., & Luca, D. D. (2025) · European Respiratory Review · doi:10.1183/16000617.0232-2024 · Cited by 22
“%) being validated. main neonatal respiratory disorders, but scores A [18] and B [19] were the only validated scores used in RDS, TTN, NARDS and BPD.”
InfluentialZhou, J., Yang, S., Liu, T., Sun, Y., & Li, S. (2025) · BMC Cancer · doi:10.1186/s12885-025-13809-6 · Cited by 25
“The quality assessment was conducted independently by two authors (J.Z. and S.Y.) adopting Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist for diagnostic accuracy studies [22] or using the Newcastle–Ottawa scale (NOS) for non-diagnostic studies [23].”
Nguyen, M. H., Minh, L. H. N., Bui, A. T., & Le, N. Q. K. (2025) · Lung Cancer · doi:10.1016/j.lungcan.2025.108577 · Cited by 24
Li, X., Bai, J., Zhou, X. J., Wang, T., Zhang, Y., & Hu, Y. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000002423 · Cited by 23
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [ 32 ] was used to evaluate the quality of the included studies.”
Geppert, J., Auguste, P., Asgharzadeh, A., Ghiasvand, H., Patel, M., Brown, A., Jayakody, S., Helm, E., Todkill, D., Madan, J., et al. (2025) · Health Technology Assessment · doi:10.3310/jytw8921 · Cited by 22
Zheng, Z., Lu, Z., Yan, F., & Song, Y. (2025) · PLoS ONE · doi:10.1371/journal.pone.0322720 · Cited by 24
“Quality Assessment: Studies assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool were included only if they had a rating of “high risk” in at most one domain of bias [17].”
Artificial intelligence in bronchoscopy: a systematic review
Cold, K. M., Vamadevan, A., Laursen, C. B., Bjerrum, F., Singh, S., & Konge, L. (2025) · European Respiratory Review · doi:10.1183/16000617.0274-2024 · Cited by 29
“Future reviews focusing on diagnostic accuracy for CADx in EBUS could apply more specific tools like Quality Assessment of Diagnostic Accuracy Studies (QUADAS) [68].”
Zhao, Y., Zhang, L., Zhang, S., Li, J., Shi, K., Yao, D., Li, Q., Zhang, T., Xu, L., Geng, L., et al. (2025) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-025-00997-2 · Cited by 28
“The quality of diagnostic accuracy studies was assessed using the QUADAS-2 tool developed by Whiting et al. at the University of York [17].”
Horne, D. J. D. L., Zifodya, J. S., Shapiro, A. E., Church, E. C., Kreniske, J. S., Kay, A. W., Scandrett, K., Steingart, K. R., & Takwoingi, Y. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009593.pub6 · Cited by 42
Sun, C., McEwan, A. L., Boulton, K., Demetriou, E. A., Sadozai, A. K., Lampit, A., & Guastella, A. J. (2025) · EBioMedicine · doi:10.1016/j.ebiom.2025.105931 · Cited by 22
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool 16 was used to assess the risk of bias and applicability.”
Bañares, J., Pons, M., Reiberger, T., Mandorfer, M., Jachs, M., Semmler, G., Colecchia, A., Colecchia, L., Dajti, E., Bureau, C., et al. (2025) · Journal of Hepatology · doi:10.1016/j.jhep.2025.10.014 · Cited by 27
Richardson, R., Trépel, D., Perry, A., Ali, S., Duffy, S., Gabe, R., Gilbody, S. M., Glanville, J., Hewitt, C. E., Manea, L., et al. (2015) · Health Technology Assessment · doi:10.3310/hta19010 · Cited by 42
Fujiwara, T., Miyata, T., Tokumasu, H., Gemba, H., & Fukuoka, T. (2016) · Acute Medicine & Surgery · doi:10.1002/ams2.256 · Cited by 22
Diagnostic accuracy of midkine on hepatocellular carcinoma: A meta-analysis
Zhang, B., Li, B., Kong, L., Yan, L., & Yang, J.-Y. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223514 · Cited by 22
Pereira, A. M. G., Brizon, V. S. C., Carvas, N., de Carvalho, M. D. S. R., Cuvero, E. M., Buehler, A. M., Pereira, T. D. V., & Lopes, R. G. C. (2019) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2019.07.016 · Cited by 23
Trigg, R. M., Turner, S. D., Shaw, J., & Jahangiri, L. (2020) · British Journal of Cancer · doi:10.1038/s41416-020-0740-y · Cited by 22
Sims, J. I., Chau, M. T., & Davies, J. (2020) · European Radiology · doi:10.1007/s00330-020-06804-x · Cited by 25
Yousif, A., Dault, R., Courteau, M., Blais, L., Cloutier, A., Lacasse, A., Vanasse, A., & on behalf of the TORSADE Cohort Working Group (2020) · Journal of Asthma · doi:10.1080/02770903.2020.1827425 · Cited by 22
Alternative clinical specimens for the detection of SARS‐CoV‐2: A rapid review
Comber, L., Walsh, K. A., Jordan, K., O’Brien, K. K., Clyne, B., Teljeur, C., Drummond, L., Carty, P. G., Gascun, C. F. D., Smith, S. M., et al. (2020) · Reviews in Medical Virology · doi:10.1002/rmv.2185 · Cited by 23
Zhang, Y., Chen, H., Zhou, X., Pan, W., Zhou, X., & Pan, H. (2020) · World Journal of Gastroenterology · doi:10.3748/wjg.v26.i40.6279 · Cited by 27
Craniofacial growth predictors for class II and III malocclusions: A systematic review
Jiménez‐Silva, A., Carnevali-Arellano, R., Vivanco-Coke, S., Tobar‐Reyes, J., Araya-Díaz, P., & Montenegro, H. P. (2020) · Clinical and Experimental Dental Research · doi:10.1002/cre2.357 · Cited by 22
Quimby, A. E., Lui, J. T., & Chen, J. (2020) · Otology & Neurotology · doi:10.1097/mao.0000000000003007 · Cited by 22
Diagnostic and Prognostic Significance of Dysregulated Expression of Circular RNAs in Osteosarcoma
Zhang, C., He, J., Qi, L., 段志西, Wang, W., Wang, W., Tu, C., & Li, Z. (2021) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2021.1874922 · Cited by 22
“Diagnostic Accuracy II (QUADAS II) checklist [31], while studies on prognosis were rated by the Newcastle-Ottawa Scale (NOS) as previously described [32,33].”
Wu, M., Ren, A., Xu, D., Peng, X., Ye, X., & Li, A. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.12.017 · Cited by 25
Milton, C. K., O’Neal, C. M., & Conner, A. K. (2021) · Journal of Neurology · doi:10.1007/s00415-020-10391-8 · Cited by 23
Muaddi, H., Silva, S., Choi, W. J., Coburn, N. G., Hallet, J. I., Law, C. H. L., Cheung, H., & Karanicolas, P. J. (2021) · Annals of Surgical Oncology · doi:10.1245/s10434-021-09824-z · Cited by 22
Doust, J. A., Bell, K., Leeflang, M., Dinnes, J., Lord, S. J., Mallett, S., van de Wijgert, J. H. H. M., Sandberg, S., Adeli, K., Deeks, J. J., et al. (2021) · BMJ · doi:10.1136/bmj.n568 · Cited by 24
Self-citationKhazdouz, M., Hasani, M., Mehranfar, S., Ejtahed, H., Djalalinia, S., Gorabi, A. M., Esmaeili‐Abdar, M., Saleh, S. K., Arzaghi, S. M., Zahedi, H., et al. (2021) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-021-00771-w · Cited by 25
Tenewitz, C., Le, R. T., Hernandez, M., Baig, S., & Meyer, T. E. (2021) · 3D Printing in Medicine · doi:10.1186/s41205-021-00102-y · Cited by 22
Pryce, J., & Reimer, L. J. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciab197 · Cited by 22
Prediction methods of maxillary canine impaction: a systematic review
Jiménez‐Silva, A., Carnevali-Arellano, R., Vivanco-Coke, S., Tobar‐Reyes, J., Araya-Díaz, P., & Montenegro, H. P. (2021) · Acta Odontologica Scandinavica · doi:10.1080/00016357.2021.1936163 · Cited by 22
Chowsilpa, S., Bamiou, D., & Koohi, N. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.656117 · Cited by 22
Yemm, H., Robinson, L. A., Paddick, S., Dotchin, C. L., Goodson, M. L., Narytnyk, A., Poole, M., & Ardle, R. M. (2021) · Journal of Alzheimer s Disease · doi:10.3233/jad-210532 · Cited by 23
Pang, K. H., Campi, R., Arlandis, S., Bø, K., Chapple, C. R., Costantini, E., Farag, F. F., Groen, J., Karavitakis, M., Lapitan, M. C., et al. (2021) · European Urology Focus · doi:10.1016/j.euf.2021.09.003 · Cited by 24
Lee, M. K., Choi, Y., & Jung, S. L. (2021) · Scientific Reports · doi:10.1038/s41598-021-98508-5 · Cited by 26
Deawjaroen, K., Sillabutra, J., Poolsup, N., Stewart, D. C., & Suksomboon, N. (2021) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.15104 · Cited by 26
Wang, Y., Wu, C., Bai, C., Lu, S., Yang, Y., Lin, Y., Lai, W.-Y., Lin, T.-W., Jheng, Y.-C., Lee, M., et al. (2021) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000626 · Cited by 27
Ling, S. W., de Jong, A. C., Schoots, I. G., Nasserinejad, K., Busstra, M. B., van der Veldt, A. A. M., & Brabander, T. (2021) · European Urology Open Science · doi:10.1016/j.euros.2021.09.006 · Cited by 22
Kalot, M. A., Husainat, N. M., Tayiem, S., Alayli, A. E., Dimassi, A. B., Diab, O. A., Abughanimeh, O. K. M., Madoukh, B., Qureini, A., Ameer, B., et al. (2021) · Blood Advances · doi:10.1182/bloodadvances.2021004368 · Cited by 22
Islam, M. M., Poly, T. N., Walther, B. A., Lin, M., & Li, Y. (2021) · Cancers · doi:10.3390/cancers13215253 · Cited by 23
Imaging of the medial collateral ligament of the knee: a systematic review
Meyer, P. T., Reiter, A., Akoto, R., Steadman, J. N., Pagenstert, G., Frosch, K., & Krause, M. (2021) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-021-04200-8 · Cited by 29
Liu, Y., Kan, Y., Zhang, J., Li, N., & Wang, Y. (2021) · Cancer Medicine · doi:10.1002/cam4.4365 · Cited by 22
Nielsen, J. M., Rades, D., & Kjær, T. W. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.2012152 · Cited by 24
Sisay, B. G., Hassen, H. Y., Jima, B. R., Atlantis, E. E., & Gebreyesus, S. H. (2022) · Public Health Nutrition · doi:10.1017/s1368980022000143 · Cited by 27
Verrier, W., Pittock, L. J., Bodoceanu, M., & Piper, K. (2022) · Radiography · doi:10.1016/j.radi.2021.12.010 · Cited by 22
Liu, J.-N., Lu, S., & Fu, C.-M. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-02989-7 · Cited by 22
Takahashi, T., Shin, D., Kuno, T., Lee, J. M., Latib, A., Fearon, W. F., Maehara, A., & Kobayashi, Y. (2022) · Journal of Cardiology · doi:10.1016/j.jjcc.2022.02.015 · Cited by 23
Bahar, R. C., Merkaj, S., Petersen, G. C., Tillmanns, N., Subramanian, H. E., Brim, W. R., Zeevi, T., Staib, L. H., Kazarian, E., Lin, M., et al. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.856231 · Cited by 26
Dhana, A. V., Hamada, Y., Kengne, A. P., Kerkhoff, A. D., Broger, T., Denkinger, C. M., Rangaka, M. X., Gupta‐Wright, A., Fielding, K., Wood, R., et al. (2022) · Journal of Infection · doi:10.1016/j.jinf.2022.05.010 · Cited by 24
Makino, Y., Miyake, K., Okada, A., Ikeda, Y., & Okada, Y. (2022) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.15292 · Cited by 26
Huibertse, L. J., Peters, Y., Westendorp, D., & Siersema, P. D. (2022) · Diseases of the Esophagus · doi:10.1093/dote/doac045 · Cited by 22
Kim, Y., Lee, S., Shin, J., Son, W. J., Roh, Y. H., Hwang, J. A., & Lee, J. E. (2022) · European Radiology · doi:10.1007/s00330-022-08985-z · Cited by 24
Davenport, C. F., Rai, N., Sharma, P., Deeks, J. J., Berhane, S., Mallett, S., Saha, P., Solanki, R., Bayliss, S. E., Snell, K. I. E., et al. (2022) · Cancers · doi:10.3390/cancers14153621 · Cited by 26
Self-citationRapid Diagnosis of XDR and Pre-XDR TB: A Systematic Review of Available Tools
Saderi, L., Puci, M. V., Lorenzo, B. D., Centis, R., D’Ambrosio, L., Akkerman, O. W., Alffenaar, J. C., Caminero, J. A., Chakaya, J. M., Denholm, J. T., et al. (2022) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2022.07.012 · Cited by 22
Gu, F., Wu, X., Wu, W., Wang, Z., Yang, X., Chen, Z., Wang, Z., & Chen, G. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110457 · Cited by 26
Huo, H., Shen, S., He, D., Liu, B., & Yang, F. (2022) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-022-00581-y · Cited by 22
Xu, C., Lin, S., Mao, L., & Li, Z. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.859318 · Cited by 26
Karkia, R., Wali, S., Payne, A. M., Karteris, E., & Chatterjee, J. (2022) · Cancers · doi:10.3390/cancers14194666 · Cited by 23
Galvano, A., Castellana, L., Gristina, V., Mantia, M. L., Insalaco, L., Barraco, N., Perez, A., Cutaia, S., Calò, V., Russo, T. D. B., et al. (2022) · Therapeutic Advances in Medical Oncology · doi:10.1177/17588359221110162 · Cited by 26
Pelletti, G., Rafael Boscolo-berto, A., Barone, R., Giorgetti, A., Fiorentini, C., Pascali, J. P., Fais, P., & Pelotti, S. (2022) · Forensic Science International · doi:10.1016/j.forsciint.2022.111479 · Cited by 23
Nabizadeh, F., Ramezannezhad, E., Kargar, A., Sharafi, A. M., & Ghaderi, A. (2022) · Neurological Sciences · doi:10.1007/s10072-022-06460-7 · Cited by 24
Shin, C. M., & Villa, E. C. (2022) · ULTRASONOGRAPHY · doi:10.14366/usg.22103 · Cited by 22
Cohen, S. E., Zantvoord, J. B., Wezenberg, B. N., Daams, J. G., Bockting, C., Denys, D. A. J. P., & van Wingen, G. A. (2022) · Journal of Affective Disorders · doi:10.1016/j.jad.2022.10.042 · Cited by 24
Li, J., Zhou, Q., & Deng, B. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03458-x · Cited by 22
Hosseini, P., Whincup, R., Devan, K., Ghanem, D. A., Fanshawe, J. B., Saini, A., Cross, B., Vijay, A., Mastellari, T., Vivekananda, U., et al. (2023) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101808 · Cited by 23
Liu, Y., Ma, W., & Liu, J. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12041477 · Cited by 22
Clinical Practice Guideline for Gastritis in Korea
Kang, S. J., Kim, J. G., Moon, H. S., Kook, M., Lee, J. Y., Bang, C. S., Tae, C. H., Gong, E. J., Nam, S. Y., & Kim, H. J. (2023) · Journal of Korean Medical Science · doi:10.3346/jkms.2023.38.e115 · Cited by 24
MicroRNA expression in osteoarthritis: a meta-analysis
Liu, H., Yan, L., Li, X., Li, D., Wang, G., Shen, N., Li, J. J., & Wang, B. (2023) · Clinical and Experimental Medicine · doi:10.1007/s10238-023-01063-8 · Cited by 25
Radić, M., Đogaš, H., Gelemanović, A., Petricevic, S. J., Škopljanac, I., & Radić, J. (2023) · Diagnostics · doi:10.3390/diagnostics13081429 · Cited by 27
The Diagnostic Power of Circulating miR-1246 in Screening Cancer: An Updated Meta-analysis
Khanh, H. Q., Le, A. T., Phan, T. T., Ho, T. T., Pho, S. P., Nguyen, H. T., Anh, L. T., Nguyen, T. T., & Nguyen, S. T. (2023) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2023/8379231 · Cited by 22
Elasifer, H., Amukwaya, M. M. N., Bhatia, R., Cuschieri, K. S., & Gregory, J. M. (2023) · Journal of Clinical Virology · doi:10.1016/j.jcv.2023.105469 · Cited by 22
Briard, J. N., Nitulescu, R., Lemoine, É., Titova, P., McIntyre, L., English, S. W., Knoll, G. A., Shemie, S. D., Martin, C. M., Turgeon, A. F., et al. (2023) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-023-02426-1 · Cited by 23
Papin, M., Latour, C., Leclère, B., & Javaudin, F. (2023) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001043 · Cited by 25
Siakallis, L. C., Topriceanu, C., Panovska‐Griffiths, J., & Bisdas, S. (2023) · Neuroradiology · doi:10.1007/s00234-023-03154-5 · Cited by 24
An, Q., Lin, R., Yang, Q., Wang, C., & Wang, D. (2023) · Journal of Global Antimicrobial Resistance · doi:10.1016/j.jgar.2023.05.001 · Cited by 23
Sabino-Silva, R., Cardoso, I. V., Vitali, F. C., Alves, A. M. H., de Souza, B. D. M., Bortoluzzi, E. A., Garcia, L. D. F. R., & Teixeira, C. D. S. (2023) · Clinical Oral Investigations · doi:10.1007/s00784-023-05151-7 · Cited by 28
Red flags to screen for vertebral fracture in people presenting with low back pain
Han, C. S., Hancock, M. J., Downie, A., Jarvik, J. G., Koes, B. W., Machado, G. C., Verhagen, A. P., Williams, C. M., Chen, Q., & Maher, C. G. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014461.pub2 · Cited by 42
Radiomics Analysis in Characterization of Salivary Gland Tumors on MRI: A Systematic Review
Mao, K., Wong, L. M., Zhang, R., So, T. Y., Shan, Z., Hung, K. F., & Ai, Q. Y. H. (2023) · Cancers · doi:10.3390/cancers15204918 · Cited by 24
Chen, H., Shen, Y., Wu, S., Zhu, Q., Weng, C., Zhang, J., Wang, M., & Jiang, W. (2023) · World Journal of Gastroenterology · doi:10.3748/wjg.v29.i39.5503 · Cited by 25
“Two reviewers (Chen H and Shen Y) independently assessed the risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 tool[16].”
Study designs in medical research and their key characteristics
Nowak, J. (2024) · Journal of Medical Science · doi:10.20883/medical.e928 · Cited by 32
Palmirotta, C., Aresta, S., Battista, P., Tagliente, S., Lagravinese, G., Mongelli, D., Gelao, C., Fiore, P., Castiglioni, I., Minafra, B., et al. (2024) · Brain Sciences · doi:10.3390/brainsci14020137 · Cited by 24
Ma, N., Yang, W., Wang, Q., Cui, C., Hu, Y., & Wu, Z. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1281572 · Cited by 26
Chen, Y., Wang, J., & Niu, T. (2024) · BMC Infectious Diseases · doi:10.1186/s12879-024-09073-x · Cited by 23
Ramusino, M. C., Massa, F., Festari, C., Gandolfo, F., Nicolosi, V., Orini, S., Nobili, F. M., Frisoni, G. B., Morbelli, S. D., Garibotto, V., et al. (2024) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-024-06631-y · Cited by 25
“The quality of the included studies was critically assessed by the six reviewers, according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [24].”
Abbatecola, A. M., Giuliani, A., Biscetti, L., Scisciola, L., Battista, P., Barbieri, M., Sabbatinelli, J., & Olivieri, F. (2024) · Ageing Research Reviews · doi:10.1016/j.arr.2024.102257 · Cited by 23
Kim, T., Woo, S., Lee, D. H., Do, R. K., & Chernyak, V. (2024) · European Radiology · doi:10.1007/s00330-024-10671-1 · Cited by 22
“The methodological quality of included studies was assessed based on Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria [22], using the tailored signaling questions (Supplementary Table 2).”
Vardarli, I., Tan, S., Görges, R., Krämer, B. K., Herrmann, K., & Brochhausen, C. (2024) · Endocrine Connections · doi:10.1530/ec-24-0170 · Cited by 22
Wang, T., Hong, J., Chiu, H., Chao, H., Chen, Y., & Wu, Y. (2024) · European Radiology · doi:10.1007/s00330-024-10804-6 · Cited by 27
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.