QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 5,701–5,800 of 14,770
Advanced optical imaging techniques for bladder cancer detection and diagnosis: a systematic review
Remmelink, M. J., Rip, Y., Nieuwenhuijzen, J. A., Ket, J. C. F., Oddens, J. R., de Reijke, T. M., & de Bruin, D. M. (2024) · British Journal of Urology · doi:10.1111/bju.16471 · Cited by 20
“Risk of bias and applicability of the research was evaluated by the Quality Assessment of Diagnostic Accuracy Studies 2 tool in case of cohort studies [35].”
HajiEsmailPoor, Z., Kargar, Z., Baradaran, M., Shojaeshafiei, F., Tabnak, P., Mandalou, L., Klontzas, M. E., & Shahidi, R. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111652 · Cited by 21
FDG-PET-CT as an early detection method for tuberculosis: a systematic review and meta-analysis
Yayan, J., Rasche, K., Franke, K.-J., Windisch, W., & Berger, M. P. (2024) · BMC Public Health · doi:10.1186/s12889-024-19495-6 · Cited by 20
Rop, L. D., Bos, D. A. G., Stegeman, I., Holtman, G. A., Ochodo, E., Spijker, R., Otieno, J. A., Alkhlaileh, F., Deeks, J. J., Dinnes, J., et al. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015050.pub2 · Cited by 26
Self-citationLi, H., Zhao, J., & Jiang, Z. (2024) · Clinical Radiology · doi:10.1016/j.crad.2024.08.002 · Cited by 22
Zhao, T., Wang, B., Liang, W., Cheng, S., Wang, B., Cui, M., & Shou, J. (2024) · Academic Radiology · doi:10.1016/j.acra.2024.08.016 · Cited by 22
Dashti, M., Ghaedsharaf, S., Ghasemi, S., Zare, N., Constantin, E.-F., Fahimipour, A., Tajbakhsh, N., & Ghadimi, N. (2024) · Imaging Science in Dentistry · doi:10.5624/isd.20240038 · Cited by 20
Vincent, R., Charron, M., Lafrance, S., Cormier, A., Kairy, D., & Desmeules, F. (2024) · Journal of Medical Internet Research · doi:10.2196/52964 · Cited by 23
“Methodological quality of included studies was assessed with the valid and reliable Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [38].”
Baharun, N. B., Adam, A., Zailani, M. A. H., Rajpoot, N., Xu, Q., & Zin, R. R. M. (2024) · BMC Cancer · doi:10.1186/s12885-024-12962-8 · Cited by 25
“Lastly, the quality and risk of bias in each study were assessed by two investigators using the QUADAS-2 tool to characterize each study in four domains (Patient election; Index test; Reference standard; Flow and timing) [27].”
MethodMorales, N. O., & García, P. (2024) · European Public & Social Innovation Review · doi:10.31637/epsir-2024-1605 · Cited by 20
Dávila-Rúales, V., Córdoba, L. F. G., Medina, A. M. G., Múñoz, Ó., Serrano, M. N., & Henao, D. C. (2024) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188241304459 · Cited by 22
Zhang, F., Han, H., Li, M., Tian, T., Zhang, G., Yang, Z., Guo, F., Li, M., Wang, Y., Wang, J., et al. (2025) · Frontiers in Microbiology · doi:10.3389/fmicb.2024.1510026 · Cited by 20
Omar, M., Nassar, S., Sharif, Κ., Glicksberg, B. S., Nadkarni, G. N., & Klang, E. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2024.1512824 · Cited by 26
Pan, Y., Wang, P., Xue, B., Liu, Y., Shen, X., Wang, S., & Wang, X. (2025) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1515549 · Cited by 28
Salinas-Miranda, E., Birosh, A., McInnes, M. D. F., Breau, R. H., Lam, E., McGrath, T. A., Flood, T. A., & Schieda, N. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.24.32328 · Cited by 21
Chen, L., Zhang, L., Liang, M., Bao, J., Zhang, J., Xia, Y., Huang, X., & Wang, J. (2014) · Academic Radiology · doi:10.1016/j.acra.2014.08.003 · Cited by 20
Psychometric Properties of the Cardiac Depression Scale: A Systematic Review
Chavez, C. A., Ski, C. F., & Thompson, D. R. (2014) · Heart Lung and Circulation · doi:10.1016/j.hlc.2014.02.020 · Cited by 27
Yan, S., Liu, Z. J., Yu, S., & Bao, Y. (2015) · Genetics and Molecular Research · doi:10.4238/2015.september.28.9 · Cited by 20
Autosomal Dominant Polycystic Kidney Disease: A Path Forward
Rangan, G. K., Lopez‐Vargas, P. A., Nankivell, B. J., Tchan, M. C., Tong, A., Tunnicliffe, D. J., & Savige, J. (2015) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2015.10.002 · Cited by 20
Owora, A. H., Carabin, H., Reese, J. A., & Garwe, T. (2016) · Journal of Affective Disorders · doi:10.1016/j.jad.2016.05.015 · Cited by 21
Radiolabeled choline PET/CT before salvage lymphadenectomy dissection
Evangelista, L., Zattoni, F., Karnes, R. J., Novara, G., & Lowe, V. J. (2016) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000582 · Cited by 20
On‐site test to detect syphilis in pregnancy: a systematic review of test accuracy studies
Rogozińska, E., Kara-Newton, L., Zamora, J. O., & Khan, K. S. (2016) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14455 · Cited by 25
Tan, X. W., Zheng, Q., Shi, L., Gao, F., Allen, J. C., Coenen, A., Baumann, S., Schoepf, U. J., Kassab, G. S., Lim, S. T., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.053 · Cited by 20
Bankova, A. K., Andres, Y., Horn, M. P., Alberio, L., & Nagler, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178289 · Cited by 20
Shi, H., Yu, J., Yu, J., Zheng, F., Zhang, C., Li, G., Zhao, R., & Yang, X. (2017) · World Journal of Surgical Oncology · doi:10.1186/s12957-017-1201-9 · Cited by 20
de Morais, É. F., Dantas, A. N., Pinheiro, J. C., Leite, R. B., Barboza, C. A. G., Gurgel, B. C. D. V., & Freitas, R. D. A. (2017) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2017.12.008 · Cited by 20
Trimboli, P., & Giovanella, L. (2018) · ULTRASONOGRAPHY · doi:10.14366/usg.17066 · Cited by 20
von Meijenfeldt, G. C. I., Vainas, T., Mistriotis, G. A., Gans, S. L., Zeebregts, C. J., & van der Laan, M. J. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.008 · Cited by 20
Diagnostic efficacy of long non-coding RNA in lung cancer: a systematic review and meta-analysis
Dai, S., Jin, J., & Li, W. (2018) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2018-135862 · Cited by 20
Barrientos‐Trigo, S., Gil‐García, E., Romero‐Sánchez, J. M., Badanta, B., & Pórcel‐Gálvez, A. M. (2018) · International Nursing Review · doi:10.1111/inr.12495 · Cited by 21
Cai, Y., Liu, D., Cui, J., Sha, Y., Zhou, H., Tang, N., Wang, N., Huang, A., & Xia, J. L. (2019) · Medicine · doi:10.1097/md.0000000000015096 · Cited by 20
Vojnov, L., Taegtmeyer, M., Boeke, C. E., Markby, J. L., Harris, L., Doherty, M. C., PETER, T. F., & Ford, N. P. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216277 · Cited by 20
Beyer, A. K., Córdoba, G., & Holm, A. (2019) · Scandinavian Journal of Primary Health Care · doi:10.1080/02813432.2019.1639935 · Cited by 20
Chen, J., Zhou, C., He, M., Zhen, Z., Wang, J., & Hu, X. (2019) · Cancer Management and Research · doi:10.2147/cmar.s200318 · Cited by 20
Zhang, N., Wang, X., Wang, C., Chen, S., Wu, J., Zhang, G., Zhu, W., Liu, J., Xu, B., Du, M., et al. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00981 · Cited by 20
Saliba, R., Aho, S., Karam‐Sarkis, D., & Zahar, J. (2019) · Journal of Hospital Infection · doi:10.1016/j.jhin.2019.11.017 · Cited by 21
Weir-McCall, J. R., Joyce, S., Clegg, A. J., Mackay, J., Baxter, G. C., Dendl, L. M., Rintoul, R. C., Qureshi, N. R., Miles, K. A., & Gilbert, F. J. (2020) · European Radiology · doi:10.1007/s00330-020-06661-8 · Cited by 22
Abbasi, A., Rabori, P. M., Farajollahi, R., Ali, K. M., Ataei, N., Yousefifard, M., & Hosseini, M. (2020) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v8i1.585 · Cited by 20
Whether drug detection in urine and oral fluid is similar? A systematic review
Martini, M. B. A., Batista, T. B. D., Henn, I. W., de Souza, P. T. D. R., Vieira, A. R., & Azevedo‐Alanis, L. R. (2020) · Critical Reviews in Toxicology · doi:10.1080/10408444.2020.1751062 · Cited by 21
Tian, L., Wang, L., Qin, Y., & Cai, J. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15309 · Cited by 20
“Quality of the Studies The risk of bias in individual studies was assessed in accordance with the Quality Assessment of Diagnostic Accuracy Studies 2 checklist.(20) Each article was independently evaluated by the reviewers (L.”
Nasi, D., Meletti, S., Tramontano, V., & Pavesi, G. (2020) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2020.105954 · Cited by 20
Rapid immunochromatographic tests for the diagnosis of dengue: a systematic review and meta-analysis
Mata, V. E., de Andrade, C. A. F., Passos, S. R. L., Hökerberg, Y. H. M., Fukuoka, L. V. B., & da Silva, S. A. (2020) · Cadernos de Saúde Pública · doi:10.1590/0102-311x00225618 · Cited by 23
Wu, Z., Xu, Z., Yu, B., Zhang, J., & Yu, B. (2020) · BioMed Research International · doi:10.1155/2020/6786875 · Cited by 22
Gao, Y.-M., Wang, B., Cao, J.-Y., Feng, S., & Liu, B. (2020) · BioMed Research International · doi:10.1155/2020/2768326 · Cited by 20
Kim, S., Kim, Y. S., & Kim, S. (2020) · Journal of Cardiology · doi:10.1016/j.jjcc.2020.07.003 · Cited by 24
Zhai, C., Li, R., Hou, K., Chen, J., Alzogool, M., Hu, Y., Zhang, J., Yingyi, Z., Wang, L., Zhang, R., et al. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00691 · Cited by 20
Liang, J., Li, J., Li, Z., Meng, T., Chen, J., Ma, W., Shen, C., Xie, L., Wu, Y., & He, N. (2020) · BMC Cancer · doi:10.1186/s12885-020-07308-z · Cited by 20
Li, X.-M., Liu, C., Mao, Z., Qi, S., Song, R., & Zhou, F. (2020) · Journal of Interventional Cardiology · doi:10.1155/2020/1035089 · Cited by 21
Grubb, M., Golden, A., Withers, A., Vellone, D. A., Young, A., & McLachlan, K. (2021) · Alcoholism Clinical and Experimental Research · doi:10.1111/acer.14657 · Cited by 22
Telford, L. H., Abdullahi, L. H., Ochodo, E., Zuhlke, L. J., & Engel, M. E. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-038449 · Cited by 21
Janczyk, E. M., Champigny, N., Michel, É., Raffaelli, C., Annweiler, C., Zory, R., Guérin, O., & Sacco, G. (2020) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1293-8057 · Cited by 24
Meta-Analysis of Dyslipidemia Management for the Prevention of Ischemic Stroke Recurrence in China
Chen, K., He, L., Zhong, L., Ran, Y., & Liu, Y. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.483570 · Cited by 23
Identifying Ovarian Cancer in Symptomatic Women: A Systematic Review of Clinical Tools
Funston, G., Hardy, V., Abel, G., Crosbie, E. J., Emery, J. D., Hamilton, W. T., & Walter, F. M. (2020) · Cancers · doi:10.3390/cancers12123686 · Cited by 26
Component-Resolved Diagnosis of Hazelnut Allergy in Children
Caffarelli, C., Mastrorilli, C., Santoro, A., Criscione, M., & Procaccianti, M. (2021) · Nutrients · doi:10.3390/nu13020640 · Cited by 21
Udomkarnjananun, S., Kerr, S. J., Francke, M. I., Avihingsanon, Y., van Besouw, N. M., Baan, C. C., & Hesselink, D. A. (2021) · Journal of Clinical Virology · doi:10.1016/j.jcv.2021.104848 · Cited by 20
Zhang, Q., Huang, J., He, Y., Cao, R., & Shu, J.-C. (2021) · Endocrine · doi:10.1007/s12020-021-02754-6 · Cited by 20
Hai, Y., Chong, W., Eisenbrey, J. R., & Forsberg, F. (2021) · Digestive Diseases and Sciences · doi:10.1007/s10620-021-07168-y · Cited by 20
The role of 18F-FDG PET/CT radiomics in lymphoma
Rizzo, A., Triumbari, E. K. A., Gatta, R., Boldrini, L., Racca, M., Mayerhoefer, M. E., & Annunziata, S. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00451-y · Cited by 20
Burden‐Teh, E., Murphy, R., Gran, S., Nijsten, T. E. C., Hughes, C., Abdul‐Wahab, A., Bewley, A., Burrows, N., Darné, S., Gach, J. E., et al. (2021) · British Journal of Dermatology · doi:10.1111/bjd.20689 · Cited by 20
den Broeck, J. V., Buzzatti, L., Jager‐Wittenaar, H., Perkisas, S., & Scafoglieri, A. (2021) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2021.08.012 · Cited by 22
Ambrosino, P., Accardo, M., Mosella, M., Papa, A., Fuschillo, S., Spedicato, G. A., Motta, A., & Maniscalco, M. (2021) · Annals of Medicine · doi:10.1080/07853890.2021.1979242 · Cited by 21
Litwinowicz, K., Waszczuk, E., & Gamian, A. (2021) · Nutrients · doi:10.3390/nu13103370 · Cited by 20
The accuracy of diagnostic indicators for coeliac disease: A systematic review and meta-analysis
Elwenspoek, M. M. C., Jackson, J., O’Donnell, R., Sinobas, A. D., Dawson, S., Everitt, H., Gillett, P. M., Hay, A. D., Lane, D., Mallett, S., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0258501 · Cited by 20
Self-citationZhang, Y., Gao, J., Bao, Y. J., Liu, Y., Tong, Y., Jin, S., & Zhao, Q. (2021) · Biomarkers · doi:10.1080/1354750x.2021.2008009 · Cited by 23
Rana, P., Gupta, P. C., Kalage, D., Soundararajan, R., Kumar, P. M., & Dutta, U. (2021) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2021.2011210 · Cited by 20
Manhoobi, I. P., Bodilsen, A., Nijkamp, J. A., Pareek, A., Tramm, T., Redsted, S., & Christiansen, P. (2022) · Academic Radiology · doi:10.1016/j.acra.2021.12.006 · Cited by 26
The detection of delirium in admitted oncology patients: a scoping review
Sands, M. B., Wee, I., Agar, M. R., & Vardy, J. L. (2022) · European Geriatric Medicine · doi:10.1007/s41999-021-00586-1 · Cited by 20
Ghoneim, S., Wang, J., Chehade, N. E. H., Ganocy, S. J., Chitsaz, E., & Fass, R. (2022) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0000000000001686 · Cited by 20
Emerging Technologies for Dentin Caries Detection—A Systematic Review and Meta-Analysis
Serban, C., Lungeanu, D., Bota, S. I., Cotca, C. C., Negruțiu, M. L., Duma, V.-F., Sinescu, C. G., & Crăciunescu, E. L. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11030674 · Cited by 23
Tanaka, A., Matsuo, K., Kikuchi, M., Kojima, S., Hanada, H., Mano, T., Nakashima, T., Hashiba, K., Yamamoto, T., Yamaguchi, J., et al. (2022) · Circulation Reports · doi:10.1253/circrep.cr-22-0002 · Cited by 20
Motion Tracking Algorithms Based on Wearable Inertial Sensor: A Focus on Shoulder
Longo, U. G., Salvatore, S. D., Sassi, M., Carnevale, A., Luca, G. D., & Denaro, V. (2022) · Electronics · doi:10.3390/electronics11111741 · Cited by 23
Wu, Y., Zhu, M., Liu, Y., Cao, X., Zhang, G., & Yin, L.-L. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.907076 · Cited by 22
Boer, O. D., Marroun, H. E., & Franken, I. H. A. (2022) · Brain Research · doi:10.1016/j.brainres.2022.148020 · Cited by 22
Smith, R. D., Shing, J. S. Y., Lin, J., Bosanquet, K., Fong, D., & Lok, K. Y. W. (2022) · Journal of Affective Disorders · doi:10.1016/j.jad.2022.07.026 · Cited by 24
Liu, X., Song, W., Mao, T., Zhang, Q., Zhang, C., & Li, X. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.915481 · Cited by 23
Rizzo, A., Racca, M., Albano, D., Dondi, F., Bertagna, F., Annunziata, S., & Treglia, G. (2022) · Pharmaceuticals · doi:10.3390/ph15111368 · Cited by 20
Dimitriadis, A., Trivizakis, E., Papanikolaou, N. K., Tsiknakis, M., & Marias, K. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01315-3 · Cited by 25
Fang, Y., Chen, N. N., Cheng, Y., Sun, S.-Z., Li, H., Sun, F., & Xiang, Y. (2015) · Lupus · doi:10.1177/0961203315600244 · Cited by 20
MicroRNAs as potential diagnostic biomarkers in renal cell carcinoma
Gao, Y., Zhao, H., Lu, Y., Li, H., & Yan, G. (2014) · Tumor Biology · doi:10.1007/s13277-014-2381-3 · Cited by 20
MicroRNAs as novel biomarkers for pancreatic cancer diagnosis: a meta-analysis based on 18 articles
Ding, Z., Wu, H.-R., Zhang, J., Huang, G., & Ji, D. (2014) · Tumor Biology · doi:10.1007/s13277-014-2133-4 · Cited by 20
Høyer, C., Sandermann, J., Paludan, J. P. D., Pavar, S., & Petersen, L. J. (2013) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2013.06.057 · Cited by 20
Diagnostic accuracy of computed tomography perfusion in patients with acute stroke: A meta-analysis
Ye, X., & Han, F. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.11.046 · Cited by 20
Assasi, N., Blackhouse, G., Campbell, K., Hopkins, R. B., Levine, M., Richter, T. A., & Budden, A. (2015) · PubMed · Cited by 51
A Systematic Review of Research Gaps in the Evaluation and Management of Localized Renal Masses
Patel, H. D., Iyoha, E., Pierorazio, P. M., Sozio, S. M., Johnson, M. H., Sharma, R., Bass, E. B., & Allaf, M. E. (2016) · Urology · doi:10.1016/j.urology.2016.08.013 · Cited by 20
Steen, W., Blom, R. L. G. M., Busch, O. R., Gerhards, M. F., Besselink, M. G., Dijk, F., & Festen, S. (2016) · Journal of Surgical Oncology · doi:10.1002/jso.24402 · Cited by 20
Wu, Y., Chen, K., & Terkeltaub, R. A. (2016) · RMD Open · doi:10.1136/rmdopen-2016-000339 · Cited by 20
Marchello, C. S., & Ebell, M. H. (2016) · The Annals of Family Medicine · doi:10.1370/afm.2005 · Cited by 20
Exhaled nitric oxide in the diagnosis of asthma in adults: a systematic review
Harnan, S., Essat, M., Gomersall, T., Tappenden, P., Pavord, I. D., Everard, M. L., & Lawson, R. A. (2016) · Clinical & Experimental Allergy · doi:10.1111/cea.12867 · Cited by 20
Cadieux, G., Campbell, J. R., & Dendukuri, N. (2016) · CMAJ Open · doi:10.9778/cmajo.20160084 · Cited by 20
Yung, D. E., Fernández-Urién, I., Douglas, S., Plevris, J. N., Sidhu, R., McAlindon, M. E., Panter, S. J., & Koulaouzidis, A. (2017) · United European Gastroenterology Journal · doi:10.1177/2050640616687232 · Cited by 20
ShP, L., Wang, Y., Huang, L., Wang, F., Zhou, J.-G., & Ma, H. (2017) · Europe PMC (PubMed Central) · doi:10.22034/apjcp.2017.18.2.391 · Cited by 20
Zheng, D., Tian, W., Zheng, Z., Gu, J., Guo, Z., & He, X. (2017) · Clinical Transplantation · doi:10.1111/ctr.13013 · Cited by 20
Dong, F., Zhang, L., Wang, S., Dong, D., Xu, J., Wu, H., Liu, Y., & Li, M. (2018) · Medical Ultrasonography · doi:10.11152/mu-1252 · Cited by 23
Serum galactomannan for diagnosing invasive aspergillosis in pediatric patients: A meta-analysis
Tong, T., Jilu, S., & Xu, Y. (2018) · Microbial Pathogenesis · doi:10.1016/j.micpath.2018.03.059 · Cited by 20
Lee, S. H., Yun, S. J., Jin, W., Park, S. Y., Park, J. S., & Ryu, K. N. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26024 · Cited by 20
Willits, I., Cole, H., Jones, R., Dimmock, P. W., Arber, M. R., Craig, J., & Sims, A. J. (2015) · Applied Health Economics and Health Policy · doi:10.1007/s40258-015-0181-6 · Cited by 21
Writing a Systematic Review and Meta-analysis: A Step-by-Step Guide
Dagher, D., & Khan, M. (2025) · Sports Health A Multidisciplinary Approach · doi:10.1177/19417381251364686 · Cited by 20
“2,12 Each tool evaluates specific risk areas, allowing reviewers to critically appraise the methodological rigor of included studies, identify potential sources of bias, and assess the reliability of the evidence base upon which conclusions are drawn.”
Zhao, Y., Zhao, Y., Wang, C., Liang, Z., & Liu, X. (2019) · Endocrine Practice · doi:10.4158/ep-2019-0098 · Cited by 19
Guo, E., Xu, L., Zhang, D., Zhang, J., Zhang, X., Bai, X., Chen, L., Peng, Q., Zhang, G., Jin, Z., et al. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01699-4 · Cited by 24
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.