QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 5,801–5,900 of 14,770
Wong, B., Wu, P., Ismail, Z., Watt, J. A., & Goodarzi, Z. (2024) · BMC Geriatrics · doi:10.1186/s12877-024-05143-6 · Cited by 22
Essed, R. A., Prysiazhniuk, Y., Wamelink, I. J. H. G., Azizova, A., & Keil, V. C. (2024) · European Radiology · doi:10.1007/s00330-024-11004-y · Cited by 26
“Risk of bias and applicability were assessed using a modi fi ed version of the ‘ Quality Assessment of Diagnostic Accuracy Studies-2 ’ (QUADAS-2) tool [16].”
Lombardi, G., Pancani, S., Manca, R., Mitolo, M., Baiardi, S., Massa, F., Coppola, L., Franzese, M., Nicolai, E., Guerini, F. R., et al. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252312916 · Cited by 23
The scientific evidence of commercial AI products for MRI acceleration: a systematic review
Fransen, S. J., Roest, C., Simonis, F. F. J., Yakar, D., & Kwee, T. C. (2025) · European Radiology · doi:10.1007/s00330-025-11423-5 · Cited by 25
“In line with the QUADAS-2 guidelines [15], the evidence levels were merged into three classi fi cations that indicate the strength of the clinical relevance of the reported method to evaluate the reconstructed image quality: levels 5 and 6 were interpreted as a high evidence level, levels 3 and 4 as…”
Mick, I., Freger, S., Marien, M., Gholiof, M., & Leonardi, M. (2025) · O&G Open · doi:10.1097/og9.0000000000000061 · Cited by 27
“20 This is a diagnostic test accuracy study completed at McMaster University Medical Center, Hamilton Health Sciences, Canada.”
Tarighatnia, A., Amanzadeh, M., Hamedan, M., Mohammadnia, A., & Nader, N. D. (2025) · BMC Medical Imaging · doi:10.1186/s12880-025-01626-z · Cited by 23
“Two raters (M.A. and A.T.) independently evaluated potential bias risks in selected studies using the QUA-DAS-2 tool, which comprises four key domains: (1) patient selection, (2) index test, (3) reference standard, and (4) flow and timing [13].”
Blaser, A. R., Koitmäe, M., Laisaar, K.-T., Forbes, A., Kase, K., Kiisk, E., Murruste, M., Reim, M., Starkopf, J., & Tamme, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-94846-w · Cited by 28
Current Technological Advances in Dysphagia Screening: Systematic Scoping Review
Wong, D. W., Wang, J., Cheung, S. M.-Y., Lai, D. K.-H., Chiu, A. T. S., Pu, D., Cheung, J. C., & Kwok, T. C. Y. (2025) · Journal of Medical Internet Research · doi:10.2196/65551 · Cited by 22
“To evaluate the methodological quality of the included studies, we used a modified version of the Quality Assessment of Diagnostic Accuracy Studies–2 (QUADAS-2) tool [33], dubbed QUADAS-2+M.”
Deshpande, S., Tarawneh, H., Deitelzweig, C., Tong, J., Zhou, T., Chen, Y., & Cuker, A. C. (2025) · Blood · doi:10.1182/blood.2025028416 · Cited by 19
Rai, J., Mai, D. V. C., Drami, I., Pring, E. T., Gould, L. E., Lung, P. F. C., Glover, T. E., Shur, J. D., Whitcher, B. J., Athanasiou, T., et al. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-04953-5 · Cited by 21
Schwab, S., & NONAKA, T. (2025) · Frontiers in Genetics · doi:10.3389/fgene.2025.1574586 · Cited by 22
Abdulrahman, M., Giesel, F. L., Scott, A. M., Shi, H., Zaidi, H., Abdlkadir, A. S., Yaser, S., Abu-Hijlih, R. A., & Al‐Ibraheem, A. (2025) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-025-00936-y · Cited by 19
“Next, the methodological quality of the included arti - cles discussing diagnostic utility of FAPI in STS was independently assessed for risk of bias and methodological application using the standardized Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) protocol [ 14 ].”
Multicancer Detection Tests for Screening: A Systematic Review
Kahwati, L. C., Avenarius, M. R., Brouwer, L., Crossnohere, N. L., Doubeni, C. A., Miller, C. R., Siddiqui, M., Voisin, C. E., Wines, R., & Jonas, D. E. (2025) · Annals of Internal Medicine · doi:10.7326/annals-25-01877 · Cited by 26
Obara, K., Ito, D., Nilsson, C., Janelidze, S., Santillo, A. F., Katsuno, M., & Mattsson, N. (2025) · European Journal of Neurology · doi:10.1111/ene.70382 · Cited by 24
“For diagnostic studies included in the meta-analysis, the risk of bias (RoB) was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [29] protocol by KO and DI independently.”
Moise, K. J., Markham, K. B., Spinella, P. C., Sherwood, M. R., Robinson, K. A., Wilson, L. M., Malone, J. R., Espinoza, J., Dizon‐Townson, D., Mercer, L. T., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.44649 · Cited by 21
Wang, T.-W., Luo, W.-T., Tu, Y.-K., Chou, Y.-B., & Wu, Y.-T. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-02223-8 · Cited by 26
Gao, S., Liu, J., Li, L., Yang, D., Miao, Y., Zhang, X., Han, Q., Shi, Y., Wu, J., & Zhang, K. (2026) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01502-5 · Cited by 21
“The methodological quality and risk of bias of the included diagnostic accuracy studies were evaluated using the QUADAS-2 tool [40].”
Diagnostic Accuracy of circRNAs in Esophageal Cancer: A Meta-Analysis
Niu, C., Zhao, L. Q., Guo, X., Shen, Y., Shao, Y., & Liu, F. (2019) · Disease Markers · doi:10.1155/2019/9673129 · Cited by 20
Properties of Pain Assessment Tools for Use in People Living With Stroke: Systematic Review
Edwards, S., Ioannou, A., Carin-Levy, G., Cowey, E., Brady, M., Morton, S., Sande, T. A., Mead, G. E., & Quinn, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00792 · Cited by 19
Squizzato, A., Maroni, L., Marrazzo, C., Riva, N., & Guasti, L. (2020) · Emergency Medicine Journal · doi:10.1136/emermed-2019-208547 · Cited by 19
Pierrakos, C. N., Smit, M. R., Hagens, L. A., Heijnen, N. F. L., Hollmann, M. W., Schultz, M. J., Paulus, F., & Bos, L. D. J. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.666941 · Cited by 20
Diagnostic Accuracy Studies in Radiology: How to Recognize and Address Potential Sources of Bias
Pavlou, A., Kurtz, R. M., & Song, J. W. (2021) · Radiology Research and Practice · doi:10.1155/2021/5801662 · Cited by 22
Nam, B. D., Yoon, S. H., Hong, H., Hwang, J. H., Goo, J. M., & Park, S. (2021) · Korean Journal of Radiology · doi:10.3348/kjr.2021.0244 · Cited by 21
Zhao, W., Liu, S., Cong, L., & Zhao, Y. (2021) · Annals of Surgical Oncology · doi:10.1245/s10434-021-10662-2 · Cited by 21
Jiwa, N., Kumar, S., Gandhewar, R., Chauhan, H., Nagarajan, V. R., Wright, C., Hadjiminas, D. J., Takáts, Z., Ashrafian, H., & Leff, D. R. (2021) · Annals of Surgical Oncology · doi:10.1245/s10434-021-11070-2 · Cited by 19
Li, W., Sun, Y., Wu, Y., Lu, F., & Xu, H. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.771864 · Cited by 21
Wu, S., Wang, J., Guo, Q., Lan, H., Zhang, J., Wang, L., Janne, E., Luo, X., Wang, Q., Song, Y., et al. (2021) · Intelligent Medicine · doi:10.1016/j.imed.2021.12.001 · Cited by 20
Zhou, X. (2022) · The International Journal of Biological Markers · doi:10.1177/17246008211068866 · Cited by 21
Traboulsi-Garet, B., Jorba‐García, A., Camps‐Font, O., Alves, F. A., Figueiredo, R., & Valmaseda‐Castellón, E. (2022) · Clinical Oral Investigations · doi:10.1007/s00784-022-04383-3 · Cited by 19
Ferré, R., & Kuzmiak, C. M. (2022) · Journal of Osteopathic Medicine · doi:10.1515/jom-2021-0206 · Cited by 19
Detection of asymptomatic malaria in Asian countries: a meta-analysis of diagnostic accuracy
Naing, C. M., Htet, N. H., Aye, S. N., Aung, H. H., Tanner, M., & Whittaker, M. A. (2022) · Malaria Journal · doi:10.1186/s12936-022-04082-0 · Cited by 19
Li, T., Houssami, N., Noguchi, N., Zeng, A., & Marinovich, M. L. (2022) · British Journal of Cancer · doi:10.1038/s41416-022-01790-x · Cited by 19
Kim, H. J., Gong, E. J., Bang, C. S., Lee, J. J., Suk, K. T., & Baik, G. H. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12040644 · Cited by 21
Jin, Y., Jung, J. H., Han, W. K., Hwang, E. C., Nho, Y., Lee, N. R., Yun, J. E., Lee, K. S., Lee, S. H., Lee, H., et al. (2022) · Korean journal of urology · doi:10.4111/icu.20210429 · Cited by 19
What are the best diagnostic tests for diagnosing bacterial arthritis of a native joint?
Walinga, A. B., Stornebrink, T., Langerhuizen, D. W. G., Struijs, P. A. A., Kerkhoffs, G. M. M. J., & Janssen, S. J. (2021) · The Bone & Joint Journal · doi:10.1302/0301-620x.103b12.bjj-2021-0114.r1 · Cited by 19
Huang, Y., Chen, Y., Tu, S., Zhang, J., Qiu, Y., & Yu, W. (2022) · BMC Infectious Diseases · doi:10.1186/s12879-022-07292-8 · Cited by 19
Deora, N., Yadav, C. P., Pande, V., & Sinha, A. (2022) · The Lancet Regional Health - Southeast Asia · doi:10.1016/j.lansea.2022.05.001 · Cited by 21
Khanagar, S. B., Alfouzan, K., Awawdeh, M. A., Alkadi, L., Albalawi, F., & Alghilan, M. A. (2022) · Applied Sciences · doi:10.3390/app12115581 · Cited by 23
Zayed, Y., Alzghoul, B. N., Hyde, R., Wadood, Z., Banifadel, M., Khasawneh, M., Maharrey, P. B., Saker, H., Harden, C., Barnes, G., et al. (2022) · Journal of Bronchology & Interventional Pulmonology · doi:10.1097/lbr.0000000000000865 · Cited by 21
Salivary noncoding RNA in the diagnosis of pancreatic cancer: Systematic review and meta‐analysis
Koopaie, M., Kolahdooz, S., Fatahzadeh, M., & Aleedawi, Z. A. (2022) · European Journal of Clinical Investigation · doi:10.1111/eci.13848 · Cited by 20
Lima, F. R., de Paula, N. A., Simões, M. M. R., Manso, G. M. D. C., Albertino, G. S., Felisbino, G. C., Antunes, V. M. G., Perecin, F. A. M. C., Westin, A. T., Lugão, H. B., et al. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.972244 · Cited by 19
Ager, M., Donegan, S., Boeri, L., de Castro, J. M., Donaldson, J. F., Omar, M. I., Dimitropoulos, K., Tharakan, T., Janisch, F., Muilwijk, T., et al. (2022) · British Journal of Urology · doi:10.1111/bju.15869 · Cited by 19
Kang, Y. J., Cho, J., & Hwang, S. H. (2022) · La radiologia medica · doi:10.1007/s11547-022-01540-2 · Cited by 19
Pompili, M., Ardito, F., Brunetti, E., Cabibbo, G., Calliada, F., Cillo, U., de Sio, I., Golfieri, R., Grova, M., Gruttadauria, S., et al. (2022) · Digestive and Liver Disease · doi:10.1016/j.dld.2022.08.031 · Cited by 23
The Diagnostic Value of Procalcitonin in Patients with Severe Acute Pancreatitis: A Meta-Analysis
Chen, L., & Jiang, J. (2022) · The Turkish Journal of Gastroenterology · doi:10.5152/tjg.2022.22098 · Cited by 19
Khan, R., Karim, M. N., Hosseini, F., & Fine, N. M. (2022) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2022.08.007 · Cited by 23
Khanagar, S. B., Alfouzan, K., Alkadi, L., Albalawi, F., Iyer, K., & Awawdeh, M. A. (2022) · Applied Sciences · doi:10.3390/app12199819 · Cited by 20
Hu, J., Cai, Z., & Zhou, Y. (2022) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/10760296221130061 · Cited by 19
Flanary, J. T., Daly, S. R., Bakker, C., Herman, A. B., Park, M. C., McGovern, R. A., Walczak, T. S., Henry, T. R., Netoff, T. I., & Darrow, D. (2022) · Epilepsia · doi:10.1111/epi.17446 · Cited by 22
Li, C., Sun, L., Liu, Y., Zhou, H., Chen, J., She, M., & Wang, Y. (2022) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/jcpt.13792 · Cited by 21
Jing, W., Luo, W., & Lou, L. (2022) · Brazilian Journal of Otorhinolaryngology · doi:10.1016/j.bjorl.2022.10.050 · Cited by 19
Roberts, C., Albusoda, A., Farmer, A. D., & Aziz, Q. (2022) · Neurogastroenterology & Motility · doi:10.1111/nmo.14515 · Cited by 21
Ozcan, B. B., Yan, J. W., Xi, Y., Baydoun, S. E., Scoggins, M. E., & Doğan, B. E. (2022) · European Journal of Breast Health · doi:10.4274/ejbh.galenos.2022.2022-12-1 · Cited by 19
Ye, Q., & Wang, Y. (2023) · Tropical Medicine & International Health · doi:10.1111/tmi.13849 · Cited by 20
Rokkas, T., & Ekmektzoglou, K. (2023) · Annals of Gastroenterology · doi:10.20524/aog.2023.0784 · Cited by 25
Anzola, L. K., Hernández-Hidalgo, N., Rodríguez, L. F., Sanguino, G., Martinez, E., Lopez, R., Moreno, S., Prill, R., Mut, F., Rasch, H. F., et al. (2023) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-023-03687-8 · Cited by 19
Downie, L. E., Britten‐Jones, A. C., Hogg, R. E., Jalbert, I., Li, T., Lingham, G., Liu, S., Qureshı, R., Saldanha, I. J., Singh, S., et al. (2023) · The Ocular Surface · doi:10.1016/j.jtos.2023.04.009 · Cited by 20
Prediction equations to estimate muscle mass using anthropometric data: a systematic review
Duarte, C. K., Silva, L. D. A., Castro, C. F., Ribeiro, M. V., Saldanha, M. F., Machado, A. M., & Jansen, A. K. (2023) · Nutrition Reviews · doi:10.1093/nutrit/nuad022 · Cited by 20
Berman, A., Anteby, R., Efros, O., Klang, E., & Soffer, S. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2023.04.027 · Cited by 23
Zhang, Y., Li, Y., Liu, J., Wang, J., Li, H. Y., Zhang, J., & Yu, X. (2023) · Eye · doi:10.1038/s41433-023-02551-7 · Cited by 21
Pelling, M., Chandrapalan, S., West, E. S., & Arasaradnam, R. P. (2023) · Cancers · doi:10.3390/cancers15082308 · Cited by 19
Artificial Intelligence in Diagnosis of Oral Diseases: A Systematic Review
Kolarkodi, S. H., & Alotaibi, K. Z. (2023) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-3465 · Cited by 20
Jacquot, R., Sève, P., Jackson, T. L., Wang, T., Duclos, A., & Stanescu, D. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12113746 · Cited by 19
Bautista, M., Kowal, M. R., Cave, D. G. W., Downey, C. L., & Jayne, D. G. (2023) · Journal of Clinical and Translational Science · doi:10.1017/cts.2023.547 · Cited by 21
Thomas, W., Henry, J., Chew, J. E., Premaratne, M., Blecher, G., & Haji, D. L. (2023) · Emergency Medicine Australasia · doi:10.1111/1742-6723.14262 · Cited by 20
Lai, D. K.-H., Cheng, E. S.-W., Lim, H.-J., So, B. P.-H., Lam, W., Cheung, D. S. K., Wong, D. W., & Cheung, J. C. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1205009 · Cited by 22
Preparing Well for Esophageal Endoscopic Detection Using a Hybrid Model and Transfer Learning
Chou, C., Nguyêñ, H. T., Wang, Y., Chen, T., Wu, I., Huang, C., & Wang, H. (2023) · Cancers · doi:10.3390/cancers15153783 · Cited by 19
Kumar, S., Parry, T., Mallett, S., Plumb, A., Bhatnagar, G., Beable, R., Betts, M., Duncan, G., Gupta, A., Higginson, A., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09958-6 · Cited by 21
Self-citationKobeissy, A. A., Merza, N., Al‐Hillan, A., Boujemaa, S., Ahmed, Z., Nawras, M., Albaaj, M., Dahiya, D. S., Alastal, Y., & Hassan, M. M. (2023) · Journal of Clinical Medicine Research · doi:10.14740/jocmr4951 · Cited by 22
Zhu, J., Yang, Y., & Wong, H. M. (2023) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2300244 · Cited by 20
Performance of Lung-RADS in different target populations: a systematic review and meta-analysis
Mao, Y., Cai, J., Heuvelmans, M. A., Vliegenthart, R., Groen, H. J. M., Oudkerk, M., Vonder, M., Dorrius, M. D., & de Bock, G. H. (2023) · European Radiology · doi:10.1007/s00330-023-10049-9 · Cited by 21
Radiomics in Carotid Plaque: A Systematic Review and Radiomics Quality Score Assessment
Hou, C., Liu, X., Du, Y., Cheng, L., Liu, L., Nie, F., Zhang, W., & He, W. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.06.008 · Cited by 20
Ma, Q., Li, Z., Li, W., Chen, Q., Liu, X., Feng, W., & Lei, J. (2023) · European Journal of Radiology · doi:10.1016/j.ejrad.2023.111127 · Cited by 19
Florijn, B. W., van der Bent, M. L., Nguyen, T. M., Quax, P. H. A., Wermer, M. J. H., Nossent, A. Y., & Kruyt, N. D. (2023) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2023.107388 · Cited by 19
Mobile audiometry for hearing threshold assessment: A systematic review and meta‐analysis
Oremulé, B., Abbas, J. R., Saunders, G. H., Kluk, K., Isba, R., Bate, S. G., & Bruce, I. A. (2023) · Clinical Otolaryngology · doi:10.1111/coa.14107 · Cited by 19
Chan, P. Z., Ramli, M. A. I. B., & Chew, H. S. J. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107636 · Cited by 22
Brack, C., Kynn, M., Murchie, P., & Makin, S. (2023) · Age and Ageing · doi:10.1093/ageing/afad173 · Cited by 19
Walle, M., Arkew, M., Asmerom, H., Tesfaye, A., & Getu, F. (2023) · PLoS ONE · doi:10.1371/journal.pone.0295011 · Cited by 24
Phuah, Y., Tan, Y. X., Zaghloul, S., Sim, S. J. Y., Wong, J. H., Usmani, S., Snell, L., Thavabalan, K., García-Pérez, C., Kumar, N. S., et al. (2023) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyad041 · Cited by 19
“13 Signalling questions were tailored to our study, and two independent re-viewers assessed all included studies using the tool.”
Hayden, M. K., Hanson, K. E., Englund, J. A., Lee, M. J., Loeb, M. B., Lee, F., Morgan, D. J., Patel, R., Mikati, I. K. E., Iqneibi, S., et al. (2023) · Clinical Infectious Diseases · doi:10.1093/cid/ciad646 · Cited by 24
Sagittal condylar guidance angle measurement methods: A systematic review
Lassmann, Ł., Nowak, Z., & Żółtowska, A. (2023) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2023.11.017 · Cited by 19
Dhar, A., Cendejas-Gomez, J. D. J., Mendez, L. C., Boldt, G., McArthur, E., Zamboglou, C., & Bauman, G. S. (2024) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2023.110070 · Cited by 22
Zadeh, F. S., Pooyan, A., Alipour, E., Hosseini, N., Thurlow, P. C., Grande, F. D., Shafiei, M., & Chalian, M. (2024) · Skeletal Radiology · doi:10.1007/s00256-024-04598-3 · Cited by 19
“The methodological quality of the included studies was assessed using QUADAS-2 (Quality assessed using Assessment of Diagnostic Accuracy Studies), a tool for evaluating diagnostic studies [21].”
Role of PSMA-targeted PET-CT in renal cell carcinoma: a systematic review and meta-analysis
Singhal, T., Singh, P., Parida, G. K., & Agrawal, K. (2024) · Annals of Nuclear Medicine · doi:10.1007/s12149-024-01904-w · Cited by 19
“The QUADAS-2 tool primarily assesses four domains: risk of bias in patient selection, reference standard, index test, and the timing and flow of reference test [8].”
Hu, J., Xie, S., Xia, W., Huang, F., Xu, B., Zuo, Z., Liao, Y., Qian, Z., & Zhang, L. (2024) · International Immunopharmacology · doi:10.1016/j.intimp.2024.111857 · Cited by 22
Tian, S., Li, X., Liu, J., Wang, X., Chen, H., Dai, Z., Chen, Q., Shi, H., Li, Y., Huang, H., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e29446 · Cited by 19
Mair, M. D., Singhavi, H. R., Pai, A., Khan, M., Conboy, P., Olaleye, O., Salha, R., Ameerally, P., Vaidhyanath, R., & Chaturvedi, P. (2024) · Cancers · doi:10.3390/cancers16081457 · Cited by 19
Early detection of diabetic neuropathy based on health belief model: a scoping review
Purwanti, O. S., Nursalam, N., & Pandin, M. G. R. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1369699 · Cited by 19
Han, J., Wen, J., & Hu, W. (2024) · Frontiers in Oncology · doi:10.3389/fonc.2024.1354837 · Cited by 21
Fu, Y., Zhou, J., & Li, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0303669 · Cited by 24
Martínez, C., Wang, Z., Zalazar, G., Sergio Carmona, G., Kattah, J. C., & Tarnutzer, A. A. (2024) · The Cerebellum · doi:10.1007/s12311-024-01718-6 · Cited by 19
Mason, R. H., Minaker, S. A., Luna, G. M. L., Bapat, P., Farahvash, A., Garg, A., Bhambra, N., & Muni, R. H. (2024) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2024.05.031 · Cited by 19
Jukema, R., Dahdal, J., Kooijman, E., Wahedi, E., de Winter, R. W., Guglielmo, M., Cramer, M. J., van der Harst, P., Remmelzwaal, S., Raijmakers, P. G. H. M., et al. (2024) · Heart · doi:10.1136/heartjnl-2024-324248 · Cited by 19
Portable noninvasive technologies for early breast cancer detection: A systematic review
Aboagye, S. O., Hunt, J. A., Ball, G., & Wei, Y. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109219 · Cited by 26
Webster, K. E., Parkhouse, T., Dawson, S., Jones, H. E., Brown, E. L., Hay, A. D., Whiting, P. F., Cabral, C., Caldwell, D. M., & Higgins, J. P. T. (2024) · Health Technology Assessment · doi:10.3310/jlcp4570 · Cited by 22
Self-citationCabanas, A. M., Saez, N. V., Caiconte, P. C., Martín-Escudero, P., Pagán, J., Jiménez-Herranz, E., & Ayala, J. L. (2024) · Bioengineering · doi:10.3390/bioengineering11111061 · Cited by 21
“Although there is no standard risk of bias tool for methods-comparison studies, we followed the QUADAS-2 protocol, which evaluates four domains: patient selection, index test, reference standard, and flow and timing of patients [80].”
Harlianto, N. I., van der Star, S., Suelmann, B. B. M., de Jong, P. A., Verlaan, J., & Foppen, W. (2024) · Clinical & Translational Oncology · doi:10.1007/s12094-024-03765-1 · Cited by 22
“Each of the four domains was scored on risk of bias as “low”, “high” or “unclear” [19].”
Prosty, C. J., Luo, O. D., Khalaf, R., Corpo, O. D., McDonald, E. G., & Lee, T. C. (2024) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2024.11.004 · Cited by 20
Gerke, O., Naghavi‐Behzad, M., Nygaard, S. T., Sigaroudi, V. R., Vogsen, M., Vach, W., & Hildebrandt, M. G. (2024) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2024.10.008 · Cited by 19
Vos, J. M. B. W., Bloem, M. N., de Geus, A., Leeflang, M., Spijker, R., Koppen, I. J. N., Baaleman, D. F., & Benninga, M. A. (2024) · Pediatric Radiology · doi:10.1007/s00247-024-06083-4 · Cited by 19
“Study quality was assessed by two authors (J.V. and D.B.) using the Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) [16].”
Self-citation
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.